Yen-Hsiang Huang
Yen-Hsiang Huang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Sunny C. Jiang
Department of Civil and Environmental Engineering, University of California, Irvine, CA 92697, USA
7 shared publications - Chengwen Wang
School of Environment, Tsinghua University, Beijing 100084, China
2 shared publications Peter J. Santiago
Department of Materials Science and Engineering, University of California, Irvine, Irvine, California 92697, United States
2 shared publications- Regina Ragan
Univ. of California, Irvine (United States)
2 shared publications Zi-Lu Ou-Yang
School of Environment, Tsinghua University, Beijing, China
2 shared publications- Allon Israel Hochbaum
University of California Irvine
1 shared publication
Latest Publications
- Open Access
- 8 February 2026
- Published by American Geophysical Union (AGU) in GeoHealth
- Vol. 10 (2)
Quantifying Vibrio Infection Risks From Beach Recreation Along U.S. Eastern Seaboard in Year 2100
Marine vibrios, a group of marine bacteria that are opportunist human pathogens, proliferates faster in coastal environments at warmer temperature. Recently, there have been significant concerns of human infection risks during marine beach recreations due to the elevation of seawater temperature in the United States Eastern Seaboard. This study carried out a quantitative microbial risk assessment (QMRA) to estimate health risks associated with V . vulnificus and V . parahaemolyticus infections from water ingestion during recreational activities under varying climate scenarios that predict sea surface temperatures (SSTs) in the next 75 years. Monte Carlo simulations that incorporate Vibrio concentrations at specific SSTs, ingestion dose during recreational activities, and dose‐response relationships were applied to predict the probability of infection under varying exposure scenarios. The risk of Vibrio infections along the U.S. Eastern Seaboard was first estimate for the year 2020 based on measured SSTs. The same approach was applied to predict the risk in the year 2100 based on projected SSTs using two IPCC Representative Concentration Pathways (RCP) scenarios: RCP 2.6 and RCP 8.5. The results indicate that the median risks of V . vulnificus and V . parahaemolyticus from recreational activities along the Eastern Seaboard increase significantly from 2020 to 2100, with rises of up to 1,000‐fold under RCP 8.5 and up to 100‐fold under RCP 2.6. Furthermore, the estimated risks represent a conservative lower‐bound of vibrio‐related health impacts because wound infection from water contact was not included. This study highlights the growing public health concern and the need for adaptive management strategies.
- 8 February 2026
- Published by American Geophysical Union (AGU) in GeoHealth
- Vol. 10 (2)
Open AccessQuantifying Vibrio Infection Risks From Beach Recreation Along U.S. Eastern Seaboard in Year 2100
Marine vibrios, a group of marine bacteria that are opportunist human pathogens, proliferates faster in coastal environments at warmer temperature. Recently, there have been significant concerns of human infection risks during marine beach recreations due to the elevation of seawater temperature in the United States Eastern Seaboard. This study carried out a quantitative microbial risk assessment (QMRA) to estimate health risks associated with V . vulnificus and V . parahaemolyticus infections from water ingestion during recreational activities under varying climate scenarios that predict sea surface temperatures (SSTs) in the next 75 years. Monte Carlo simulations that incorporate Vibrio concentrations at specific SSTs, ingestion dose during recreational activities, and dose‐response relationships were applied to predict the probability of infection under varying exposure scenarios. The risk of Vibrio infections along the U.S. Eastern Seaboard was first estimate for the year 2020 based on measured SSTs. The same approach was applied to predict the risk in the year 2100 based on projected SSTs using two IPCC Representative Concentration Pathways (RCP) scenarios: RCP 2.6 and RCP 8.5. The results indicate that the median risks of V . vulnificus and V . parahaemolyticus from recreational activities along the Eastern Seaboard increase significantly from 2020 to 2100, with rises of up to 1,000‐fold under RCP 8.5 and up to 100‐fold under RCP 2.6. Furthermore, the estimated risks represent a conservative lower‐bound of vibrio‐related health impacts because wound infection from water contact was not included. This study highlights the growing public health concern and the need for adaptive management strategies.
