Jingjing Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jingjing Zhao has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
Lin Du
Department of Neurological Surgery, The Ohio State University, Columbus, USA
4 shared publicationsAidan Van Vleck
Department of Structural Biology, Stanford University School of Medicine, Stanford, California 94305, United States
3 shared publicationsAdam de la Zerda
Department of Structural Biology, Stanford University School of Medicine, Stanford, California 94305, United States
2 shared publications- Adam de la Zerda
Department of Structural Biology, Stanford University School of Medicine, Stanford University, Stanford, USA
2 shared publications Kaitlyn Liang
Department of Radiology, Stanford University School of Medicine, Stanford, California 94305, United States
2 shared publications- Lingqi Jiang
Department of Precision Instrument, Tsinghua University, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by Taylor & Francis in Virulence
- Vol. 17 (1) , 2678043
Grass carp catalase inhibits GCRV replication through ROS scavenging-mediated immune suppression and autophagy
1. Reactive oxygen species (ROS) are highly reactive molecules derived from oxygen that can trigger a variety of chemical processes within biological systems. This group includes species such as su...
- 2 June 2026
- Published by Taylor & Francis in Virulence
- Vol. 17 (1) , 2678043
Open AccessGrass carp catalase inhibits GCRV replication through ROS scavenging-mediated immune suppression and autophagy
1. Reactive oxygen species (ROS) are highly reactive molecules derived from oxygen that can trigger a variety of chemical processes within biological systems. This group includes species such as su...
- Open Access
- 16 March 2026
- Published by Springer Nature in PhotoniX
- Vol. 7 (1) , 18
Needle beam two-photon microscopy for simultaneous multiplane neural and vascular imaging in awake mice
Comprehensive understanding of brain functions necessitates high-speed imaging of neuronal and vascular dynamics across extensive volumes. Functional neuroimaging investigations with two-photon microscopy are commonly hindered by its limited depth of field which restricts imaging rates across multiple planes. We introduce needle-shaped beam two-photon microscopy (NB-2PM), a versatile platform for high-throughput neurovascular imaging at sub-cellular resolution across multiple depths. It employs customized diffractive optical elements to generate single- or multi-plane needle beams with up to 10 times elongated depth of field relative to Rayleigh lengths and engineered axial energy distribution to effectively offset light attenuation with depth. The proposed method was applied to snapshot volumetric vascular imaging and multi-plane neurovascular dynamic recordings of resting state and stimulus-evoked activity in mice. NB-2PM can seamlessly be integrated into existing microscopy systems, thus providing a scalable platform for gaining comprehensive insights into the functional architecture of murine brain.
- 16 March 2026
- Published by Springer Nature in PhotoniX
- Vol. 7 (1) , 18
Open AccessNeedle beam two-photon microscopy for simultaneous multiplane neural and vascular imaging in awake mice
Comprehensive understanding of brain functions necessitates high-speed imaging of neuronal and vascular dynamics across extensive volumes. Functional neuroimaging investigations with two-photon microscopy are commonly hindered by its limited depth of field which restricts imaging rates across multiple planes. We introduce needle-shaped beam two-photon microscopy (NB-2PM), a versatile platform for high-throughput neurovascular imaging at sub-cellular resolution across multiple depths. It employs customized diffractive optical elements to generate single- or multi-plane needle beams with up to 10 times elongated depth of field relative to Rayleigh lengths and engineered axial energy distribution to effectively offset light attenuation with depth. The proposed method was applied to snapshot volumetric vascular imaging and multi-plane neurovascular dynamic recordings of resting state and stimulus-evoked activity in mice. NB-2PM can seamlessly be integrated into existing microscopy systems, thus providing a scalable platform for gaining comprehensive insights into the functional architecture of murine brain.
- Open Access
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (01) , 016003-13
Wearable optical coherence tomography angiography probe with extended depth of field
The advancement of biomedical imaging technology has significantly enhanced our understanding of complex physiological processes and the diagnosis of various health issues.1 – 3 Understanding the cerebral hemodynamics in rodents is a crucial question of interest in the fields of neuroscience, physiology, psychology, and imaging.4,5 The vast majority of traditional imaging techniques require the subject animals to remain still or be anesthetized to ensure image quality and stability, classic optical imaging setups for mouse brains typically involve fixing the mouse’s head beneath the lens, and throughout the imaging process, gas anesthetics are delivered to the mouse through a tube and a mask. These setups are widely used in two-photon microscopy,6 photoacoustic imaging,7 and optical coherence tomography (OCT).8 However, under anesthesia, multiple physiological indicators can be affected, leading to research results that may not fully represent the true physiological state.9 Therefore, there is a growing awareness of the necessity to image the brain under fully awake conditions.
