Jonathan R. Dubin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jonathan R. Dubin has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Akin Cil
3 shared publicationsAn-Lin Cheng
2 shared publications- Cemil Cihad Gedik
Department of Orthopaedics and Traumatology, Koç University School of Medicine, Istanbul, Türkiye
2 shared publications Martha Murray
2 shared publications- Parker D. Boyce
University of Missouri—Kansas City, School of Medicine, Kansas City, Missouri
2 shared publications - Akin Cil
Department of Civil and Mechanical Engineering, University of Missouri-Kansas City, 5110 Rockhill Road, Kansas City, MO 64110, USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (3)
Disparities in Industry Payments Between Orthopaedic Surgery and General Surgery Residents
Background: Industry funding may support surgical training but also raises conflict-of-interest concerns, particularly among financially vulnerable residents. This study examined whether the prevalence and magnitude of Centers for Medicare & Medicaid Services (CMS) Open Payments general payments differed between postgraduate year 5 (PGY-5) orthopaedic surgery (OS) and general surgery (GS) residents graduating in 2025, and whether these payments varied by institution type and geographic region. Methods: We performed a cross-sectional analysis of CMS Open Payments (2018-2024) for PGY-5 residents in OS and GS graduating in 2025. Residency programs were identified, and PGY-5 rosters were compiled from program websites. Residents were linked to Open Payments records. Payments were categorized as Consulting Fees/Grants/Charity, Travel/Education Support, and Hospitality. Payment prevalence and payment amounts were compared between specialties, with adjustment for institution type and geographic region. Results: Across 150 institutions (120 GS programs, 117 OS programs), 1,591 residents were analyzed. Overall, 861 of 1,591 residents (54%) had ≥1 payment; OS residents had higher prevalence than GS (57% vs. 52%; OR 1.25, 95% confidence interval [CI]: 1.03-1.53; p = 0.03). Unadjusted mean payments were $3,176 (OS) versus $798 (GS) (p < 0.0001). Adjusted mean payments remained higher for OS ($3,202) than GS ($653), a 4.90-fold difference (p < 0.0001), with significant interactions by institution type and region. Conclusions: Over half of PGY-5 GS and OS residents receive industry payments, although OS receive substantially more overall. These payments are highly concentrated at the top tier of recipients. Training programs, governing bodies, and other key stakeholders should consider developing a structured approach that capitalizes on the industry financial support while minimizing bias in resident education and delivering a more equitable distribution to all residents. Level of Evidence or Clinical Relevance: Level III (cross-sectional observational study); clinically relevant to graduate medical education policy and conflict-of-interest oversight. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2026
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 11 (3)
Open AccessDisparities in Industry Payments Between Orthopaedic Surgery and General Surgery Residents
Background: Industry funding may support surgical training but also raises conflict-of-interest concerns, particularly among financially vulnerable residents. This study examined whether the prevalence and magnitude of Centers for Medicare & Medicaid Services (CMS) Open Payments general payments differed between postgraduate year 5 (PGY-5) orthopaedic surgery (OS) and general surgery (GS) residents graduating in 2025, and whether these payments varied by institution type and geographic region. Methods: We performed a cross-sectional analysis of CMS Open Payments (2018-2024) for PGY-5 residents in OS and GS graduating in 2025. Residency programs were identified, and PGY-5 rosters were compiled from program websites. Residents were linked to Open Payments records. Payments were categorized as Consulting Fees/Grants/Charity, Travel/Education Support, and Hospitality. Payment prevalence and payment amounts were compared between specialties, with adjustment for institution type and geographic region. Results: Across 150 institutions (120 GS programs, 117 OS programs), 1,591 residents were analyzed. Overall, 861 of 1,591 residents (54%) had ≥1 payment; OS residents had higher prevalence than GS (57% vs. 52%; OR 1.25, 95% confidence interval [CI]: 1.03-1.53; p = 0.03). Unadjusted mean payments were $3,176 (OS) versus $798 (GS) (p < 0.0001). Adjusted mean payments remained higher for OS ($3,202) than GS ($653), a 4.90-fold difference (p < 0.0001), with significant interactions by institution type and region. Conclusions: Over half of PGY-5 GS and OS residents receive industry payments, although OS receive substantially more overall. These payments are highly concentrated at the top tier of recipients. Training programs, governing bodies, and other key stakeholders should consider developing a structured approach that capitalizes on the industry financial support while minimizing bias in resident education and delivering a more equitable distribution to all residents. Level of Evidence or Clinical Relevance: Level III (cross-sectional observational study); clinically relevant to graduate medical education policy and conflict-of-interest oversight. See Instructions for Authors for a complete description of levels of evidence.
