  • Effectiveness of Implantable Doppler Probe Versus Standard Clinical Care in Preventing Thrombosis-Related Graft Loss in Kidney Transplantation: A Systematic Review and Meta-Analysis

    by Muhammad Shahzar Malik, Zain-ul Abideen, Kris Houlberg, Jacob A. Akoh

    Objectives: The implantable Doppler probe can monitor the patency of vascular anastomosis, thereby facilitating early detection of vascular thrombosis critical to reducing graft loss. In this study, we examined the effectiveness of this technology compared with standard clinical care in reducing thrombosis-related graft loss and the requirement for color duplex ultrasonography in the first 24 hours postoperatively by a medical literature search of the application of this technology in kidney transplantation. Materials and Methods: We conducted a systematic search (January 15, 2024) of a wide range of experimental and observational studies that comprised kidney transplant recipients monitored with blood flow sensing technology (intervention group) and standard clinical care (control group). Primary outcomes were differences between groups of thrombosis-related graft loss and surveillance requirement of color duplex ultrasonography scans in the first 24 hours postoperatively. Two independent researchers conducted critical appraisal and data extraction of the selected papers using the Joanna Briggs Institute Meta-Analysis of Statistics Assessment and Review Instrument. We used a random effects model for the meta-analysis. Dichotomous outcomes were expressed as relative risk or odds ratio. Results: The search identified 43 articles. After exclusion criteria, 7 studies (1 experimental, 6 observational) were included, with a total participant sample of 874 adult kidney transplant recipients with and without blood flow sensing technology. The certainty of evidence level was rated as moderate. Blood flow sensing technology resulted in a 66% reduction in the risk of thrombosis-related graft loss and a 61% lower probability of requiring color duplex ultrasonography in the first 24 hours postoperatively compared with standard clinical care. Conclusions: Blood flow sensing technology can be used as a helpful adjunct in the postoperative monitoring of kidney transplant recipients. However, given the technical limitations, signals should be interpreted alongside the traditional clinical assessment techniques.

  • Experiences of Participation in a Study Investigating Feasibility of the Implantable Doppler Probe in Kidney Transplantation: An Embedded Qualitative Study

    by Muhammad Shahzar Malik, Kris Houlberg, Jacob A. Akoh

    Objectives: Kidney transplant survival can be improved with better graft surveillance postoperatively. In the quest to explore new technologies, we explored the feasibility of an implantable Doppler probe as a blood flow monitoring device in kidney transplant patients. This qualitative study was embedded in a feasibility trial and aimed to test the device's clinical acceptability and obtain suggestions for the development of the intervention. Objectives included exploring the experiences of feasibility study participants and identifying barriers to the implementation of implantable Doppler probes in clinical practice. Materials and Methods: We conducted semi -structured interviews containing open-ended questions with 12 feasibility study participants recruited by purposive sampling. All interviews were audio -recorded with verbatim transcription. Thematic data analysis was performed at the latent level by using an inductive approach with a previously published 6 -phase guide. Results: Three key themes emerged: (1) perceived value of the intervention in clinical practice, (2) challenges and barriers to implementation of the intervention, and (3) suggestions for the development of the intervention. Due to functional limitations and lack of research, medical professional participants revealed clinical equipoise regarding the utility of implantable Doppler probes. However, the device was well received by patient participants. Challenges included device training needs for medical professionals and educational sessions for patients. Innovative ideas for development included the insertion of a display screen, adopting disposable units to reduce overall cost, online access allowing remote monitoring, decreasing external monitoring unit size, and integrating a wireless connection with the probe to reduce signal errors and increase patient safety. Conclusions: The clinical need for blood flow sensing technology in kidney transplants has been widely acknowledged. Implantable Doppler probes may be a beneficial adjunct in the early postoperative surveillance of kidney transplant patients. However, the device's technical limitations are the main challenges to its acceptance in clinical practice.


  • Exploring the Role of an Implantable Doppler Probe as a Blood Flow-Monitoring Device in Kidney Transplant: A Feasibility Randomized Controlled Trial

