Paola Fata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paola Fata has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Kosar Khwaja
McGill University Health Centre
2 shared publications - Abdulaziz Alnumay
Division of Trauma and General Surgery, McGill University Health Centre, Montreal General Hospital Site, Montreal, Canada
1 shared publication - Alan J. Forster
Ottawa Hospital Research Institute, Ottawa, Ontario, Canada
1 shared publication Alexa L. Grudzinski
Department of Anesthesiology and Pain Medicine, University of Ottawa, Ottawa, ON, Canada
1 shared publication- Amanda Meliambro1 shared publication
- Amin Madani
Department of Surgery, University of Toronto, Toronto, Canada
1 shared publication
Latest Publications
- Top Cited Papers
- 1 February 2022
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 128 (2) , 244-257
Prehabilitation in adult patients undergoing surgery: an umbrella review of systematic reviews
- 1 February 2022
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 128 (2) , 244-257
Top Cited PapersPrehabilitation in adult patients undergoing surgery: an umbrella review of systematic reviews
- 5 January 2021
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (1) , 315-319
Feasibility of intraoperative angioembolization for trauma patients using C-arm digital subtraction angiography
Purpose Hemodynamically unstable trauma patients who would benefit from angioembolization (AE) typically also require emergent surgery for their injuries. The critical decision of transferring a patient to the operating room versus the interventional radiology (IR) suite can be bypassed with the advent of intra-operative AE (IOAE). Previously limited by the availability of costly rooms termed RAPTOR (resuscitation with angiography, percutaneous techniques and open repair) suites, it has been suggested that using C-arm digital subtraction angiography (DSA) is a comparable alternative. This case series aims to establish the feasibility and safety of IOAE. Methods We conducted a retrospective analysis of all trauma patients at our level 1 trauma center who underwent IOAE with a concomitant surgical intervention from January 2011 to May 2019. Descriptive analyses were conducted. Results A total of 49 patients (80% male, 44 ± 17 years, 92% blunt) underwent IOAE using the C-arm DSA during the study period. All but one patient underwent exploratory laparotomy, 56% of which underwent an additional surgical procedure (ex. exploratory thoracotomy, orthopedic). Either Gelfoam® (Pfizer, New York, USA) (90%), coils (2.0%), or a combination (8.2%) were used for embolization. Internal iliac embolization was performed in 88% of cases (59% bilateral). IOAE was successful in all but four cases (8.2%) and thirty-day mortality was 31%. Conclusion IOAE appears to be a feasible and safe management option in severe trauma patients with the advantage of concurrent operative intervention and ongoing active resuscitation with good success in hemorrhage control.
- 5 January 2021
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (1) , 315-319
Feasibility of intraoperative angioembolization for trauma patients using C-arm digital subtraction angiography
Purpose Hemodynamically unstable trauma patients who would benefit from angioembolization (AE) typically also require emergent surgery for their injuries. The critical decision of transferring a patient to the operating room versus the interventional radiology (IR) suite can be bypassed with the advent of intra-operative AE (IOAE). Previously limited by the availability of costly rooms termed RAPTOR (resuscitation with angiography, percutaneous techniques and open repair) suites, it has been suggested that using C-arm digital subtraction angiography (DSA) is a comparable alternative. This case series aims to establish the feasibility and safety of IOAE. Methods We conducted a retrospective analysis of all trauma patients at our level 1 trauma center who underwent IOAE with a concomitant surgical intervention from January 2011 to May 2019. Descriptive analyses were conducted. Results A total of 49 patients (80% male, 44 ± 17 years, 92% blunt) underwent IOAE using the C-arm DSA during the study period. All but one patient underwent exploratory laparotomy, 56% of which underwent an additional surgical procedure (ex. exploratory thoracotomy, orthopedic). Either Gelfoam® (Pfizer, New York, USA) (90%), coils (2.0%), or a combination (8.2%) were used for embolization. Internal iliac embolization was performed in 88% of cases (59% bilateral). IOAE was successful in all but four cases (8.2%) and thirty-day mortality was 31%. Conclusion IOAE appears to be a feasible and safe management option in severe trauma patients with the advantage of concurrent operative intervention and ongoing active resuscitation with good success in hemorrhage control.