- 12 December 2025
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (12) , e1628-e1635
Characterization and Time-delay in Issuing High-risk Recalls of Orthopaedic Devices From 2002 to 2023
Introduction: Orthopaedic devices constitute nearly 20% of all medical devices, with approximately 12% of implants recalled within 10 years of Food and Drug Administration (FDA) clearance. Class I recalls represent the FDA's highest level of concern, indicating that device use could result in serious injury or death. Despite their severity, class I orthopaedic device recalls have not been systematically characterized, and concerns remain regarding delayed responsiveness to safety signals. Methods: The FDA recall database was reviewed for class I medical device recalls from November 2002 to December 2023, and orthopaedic-related events were identified. Devices were categorized by subspecialty (arthroplasty, spine, other), authorization pathway (510(k) vs. Premarket Approval (PMA)), and recall cause. FDA-designated root causes were reclassified into clinically relevant categories. Annual Manufacturer and User-facility Device Experience files were reviewed for associated adverse event reports (AERs), and the interval between the earliest AER and formal recall was calculated. Statistical comparisons were made using the Fisher exact test and Mann-Whitney U test. Results: Sixteen class I recall events affecting 20 orthopaedic devices were identified: 50% arthroplasty, 44% spine, and 6% other. Only 13% of recalled devices underwent PMA; the rest were 510(k)-cleared. Most recalls (69%) were due to intrinsic device design flaws. Surgeon consensus reached through reconciliation of differences on root cause–matched FDA categorization in only 30% of non–design-designated recalls. The median AER-to-recall interval was significantly longer for arthroplasty devices (5.8 years) than spine devices (1.8 years, P = 0.014). Conclusion: Most class I orthopaedic device recalls involved design flaws in 510(k)-cleared implants and were subject to notable delays between initial adverse reports and recall, particularly in arthroplasty implants. Discrepancies between FDA classifications and clinical judgment, as well as inconsistent recall labeling, highlight the need for more robust and specific postmarket surveillance. This includes collaboration with surgeons and potential linkages with existing registries, such as the American Academy of Orthopedic Surgeons' American Joint Replacement Registry, to facilitate early identification of problematic devices.
- 12 December 2025
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 34 (12) , e1628-e1635
Characterization and Time-delay in Issuing High-risk Recalls of Orthopaedic Devices From 2002 to 2023
Introduction: Orthopaedic devices constitute nearly 20% of all medical devices, with approximately 12% of implants recalled within 10 years of Food and Drug Administration (FDA) clearance. Class I recalls represent the FDA's highest level of concern, indicating that device use could result in serious injury or death. Despite their severity, class I orthopaedic device recalls have not been systematically characterized, and concerns remain regarding delayed responsiveness to safety signals. Methods: The FDA recall database was reviewed for class I medical device recalls from November 2002 to December 2023, and orthopaedic-related events were identified. Devices were categorized by subspecialty (arthroplasty, spine, other), authorization pathway (510(k) vs. Premarket Approval (PMA)), and recall cause. FDA-designated root causes were reclassified into clinically relevant categories. Annual Manufacturer and User-facility Device Experience files were reviewed for associated adverse event reports (AERs), and the interval between the earliest AER and formal recall was calculated. Statistical comparisons were made using the Fisher exact test and Mann-Whitney U test. Results: Sixteen class I recall events affecting 20 orthopaedic devices were identified: 50% arthroplasty, 44% spine, and 6% other. Only 13% of recalled devices underwent PMA; the rest were 510(k)-cleared. Most recalls (69%) were due to intrinsic device design flaws. Surgeon consensus reached through reconciliation of differences on root cause–matched FDA categorization in only 30% of non–design-designated recalls. The median AER-to-recall interval was significantly longer for arthroplasty devices (5.8 years) than spine devices (1.8 years, P = 0.014). Conclusion: Most class I orthopaedic device recalls involved design flaws in 510(k)-cleared implants and were subject to notable delays between initial adverse reports and recall, particularly in arthroplasty implants. Discrepancies between FDA classifications and clinical judgment, as well as inconsistent recall labeling, highlight the need for more robust and specific postmarket surveillance. This includes collaboration with surgeons and potential linkages with existing registries, such as the American Academy of Orthopedic Surgeons' American Joint Replacement Registry, to facilitate early identification of problematic devices.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (2)
Myotendinous Rupture of the Posterior Tibial Tendon with Associated Fibular Fracture
