Muhammad Asif
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Asif has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ejaz Ahmed
Computer Science Department, National University of Computer and Emerging Sciences (NUCES-FAST), Islamabad 44000, Pakistan
1 shared publication - Emad Abouel Nasr
Department of Industrial Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia
1 shared publication - Hafiz Tayyab Rauf
Independent Researcher, Bradford BD8 0HS, UK
1 shared publication - Hasan Ali Khattak
School of Electrical Engineering and Computer Science, National University of Sciences and Technology (NUST), Islamabad, Pakistan
1 shared publication - Munam Ali Shah
Department of Computer Networks and Communication, College of Computer Science and Information Technology, King Faisal University, Al-Ahsa, Saudi Arabia
1 shared publication - Shafaq Mussadiq
Institute of Computing, Kohat University of Science and Technology, Kohat, Pakistan
1 shared publication
Latest Publications
- Open Access
- 9 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 652
Intracranial Hemorrhage Detection Using Parallel Deep Convolutional Models and Boosting Mechanism
Intracranial hemorrhage (ICH) can lead to death or disability, which requires immediate action from radiologists. Due to the heavy workload, less experienced staff, and the complexity of subtle hemorrhages, a more intelligent and automated system is necessary to detect ICH. In literature, many artificial-intelligence-based methods are proposed. However, they are less accurate for ICH detection and subtype classification. Therefore, in this paper, we present a new methodology to improve the detection and subtype classification of ICH based on two parallel paths and a boosting technique. The first path employs the architecture of ResNet101-V2 to extract potential features from windowed slices, whereas Inception-V4 captures significant spatial information in the second path. Afterwards, the detection and subtype classification of ICH is performed by the light gradient boosting machine (LGBM) using the outputs of ResNet101-V2 and Inception-V4. Thus, the combined solution, known as ResNet101-V2, Inception-V4, and LGBM (Res-Inc-LGBM), is trained and tested over the brain computed tomography (CT) scans of CQ500 and Radiological Society of North America (RSNA) datasets. The experimental results state that the proposed solution efficiently obtains 97.7% accuracy, 96.5% sensitivity, and 97.4% F1 score using the RSNA dataset. Moreover, the proposed Res-Inc-LGBM outperforms the standard benchmarks for the detection and subtype classification of ICH regarding the accuracy, sensitivity, and F1 score. The results prove the significance of the proposed solution for its real-time application.
- 9 February 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (4) , 652
Open AccessIntracranial Hemorrhage Detection Using Parallel Deep Convolutional Models and Boosting Mechanism
Intracranial hemorrhage (ICH) can lead to death or disability, which requires immediate action from radiologists. Due to the heavy workload, less experienced staff, and the complexity of subtle hemorrhages, a more intelligent and automated system is necessary to detect ICH. In literature, many artificial-intelligence-based methods are proposed. However, they are less accurate for ICH detection and subtype classification. Therefore, in this paper, we present a new methodology to improve the detection and subtype classification of ICH based on two parallel paths and a boosting technique. The first path employs the architecture of ResNet101-V2 to extract potential features from windowed slices, whereas Inception-V4 captures significant spatial information in the second path. Afterwards, the detection and subtype classification of ICH is performed by the light gradient boosting machine (LGBM) using the outputs of ResNet101-V2 and Inception-V4. Thus, the combined solution, known as ResNet101-V2, Inception-V4, and LGBM (Res-Inc-LGBM), is trained and tested over the brain computed tomography (CT) scans of CQ500 and Radiological Society of North America (RSNA) datasets. The experimental results state that the proposed solution efficiently obtains 97.7% accuracy, 96.5% sensitivity, and 97.4% F1 score using the RSNA dataset. Moreover, the proposed Res-Inc-LGBM outperforms the standard benchmarks for the detection and subtype classification of ICH regarding the accuracy, sensitivity, and F1 score. The results prove the significance of the proposed solution for its real-time application.