PKPriyanka Khaparde

Priyanka Khaparde

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Priyanka Khaparde has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Detection of Small Water Droplets on Flexible Leaf Wetness Sensor Considering the Effect of Spatiotemporal Variation

    by Pooja Yogi, Avinash D. Pawar, Priyanka Khaparde, Pooja Garg, Hemen Kalita, Vinay S. Palaparthy

    Leaf wetness sensors (LWS) are employed widely for plant diseases management. However, a key challenge for LWS during in-situ measurements is detecting small water droplets at various stages of plant growth. Spatiotemporal variation leads to changes in the stem angle, or the leaf canopy may exhibit bending due to environmental factors or physical trauma. A flexible electronic LWS deployed under such a scenario needs to detect the small water droplets. Thus, in this work, rGO-coated LWS is fabricated on a flexible polyimide substrate. Considering the spatiotemporal effect on fabricated LWS, we have examined the efficacy of LWS by varying the water droplets from 0.5 μL (small) to 500 μL (bulk) and changing the angle (from 0 ° to 90 °) and bending the sensor in both inward and outward directions under both laboratory and field conditions. Lab measurements indicate that the sensor response at 0°, 45°, and 90° is approximately 4400 %, 3000 %, and 90 %, respectively, at 1 kHz when only a 0.5 μL water droplet is drop-casted. Furthermore, the sensor response for a 0.5 μL water droplet during inward and outward bending is approximately 5500 % and 7900 %, respectively, when the sensor is bent by 3 cm from its initial position. During the field measurements, it is observed that the fabricated LWS is able to detect 0.5 μL water droplets at angles of 0°, 45°, and 90°. Likewise, fabricated LWS detects small water droplets of 0.5 μL when subjected to inward and outward bending during in-situ measurements.


  • Impact of Electrode Patterns Variation on the Response Characteristic of Leaf Wetness Sensors

    by Kamlesh S. Patle, Neha Sharma, Priyanka Khaparde, Harsh Varshney, Gulafsha Bhatti, Yash Agrawal, Vinay S. Palaparthy

    Prediction of plant diseases is essential to reduce crop loss. Early disease prediction models have been investigated for this purpose, where data on leaf wetness duration (LWD) is one of the key components. Leaf wetness sensors (LWSs) are used to better understand how foliar wetness affects plant disease cycles and epidemic development. LWS can be fabricated on printed circuit boards (PCBs), where interdigitated electrode patterns are widely used. However, it is important to understand the efficacy of these patterns for in-situ measurements. For this purpose, in this work, we have fabricated three different patterns viz. circular, oval, and rectangular on the PCB and tested their efficacy during lab and field measurements. Lab measurements indicate that the circular patterned LWS offers a sensitivity of about 1600% over the dry-to-wet range, which is about 2 and 1.5 times more than oval and rectangular patterns, respectively. Besides this, circular patterned LWS offers the hysteresis of about 2%, whereas the oval and rectangular patterned LWS show about 3% and 7%, respectively. Field measurement results specify that circular patterned LWS and commercial LWS Phytos 31 indicate the same number of LWD events. However, oval and rectangular patterned LWS shows extra false events.


  • Investigating an Impact of Leaf Bending Radius and Angle for Flexible Leaf Wetness Sensor

    by Priyanka Khaparde, Kamlesh S. Patle, Hitesh Borkar, Jitendra Gangwar, Anil K. Roy, Vinay S. Palaparthy

