William R. Santee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
William R. Santee has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xiaojiang Xu
US Army Research Institute of Environmental Medicine
3 shared publications - Adam W. Potter
United States Army Research Institute of Environmental Medicine, Natick, USA
2 shared publications - David P. Looney
US Army Research Institute of Environmental Medicine , Natick, MA 01760
2 shared publications Anthony J. Karis
United States Army Res Inst Environm Med USARIEM, 10 Gen Greene Ave, Natick, MA 01760 USA
1 shared publicationDanielle M. Arcidiacono
United States Army Res Inst Environm Med USARIEM, 10 Gen Greene Ave, Natick, MA 01760 USA
1 shared publication- Elizabeth M. Lavoie
Department of Exercise and Nutrition Sciences, Center for Research and Education in Special Environments, University at Buffalo , Buffalo, NY 14214
1 shared publication
Latest Publications
- Open Access
- 8 February 2023
- Published by Elsevier in Applied Ergonomics
- Vol. 109, 103985
Peak performance and cardiometabolic responses of modern US army soldiers during heavy, fatiguing vest-borne load carriage
- 8 February 2023
- Published by Elsevier in Applied Ergonomics
- Vol. 109, 103985
Open AccessPeak performance and cardiometabolic responses of modern US army soldiers during heavy, fatiguing vest-borne load carriage
- Open Access
- 19 August 2021
- Published by U.S. Army Engineer Research and Development Center
Terrain coefficients for predicting energy costs of walking over snow
- 19 August 2021
- Published by U.S. Army Engineer Research and Development Center
Open AccessTerrain coefficients for predicting energy costs of walking over snow
- 1 September 2020
- Published by ASTM International
- p. 237-249
Methods to Determine Drying Time of Wet Clothing Using a Thermal Manikin
- 1 September 2020
- Published by ASTM International
- p. 237-249
Methods to Determine Drying Time of Wet Clothing Using a Thermal Manikin
- 1 October 2008
- Published by ASTM International in Journal of ASTM International
- Vol. 5 (9) , 1-6
Comparison of Parallel and Serial Methods for Determining Clothing Insulation
This paper examines the fundamental differences between the parallel and serial methods for the calculation of clothing insulation using a thermal manikin and demonstrates the differences in the insulation values calculated using these two methods. The parallel method is based on the condition that manikin surface temperatures remain uniform (UST), while the serial method is based on the condition that manikin heat fluxes remain uniform (UHF). Eleven clothing ensembles were evaluated on manikins in UST mode. Three of them were also evaluated on manikins in UHF mode. Insulation values were then calculated using both the serial and parallel methods. Results from UST mode showed that the parallel insulation values ranged from 1.24 to 5.79 clo, while the serial insulation values ranged from 1.43 to 7.98 clo. Differences in the parallel and serial insulations increased as the insulation increased, and the serial insulations were approximately 14–38 % higher than the parallel insulations. Results from UHF mode showed that the parallel insulations were 1.30 clo to 5.89 clo and close to the serial insulations of 1.34 clo to 5.99 clo. In conclusion, the methods of insulation calculation should be determined by the operating mode of the manikin. Only the parallel method should be used when manikins are operated in UST mode and only the serial method should be used when manikins are operated in UHF mode. Insulation values calculated using the incorrect method will be misleading.
- 1 October 2008
- Published by ASTM International in Journal of ASTM International
- Vol. 5 (9) , 1-6
Comparison of Parallel and Serial Methods for Determining Clothing Insulation
This paper examines the fundamental differences between the parallel and serial methods for the calculation of clothing insulation using a thermal manikin and demonstrates the differences in the insulation values calculated using these two methods. The parallel method is based on the condition that manikin surface temperatures remain uniform (UST), while the serial method is based on the condition that manikin heat fluxes remain uniform (UHF). Eleven clothing ensembles were evaluated on manikins in UST mode. Three of them were also evaluated on manikins in UHF mode. Insulation values were then calculated using both the serial and parallel methods. Results from UST mode showed that the parallel insulation values ranged from 1.24 to 5.79 clo, while the serial insulation values ranged from 1.43 to 7.98 clo. Differences in the parallel and serial insulations increased as the insulation increased, and the serial insulations were approximately 14–38 % higher than the parallel insulations. Results from UHF mode showed that the parallel insulations were 1.30 clo to 5.89 clo and close to the serial insulations of 1.34 clo to 5.99 clo. In conclusion, the methods of insulation calculation should be determined by the operating mode of the manikin. Only the parallel method should be used when manikins are operated in UST mode and only the serial method should be used when manikins are operated in UHF mode. Insulation values calculated using the incorrect method will be misleading.
- 16 February 2007
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 100 (1) , 79-88
Thermal responses for men with different fat compositions during immersion in cold water at two depths: prediction versus observation
A cold thermoregulatory model (CTM) was applied to data from partially immersed subjects divided into normal (NF) or low fat (LF) groups in order to validate CTM during immersion at two depths and to examine mechanisms underlying the individual differences. CTM defines thermal characteristics, e.g. surface area and maximal shivering intensity, using height, weight, fat %, age and VO(2max). Ten clothed subjects, 5 NF (15-19%) and 5 LF (8.1-14.7%), were immersed in both 10 and 15 degrees C water at chest (CH) and waist (WA) level. Environmental and clothing inputs for CTM were weighted to adjust for the ratio of skin surface area covered by either air or water at various immersion depths. Predicted core temperature (Tc) responses for each individual trial were compared with measured data. There were no significant differences (P > 0.05) between measured Tc and predicted Tc for NF at all four conditions. In contrast, for the LF group, the predicted Tc responses were all higher than measured (P < 0.05). However, predicted Tc agreed closer with measured Tc for LF when leg muscle blood flow was increased in the simulation. This suggests that blood flow may contribute to the rapid decline in Tc observed in LF and its variance may cause in part the individual differences in Tc responses. CTM predicts Tc responses to immersion at various depths with acceptable accuracy for NF individuals in this study and can be adapted to non-uniform environments.
- 16 February 2007
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 100 (1) , 79-88
Thermal responses for men with different fat compositions during immersion in cold water at two depths: prediction versus observation
A cold thermoregulatory model (CTM) was applied to data from partially immersed subjects divided into normal (NF) or low fat (LF) groups in order to validate CTM during immersion at two depths and to examine mechanisms underlying the individual differences. CTM defines thermal characteristics, e.g. surface area and maximal shivering intensity, using height, weight, fat %, age and VO(2max). Ten clothed subjects, 5 NF (15-19%) and 5 LF (8.1-14.7%), were immersed in both 10 and 15 degrees C water at chest (CH) and waist (WA) level. Environmental and clothing inputs for CTM were weighted to adjust for the ratio of skin surface area covered by either air or water at various immersion depths. Predicted core temperature (Tc) responses for each individual trial were compared with measured data. There were no significant differences (P > 0.05) between measured Tc and predicted Tc for NF at all four conditions. In contrast, for the LF group, the predicted Tc responses were all higher than measured (P < 0.05). However, predicted Tc agreed closer with measured Tc for LF when leg muscle blood flow was increased in the simulation. This suggests that blood flow may contribute to the rapid decline in Tc observed in LF and its variance may cause in part the individual differences in Tc responses. CTM predicts Tc responses to immersion at various depths with acceptable accuracy for NF individuals in this study and can be adapted to non-uniform environments.