KXKexin Xiang

Kexin Xiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kexin Xiang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced fNIRS-Based MCI Detection via Resting-State and Task-State Integration With Spatial–Temporal Feature Reduction

    by Chutian Zhang, Hongjun Yang, Jiaxing Wang, Kexin Xiang, Jingyao Chen, Liang Peng, Chenyu Fan, Yi Wu, Zeng-Guang Hou

    Objective: Detection of mild cognitive impairment (MCI), a precursor to dementia, is critical for timely intervention. Functional near-infrared spectroscopy (fNIRS) offers non-invasive, cost-effective, and motion-tolerant brain activity monitoring, but existing machine learning approaches for MCI classification using fNIRS face two limitations: 1) underutilization of complementary information between resting-state and task-state data, and 2) high feature dimensionality relative to small sample sizes, limiting model robustness and generalizability. We propose a spatio-temporal feature engineering framework addressing these gaps. Methods: Resting-state fNIRS signals are processed via independent component analysis to derive subject-specific spatial filters, which are then clustered into a universal population-level filter set. This filter set isolates spatial features from task-state signals. Then, temporal feature selection combines variance-based and advanced methods to further reduce dimensionality by identifying discriminative task-evoked time points relevant to MCI detection. The framework integrates fNIRS spatial filtering (resting-state) and temporal selection (task-state) critical for MCI detection. Results: Validated on 104 participants, this framework achieved a single-run best of 90.91% accuracy for cognitively normal vs. MCI classification, with 91.07% feature dimensionality reduction, suggest the potential for generalizable MCI detection and efficient model retraining for expanding clinical data. Feature analysis reveals (1) universal spatial filters linked to MCI biomarkers and (2) temporal weights highlighting critical decision time points during cognitive tasks. Conclusion: By resolving the integration gap between resting-state neurovascular patterns with task-evoked hemodynamic dynamics while reducing dimensionality, the framework achieves higher accuracy and interpretability, advancing fNIRS-based MCI detection. Clinical impact: This preclinical study presents a fNIRS framework that achieves robust, interpretable MCI detection with significant feature dimensionality reduction. These properties are critical for developing practical, efficient screening tools suitable for deployment in primary care or community health settings, potentially enhancing accessible early dementia screening.

  • Brain-Controlled Robot Enables the Paraplegic Implement Autonomous Multimode Walk Training

    by Weiqun Wang, Tianyu Lin, Kexin Xiang, Xu Liang, Chutian Zhang, Zhen Lv, Shixin Ren, Yitao Jing, Jiaxing Wang, Weiguo Shi, et al.

    Implementation of the autonomous walk training plays an important role for patients with lower limb paralysis, which however is still an open question presently due to the extreme difficulty of accurately recognizing the patients’ motor intentions in a natural way. In this study, a brain-controlled robot system, mainly consisting of a noninvasive brain–computer interface (BCI) and an elaborately designed lower limb rehabilitation robot, was developed to enable the paralyzed patients to implement the autonomous multimode walk training. First, an enhanced motor imagery based BCI paradigm was designed to improve the subjects’ imagination abilities to generate more separable electroencephalogram (EEG) data. Then, a concept of reaction time was introduced to select the valid EEG samples, and a rhythm combination, consisting of the most complete related sensorimotor rhythms to date, was designed to fully consider their influence. The reaction time, the rhythm combination, and the key parameters of the EEG decoder were collaboratively optimized to realize accurate and robust recognition of the subjects’ motor intentions. Moreover, a human–computer mutual learning based coevolution strategy was proposed, by which the subject and the decoder can be regulated to suit each other to obtain the satisfactory online performance. Finally, the proposed methods were deployed on the brain-controlled robot system, by which multimode walk training can be implemented autonomously. 18 subjects including 9 paraplegic patients were recruited in the experiments, and all of them successfully implemented the autonomous walk training after only about 25 minutes in total for EEG data recording and model training.