    by Muhammad Shahzar Malik, Kris Houlberg, Jacob A. Akoh

    Objectives: Vascular thrombosis is a disastrous postoperative complication resulting in the loss of 3.5% to 5.7% of all kidney transplants. The use of blood flow-sensing technology in the early postoperative period may help in the early identification of vascular complications crucial to reducing graft loss. This study aimed to assess the feasibility of an implantable Doppler probe as a blood flow-monitoring device in kidney transplant recipients and to evaluate its usefulness in the prevention of early graft loss. Materials and Methods: This 2-arm feasibility randomized controlled trial compared the demographic characteristics and surgical outcomes of kidney transplant recipients who received implantable Doppler probe monitoring (intervention group; n = 30) with those who had standard clinical care (control group; n = 30). Surgical outcomes compared between the groups included the number of early vascular complications identified, the number of departmental ultrasonography scans requested in the first 72 hours postoperatively, and month 3 graft loss. Results: Both groups were similar in demographic characteristics. In the intervention group versus the control group, fewer ultrasonography scans were requested in the first 24 hours postoperatively (56% vs 91%) and lower graft loss (0% vs 6.6%) was recorded. The results addressed uncertainties around the feasibility study's research methods and required resources for a future pragmatic trial. Conclusions: An implantable Doppler probe may be a beneficial adjunct for graft monitoring after kidney transplants. This feasibility study provided the necessary preliminary information and filled initial gaps in the evidence that can inform future research. The prespecified progression criteria of the study were fulfilled. The study template used can be transferable to other transplant centers across the United Kingdom. A pragmatic large-scale randomized controlled trial is warranted to evaluate the effectiveness of implantable Doppler probes in clinical practice.


  • Exploring the Risk Factors and Preventable Measures for Early Graft Loss in Kidney Transplantation: A Single-Center Analysis in the Southwest of the United Kingdom

    by Muhammad Shahzar Malik, Jacob Akoh, Kris Houlberg

    Objectives: Early graft loss due to vascular complications occurs in 3.5% to 5.7% of total kidney transplants. Two strategies to improve kidney graft outcomes have been advocated: (1) meticulous attention to modifiable risk factors and (2) exploration of monitoring technologies that assist in the early detection of vascular complications critical to rescue of a compromised graft. This study aimed to assess risk factors and preventable measures for early graft loss in kidney transplant recipients from the Southwest of UK. Materials and Methods: In this retrospective observational study, the demographic characteristics, comorbidities, and use of a postoperative blood flow monitoring device in 472 kidney transplant recipients at the Southwest Transplant Centre between January 2015 and March 2023 were analyzed individually against early graft loss. We conducted bivariate analyses using chi-square tests with a contingency table to identify whether recipient risk factors (demographic characteristics, comorbidities) or the use of an implantable blood flow monitoring device was significantly associated with early graft loss. Results: Twelve transplant recipients (2.5%) had early graft loss due to vascular complications. The results revealed that recipient's smoking habit, the number of prior kidney transplants, and a history of thromboembolism displayed a statistically significant association with early graft loss. Conversely, the use of an implantable blood flow monitoring device in kidney transplant recipients did not display a statistically significant association with early graft loss. Conclusions: Meticulous attention given to controlling risk factors before kidney transplant can reduce early graft loss. Surveillance by clinical observation and serial radiological monitoring can be offered to patients at high risk with nonmodifiable risk factors. Further controlled studies are warranted to evaluate the implantable blood flow monitoring device in clinical practice.


  • A Study Protocol Exploring the Role of an Implantable Doppler Probe in Kidney Transplantation: A Feasibility Randomized Controlled Trial with an Embedded Qualitative Study

    by Muhammad Shahzar Malik, Jacob A. Akoh, Kris Houlberg

    Objectives: Vascular complications in kidney transplant surgery constitute one-third of early graft loss, which can be prevented by timely diagnosis of vascular compromise. A blood flow monitoring device may have a beneficial role in the early identification of graft hypoperfusion critical to reducing graft loss. This research protocol aims to evaluate the potential of an implantable Doppler probe as a blood flow monitoring device in kidney transplant recipients. Materials and Methods: The potential study will be a mixed methodology, 2-arm feasibility randomized controlled trial with an embedded qualitative study. For the trial, we will compare demographic characteristics and outcome measures of kidney transplant patients receiving implantable Doppler probe monitoring (intervention group, n = 30) with those having standard clinical care (control group). For the qualitative study, we will conduct semi-structured interviews with stakeholders (n = 12) recruited by purposive sampling to explore experiences of participants. All interviews will be audio recorded with verbatim transcription. Results: Our results will use the summarized quantitative data and descriptive statistics to determine differences between the groups. We will use CONSORT guidelines to determine the suitability of the research processes, availability of research resources, and potential challenges faced during the feasibility randomized controlled trial. We will use thematic analysis and NVivo software to analyze the acceptability of the intervention in clinical practice. We will compile the results according to the consolidated criteria for reporting qualitative research checklist. Conclusions: The goal of this protocol is to determine the feasibility of an implantable Doppler probe monitoring device in kidney transplant recipients. The feasibility study will collect preliminary information, fill gaps in evidence, and test research processes for the pragmatic future randomized controlled trial. The template of this study is transferable to other transplant centers across the United Kingdom.