Case: A 20-year-old man presented after a fall from an 8-foot ladder. Radiographs revealed pronation external rotation injury. Closed reduction and splinting was performed in the emergency department. Surgery was planned 6 days later to include open reduction and internal fixation of the fibula and syndesmosis, and open repair of deltoid ligament. Intraoperatively, a myotendinous rupture of the posterior tibial tendon (PTT) was identified and repaired. Conclusion: PTT ruptures are rarely reported but should be suspected in high-energy mechanism ankle fractures in all patients. Direct repair can result in excellent outcomes.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (2)
Myotendinous Rupture of the Posterior Tibial Tendon with Associated Fibular Fracture
Case: A 20-year-old man presented after a fall from an 8-foot ladder. Radiographs revealed pronation external rotation injury. Closed reduction and splinting was performed in the emergency department. Surgery was planned 6 days later to include open reduction and internal fixation of the fibula and syndesmosis, and open repair of deltoid ligament. Intraoperatively, a myotendinous rupture of the posterior tibial tendon (PTT) was identified and repaired. Conclusion: PTT ruptures are rarely reported but should be suspected in high-energy mechanism ankle fractures in all patients. Direct repair can result in excellent outcomes.
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (1)
Use of Cemented Hemiarthroplasty for Femoral Neck Fractures
Geriatric femoral neck fractures are common orthopaedic injuries, which are associated with a high morbidity and mortality. Arthroplasty is the optimum treatment for many of these injuries, but debate exists regarding optimal surgical strategy. Multiple recent investigations have demonstrated strong superiority for cemented stems as compared with noncemented fixation with a decreased risk of periprosthetic fracture, shorter length of stay, lower cost, and decreased rate for revision surgery. The main purpose of this article is to refamiliarize the resident or practicing surgeon with cemented arthroplasty by reviewing the basic science of cement, common cementing concerns, and outcomes, as well as by providing tips on cementing technique to ensure safe, simple, and reproducible results.
- 1 January 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (1)
Open AccessUse of Cemented Hemiarthroplasty for Femoral Neck Fractures
Geriatric femoral neck fractures are common orthopaedic injuries, which are associated with a high morbidity and mortality. Arthroplasty is the optimum treatment for many of these injuries, but debate exists regarding optimal surgical strategy. Multiple recent investigations have demonstrated strong superiority for cemented stems as compared with noncemented fixation with a decreased risk of periprosthetic fracture, shorter length of stay, lower cost, and decreased rate for revision surgery. The main purpose of this article is to refamiliarize the resident or practicing surgeon with cemented arthroplasty by reviewing the basic science of cement, common cementing concerns, and outcomes, as well as by providing tips on cementing technique to ensure safe, simple, and reproducible results.
- 5 June 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (17) , 1594-1599
Pediatric Device Innovation
Background: Despite a tremendous increase in the number of orthopaedic devices authorized by the U.S. Food and Drug Administration (FDA), novel devices designed specifically for the pediatric population remain sparse. Surgeons frequently repurpose adult implants for “off-label” use in pediatric patients, with both legal and technical ramifications. This study seeks to objectively quantify and characterize the nature of pediatric device innovation over time. Methods: The FDA employs 4 pathways for assessing safety and effectiveness of novel devices prior to authorization. Perceived device risk and novelty determine the pathway. Orthopaedic devices were identified from the FDA’s online database. All devices approved since inception via the Humanitarian Device Exemption, Pre-Market Approval, and De Novo regulatory pathways were included and grouped as “highly innovative.” Because of their number and the rapidity of their development, the evaluation of 510(k) devices was limited to those cleared from January 1, 2018, to December 31, 2022. Such 510(k) devices make up ∼97% of devices and by definition are less risky and less novel. Approval statements were assessed for pediatric indications within the approved labeling. As a secondary analysis, the impact of company size on developing a product with a pediatric indication was analyzed. Results: Of the 1,925 devices cleared via the 510(k) pathway, 9 (0.5%) were designed exclusively for pediatrics and 160 (8.3%) included pediatric indications. Five of the 9 pediatrics-only devices were for spine and 4 were for trauma indications. Of the 97 highly innovative devices, only 2 (2%) were exclusively pediatric and another 2 (2%) included pediatric indications. The 2 pediatrics-only devices were for the spine. Large and medium-sized companies were 1.9 times and 1.6 times more likely to bring to market a device with pediatric indications than a small company, respectively. Conclusions: Innovation for pediatric orthopaedic devices lags substantially behind that for adult orthopaedic devices. These findings are consistent with clinical experience and the common practice of modifying adult implants for “off-label” use in pediatric patients. Despite long-standing efforts to stimulate innovation for this vulnerable population, our results suggest little progress.
