Alexander W. Katz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander W. Katz has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Charlene B. Y. Kim
Department of Ophthalmology and Visual Sciences, University of Wisconsin—Madison, Madison, Wisconsin, USA
5 shared publications - T. Michael Nork
Department of Ophthalmology and Visual Sciences, University of Wisconsin—Madison, Madison, Wisconsin, USA
5 shared publications - James Ver Hoeve
Department of Ophthalmology and Visual Sciences, University of Wisconsin—Madison, Madison, Wisconsin, USA
4 shared publications - Carol A. Rasmussen
Department of Ophthalmology and Visual Sciences, University of Wisconsin—Madison, Madison, Wisconsin, USA
3 shared publications - Amy Hartman
Department of Communication Sciences and Disorders, University of Wisconsin-Madison, Madison, WI, USA
2 shared publications Andrea M. Weiler
Wisconsin National Primate Research Center, University of Wisconsin-Madison, Madison, WI, USA
2 shared publications
Latest Publications
- 13 July 2026
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 42 (10) , 658-670
Preexisting Fundus Findings in a Large Cohort of Young Cynomolgus Macaques ( Macaca fascicularis ) Bred for Ocular Research: Comparison to Humans
Purpose: To categorize preexisting fundus findings in a large group of healthy young adult cynomolgus macaques [nonhuman primates (NHPs)] and to compare them to similar conditions in young human retinas. Methods: During the past 30 years, more than 20,000 young purpose-bred cynomolgus macaques were screened prior to enrollment in nonclinical pharmaceutical development studies at a single contract research organization. The fundus findings were documented by clinical examinations, various retinal imaging modalities, and/or visual electrophysiological testing. Results: Sheen from the internal limiting membrane (ILM) was common in these young adult NHPs as it is in young humans. Infrequent in both NHPs and humans were cilioretinal arteries. Small patches of retinal pigment epithelial (RPE) depigmentation were common, for which there is no human correlate. Likewise, there is no exact human correlate for foveal drusen-like spots in the young NHPs. Also common in NHPs but uncommon in humans were remnants of the fetal vasculature. Conditions rare in both NHPs and humans included myelinated nerve fiber layer, astrocytic hamartoma, coloboma, and congenital hypertrophy of the RPE. Notable rare abnormal findings included a white dot condition, a large macular tumor, and idiopathic optic atrophy, all of which were of unknown etiology. Discussion: Preexisting abnormalities, when taken together, are common in NHPs and can occasionally complicate the assessment of toxicity from test articles subsequently administered, impacting the clinical development of test articles. As such, it is critical that NHPs be prescreened and, ideally, the fundus appearance be documented with fundus imaging when enrolled in preclinical studies.
- 13 July 2026
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 42 (10) , 658-670
Preexisting Fundus Findings in a Large Cohort of Young Cynomolgus Macaques ( Macaca fascicularis ) Bred for Ocular Research: Comparison to Humans
Purpose: To categorize preexisting fundus findings in a large group of healthy young adult cynomolgus macaques [nonhuman primates (NHPs)] and to compare them to similar conditions in young human retinas. Methods: During the past 30 years, more than 20,000 young purpose-bred cynomolgus macaques were screened prior to enrollment in nonclinical pharmaceutical development studies at a single contract research organization. The fundus findings were documented by clinical examinations, various retinal imaging modalities, and/or visual electrophysiological testing. Results: Sheen from the internal limiting membrane (ILM) was common in these young adult NHPs as it is in young humans. Infrequent in both NHPs and humans were cilioretinal arteries. Small patches of retinal pigment epithelial (RPE) depigmentation were common, for which there is no human correlate. Likewise, there is no exact human correlate for foveal drusen-like spots in the young NHPs. Also common in NHPs but uncommon in humans were remnants of the fetal vasculature. Conditions rare in both NHPs and humans included myelinated nerve fiber layer, astrocytic hamartoma, coloboma, and congenital hypertrophy of the RPE. Notable rare abnormal findings included a white dot condition, a large macular tumor, and idiopathic optic atrophy, all of which were of unknown etiology. Discussion: Preexisting abnormalities, when taken together, are common in NHPs and can occasionally complicate the assessment of toxicity from test articles subsequently administered, impacting the clinical development of test articles. As such, it is critical that NHPs be prescreened and, ideally, the fundus appearance be documented with fundus imaging when enrolled in preclinical studies.
