Kazumasa Kurogi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kazumasa Kurogi has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
Nobuyasu Yamamoto
Department of Cardiology Miyazaki Prefectural Nobeoka Hospital Nobeoka Japan
6 shared publications- Soichi Komaki
Division of Cardiovascular Medicine and Nephrology, Department of Internal Medicine, Faculty of Medicine University of Miyazaki Miyazaki Japan
3 shared publications - Yunosuke Matsuura
Division of Cardiovascular Medicine and Nephrology, Department of Internal Medicine, Faculty of Medicine, University of Miyazaki
3 shared publications Hiroki Tanaka
Division of Cardiovascular Medicine and Nephrology, Department of Internal Medicine, Faculty of Medicine, University of Miyazaki, Japan
2 shared publications- Katsuyuki Hasegawa
Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Hyogo 6650873, Japan
2 shared publications - Kenichi Tsujita
Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University , Kumamoto
2 shared publications
Latest Publications
- 6 November 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
When the RotaWire Crosses but Cannot Advance: Dual‐Lumen Microcatheter–Assisted RotaWire Delivery
RotaWire delivery can be challenging in severely calcified device‐uncrossable coronary lesions when conventional wire exchange through a microcatheter is not feasible. We report a 76‐year‐old man with a severely calcified mid‐left anterior descending coronary artery (LAD) lesion in which neither a microcatheter nor a 0.75 mm balloon could cross. A second channel was created using a penetration wire through a dual‐lumen microcatheter, allowing direct RotaWire crossing. However, the RotaWire could not be advanced sufficiently into the distal LAD. After intentional proximal pullback of the dual‐lumen microcatheter, the microcatheter and RotaWire were held together and advanced as a single unit, enabling adequate distal RotaWire positioning and successful rotational atherectomy. This case highlights a distinct challenge after successful direct RotaWire crossing and demonstrates coupled advancement with a dual‐lumen microcatheter as a potential bailout technique when distal RotaWire advancement remains difficult.
- 6 November 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
When the RotaWire Crosses but Cannot Advance: Dual‐Lumen Microcatheter–Assisted RotaWire Delivery
RotaWire delivery can be challenging in severely calcified device‐uncrossable coronary lesions when conventional wire exchange through a microcatheter is not feasible. We report a 76‐year‐old man with a severely calcified mid‐left anterior descending coronary artery (LAD) lesion in which neither a microcatheter nor a 0.75 mm balloon could cross. A second channel was created using a penetration wire through a dual‐lumen microcatheter, allowing direct RotaWire crossing. However, the RotaWire could not be advanced sufficiently into the distal LAD. After intentional proximal pullback of the dual‐lumen microcatheter, the microcatheter and RotaWire were held together and advanced as a single unit, enabling adequate distal RotaWire positioning and successful rotational atherectomy. This case highlights a distinct challenge after successful direct RotaWire crossing and demonstrates coupled advancement with a dual‐lumen microcatheter as a potential bailout technique when distal RotaWire advancement remains difficult.
- Open Access
- 19 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (9)
A transformer-based deep learning model for predicting the use of atherectomy devices during PCI from preprocedural cardiac computed tomography angiography
Aims: Severe coronary calcification complicates percutaneous coronary intervention (PCI), often necessitating atherectomy-based debulking devices that increase procedural complexity and risk. We aimed to develop and externally validate a Transformer-based deep learning model using preprocedural cardiac computed tomography angiography (CCTA) to predict atherectomy device use during PCI and compare its performance with that of blinded human readers, including general cardiologists and PCI experts. Methods and results: This retrospective multicentre study included 498 calcified coronary lesions from 419 patients who underwent PCI after preprocedural CCTA. Data from 12 institutions were used for training and validation with four-fold cross-validation, and data from two independent institutions (97 lesions) served as an external test cohort. The model combined a convolutional neural network feature extractor with Transformer-based multiple instance learning, and clinical variables were evaluated for incremental value. In the external test cohort, the CCTA-only model achieved an area under the receiver operating characteristic curve (AUC) of 0.788 (95% confidence interval [CI], 0.691–0.873) for predicting atherectomy device use. Adding clinical variables resulted in an AUC of 0.805 (95% CI, 0.713–0.886), indicating limited incremental value. In the reader comparison, the model showed higher accuracy than general cardiologists (0.742 vs. 0.619; P = 0.029) and numerically similar accuracy to PCI experts (0.742 vs. 0.670; P = 0.230). Conclusion: A Transformer-based deep learning model using preprocedural CCTA showed clinically relevant performance for predicting atherectomy device use during PCI in an independent external test cohort. These findings suggest that the model may support lesion assessment and procedural planning.
- 19 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 7 (9)
Open AccessA transformer-based deep learning model for predicting the use of atherectomy devices during PCI from preprocedural cardiac computed tomography angiography
Aims: Severe coronary calcification complicates percutaneous coronary intervention (PCI), often necessitating atherectomy-based debulking devices that increase procedural complexity and risk. We aimed to develop and externally validate a Transformer-based deep learning model using preprocedural cardiac computed tomography angiography (CCTA) to predict atherectomy device use during PCI and compare its performance with that of blinded human readers, including general cardiologists and PCI experts. Methods and results: This retrospective multicentre study included 498 calcified coronary lesions from 419 patients who underwent PCI after preprocedural CCTA. Data from 12 institutions were used for training and validation with four-fold cross-validation, and data from two independent institutions (97 lesions) served as an external test cohort. The model combined a convolutional neural network feature extractor with Transformer-based multiple instance learning, and clinical variables were evaluated for incremental value. In the external test cohort, the CCTA-only model achieved an area under the receiver operating characteristic curve (AUC) of 0.788 (95% confidence interval [CI], 0.691–0.873) for predicting atherectomy device use. Adding clinical variables resulted in an AUC of 0.805 (95% CI, 0.713–0.886), indicating limited incremental value. In the reader comparison, the model showed higher accuracy than general cardiologists (0.742 vs. 0.619; P = 0.029) and numerically similar accuracy to PCI experts (0.742 vs. 0.670; P = 0.230). Conclusion: A Transformer-based deep learning model using preprocedural CCTA showed clinically relevant performance for predicting atherectomy device use during PCI in an independent external test cohort. These findings suggest that the model may support lesion assessment and procedural planning.