- Open Access
- 8 May 2025
- Published by American Chemical Society (ACS) in ACS ES&T Engineering
- Vol. 5 (8) , 1943-1952
Combining Phenotypic and Genotypic Methods for the Rapid Detection of Antibiotic-Resistant Bacteria in Wastewater Using a Microfluidic Centrifugal Disc
Antimicrobial resistance (AMR) has emerged as a critical global health threat, leading to untreatable infectious diseases and significantly increasing human morbidity and mortality. Rapid, portable, and user-friendly detection of antibiotic-resistant bacteria (ARB) in the environment plays a key role in controlling the spread of diseases and combating the emergence of AMR. In this study, we report a portable microfluidic centrifugal disc (CD) assay incorporating both phenotypic and genotypic methods for ARB detection. This assay significantly reduces the time required for bacterial culturing from days to hours while maintaining the reliability of phenotypic methods. Moreover, the CD assay eliminates the need for a centralized laboratory and well-trained personnel. The on-CD ARB detection can be completed in less than 3 h after sample and reagent loading. The results demonstrated that the on-CD assay provided performance comparable to that of the benchtop ARB detection assay. Analysis of variance (ANOVA) comparing the benchtop and on-CD assays yielded a p-value of 0.08 for the bacterial growth rate and a p-value of 0.73 for the cell recovery rate after the sample purification, confirming no significant differences between the two approaches. The ARB detection assay was able to identify ampicillin-resistant spiked in wastewater at concentrations as low as 10 CFU/μL. Additionally, the CD assay detected indigenous ampicillin-resistant in wastewater, demonstrating the potential of this platform for environmental applications.
- 8 May 2025
- Published by American Chemical Society (ACS) in ACS ES&T Engineering
- Vol. 5 (8) , 1943-1952
Open AccessCombining Phenotypic and Genotypic Methods for the Rapid Detection of Antibiotic-Resistant Bacteria in Wastewater Using a Microfluidic Centrifugal Disc
Antimicrobial resistance (AMR) has emerged as a critical global health threat, leading to untreatable infectious diseases and significantly increasing human morbidity and mortality. Rapid, portable, and user-friendly detection of antibiotic-resistant bacteria (ARB) in the environment plays a key role in controlling the spread of diseases and combating the emergence of AMR. In this study, we report a portable microfluidic centrifugal disc (CD) assay incorporating both phenotypic and genotypic methods for ARB detection. This assay significantly reduces the time required for bacterial culturing from days to hours while maintaining the reliability of phenotypic methods. Moreover, the CD assay eliminates the need for a centralized laboratory and well-trained personnel. The on-CD ARB detection can be completed in less than 3 h after sample and reagent loading. The results demonstrated that the on-CD assay provided performance comparable to that of the benchtop ARB detection assay. Analysis of variance (ANOVA) comparing the benchtop and on-CD assays yielded a p-value of 0.08 for the bacterial growth rate and a p-value of 0.73 for the cell recovery rate after the sample purification, confirming no significant differences between the two approaches. The ARB detection assay was able to identify ampicillin-resistant spiked in wastewater at concentrations as low as 10 CFU/μL. Additionally, the CD assay detected indigenous ampicillin-resistant in wastewater, demonstrating the potential of this platform for environmental applications.
- Open Access
- 2 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (6) , 3088-3097
Quantification of Viruses in Wastewater on a Centrifugal Microfluidic Disc
Rapid and onsite detection of pathogens in water is a critical first step in preventing the spread of infectious diseases from the environment to humans. However, current microbial monitoring practices are tedious, expensive, and slow. These limitations significantly impede our ability to promptly identify potential risks to public health, leading to delays in implementing the necessary interventions. In this study, we report the development of a portable centrifugal microfluidic disc (CD) that integrates sample concentration, purification, and a droplet digital reverse transcription LAMP (ddRT-LAMP) assay as a lab-on-a-chip system for rapid virus detection in the environment. Coupled with the pseudo- and nonpseudo forces generated during the CD rotation or oscillation, the assay steps for sample purification, concentration, and quantification were completed in less than 1.5 h. The results showed that the on-CD sample preparation procedures are comparable to the traditional in-tube sample preparation assay. Furthermore, the indigenous pepper mild mottle virus (PMMoV) in raw sewage at concentrations ranging from 6.0 × 104 to 2.1 × 107 copies/ml was successfully quantified using the complete on-CD assay, which includes on-CD sample preparation procedures and on-CD ddRT-LAMP. The concentrations of PMMoV detected by the CD assay matched well with those detected by the state-of-the-art virus nucleic acid extraction and ddRT-PCR assay for wastewater and wastewater-spiked environmental water samples, demonstrating the potential of this CD platform for environmental applications.