- Open Access
- 13 April 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Author Correction: Prenatal Zika virus exposure disrupts social-emotional development and cortical visual function in infant macaques
- 13 April 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessAuthor Correction: Prenatal Zika virus exposure disrupts social-emotional development and cortical visual function in infant macaques
- Open Access
- 29 January 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Prenatal Zika virus exposure disrupts social-emotional development and cortical visual function in infant macaques
Prenatal Zika virus (ZIKV) exposure can result in outcomes ranging from severe birth defects to subtle developmental delays, yet the underlying mechanisms remain unclear. Using a translational rhesus macaque model, we assess visual, auditory, and neurodevelopmental outcomes through 12 months of age following first-trimester ZIKV inoculation. Pregnant macaques, either flavivirus-naive or with prior dengue virus (DENV) exposure, are inoculated with Asian or African ZIKV lineages. Maternal viremia duration, placental viral burden, and neutralizing antibody titers vary but are not associated with developmental outcomes. At 12 months, ZIKV-exposed infants exhibit altered maternal attachment behaviors and reduced inhibition toward novel sensory stimuli. Visual evoked potentials are impaired at 3 months but normalize by 12 months; hearing loss is more frequent but not statistically significant. These outcomes are driven by ZIKV exposure itself, independent of maternal infection characteristics. Our findings highlight the limitations of maternal biomarkers in risk prediction and support incorporating infant-focused developmental outcomes in studies of maternal interventions.
- 29 January 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessPrenatal Zika virus exposure disrupts social-emotional development and cortical visual function in infant macaques
Prenatal Zika virus (ZIKV) exposure can result in outcomes ranging from severe birth defects to subtle developmental delays, yet the underlying mechanisms remain unclear. Using a translational rhesus macaque model, we assess visual, auditory, and neurodevelopmental outcomes through 12 months of age following first-trimester ZIKV inoculation. Pregnant macaques, either flavivirus-naive or with prior dengue virus (DENV) exposure, are inoculated with Asian or African ZIKV lineages. Maternal viremia duration, placental viral burden, and neutralizing antibody titers vary but are not associated with developmental outcomes. At 12 months, ZIKV-exposed infants exhibit altered maternal attachment behaviors and reduced inhibition toward novel sensory stimuli. Visual evoked potentials are impaired at 3 months but normalize by 12 months; hearing loss is more frequent but not statistically significant. These outcomes are driven by ZIKV exposure itself, independent of maternal infection characteristics. Our findings highlight the limitations of maternal biomarkers in risk prediction and support incorporating infant-focused developmental outcomes in studies of maternal interventions.
- 1 November 2025
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 41 (9) , 544-553
Custom-Made Injector for Suprachoroidal Ocular Delivery: Effect of Intraocular Pressure, Volume, and Location on the Distribution of Aqueous Solutions in Rabbits
Purpose: Develop a custom-made injector system for delivery of aqueous solutions to the suprachoroidal space (SCS). And to test the effect of intraocular pressure (IOP), volume, and location on distribution. Methods: SCS injectors were produced in the laboratory using readily available components. Fifty 100 µL of either fluorescein sodium and/or indocyanine green (ICG) dye solutions were injected 6-mm posterior to the corneal limbus in either the superotemporal or inferonasal quadrants of the eyes of albino rabbits. Coverage of the injected dyes was documented in vivo. Distribution of 50- and 100-µL single-injection volumes was compared, as were 50-µL injections in two opposing quadrants. The vasoconstrictor endothelin-1 was injected into some eyes as a test of efficacy. To determine the possible effects of IOP on injection coverage, both eyes of 6 rabbits were injected with ICG in a crossover design with the IOPs of the eyes held manometrically at either 10 or 35 mmHg. Results: Successful SCS injections, as determined by fundus imaging, were done in more than 40 rabbit eyes [as well as 40 nonhuman primate eyes in separate studies]. One hundred microliters single injections provided better coverage than 50 µL, but the most complete coverage was with two 50-µL injections in opposite quadrants, although gaps remained. No statistically significant difference in coverage between IOPs of 10 and 35 mmHg was observed. Conclusions: Construction of a reliable custom-made injector system is feasible. IOP at the pressures measured did not appear to affect coverage of the suprachoroidally injected ICG dye solution.