- 1 January 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (01) , 016003-13
Open AccessWearable optical coherence tomography angiography probe with extended depth of field
The advancement of biomedical imaging technology has significantly enhanced our understanding of complex physiological processes and the diagnosis of various health issues.1 – 3 Understanding the cerebral hemodynamics in rodents is a crucial question of interest in the fields of neuroscience, physiology, psychology, and imaging.4,5 The vast majority of traditional imaging techniques require the subject animals to remain still or be anesthetized to ensure image quality and stability, classic optical imaging setups for mouse brains typically involve fixing the mouse’s head beneath the lens, and throughout the imaging process, gas anesthetics are delivered to the mouse through a tube and a mask. These setups are widely used in two-photon microscopy,6 photoacoustic imaging,7 and optical coherence tomography (OCT).8 However, under anesthesia, multiple physiological indicators can be affected, leading to research results that may not fully represent the true physiological state.9 Therefore, there is a growing awareness of the necessity to image the brain under fully awake conditions.
- 6 May 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3481-3485
Extending Depth-of-Field of Arbitrary Diffractive Optics with Needle-Shaped Beam Modulation
- 6 May 2024
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 11 (9) , 3481-3485
Extending Depth-of-Field of Arbitrary Diffractive Optics with Needle-Shaped Beam Modulation
- 18 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (4) , 2102-2111
Balancing the Components of Biomass and the Reactivity of Pyrolysis Gas: Biomass-Assisted Recycling of Spent LiCoO2 Batteries
Waste biomass is one of the promising feedstocks to supply syngas that can be used as fuels, chemicals, reductants, etc. However, the relationship between the component of biomass and the constituent of pyrolysis gas remains unclear. Here, we study the pyrolysis behaviors of various biomasses and reveal the relationship between the biomass components and gas compositions. Further, different pyrolysis gases are applied for the reduction of spent lithium cobalt oxide (LiCoO2) below 500 °C. The pyrolysis gas with a higher concentration of CO has a higher reductivity to convert LiCoO2 to CoO and Li2CO3 with a conversion rate close to 100% in 1 h at 500 °C. The biomass rich in cellulose and with a lower content of lignin tends to produce pyrolysis gas with a high concentration of CO, which comes from the deliberate breakdown of carboxyl, carbonyl, ether, and ester linkages. Moreover, LiCoO2 exerts catalytic functions over the deoxygenation and enhancement of oxygenates and single-ring aromatics. Overall, this paper offers a tailored approach to regulating biomass pyrolysis gases, enabling highly efficient battery recycling and syngas production.
- 18 January 2024
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 58 (4) , 2102-2111
Balancing the Components of Biomass and the Reactivity of Pyrolysis Gas: Biomass-Assisted Recycling of Spent LiCoO2 Batteries
Waste biomass is one of the promising feedstocks to supply syngas that can be used as fuels, chemicals, reductants, etc. However, the relationship between the component of biomass and the constituent of pyrolysis gas remains unclear. Here, we study the pyrolysis behaviors of various biomasses and reveal the relationship between the biomass components and gas compositions. Further, different pyrolysis gases are applied for the reduction of spent lithium cobalt oxide (LiCoO2) below 500 °C. The pyrolysis gas with a higher concentration of CO has a higher reductivity to convert LiCoO2 to CoO and Li2CO3 with a conversion rate close to 100% in 1 h at 500 °C. The biomass rich in cellulose and with a lower content of lignin tends to produce pyrolysis gas with a high concentration of CO, which comes from the deliberate breakdown of carboxyl, carbonyl, ether, and ester linkages. Moreover, LiCoO2 exerts catalytic functions over the deoxygenation and enhancement of oxygenates and single-ring aromatics. Overall, this paper offers a tailored approach to regulating biomass pyrolysis gases, enabling highly efficient battery recycling and syngas production.
- Open Access
- 28 June 2023
- Published by Springer Nature in Research Square
Needle-shaped beam optical coherence tomography angiography visualizing cortical blood perfusion after photothrombotic stroke in vivo
Optical imaging techniques provide low-cost, non-radiative images with high spatiotemporal resolution, making them advantageous for long-term dynamic observation of blood perfusion in stroke research and other brain studies compared to non-optical methods. However, high-resolution imaging in optical microscopy fundamentally requires a tight optical focus, and thus a limited depth of field (DOF). Consequently, large-scale, non-stitched, high-resolution images of curved surfaces, like brains, are difficult to acquire without z-axis scanning. To overcome this limitation, we developed a needle-shaped beam optical coherence tomography angiography (NB-OCTA) system, and for the first time, achieved a volumetric resolution of less than 8 µm in a non-stitched volume space of 6.4 mm × 4 mm × 620 µm in vivo. This system captures the distribution of blood vessels at 3.4-times larger depths than normal OCTA equipped with a Gaussian beam (GB-OCTA). We then employed NB-OCTA to perform long-term observation of cortical blood perfusion after stroke, and quantitatively analyzed the vessel area density (VAD) and the diameters of representative vessels in different regions over 10 days, revealing different spatiotemporal dynamics in the acute, sub-acute and chronic phase of post-ischemic revascularization. Benefiting from our NB-OCTA, we revealed that the recovery process is not only the result of spontaneous reperfusion, but also the formation of new vessels. This study provides visual and mechanistic insights into strokes and helps to deepen our understanding of the spontaneous response of brain after stroke.