    It is pivotal to monitor and examine the plant disease during in situ measurements to abate the crop loss. For this purpose, leaf wetness sensors (LWS) are widely used. However, for the LWS during in situ measurements, operational exposure is always a concern considering the plant growth at different stages. During the plant growth, the stem angle changes and even the leaf canopy bends either inward or outward due to environmental factors or physical trauma. Thus, LWS placed on the leaf canopy may produce erroneous results. In this letter, we have examined the effect of leaf bending radius (outward or inward) and angle (from 0° to 90°) on the flexible LWS fabricated on the polyamide substrates. LWS comprises of interdigitated electrodes (IDEs) having interelectrode spacing 0.05 cm. Fabricated LWS are 3.5 cm long and 1.5 cm wide in dimension. We have used the two LWS viz. one bare IDEs and another with molybdenum disulfide (MoS 2 ) coated LWS. Lab experiments indicated that sufficient wetness remained on the bare IDEs and MoS 2 -coated IDEs till 40° and 70° of bending angle, respectively. Subsequently, when the LWS are bended outward or inward, bare IDEs and MoS 2 -coated IDEs retain water molecules till 0.7 and 1 cm, respectively, when bended from its initial length (3.5 cm).


  • Environmental and Soil Parameters for Germination of Leaf Spot Disease in the Groundnut Plant Using IoT-Enabled Sensor System

    by Pooja Garg, Priyanka Khaparde, Kamlesh S Patle, Chirag Bhaliya, Ahlad Kumar, Manjunath. V Joshi, Vinay S Palaparthy

    Groundnut cultivation faces persistent challenges from leaf spot disease, which affects crop yield and quality. This study investigates the influence of environmental and soil parameters on the germination of leaf spot disease in groundnut plants where an IoT-enabled sensor system is used to collect the data. A sensor array consisting of soil moisture, soil temperature, leaf wetness (LWS), ambient temperature, and ambient humidity sensors are deployed to monitor critical environmental and soil factors. The aforementioned sensors collectively provide comprehensive insights into the conditions conducive to disease germination. Real-time data collection is achieved by deploying the internet of things (IoT) enabled system, which collects the soil moisture, soil temperature, leaf wetness (LWS), ambient temperature, and ambient humidity information and uploads them on the ThingspeakTM cloud. Field measurements indicates that the temperature (27-32°C), the length of leaf wetness (0–10 hours), high humidity (73% RH or more), soil moisture (4-6%) and soil temperature (19-20°C) all have a significant impact on the germination of leaf spot disease infection. These results are incorporated into the creation of the Multilayer Perceptron (MLP) model, where accuracy of about 85.51% is achieved. The values of precision, recall and F1-score are 87.54%, 84.21% and 85.84%, respectively, achieved for the proposed MLP model. Further, the presence of the disease has been validated by collecting the images during the insitu measurements. The findings enhance our understanding of disease dynamics and offer practical implications for precision agriculture and disease management strategies.


  • Experimental Investigation of Leaf Wetness Sensing Properties of MoS2 Nanoflowers-Based Flexible Leaf Wetness Sensor

    by Priyanka Khaparde, Kamlesh S. Patle, Yash Agrawal, Hitesh Borkar, Jitendra Gangwar, Anil K. Roy, Vinay S. Palaparthy

    To abate crop loss, it is important to explore the plant disease management systems, where leaf wetness sensors (LWS) are widely used. The leaf wetness duration (LWD) extracted from the LWS is related to plant diseases. In this work, we have fabricated the LWS on the polyamide flexible substrate where Molybdenum disulfide (MoS 2 ) is used as the sensing film to explore the leaf wetness sensing mechanism. Further, we have passivated the MoS 2 with the help of acrylic protective lacquer (APL) conformal coating (MoS 2 + APL), which reduce the interaction of the water molecules with the sensor. Lab measurements indicated that fabricated LWS on the flexible substrate with MoS 2 and MoS 2 + APL as the sensing film offers a response of about ≈ 40,000 % and ≈ 250 %, respectively, at 500 Hz excitation frequency when theentiresensing area is filled with thewater molecule. Theresponsetimeof the MoS 2 and APL-coated flexible sensor is about 180 seconds. Fabricated LWS sensors offer hysteresis of about ± 4 % in wetness. Further, we have identified that oxidation of the Sulphur in the MoS 2 playsan important role in theleaf wetness sensingmechanism. Further, we understood that MoS 2 when passivated with APL coating, the oxidation effect is reduced and the sensor response is negligible.