- 2 February 2025
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 59 (6) , 3088-3097
Open AccessQuantification of Viruses in Wastewater on a Centrifugal Microfluidic Disc
Rapid and onsite detection of pathogens in water is a critical first step in preventing the spread of infectious diseases from the environment to humans. However, current microbial monitoring practices are tedious, expensive, and slow. These limitations significantly impede our ability to promptly identify potential risks to public health, leading to delays in implementing the necessary interventions. In this study, we report the development of a portable centrifugal microfluidic disc (CD) that integrates sample concentration, purification, and a droplet digital reverse transcription LAMP (ddRT-LAMP) assay as a lab-on-a-chip system for rapid virus detection in the environment. Coupled with the pseudo- and nonpseudo forces generated during the CD rotation or oscillation, the assay steps for sample purification, concentration, and quantification were completed in less than 1.5 h. The results showed that the on-CD sample preparation procedures are comparable to the traditional in-tube sample preparation assay. Furthermore, the indigenous pepper mild mottle virus (PMMoV) in raw sewage at concentrations ranging from 6.0 × 104 to 2.1 × 107 copies/ml was successfully quantified using the complete on-CD assay, which includes on-CD sample preparation procedures and on-CD ddRT-LAMP. The concentrations of PMMoV detected by the CD assay matched well with those detected by the state-of-the-art virus nucleic acid extraction and ddRT-PCR assay for wastewater and wastewater-spiked environmental water samples, demonstrating the potential of this CD platform for environmental applications.
- Open Access
- 19 March 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (12) , 4880-4891
Sensing Antibiotics in Wastewater Using Surface-Enhanced Raman Scattering
Rapid and cost-effective detection of antibiotics in wastewater and through wastewater treatment processes is an important first step in developing effective strategies for their removal. Surface-enhanced Raman scattering (SERS) has the potential for label-free, real-time sensing of antibiotic contamination in the environment. This study reports the testing of two gold nanostructures as SERS substrates for the label-free detection of quinoline, a small-molecular-weight antibiotic that is commonly found in wastewater. The results showed that the self-assembled SERS substrate was able to quantify quinoline spiked in wastewater with a lower limit of detection (LoD) of 5.01 ppb. The SERStrate (commercially available SERS substrate with gold nanopillars) had a similar sensitivity for quinoline quantification in pure water (LoD of 1.15 ppb) but did not perform well for quinoline quantification in wastewater (LoD of 97.5 ppm) due to interferences from non-target molecules in the wastewater. Models constructed based on machine learning algorithms could improve the separation and identification of quinoline Raman spectra from those of interference molecules to some degree, but the selectivity of SERS intensification was more critical to achieve the identification and quantification of the target analyte. The results of this study are a proof-of-concept for SERS applications in label-free sensing of environmental contaminants. Further research is warranted to transform the concept into a practical technology for environmental monitoring.
- 19 March 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (12) , 4880-4891
Open AccessSensing Antibiotics in Wastewater Using Surface-Enhanced Raman Scattering
Rapid and cost-effective detection of antibiotics in wastewater and through wastewater treatment processes is an important first step in developing effective strategies for their removal. Surface-enhanced Raman scattering (SERS) has the potential for label-free, real-time sensing of antibiotic contamination in the environment. This study reports the testing of two gold nanostructures as SERS substrates for the label-free detection of quinoline, a small-molecular-weight antibiotic that is commonly found in wastewater. The results showed that the self-assembled SERS substrate was able to quantify quinoline spiked in wastewater with a lower limit of detection (LoD) of 5.01 ppb. The SERStrate (commercially available SERS substrate with gold nanopillars) had a similar sensitivity for quinoline quantification in pure water (LoD of 1.15 ppb) but did not perform well for quinoline quantification in wastewater (LoD of 97.5 ppm) due to interferences from non-target molecules in the wastewater. Models constructed based on machine learning algorithms could improve the separation and identification of quinoline Raman spectra from those of interference molecules to some degree, but the selectivity of SERS intensification was more critical to achieve the identification and quantification of the target analyte. The results of this study are a proof-of-concept for SERS applications in label-free sensing of environmental contaminants. Further research is warranted to transform the concept into a practical technology for environmental monitoring.
- Open Access
- 6 February 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (7)
Decoding the metabolic response of Escherichia coli for sensing trace heavy metals in water
Heavy metal contamination due to industrial and agricultural waste represents a growing threat to water supplies. Frequent and widespread monitoring for toxic metals in drinking and agricultural water sources is necessary to prevent their accumulation in humans, plants, and animals, which results in disease and environmental damage. Here, the metabolic stress response of bacteria is used to report the presence of heavy metal ions in water by transducing ions into chemical signals that can be fingerprinted using machine learning analysis of vibrational spectra. Surface-enhanced Raman scattering surfaces amplify chemical signals from bacterial lysate and rapidly generate large, reproducible datasets needed for machine learning algorithms to decode the complex spectral data. Classification and regression algorithms achieve limits of detection of 0.5 pM for As 3+ and 6.8 pM for Cr 6+ , 100,000 times lower than the World Health Organization recommended limits, and accurately quantify concentrations of analytes across six orders of magnitude, enabling early warning of rising contaminant levels. Trained algorithms are generalizable across water samples with different impurities; water quality of tap water and wastewater was evaluated with 92% accuracy.