  • Iliofemoral Polytetrafluoroethylene Graft Interposition: A Rescue Procedure in External Iliac Artery Dissection to Restore Lower Limb Revascularization and Salvage Kidney Transplant

    by Muhammad Shahzar Malik, Jacob A. Akoh, Kris Houlberg, Jaime Barwell, Richard Powell

    External iliac artery dissection is a catastrophic complication during kidney transplant surgery. We present a technically challenging case of external iliac artery dissection that occurred in severely atherosclerotic vessels of a high-risk patient receiving his third kidney transplant. The intimal dissection constituted by the upstream application of a vascular clamp during the preparatory dissection ofthe vessels and progressed rapidly along the iliofemoral axis. The external iliac artery was severely diseased and in an irreparable condition, hence ligated and removed. After a common iliac endarterectomy, an iliofemoral polytetrafluoroethylene vascular graft interposition was performed. The transplant kidney was anastomosed directly on the vascular graft. Satisfactory lower limb vascularization and kidney transplant perfusion were achieved withouttechnical difficulties. The patient had an uneventful recovery without complications. The kidney transplant recipient retained stable graft function at 6 months postoperatively. This rare case highlights the benefit of a surgical strategy in a vascular emergency that threatens the lower limb during a kidney transplant, and we emphasize the technical details of the procedure. As patients with extended indications are accepted onto the transplant waiting list, it is important for transplant surgeons to acquire surgical skills of vascular graft interposition. A postoperative blood flow monitoring device may be beneficial in high-risk kidney transplant cases.


  • Exploring Views and Expectations of Clinicians, Nurses, and Kidney Transplant Recipients Regarding Protocol Development of a Study to Investigate Feasibility of the Implantable Doppler Probe in Kidney Transplantation: Patient-Public Involvement Consultations

    by Muhammad Shahzar Malik, Zain-Ul Abideen, Jacob A. Akoh, Kris Houlberg

    Objectives: The shortage of donor organs is the most limiting factor in kidney transplant practice today. New monitoring technologies are being investigated to reduce graft loss due to vascular complications. We assessed the feasibility of a novel blood flow monitoring device, the implantable Doppler probe, in kidney transplant surgery. This patient-public involvement consultation explored the views and expectations of the stakeholders (kidney transplant recipients, surgeons, clinicians, and nurses with direct experience of the implantable Doppler probe) on the protocol development of our feasibility study. Our objective was to improve the protocol, understand stakeholder perceptions regarding research in postoperative graft surveillance, and identify potential confounding factors to the research and challenges to implementation of implantable Doppler probe in clinical practice. Materials and Methods: We conducted semi-structured interviews containing open-ended questions with 12 stakeholders. We performed thematic analysis of the data at the latent level by an inductive approach according to a 6-phase guide by Braun and Clarke using NVivo 12 software. Results: Three key themes emerged. (1) Experiences with the implantable Doppler probe as a monitoring device showed that it was well received by the patients; however, there was a clinical equipoise among the health care professionals. (2) Recognition of the need for research in the early postoperative graft monitoring displayed stakeholder understanding regarding the role of a blood flow monitoring device to improve surgical outcomes. (3) Recommendations for smooth conduct of the proposed study include suggestions for improvement of the study protocol, informative sessions for the patients and nurses, and innovative ideas to improve the monitoring device. Conclusions: Patient-public involvement consultation was crucial for the research design of our proposed feasibility study. Useful strategies and a patient-centered approach were incorporated to mitigate the potential challenges to the conduct of the research.


  • The Use of the Implantable Doppler Probe as a Blood Flow Monitoring Device in Clinical Settings: A Narrative Review of the Evidence

    by Muhammad Shahzar Malik, Jacob A. Akoh, Kris Houlberg

    In the past decade, the implantable Doppler probe has been studied widely as a blood flow-monitoring device in reconstructive and transplant surgical specialities. Its utility as an effective postoperative monitoring technique is still debatable, with no clear guidelines in clinical practice. Here, we mapped the current evidence on the usefulness of the implantable Doppler probe as a blood flow-monitoring device. The objective was to present an up-to-date assessment of the benefits and limitations of using implantable Doppler probes in clinical and experimental clinical settings. We conducted a literature search using the Cochrane Library and Healthcare Databases Advanced Search and using implantable Doppler probe, transplant, graft, and flap as key words. The search yielded 184 studies, with 73 studies included after exclusions. We evaluated, synthesized, and summarized the evidence from the studies in tabular form. There is clinical equipoise regarding the effectiveness of implantable Doppler probe as a flow sensing technique. The main reason is the lack of information and gaps in the evidence regarding the benefits and limitations of using implantable Doppler probes in clinical practice. The implantable Doppler probe has the potentialto be used as an adjunctpostoperativeblood flow-monitoring device. However, keeping in view of technical limitations, its signals should be interpreted alongside traditional clinical assessment techniques to determine the patency of microvascular anastomosis. Although evidence in this review will inform clinical practice in transplant and reconstructive surgical specialties, a prospective randomized controlled study with a larger patient cohort is required to evaluate the effectiveness of this probe in clinical settings.