Gaofei Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gaofei Jin has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Xiran Cai
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
3 shared publications Hui Zhu
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications- Baosheng Wang
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication - Chenzhe Li
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication - Daohuai Jiang
Key Laboratory of Optoelectronic Science and Technology for Medicine Ministry of Education Fujian Provincial Key Laboratory for Photonics Technology Fujian Normal University 350117 Fuzhou China
1 shared publication - Dean Ta
Fudan University
1 shared publication
Latest Publications
- 15 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108198
Transcranial ultrasound tomography for neonatal brain imaging: A feasibility study
- 15 June 2026
- Published by Elsevier in Ultrasonics
- Vol. 167, 108198
Transcranial ultrasound tomography for neonatal brain imaging: A feasibility study
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 920-931
Single Probe Enabled Refraction-Corrected Transcranial Passive Acoustic Mapping Through Macaque Calvaria
In microbubble (MB) cavitation-mediated blood-brain barrier (BBB) opening, prior knowledge of the skull’s sound speed properties is required to correct phase aberration and achieve accurate localization of the cavitation source using transcranial passive acoustic mapping (TPAM). Current approaches predominantly rely on CT scans to generate an empirical sound speed map (SSM) for correction after registering the two imaging modalities. This increases hardware complexity and cost while introducing additional errors from the registration process and the empirical sound speed values in the SSM. Here, we propose an all-ultrasound, single-probe method for refraction-corrected TPAM. This method firstly deploys the head wave technique to reconstruct an approximate multi-layer SSM of the skull. This SSM is then combined with the heterogeneous angular spectrum approach for PAM to efficiently reconstruct refraction-corrected TPAM images. In the in-vitro hydrophone and MB cavitation experiments using two whole macaque calvariae, we showed that the source localization error could be reduced to a sub-millimeter scale with the proposed method in the area where the F-number is less than 1.2. Compared to the cases without phase aberration correction, the localization error was reduced by about 1.8 – 5.9 times in the corrected cases, clearly demonstrating the effectiveness of the proposed method for transcranial acoustic source localization. We also showed that the proposed method achieved comparable performance on correcting source localization to the CT-corrected method. These preliminary results suggest that our method represents a low-cost solution for monitoring transcranial MB cavitation activity, particularly in the cortical regions, which could facilitate the investigation of MB-mediated focused therapies in the brain and warrants further study for clinical translation.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (7) , 920-931
Single Probe Enabled Refraction-Corrected Transcranial Passive Acoustic Mapping Through Macaque Calvaria
In microbubble (MB) cavitation-mediated blood-brain barrier (BBB) opening, prior knowledge of the skull’s sound speed properties is required to correct phase aberration and achieve accurate localization of the cavitation source using transcranial passive acoustic mapping (TPAM). Current approaches predominantly rely on CT scans to generate an empirical sound speed map (SSM) for correction after registering the two imaging modalities. This increases hardware complexity and cost while introducing additional errors from the registration process and the empirical sound speed values in the SSM. Here, we propose an all-ultrasound, single-probe method for refraction-corrected TPAM. This method firstly deploys the head wave technique to reconstruct an approximate multi-layer SSM of the skull. This SSM is then combined with the heterogeneous angular spectrum approach for PAM to efficiently reconstruct refraction-corrected TPAM images. In the in-vitro hydrophone and MB cavitation experiments using two whole macaque calvariae, we showed that the source localization error could be reduced to a sub-millimeter scale with the proposed method in the area where the F-number is less than 1.2. Compared to the cases without phase aberration correction, the localization error was reduced by about 1.8 – 5.9 times in the corrected cases, clearly demonstrating the effectiveness of the proposed method for transcranial acoustic source localization. We also showed that the proposed method achieved comparable performance on correcting source localization to the CT-corrected method. These preliminary results suggest that our method represents a low-cost solution for monitoring transcranial MB cavitation activity, particularly in the cortical regions, which could facilitate the investigation of MB-mediated focused therapies in the brain and warrants further study for clinical translation.