- 5 June 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (17) , 1594-1599
Pediatric Device Innovation
Background: Despite a tremendous increase in the number of orthopaedic devices authorized by the U.S. Food and Drug Administration (FDA), novel devices designed specifically for the pediatric population remain sparse. Surgeons frequently repurpose adult implants for “off-label” use in pediatric patients, with both legal and technical ramifications. This study seeks to objectively quantify and characterize the nature of pediatric device innovation over time. Methods: The FDA employs 4 pathways for assessing safety and effectiveness of novel devices prior to authorization. Perceived device risk and novelty determine the pathway. Orthopaedic devices were identified from the FDA’s online database. All devices approved since inception via the Humanitarian Device Exemption, Pre-Market Approval, and De Novo regulatory pathways were included and grouped as “highly innovative.” Because of their number and the rapidity of their development, the evaluation of 510(k) devices was limited to those cleared from January 1, 2018, to December 31, 2022. Such 510(k) devices make up ∼97% of devices and by definition are less risky and less novel. Approval statements were assessed for pediatric indications within the approved labeling. As a secondary analysis, the impact of company size on developing a product with a pediatric indication was analyzed. Results: Of the 1,925 devices cleared via the 510(k) pathway, 9 (0.5%) were designed exclusively for pediatrics and 160 (8.3%) included pediatric indications. Five of the 9 pediatrics-only devices were for spine and 4 were for trauma indications. Of the 97 highly innovative devices, only 2 (2%) were exclusively pediatric and another 2 (2%) included pediatric indications. The 2 pediatrics-only devices were for the spine. Large and medium-sized companies were 1.9 times and 1.6 times more likely to bring to market a device with pediatric indications than a small company, respectively. Conclusions: Innovation for pediatric orthopaedic devices lags substantially behind that for adult orthopaedic devices. These findings are consistent with clinical experience and the common practice of modifying adult implants for “off-label” use in pediatric patients. Despite long-standing efforts to stimulate innovation for this vulnerable population, our results suggest little progress.
- 30 January 2024
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 32 (7) , 296-301
American Academy of Orthopaedic Surgeons Technology Overview Summary: Platelet-Rich Plasma (PRP) for Knee Osteoarthritis
The Platelet-Rich Plasma (PRP) for Knee Osteoarthritis Technology Overview is based on a systematic review of current scientific and clinical research. Through analysis of the current best evidence, this technology overview seeks to evaluate the efficacy of PRP for patients with knee osteoarthritis. The systematic literature review resulted in 54 articles: 36 high-quality and 18 moderate-quality. The findings of these studies were summarized to present findings on PRP versus control/placebo, acetaminophen, non-steroidal anti-inflammatory drugs, corticosteroids, exercise, prolotherapy, autologous conditioned serum, bone marrow aspirate concentrate, hyaluronic acid, and ozone therapy. In addition, the work group highlighted areas that needed additional research when evidence proved lacking on the topic and carefully noted the potential harms associated with an intervention, required resource utilization, acceptability, and feasibility.
- 30 January 2024
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 32 (7) , 296-301
American Academy of Orthopaedic Surgeons Technology Overview Summary: Platelet-Rich Plasma (PRP) for Knee Osteoarthritis
The Platelet-Rich Plasma (PRP) for Knee Osteoarthritis Technology Overview is based on a systematic review of current scientific and clinical research. Through analysis of the current best evidence, this technology overview seeks to evaluate the efficacy of PRP for patients with knee osteoarthritis. The systematic literature review resulted in 54 articles: 36 high-quality and 18 moderate-quality. The findings of these studies were summarized to present findings on PRP versus control/placebo, acetaminophen, non-steroidal anti-inflammatory drugs, corticosteroids, exercise, prolotherapy, autologous conditioned serum, bone marrow aspirate concentrate, hyaluronic acid, and ozone therapy. In addition, the work group highlighted areas that needed additional research when evidence proved lacking on the topic and carefully noted the potential harms associated with an intervention, required resource utilization, acceptability, and feasibility.