- 1 November 2025
- Published by SAGE Publications in Journal of Ocular Pharmacology and Therapeutics
- Vol. 41 (9) , 544-553
Custom-Made Injector for Suprachoroidal Ocular Delivery: Effect of Intraocular Pressure, Volume, and Location on the Distribution of Aqueous Solutions in Rabbits
Purpose: Develop a custom-made injector system for delivery of aqueous solutions to the suprachoroidal space (SCS). And to test the effect of intraocular pressure (IOP), volume, and location on distribution. Methods: SCS injectors were produced in the laboratory using readily available components. Fifty 100 µL of either fluorescein sodium and/or indocyanine green (ICG) dye solutions were injected 6-mm posterior to the corneal limbus in either the superotemporal or inferonasal quadrants of the eyes of albino rabbits. Coverage of the injected dyes was documented in vivo. Distribution of 50- and 100-µL single-injection volumes was compared, as were 50-µL injections in two opposing quadrants. The vasoconstrictor endothelin-1 was injected into some eyes as a test of efficacy. To determine the possible effects of IOP on injection coverage, both eyes of 6 rabbits were injected with ICG in a crossover design with the IOPs of the eyes held manometrically at either 10 or 35 mmHg. Results: Successful SCS injections, as determined by fundus imaging, were done in more than 40 rabbit eyes [as well as 40 nonhuman primate eyes in separate studies]. One hundred microliters single injections provided better coverage than 50 µL, but the most complete coverage was with two 50-µL injections in opposite quadrants, although gaps remained. No statistically significant difference in coverage between IOPs of 10 and 35 mmHg was observed. Conclusions: Construction of a reliable custom-made injector system is feasible. IOP at the pressures measured did not appear to affect coverage of the suprachoroidally injected ICG dye solution.
- 10 February 2023
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 146 (2) , 97-112
Multifocal electroretinography increases following experimental glaucoma in nonhuman primates with retinal ganglion cell axotomy
Purpose To determine whether short-latency changes in multifocal electroretinography (mfERG) observed in experimental glaucoma (EG) are secondary solely to retinal ganglion cell (RGC) loss or whether there is a separate contribution from elevated intraocular pressure (IOP). Methods Prior to operative procedures, a series of baseline mfERGs were recorded from six rhesus macaques using a 241-element unstretched stimulus. Animals then underwent hemiretinal endodiathermy axotomy (HEA) by placing burns along the inferior 180° of the optic nerve margin in the right eye (OD). mfERG recordings were obtained in each animal at regular intervals following for 3–4 months to allow stabilization of the HEA effects. Laser trabecular meshwork destruction (LTD) to elevate IOP was then performed; first-order kernel (K1) waveform root-mean-square (RMS) amplitudes for the short-latency segment of the mfERG wave (9–35 ms) were computed for two 7-hexagon groupings—the first located within the superior (non-axotomized) macula and the second within the inferior (axotomized) macula. Immunohistochemistry for glial fibrillary acidic protein (GFAP) was done. Results By 3 months post HEA, there was marked thinning of the inferior nerve fiber layer as measured by optical coherence tomography. Compared with baseline, no statistically significant changes in 9–35 ms K1 RMS amplitudes were evident in either the axotomized or non-axotomized portions of the macula. Following LTD, mean IOP in HEA eyes rose to 46 ± 9 compared with 20 ± 2 mmHg (SD) in the fellow control eyes. In the HEA + EG eyes, statistically significant increases in K1 RMS amplitude were present in both the axotomized inferior and non-axotomized superior portions of the OD retinas. No changes in K1 RMS amplitude were found in the fellow control eyes from baseline to HEA epoch, but there was a smaller increase from baseline to HEA + EG. Upregulation of GFAP in the Müller cells was evident in both non-axotomized and axotomized retina in eyes with elevated IOP. Conclusions The RMS amplitudes of the short-latency mfERG K1 waveforms are not altered following axotomy but undergo marked increases following elevated IOP. This suggests that the increase in mfERG amplitude was not solely a result of RGC loss and may reflect photoreceptor and bipolar cell dysfunction and/or changes in Müller cells.