- Open Access
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 77-81
3D Frequency-Domain Full Waveform Inversion for Whole-Breast Imaging With a Multi-Row Ring Array
For ring-array ultrasound tomography, two-dimensional frequency-domain full waveform inversion is the clinical gold standard for high-resolution imaging of the breast. While yielding high-resolution images in the plane of the ring-array, the resulting slice-wise approach yields lower resolution out of plane when used to reconstruct the full volume. Instead, this work proposes a fully three-dimensional full-waveform inversion based on a multi-row ring-array transducer to improve out-of-plane resolution, while using cylindrical-wave transmissions to minimize acquisition and reconstruction time. For each numerical breast phantom tested, the root-mean-square error of three-dimensional full-waveform inversion is less than that of two-dimensional slice-wise full-waveform inversion by 6.3-13.7 m/s.
- 14 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 5, 77-81
Open Access3D Frequency-Domain Full Waveform Inversion for Whole-Breast Imaging With a Multi-Row Ring Array
For ring-array ultrasound tomography, two-dimensional frequency-domain full waveform inversion is the clinical gold standard for high-resolution imaging of the breast. While yielding high-resolution images in the plane of the ring-array, the resulting slice-wise approach yields lower resolution out of plane when used to reconstruct the full volume. Instead, this work proposes a fully three-dimensional full-waveform inversion based on a multi-row ring-array transducer to improve out-of-plane resolution, while using cylindrical-wave transmissions to minimize acquisition and reconstruction time. For each numerical breast phantom tested, the root-mean-square error of three-dimensional full-waveform inversion is less than that of two-dimensional slice-wise full-waveform inversion by 6.3-13.7 m/s.
- Open Access
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (8) , 2350-2361
Deep-Learning-Enabled Microwave-Induced Thermoacoustic Tomography Based on ResAttU-Net for Transcranial Brain Hemorrhage Detection
Objective: Hemorrhagic stroke is a leading threat to human's health. The fast-developing microwave-induced thermoacoustic tomography (MITAT) technique holds potential to do brain imaging. However, transcranial brain imaging based on MITAT is still challenging due to the involved huge heterogeneity in speed of sound and acoustic attenuation of human skull. This work aims to address the adverse effect of the acoustic heterogeneity using a deep-learning-based MITAT (DL-MITAT) approach for transcranial brain hemorrhage detection. Methods: We establish a new network structure, a residual attention U-Net (ResAttU-Net), for the proposed DL-MITAT technique, which exhibits improved performance as compared to some traditionally used networks. We use simulation method to build training sets and take images obtained by traditional imaging algorithms as the input of the network. Results: We present ex-vivo transcranial brain hemorrhage detection as a proof-of-concept validation. By using an 8.1-mm thick bovine skull and porcine brain tissues to perform ex-vivo experiments, we demonstrate that the trained ResAttU-Net is capable of efficiently eliminating image artifacts and accurately restoring the hemorrhage spot. It is proved that the DL-MITAT method can reliably suppress false positive rate and detect a hemorrhage spot as small as 3 mm. We also study effects of several factors of the DL-MITAT technique to further reveal its robustness and limitations. Conclusion: The proposed ResAttU-Net-based DL-MITAT method is promising for mitigating the acoustic inhomogeneity issue and performing transcranial brain hemorrhage detection. Significance: This work provides a novel ResAttU-Net-based DL-MITAT paradigm and paves a compelling route for transcranial brain hemorrhage detection as well as other transcranial brain imaging applications.