- 9 February 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (8) , 1444-1448
Risk of Recall for Total Joint Arthroplasty Devices Over 10 Years
- 9 February 2023
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 38 (8) , 1444-1448
Risk of Recall for Total Joint Arthroplasty Devices Over 10 Years
- 1 January 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (4)
A Case Report of U-Type Sacral Fracture After Chiropractic Adjustment
Case: A U-type sacral fracture, or spinopelvic dissociation, resulting from chiropractic manipulation has not been described in the medical literature. This report presents the case of a 74-year-old male patient who sustained a U-type sacral fracture after drop-table chiropractic manipulation. Conclusion: Our case demonstrates that chiropractic manipulative therapy involving the commonly used drop-table can cause severe injury. The patient’s course was complicated by a delay in diagnosis and a prolonged hospital stay. Orthopaedic surgeons should have a high degree of suspicion for spinopelvic dissociation in the setting of bilateral sacral fractures. One year after injury, with conservative management, the patient returned to baseline function with mild residual neuropathy.
- 1 January 2023
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 13 (4)
A Case Report of U-Type Sacral Fracture After Chiropractic Adjustment
Case: A U-type sacral fracture, or spinopelvic dissociation, resulting from chiropractic manipulation has not been described in the medical literature. This report presents the case of a 74-year-old male patient who sustained a U-type sacral fracture after drop-table chiropractic manipulation. Conclusion: Our case demonstrates that chiropractic manipulative therapy involving the commonly used drop-table can cause severe injury. The patient’s course was complicated by a delay in diagnosis and a prolonged hospital stay. Orthopaedic surgeons should have a high degree of suspicion for spinopelvic dissociation in the setting of bilateral sacral fractures. One year after injury, with conservative management, the patient returned to baseline function with mild residual neuropathy.
- 2 June 2022
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30 (14) , 658-667
The FDA and Ensuring Safety and Effectiveness of Devices, Biologics, and Technology
Orthopaedic devices account for nearly 20% of all devices on the market, with more than 600 novel orthopaedic devices cleared or approved by the FDA for marketing in the United States annually. Advances in technology and biologic therapies offer tremendous potential for patients with musculoskeletal ailments; however, it is important that the safety and effectiveness of these products be assessed to safeguard the public health. The FDA uses multiple different premarket pathways for devices, biologics, and combination products based on perceived risk of the novel product. More than 97% of orthopaedic devices go through the FDA's 510(k) pathway, which does not require clinical trials. The remaining high-risk devices must receive premarket approval and submit clinical trial data demonstrating safety and effectiveness. Similarly, high-risk biologics must obtain a biologics license application by submitting clinical trial data. Postmarketing surveillance strategies, including extended clinical trials or real-world evidence from registries, are increasingly being relied on by the FDA to expedite approval while also improving its capacity to identify problematic products.
- 2 June 2022
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30 (14) , 658-667
The FDA and Ensuring Safety and Effectiveness of Devices, Biologics, and Technology
Orthopaedic devices account for nearly 20% of all devices on the market, with more than 600 novel orthopaedic devices cleared or approved by the FDA for marketing in the United States annually. Advances in technology and biologic therapies offer tremendous potential for patients with musculoskeletal ailments; however, it is important that the safety and effectiveness of these products be assessed to safeguard the public health. The FDA uses multiple different premarket pathways for devices, biologics, and combination products based on perceived risk of the novel product. More than 97% of orthopaedic devices go through the FDA's 510(k) pathway, which does not require clinical trials. The remaining high-risk devices must receive premarket approval and submit clinical trial data demonstrating safety and effectiveness. Similarly, high-risk biologics must obtain a biologics license application by submitting clinical trial data. Postmarketing surveillance strategies, including extended clinical trials or real-world evidence from registries, are increasingly being relied on by the FDA to expedite approval while also improving its capacity to identify problematic products.