  • A Multiposture Robot for Full Cycle Rehabilitation of Lower Limbs: Design and Autonomous Training

    by Weiqun Wang, Weiguo Shi, Kexin Xiang, Shixin Ren, Tianyu Lin, Shengda Liu, Xu Liang, Jiaxing Wang, Zeng-Guang Hou

    Previous rehabilitation robots were usually designed for certain stages, which causes relatively low rehabilitation efficiency. In this study, a multiposture robot was designed for full cycle rehabilitation training for the patients with lower limb disfunctions. Functions of the typical rehabilitation equipments, including the rehabilitation bicycles, the standing beds for the orthostatic hypotension, and the gait trainers, were realized on the robot. Firstly, in order to implement training in the sitting, lying, and standing postures, a slider–pulley–chute mechanism was designed to obtain zero displacement deviation during the backrest adjustment. Then, the biomimetic gait trajectories were designed based on cooperative control of the leg mechanisms, the center of gravity (CoG), and the body weight supporting system; meanwhile, the key points of CoG trajectories for ascending or descending steps were deliberately designed and the suitable CoG trajectories were regenerated using a fifth-order polynomial, based on which continuously implement of ascending or descending steps on the robot was realized. Moreover, sEMG based motion intention recognition paradigms for variable velocity cycling and multi-mode walking were designed and the associated decoders were developed by combined using the support vector machine and stepwise linear regression algorithms and the minimal redundancy maximal relevance criterion. Finally, the autonomous cycling and multi-mode walking training was successfully realized based on recognizing in real time the subjects' intentions for adjustment of cycling velocities or walking modes. The feasibility of the proposed methods was validated based on simulation and real implement of the sEMG based autonomous cycling and multi-mode walking.


  • Open Access

    A Technology Convergence Analysis of Purpose-Built Mobility Shape -Focusing on Case Studies-

    by Kexin Xiang

    최근 몇 년 동안 세계 각국의 인구가 도심으로 밀집됨에 따라 교통 시스템과 교통 패턴이 변화되고 있는것을 우리는 볼 수 있다. 본 연구의 목적은 미래 도심에서 모빌리티 서비스의 주된 이동수단 PBV에 대해 조사하고 형태적인 디자인 변화를 분석하여 영향이 되는 요인을 근거로 디자인 시사점을 탐구하는 것이다. 문헌조사 및 사례연구를 바탕으로 한 24건의 PBV 사례에 대한 분석을 통해 입방체 조형, 플랫폼, L5 자율주행, 전기구동, 태양광 전지, AI, 라스트마일 등 7 개의 디자인 영향 요인을 도출하였다. 차체는 입방체 형태를 유지하고 앞뒷면의 조형이 일치화 되며, 전체적으로 심플한 스타일이 시각적 충격을 줄이는 점을 예측할 수 있다. 지붕은 태양광 전지를 설치하여, 평평한 형태를 유지할 것으로 예상된다. 차체가 유연한 스크린으로 탑승자에게 상호작용하는 서비스를 제공하는 개념도 양산될 전망이다. 화물 운송 및 교통 약자에게 편의를 제공하기 위해 플랫폼은 자동 확장 계단으로 낮은 높이를 유지할 것으로 예상된다. 바퀴 부피가 더욱 감소하고 내부 공간 활용도가 향상될 것으로 예측된다.

  • Open Access

    Comparing Multi-Dimensional fNIRS Features Using Bayesian Optimization-Based Neural Networks for Mild Cognitive Impairment (MCI) Detection

    by Chutian Zhang, Hongjun Yang, Chen-Chen Fan, Sheng Chen, Chenyu Fan, Zeng-Guang Hou, Jingyao Chen, Liang Peng, Kexin Xiang, Yi Wu, et al.

    The diagnosis of mild cognitive impairment (MCI), a prodromal stage of Alzheimer’s disease (AD), is essential for initiating timely treatment to delay the onset of AD. Previous studies have shown the potential of functional near-infrared spectroscopy (fNIRS) for diagnosing MCI. However, preprocessing fNIRS measurements requires extensive experience to identify poor-quality segments. Moreover, few studies have explored how proper multi-dimensional fNIRS features influence the classification results of the disease. Thus, this study outlined a streamlined fNIRS preprocessing method to process fNIRS measurements and compared multi-dimensional fNIRS features with neural networks in order to explore how temporal and spatial factors affect the classification of MCI and cognitive normality. More specifically, this study proposed using Bayesian optimization-based auto hyperparameter tuning neural networks to evaluate 1D channel-wise, 2D spatial, and 3D spatiotemporal features of fNIRS measurements for detecting MCI patients. The highest test accuracies of 70.83%, 76.92%, and 80.77% were achieved for 1D, 2D, and 3D features, respectively. Through extensive comparisons, the 3D time-point oxyhemoglobin feature was proven to be a more promising fNIRS feature for detecting MCI by using an fNIRS dataset of 127 participants. Furthermore, this study presented a potential approach for fNIRS data processing, and the designed models required no manual hyperparameter tuning, which promoted the general utilization of fNIRS modality with neural network-based classification to detect MCI.