- 10 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (8) , 2350-2361
Open AccessDeep-Learning-Enabled Microwave-Induced Thermoacoustic Tomography Based on ResAttU-Net for Transcranial Brain Hemorrhage Detection
Objective: Hemorrhagic stroke is a leading threat to human's health. The fast-developing microwave-induced thermoacoustic tomography (MITAT) technique holds potential to do brain imaging. However, transcranial brain imaging based on MITAT is still challenging due to the involved huge heterogeneity in speed of sound and acoustic attenuation of human skull. This work aims to address the adverse effect of the acoustic heterogeneity using a deep-learning-based MITAT (DL-MITAT) approach for transcranial brain hemorrhage detection. Methods: We establish a new network structure, a residual attention U-Net (ResAttU-Net), for the proposed DL-MITAT technique, which exhibits improved performance as compared to some traditionally used networks. We use simulation method to build training sets and take images obtained by traditional imaging algorithms as the input of the network. Results: We present ex-vivo transcranial brain hemorrhage detection as a proof-of-concept validation. By using an 8.1-mm thick bovine skull and porcine brain tissues to perform ex-vivo experiments, we demonstrate that the trained ResAttU-Net is capable of efficiently eliminating image artifacts and accurately restoring the hemorrhage spot. It is proved that the DL-MITAT method can reliably suppress false positive rate and detect a hemorrhage spot as small as 3 mm. We also study effects of several factors of the DL-MITAT technique to further reveal its robustness and limitations. Conclusion: The proposed ResAttU-Net-based DL-MITAT method is promising for mitigating the acoustic inhomogeneity issue and performing transcranial brain hemorrhage detection. Significance: This work provides a novel ResAttU-Net-based DL-MITAT paradigm and paves a compelling route for transcranial brain hemorrhage detection as well as other transcranial brain imaging applications.
- 26 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (3) , 253-265
A Signal-Domain Object Segmentation Method for Ultrasound and Photoacoustic Computed Tomography
Image segmentation is important in improving the diagnostic capability of ultrasound computed tomography (USCT) and photoacoustic computed tomography (PACT), as it can be included in the image reconstruction process to improve image quality and quantification abilities. Segmenting the imaged object out of the background using image domain methods is easily complicated by low contrast, noise, and artifacts in the reconstructed image. Here, we introduce a new signal domain object segmentation method for USCT and PACT which does not require image reconstruction beforehand and is automatic, robust, computationally efficient, accurate, and straightforward. We first establish the relationship between the time-of-flight (TOF) of the received first arrival waves and the object’s boundary which is described by ellipse equations. Then, we show that the ellipses are tangent to the boundary. By looking for tangent points on the common tangent of neighboring ellipses, the boundary can be approximated with high fidelity. Imaging experiments of human fingers and mice cross sections showed that our method provided equivalent or better segmentations than the optimal ones by active contours. In summary, our method greatly reduces the overall complexity of object segmentation and shows great potential in eliminating user dependency without sacrificing segmentation accuracy. The method can be further seamlessly incorporated into algorithms for other processing purposes in USCT and PACT, such as high-quality image reconstruction.
- 26 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (3) , 253-265
A Signal-Domain Object Segmentation Method for Ultrasound and Photoacoustic Computed Tomography
Image segmentation is important in improving the diagnostic capability of ultrasound computed tomography (USCT) and photoacoustic computed tomography (PACT), as it can be included in the image reconstruction process to improve image quality and quantification abilities. Segmenting the imaged object out of the background using image domain methods is easily complicated by low contrast, noise, and artifacts in the reconstructed image. Here, we introduce a new signal domain object segmentation method for USCT and PACT which does not require image reconstruction beforehand and is automatic, robust, computationally efficient, accurate, and straightforward. We first establish the relationship between the time-of-flight (TOF) of the received first arrival waves and the object’s boundary which is described by ellipse equations. Then, we show that the ellipses are tangent to the boundary. By looking for tangent points on the common tangent of neighboring ellipses, the boundary can be approximated with high fidelity. Imaging experiments of human fingers and mice cross sections showed that our method provided equivalent or better segmentations than the optimal ones by active contours. In summary, our method greatly reduces the overall complexity of object segmentation and shows great potential in eliminating user dependency without sacrificing segmentation accuracy. The method can be further seamlessly incorporated into algorithms for other processing purposes in USCT and PACT, such as high-quality image reconstruction.