Noriaki Hamatani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Noriaki Hamatani has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Kazumasa Minami
Division of Health Science, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN
2 shared publicationsMasaaki Takashina
Department of Medical Physics Osaka Heavy Ion Therapy Center Osaka Japan
2 shared publicationsTatsuaki Kanai
Division of Health Science, The University of Osaka Graduate School of Medicine Faculty of Medicine, 1-1 Yamadaoka, Suita, Osaka Prefecture, 5650871, JAPAN
2 shared publicationsToshiro Tsubouchi
Department of Radiation Oncology Piedmont Mountainside Hospital Jasper Georgia USA
2 shared publicationsAkira Komada
Department of Medical Physics Osaka Heavy Ion Therapy Center Osaka Japan
1 shared publication- Masaaki Takashina
Department of Medical Physics, Osaka Heavy Ion Therapy Center, Otemae, Chuo-ku, Osaka, Osaka, 5400008, JAPAN
1 shared publication
Latest Publications
- Open Access
- 5 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (10) , e70844
A practical framework for routine verification of Spot Position Monitor coordinate consistency in scanned carbon‐ion radiotherapy
Background: Log file–based patient specific quality assurance (PSQA) in scanned particle therapy relies on the consistency of spot position information recorded by the spot position monitor (SPM), but practical methods for routine independent verification of these coordinates remain limited. Purpose: This study describes a practical framework for routine verification of SPM coordinate consistency using independent scintillator‐based measurements in raster‐scanning carbon‐ion radiotherapy. Methods: Reference spot positions were measured at the isocenter plane using a scintillator‐based detector. Corresponding SPM‐recorded spot coordinates were extracted from delivery log files. The two coordinate sets were aligned using a similarity transformation accounting for translation, rotation, and isotropic scaling. Post‐transformation root‐mean‐square (RMS) residuals were used as a practical consistency metric reflecting the agreement between SPM‐reported and independently measured spot positions under routine QA conditions. Results: After similarity transformation, the median RMS residual across all investigated accelerator energies and irradiation ports was 1.45 mm, with an interquartile range of 1.36–1.63 mm. No statistically significant difference was detected across accelerator energies, whereas a significant difference was observed among irradiation ports. Conclusions: The proposed framework provides a practical approach for routine verification of SPM coordinate consistency and for establishing facility‐specific baselines through longitudinal monitoring. The RMS residual should not be interpreted as the intrinsic positional error of the SPM alone, but to provide a framework for establishing a facility‐specific baseline for monitoring the agreement between SPM‐reported and independently measured spot coordinates under routine QA conditions.
- 5 October 2026
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (10) , e70844
Open AccessA practical framework for routine verification of Spot Position Monitor coordinate consistency in scanned carbon‐ion radiotherapy
Background: Log file–based patient specific quality assurance (PSQA) in scanned particle therapy relies on the consistency of spot position information recorded by the spot position monitor (SPM), but practical methods for routine independent verification of these coordinates remain limited. Purpose: This study describes a practical framework for routine verification of SPM coordinate consistency using independent scintillator‐based measurements in raster‐scanning carbon‐ion radiotherapy. Methods: Reference spot positions were measured at the isocenter plane using a scintillator‐based detector. Corresponding SPM‐recorded spot coordinates were extracted from delivery log files. The two coordinate sets were aligned using a similarity transformation accounting for translation, rotation, and isotropic scaling. Post‐transformation root‐mean‐square (RMS) residuals were used as a practical consistency metric reflecting the agreement between SPM‐reported and independently measured spot positions under routine QA conditions. Results: After similarity transformation, the median RMS residual across all investigated accelerator energies and irradiation ports was 1.45 mm, with an interquartile range of 1.36–1.63 mm. No statistically significant difference was detected across accelerator energies, whereas a significant difference was observed among irradiation ports. Conclusions: The proposed framework provides a practical approach for routine verification of SPM coordinate consistency and for establishing facility‐specific baselines through longitudinal monitoring. The RMS residual should not be interpreted as the intrinsic positional error of the SPM alone, but to provide a framework for establishing a facility‐specific baseline for monitoring the agreement between SPM‐reported and independently measured spot coordinates under routine QA conditions.