- 10 February 2023
- Published by Springer Nature in Documenta Ophthalmologica
- Vol. 146 (2) , 97-112
Multifocal electroretinography increases following experimental glaucoma in nonhuman primates with retinal ganglion cell axotomy
Purpose To determine whether short-latency changes in multifocal electroretinography (mfERG) observed in experimental glaucoma (EG) are secondary solely to retinal ganglion cell (RGC) loss or whether there is a separate contribution from elevated intraocular pressure (IOP). Methods Prior to operative procedures, a series of baseline mfERGs were recorded from six rhesus macaques using a 241-element unstretched stimulus. Animals then underwent hemiretinal endodiathermy axotomy (HEA) by placing burns along the inferior 180° of the optic nerve margin in the right eye (OD). mfERG recordings were obtained in each animal at regular intervals following for 3–4 months to allow stabilization of the HEA effects. Laser trabecular meshwork destruction (LTD) to elevate IOP was then performed; first-order kernel (K1) waveform root-mean-square (RMS) amplitudes for the short-latency segment of the mfERG wave (9–35 ms) were computed for two 7-hexagon groupings—the first located within the superior (non-axotomized) macula and the second within the inferior (axotomized) macula. Immunohistochemistry for glial fibrillary acidic protein (GFAP) was done. Results By 3 months post HEA, there was marked thinning of the inferior nerve fiber layer as measured by optical coherence tomography. Compared with baseline, no statistically significant changes in 9–35 ms K1 RMS amplitudes were evident in either the axotomized or non-axotomized portions of the macula. Following LTD, mean IOP in HEA eyes rose to 46 ± 9 compared with 20 ± 2 mmHg (SD) in the fellow control eyes. In the HEA + EG eyes, statistically significant increases in K1 RMS amplitude were present in both the axotomized inferior and non-axotomized superior portions of the OD retinas. No changes in K1 RMS amplitude were found in the fellow control eyes from baseline to HEA epoch, but there was a smaller increase from baseline to HEA + EG. Upregulation of GFAP in the Müller cells was evident in both non-axotomized and axotomized retina in eyes with elevated IOP. Conclusions The RMS amplitudes of the short-latency mfERG K1 waveforms are not altered following axotomy but undergo marked increases following elevated IOP. This suggests that the increase in mfERG amplitude was not solely a result of RGC loss and may reflect photoreceptor and bipolar cell dysfunction and/or changes in Müller cells.
- 1 November 2015
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 141 (11) , 1021-1022
Hyponatremia and Right Maxillary Sinus Mass
Clinical Challenge from JAMA Otolaryngology–Head & Neck Surgery — Hyponatremia and Right Maxillary Sinus Mass
- 1 November 2015
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 141 (11) , 1021-1022
Hyponatremia and Right Maxillary Sinus Mass
Clinical Challenge from JAMA Otolaryngology–Head & Neck Surgery — Hyponatremia and Right Maxillary Sinus Mass