- Open Access
- 30 September 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (46)
Subintimal Transcatheter Withdrawal for Active Decompression of Stent-Induced Coronary Intramural Hematoma Under Intravascular Ultrasound Guidance
- 30 September 2026
- Published by Elsevier in JACC: Case Reports
- Vol. 31 (46)
Open AccessSubintimal Transcatheter Withdrawal for Active Decompression of Stent-Induced Coronary Intramural Hematoma Under Intravascular Ultrasound Guidance
- 2 July 2025
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 19 (6) , 725-726
Coronary computed tomography angiography radiomics for predicting major adverse cardiovascular events after percutaneous coronary interventions
- 2 July 2025
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 19 (6) , 725-726
Coronary computed tomography angiography radiomics for predicting major adverse cardiovascular events after percutaneous coronary interventions
- 6 July 2024
- Published by Elsevier in The American Journal of Cardiology
- Vol. 226, 36-39
Real-Time Intravascular Ultrasound Guidance Versus Angiographic Guidance for Precise Left Anterior Descending Artery Ostial Stenting
- 6 July 2024
- Published by Elsevier in The American Journal of Cardiology
- Vol. 226, 36-39
Real-Time Intravascular Ultrasound Guidance Versus Angiographic Guidance for Precise Left Anterior Descending Artery Ostial Stenting
- Open Access
Nitroglycerin use preceding primary percutaneous coronary intervention is associated with adverse clinical outcomes in elderly patients with acute coronary syndrome
Background: The primary care for acute coronary syndrome (ACS) includes the administration of nitroglycerin (GTN). This study aimed to investigate the association between the use of GTN before percutaneous coronary intervention (PCI) for ACS and clinical outcomes. Methods and Results: Nine-hundred and forty-seven patients who underwent PCI for ACS were examined and classified into two groups: those who were treated with GTN before PCI (GTN group) and those who were not (non-GTN group). The incidence of major adverse cardiovascular events (MACE), which consist of all-cause mortality, myocardial infarction, stroke, and rehospitalization for heart failure at 1 year, was compared between the two groups. This study identified 289 patients with ACS who used GTN preceding PCI. Pre-PCI systolic blood pressure was significantly lower in the GTN group than in the non-GTN group (median (interquartile range); 130.0 (112.5-144.2) mmHg vs. 142.0 (115.0-160.0) mmHg, respectively, p = 0.03). Multivariate Cox regression analysis indicated that GTN use preceding PCI was an independent determinant for the incidence of MACE (hazard ratio, 1.64; 95% confidence interval, 1.17-2.31; p = 0.004). Overall, the incidence of MACE 1 year after PCI for ACS was significantly higher in the GTN group than in the non-GTN group (log-rank test, p = 0.02); however, this trend was consistently found in elderly patients aged ≥ 75 years (p = 0.002) but not in non-elderly patients aged < 75 years (p = 0.77). Conclusions: GTN use preceding PCI for ACS is associated with lower blood pressure and adverse clinical outcomes in elderly patients.
Open AccessNitroglycerin use preceding primary percutaneous coronary intervention is associated with adverse clinical outcomes in elderly patients with acute coronary syndrome
Background: The primary care for acute coronary syndrome (ACS) includes the administration of nitroglycerin (GTN). This study aimed to investigate the association between the use of GTN before percutaneous coronary intervention (PCI) for ACS and clinical outcomes. Methods and Results: Nine-hundred and forty-seven patients who underwent PCI for ACS were examined and classified into two groups: those who were treated with GTN before PCI (GTN group) and those who were not (non-GTN group). The incidence of major adverse cardiovascular events (MACE), which consist of all-cause mortality, myocardial infarction, stroke, and rehospitalization for heart failure at 1 year, was compared between the two groups. This study identified 289 patients with ACS who used GTN preceding PCI. Pre-PCI systolic blood pressure was significantly lower in the GTN group than in the non-GTN group (median (interquartile range); 130.0 (112.5-144.2) mmHg vs. 142.0 (115.0-160.0) mmHg, respectively, p = 0.03). Multivariate Cox regression analysis indicated that GTN use preceding PCI was an independent determinant for the incidence of MACE (hazard ratio, 1.64; 95% confidence interval, 1.17-2.31; p = 0.004). Overall, the incidence of MACE 1 year after PCI for ACS was significantly higher in the GTN group than in the non-GTN group (log-rank test, p = 0.02); however, this trend was consistently found in elderly patients aged ≥ 75 years (p = 0.002) but not in non-elderly patients aged < 75 years (p = 0.77). Conclusions: GTN use preceding PCI for ACS is associated with lower blood pressure and adverse clinical outcomes in elderly patients.
- 10 February 2023
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 17 (2) , 120-129
Mean density of computed tomography for predicting rotational atherectomy during percutaneous coronary intervention
- 10 February 2023
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 17 (2) , 120-129
Mean density of computed tomography for predicting rotational atherectomy during percutaneous coronary intervention
- Open Access
- 10 March 2022
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 4 (3) , Content3
Content
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 10 March 2022
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 4 (3) , Content3
Open AccessContent
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.