- Open Access
- 22 January 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015052
Quantifying biological effects of spatially heterogeneous carbon ion dose distributions using EUD
This study aimed to experimentally investigate the cell survival responses of tumor and normal cell lines to spatially heterogeneous carbon ion dose distributions with varying peak-to-valley dose ratios (PVDRs) and linear energy transfer (LET) conditions, and to assess the utility of equivalent uniform dose (EUD) as a quantitative metric for analyzing these responses. HSGc-C5 (tumor) and Nuli-1 (normal tissue) cell lines were irradiated using carbon ion beams with different spatial dose patterns (Grid, Frame, Half) and two PVDR levels under low LET conditions (~10 keV μm −1 ). Additionally, high LET (~50 keV μm −1 ) Spread Out Bragg Peak (SOBP) Grid patterns were used for the HSGc-C5 cells. Clonogenic survival assays were performed to evaluate biological response. Survival data were analyzed both as a function of delivered physical dose and EUD, calculated using an LQ model–based formulation. Tumor cells exhibited enhanced cytotoxic effects under high LET and high PVDR conditions (the dose required to reach SF = 0.1 was approximately 40% lower at PVDR = 4.0 and 10% lower at PVDR = 1.64 compared with the simulation results), whereas normal cells showed a slight sparing effect under low LET irradiation. Even at the same total dose and PVDR, different spatial dose patterns produced measurable differences in survival, underscoring the impact of spatial heterogeneity. EUD-based analysis further enabled quantitative comparison between heterogeneous and uniform dose distributions. These findings indicate that spatial dose heterogeneity and LET can be leveraged to enhance tumor control while reducing normal tissue damage in carbon ion therapy. The EUD approach may offer a practical tool for treatment plan evaluation in spatially modulated particle therapy.
- 22 January 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (1) , 015052
Open AccessQuantifying biological effects of spatially heterogeneous carbon ion dose distributions using EUD
This study aimed to experimentally investigate the cell survival responses of tumor and normal cell lines to spatially heterogeneous carbon ion dose distributions with varying peak-to-valley dose ratios (PVDRs) and linear energy transfer (LET) conditions, and to assess the utility of equivalent uniform dose (EUD) as a quantitative metric for analyzing these responses. HSGc-C5 (tumor) and Nuli-1 (normal tissue) cell lines were irradiated using carbon ion beams with different spatial dose patterns (Grid, Frame, Half) and two PVDR levels under low LET conditions (~10 keV μm −1 ). Additionally, high LET (~50 keV μm −1 ) Spread Out Bragg Peak (SOBP) Grid patterns were used for the HSGc-C5 cells. Clonogenic survival assays were performed to evaluate biological response. Survival data were analyzed both as a function of delivered physical dose and EUD, calculated using an LQ model–based formulation. Tumor cells exhibited enhanced cytotoxic effects under high LET and high PVDR conditions (the dose required to reach SF = 0.1 was approximately 40% lower at PVDR = 4.0 and 10% lower at PVDR = 1.64 compared with the simulation results), whereas normal cells showed a slight sparing effect under low LET irradiation. Even at the same total dose and PVDR, different spatial dose patterns produced measurable differences in survival, underscoring the impact of spatial heterogeneity. EUD-based analysis further enabled quantitative comparison between heterogeneous and uniform dose distributions. These findings indicate that spatial dose heterogeneity and LET can be leveraged to enhance tumor control while reducing normal tissue damage in carbon ion therapy. The EUD approach may offer a practical tool for treatment plan evaluation in spatially modulated particle therapy.
- Open Access
- 11 February 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102537
Treatment planning of carbon ion radiotherapy for prostate cancer based on cellular experiments with PC3 human prostate cancer cells
- 11 February 2023
- Published by Elsevier in Physica Medica
- Vol. 107, 102537
Open AccessTreatment planning of carbon ion radiotherapy for prostate cancer based on cellular experiments with PC3 human prostate cancer cells