- 6 February 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (7)
Open AccessDecoding the metabolic response of Escherichia coli for sensing trace heavy metals in water
Heavy metal contamination due to industrial and agricultural waste represents a growing threat to water supplies. Frequent and widespread monitoring for toxic metals in drinking and agricultural water sources is necessary to prevent their accumulation in humans, plants, and animals, which results in disease and environmental damage. Here, the metabolic stress response of bacteria is used to report the presence of heavy metal ions in water by transducing ions into chemical signals that can be fingerprinted using machine learning analysis of vibrational spectra. Surface-enhanced Raman scattering surfaces amplify chemical signals from bacterial lysate and rapidly generate large, reproducible datasets needed for machine learning algorithms to decode the complex spectral data. Classification and regression algorithms achieve limits of detection of 0.5 pM for As 3+ and 6.8 pM for Cr 6+ , 100,000 times lower than the World Health Organization recommended limits, and accurately quantify concentrations of analytes across six orders of magnitude, enabling early warning of rising contaminant levels. Trained algorithms are generalizable across water samples with different impurities; water quality of tap water and wastewater was evaluated with 92% accuracy.
- 1 March 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 762, 143056
Quantifying the risk of indoor drainage system in multi-unit apartment building as a transmission route of SARS-CoV-2
- 1 March 2021
- Published by Elsevier in Science of The Total Environment
- Vol. 762, 143056
Quantifying the risk of indoor drainage system in multi-unit apartment building as a transmission route of SARS-CoV-2
- Open Access
Quantifying the Risk of Indoor Drainage System in Multi-unit Apartment Building as a Transmission Route of SARS-CoV-2
The COVID-19 pandemic has had a profound impact on human society. The isolation of SARS-CoV-2 from patients’ feces on human cell line raised concerns of possible transmission through human feces including exposure to aerosols generated by toilet flushing and through the indoor drainage system. Currently, routes of transmission, other than the close contact droplet transmission, are still not well understood. A quantitative microbial risk assessment was conducted to estimate the health risks associated with two aerosol exposure scenarios: 1) toilet flushing, and 2) faulty connection of a floor drain with the building’s main sewer pipe. SARS-CoV-2 data were collected from the emerging literature. The infectivity of the virus in feces was estimated based on a range of assumption between viral genome equivalence and infectious unit. The human exposure dose was calculated using Monte Carlo simulation of viral concentrations in aerosols under each scenario and human breathing rates. The probability of COVID-19 illness was generated using the dose-response model for SARS-CoV-1, a close relative of SARS-CoV-2, that was responsible for the SARS outbreak in 2003. The results indicate the median risks of developing COVID-19 for a single day exposure is 1.11 x 10 -10 and 3.52 x 10 -11 for toilet flushing and faulty drain scenario, respectively. The worst case scenario predicted the high end of COVID-19 risk for the toilet flushing scenario was 5.78 x 10 -4 (at 95 th percentile). The infectious viral loads in human feces are the most sensitive input parameter and contribute significantly to model uncertainty.
Open AccessQuantifying the Risk of Indoor Drainage System in Multi-unit Apartment Building as a Transmission Route of SARS-CoV-2
The COVID-19 pandemic has had a profound impact on human society. The isolation of SARS-CoV-2 from patients’ feces on human cell line raised concerns of possible transmission through human feces including exposure to aerosols generated by toilet flushing and through the indoor drainage system. Currently, routes of transmission, other than the close contact droplet transmission, are still not well understood. A quantitative microbial risk assessment was conducted to estimate the health risks associated with two aerosol exposure scenarios: 1) toilet flushing, and 2) faulty connection of a floor drain with the building’s main sewer pipe. SARS-CoV-2 data were collected from the emerging literature. The infectivity of the virus in feces was estimated based on a range of assumption between viral genome equivalence and infectious unit. The human exposure dose was calculated using Monte Carlo simulation of viral concentrations in aerosols under each scenario and human breathing rates. The probability of COVID-19 illness was generated using the dose-response model for SARS-CoV-1, a close relative of SARS-CoV-2, that was responsible for the SARS outbreak in 2003. The results indicate the median risks of developing COVID-19 for a single day exposure is 1.11 x 10 -10 and 3.52 x 10 -11 for toilet flushing and faulty drain scenario, respectively. The worst case scenario predicted the high end of COVID-19 risk for the toilet flushing scenario was 5.78 x 10 -4 (at 95 th percentile). The infectious viral loads in human feces are the most sensitive input parameter and contribute significantly to model uncertainty.