- 22 June 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (2) , 861-871
Biologic mesh for repair of ventral hernias in contaminated fields: long-term clinical and patient-reported outcomes
Background Guidelines recommend biologic prosthetics for ventral hernia repair (VHR) in contaminated fields, yet long-term and patient-reported data are limited. We aimed to determine the long-term rate of hernia recurrence, and other clinical and patient-reported outcomes following the use of porcine small intestine submucosa (PSIS) for VHR in a contaminated field. Methods Consecutive patients undergoing open VHR with PSIS mesh in a contaminated field from 2004 to 2014 were prospectively evaluated for hernia recurrence and other post-operative complications. Multivariate logistic and Cox regression analyses identified predictors of hernia recurrence and surgical site infection. Patient-reported outcomes were evaluated using SF-36, Hernia-Related Quality-of-Life Survey (HerQLes) and Body Image Questionnaire instruments. Results Forty-six hernias were repaired in clean-contaminated [16 (35 %)], contaminated [11 (24 %)] and dirty [19 (41 %)] fields. Median follow-up was 47 months [interquartile range: 31–79] and all patients had greater than 12-month follow-up. Sixteen patients (35 %) were not re-examined. Incidence of surgical site events and surgical site infection were 43 % (n = 20) and 56 % (n = 25), respectively. American Society of Anesthesiologists score 3 or greater was an independent predictor of surgical site infection (odds ratio 5.34 [95 % confidence interval 1.01–41.80], p = 0.04). Hernia recurrence occurred in 61 % (n = 28) with a median time to diagnosis of 16 months [interquartile range 8–26]. After bridged repair, 16 of 18 patients (89 %) recurred, compared to 12 of 28 (43 %) when fascia was approximated (p < 0.01). Bridged repair was an independent predictor of recurrence (odds ratio 10.67 [95 % confidence interval 2.42–76.08], p < 0.01). Patients with recurrences had significantly worse scores on the SF-36 mental health component and self-perceived body image, whereas HerQLes scores were similar. Conclusions Hernia recurrences and wound infections are high with the use of biologic PSIS mesh in contaminated surgical fields. Careful consideration is warranted using this approach.
- 22 June 2016
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (2) , 861-871
Biologic mesh for repair of ventral hernias in contaminated fields: long-term clinical and patient-reported outcomes
Background Guidelines recommend biologic prosthetics for ventral hernia repair (VHR) in contaminated fields, yet long-term and patient-reported data are limited. We aimed to determine the long-term rate of hernia recurrence, and other clinical and patient-reported outcomes following the use of porcine small intestine submucosa (PSIS) for VHR in a contaminated field. Methods Consecutive patients undergoing open VHR with PSIS mesh in a contaminated field from 2004 to 2014 were prospectively evaluated for hernia recurrence and other post-operative complications. Multivariate logistic and Cox regression analyses identified predictors of hernia recurrence and surgical site infection. Patient-reported outcomes were evaluated using SF-36, Hernia-Related Quality-of-Life Survey (HerQLes) and Body Image Questionnaire instruments. Results Forty-six hernias were repaired in clean-contaminated [16 (35 %)], contaminated [11 (24 %)] and dirty [19 (41 %)] fields. Median follow-up was 47 months [interquartile range: 31–79] and all patients had greater than 12-month follow-up. Sixteen patients (35 %) were not re-examined. Incidence of surgical site events and surgical site infection were 43 % (n = 20) and 56 % (n = 25), respectively. American Society of Anesthesiologists score 3 or greater was an independent predictor of surgical site infection (odds ratio 5.34 [95 % confidence interval 1.01–41.80], p = 0.04). Hernia recurrence occurred in 61 % (n = 28) with a median time to diagnosis of 16 months [interquartile range 8–26]. After bridged repair, 16 of 18 patients (89 %) recurred, compared to 12 of 28 (43 %) when fascia was approximated (p < 0.01). Bridged repair was an independent predictor of recurrence (odds ratio 10.67 [95 % confidence interval 2.42–76.08], p < 0.01). Patients with recurrences had significantly worse scores on the SF-36 mental health component and self-perceived body image, whereas HerQLes scores were similar. Conclusions Hernia recurrences and wound infections are high with the use of biologic PSIS mesh in contaminated surgical fields. Careful consideration is warranted using this approach.