Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qin Rao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research Progress of the Coatings Fabricated onto Titanium and/or Titanium Alloy Surfaces in Biomaterials for Medical Applications for Anticorrosive Applications

    by Qin Rao, Jinshuang Zhang, Yaqing Chen, Yujin Yang, Xu Chen, Donghao Liu, Ruilu Zhu, Ang Li, Yanping Lv, Shunli Zheng

    Titanium (Ti) and its alloys have attracted more interest, as they are widely employed as biomaterials due to their great biocompatibility, excellent strength ratio, and lightweight. However, corrosion occurs slowly due to an electrochemical reaction once the Ti material has been placed in the human body, contributing to infection and failure of implants in medical applications. Thus, the corrosion phenomenon has caused great concern in the biomedical field. It is desirable to make the surface modification to provide better corrosion resistance. The fabrication techniques of the coatings fabricated onto Ti and/or Ti alloy surfaces have been reported, including sol–gel, annealing, plasma spraying, plasma immersion ion implantation, physical vapor deposition, chemical vapor deposition, anodization, and micro-arc oxidation. This review first describes the corrosion types, including localized corrosion (both pitting and crevice corrosion), galvanic corrosion, selective leaching, stress corrosion cracking (SCC), corrosion fatigue (CF), and fretting corrosion. In the second part, the effects of corrosion on the human body were discussed, and the primary cause for clinical failure and allergies has been identified as the excessive release of poisonous and dangerous metal ions (Co, Ni, and Ti) from corroded implants into bodily fluids. The inclusion and exclusion criteria during the selection of literature are described in the third section. In the last section, we emphasized the current research progress of Ti alloy (particularly Ti6Al4V alloy) coatings in biomaterials for medical applications involving dental, orthopedic, and cardiovascular implants for anticorrosive applications. However, there are also several problems to explore and address in future studies, such as the release of excessive metal ions, etc. This review will draw attention to both researchers and clinicians, which could help to increase the coatings fabricated onto Ti and/or Ti alloy surfaces for anticorrosive applications in biomaterials for medical applications.


  • Open Access

    A Titanium-Based Superhydrophobic Coating with Enhanced Antibacterial, Anticoagulant, and Anticorrosive Properties for Dental Applications

    by Qin Rao, Ling Weng, Jinshuang Zhang, Yaqing Chen, Yujin Yang, Donghao Liu, Yurong Duan, Ying Cao, Jialong Chen, Xiangyang Li, et al.

    Titanium and its alloys have been widely employed as dental implant materials. However, polymicrobial infection is still one of the most common reasons for implant failure, which has already become a worldwide problem and poses a threat to human health. In this study, a titanium-based (Ti-based) superhydrophobic coating was effectively created by anodization followed by hydrophobic modification of 1H,1H,2H,2H-perfluorodecyltriethoxysilane (FAS), which shows a high water contact angle (WCA) of 159.9 ± 5.8° and a low water sliding angle (WSA) of 2.7 ± 2.2°. The thickness of the anodized samples is from 500 nm to 4 µm as the anodizing voltage increases. The Ti-based superhydrophobic coating demonstrated the existence of Ti, O, C, F, and Si elements, and the corresponding phase compositions are Ti and anatase. The results showed that the Ti-based superhydrophobic coating has good biocompatibility to co-culture with L929 cells for 1, 3, and 5 days. It was also proven that the as-prepared Ti-based superhydrophobic coating has enhanced antibacterial abilities against Staphylococcus aureus (S. aureus) and Porphyromonas gingivalis (P. gingivalis, P.g) after 4, 12, and 24 h. Moreover, the Ti-based superhydrophobic coating can significantly reduce platelet adhesion and activation. In addition, the Ti-based superhydrophobic coating also exhibits a considerable positive shift in the corrosion potential (Ecorr) and a decline of one order of magnitude in the corrosion current density (Jcorr), showing good anticorrosive properties. It was also found that the capsule around the Ti-based superhydrophobic coating was thinner than that of bare Ti after implantation for 7, 15, and 28 days, indicating its good biosafety. Therefore, the as-prepared Ti-based superhydrophobic coating can be a suitable candidate for Ti-based implants in dental applications.


  • Open Access

    Research Progress in Superhydrophobic Titanium-Based Implants for Antibacterial Applications

    by Qin Rao, Ling Weng, Jinshuang Zhang, Donghao Liu, Wenjuan Zhang, Siyuan Chen, Jialong Chen, Xiangyang Li, Hua Qiu, Ying Cao, et al.

    Titanium and its alloys have been extensively used as implant materials in clinic settings. However, implant-associated bacterial infection or inflammation remains a primary cause of implantation failure, which threatens human health, and has already become a global issue. Recently, a superhydrophobic surface endowed with a water contact angle higher than 150° has attracted widespread attention in antibacterial applications for their self-cleaning and low-adhesion properties, which has emerged as an important path in preventing biofilm formation. This review first describes the basic theories of wettability. In the second section, we explain biofilm formation, which is a primary pathogenic occurrence in the development of infection in implants. In the last and most important section, we summarize the progress of superhydrophobic titanium-based implants and recent antibacterial applications. This review will attract great interest from both research scientists and clinicians, which will help to rapidly expand superhydrophobic titanium-based implants for antibacterial applications.