- 28 June 2023
- Published by Springer Nature in Research Square
Open AccessNeedle-shaped beam optical coherence tomography angiography visualizing cortical blood perfusion after photothrombotic stroke in vivo
Optical imaging techniques provide low-cost, non-radiative images with high spatiotemporal resolution, making them advantageous for long-term dynamic observation of blood perfusion in stroke research and other brain studies compared to non-optical methods. However, high-resolution imaging in optical microscopy fundamentally requires a tight optical focus, and thus a limited depth of field (DOF). Consequently, large-scale, non-stitched, high-resolution images of curved surfaces, like brains, are difficult to acquire without z-axis scanning. To overcome this limitation, we developed a needle-shaped beam optical coherence tomography angiography (NB-OCTA) system, and for the first time, achieved a volumetric resolution of less than 8 µm in a non-stitched volume space of 6.4 mm × 4 mm × 620 µm in vivo. This system captures the distribution of blood vessels at 3.4-times larger depths than normal OCTA equipped with a Gaussian beam (GB-OCTA). We then employed NB-OCTA to perform long-term observation of cortical blood perfusion after stroke, and quantitatively analyzed the vessel area density (VAD) and the diameters of representative vessels in different regions over 10 days, revealing different spatiotemporal dynamics in the acute, sub-acute and chronic phase of post-ischemic revascularization. Benefiting from our NB-OCTA, we revealed that the recovery process is not only the result of spontaneous reperfusion, but also the formation of new vessels. This study provides visual and mechanistic insights into strokes and helps to deepen our understanding of the spontaneous response of brain after stroke.
- 6 February 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (4) , 3442-3451
Rapid Cellular-Resolution Skin Imaging with Optical Coherence Tomography Using All-Glass Multifocal Metasurfaces
Cellular-resolution optical coherence tomography (OCT) is a powerful tool offering noninvasive histology-like imaging. However, like other optical microscopy tools, a high numerical aperture (N.A.) lens is required to generate a tight focus, generating a narrow depth of field, which necessitates dynamic focusing and limiting the imaging speed. To overcome this limitation, we developed a metasurface platform that generates multiple axial foci, which multiplies the volumetric OCT imaging speed by offering several focal planes. This platform offers accurate and flexible control over the number, positions, and intensities of axial foci generated. All-glass metasurface optical elements 8 mm in diameter are fabricated from fused-silica wafers and implemented into our scanning OCT system. With a constant lateral resolution of 1.1 μm over all depths, the multifocal OCT triples the volumetric acquisition speed for dermatological imaging, while still clearly revealing features of stratum corneum, epidermal cells, and dermal-epidermal junctions and offering morphological information as diagnostic criteria for basal cell carcinoma. The imaging speed can be further improved in a sparse sample, e.g., 7-fold with a seven-foci beam. In summary, this work demonstrates the concept of metasurface-based multifocal OCT for rapid virtual biopsy, further providing insights for developing rapid volumetric imaging systems with high resolution and compact volume.
- 6 February 2023
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 17 (4) , 3442-3451
Rapid Cellular-Resolution Skin Imaging with Optical Coherence Tomography Using All-Glass Multifocal Metasurfaces
Cellular-resolution optical coherence tomography (OCT) is a powerful tool offering noninvasive histology-like imaging. However, like other optical microscopy tools, a high numerical aperture (N.A.) lens is required to generate a tight focus, generating a narrow depth of field, which necessitates dynamic focusing and limiting the imaging speed. To overcome this limitation, we developed a metasurface platform that generates multiple axial foci, which multiplies the volumetric OCT imaging speed by offering several focal planes. This platform offers accurate and flexible control over the number, positions, and intensities of axial foci generated. All-glass metasurface optical elements 8 mm in diameter are fabricated from fused-silica wafers and implemented into our scanning OCT system. With a constant lateral resolution of 1.1 μm over all depths, the multifocal OCT triples the volumetric acquisition speed for dermatological imaging, while still clearly revealing features of stratum corneum, epidermal cells, and dermal-epidermal junctions and offering morphological information as diagnostic criteria for basal cell carcinoma. The imaging speed can be further improved in a sparse sample, e.g., 7-fold with a seven-foci beam. In summary, this work demonstrates the concept of metasurface-based multifocal OCT for rapid virtual biopsy, further providing insights for developing rapid volumetric imaging systems with high resolution and compact volume.
- 14 April 2022
- Published by Elsevier in Journal of Geodynamics
- Vol. 151, 101920
The 2021 Mw7.4 Maduo earthquake: Coseismic slip model, triggering effect of historical earthquakes and implications for adjacent fault rupture potential
- 14 April 2022
- Published by Elsevier in Journal of Geodynamics
- Vol. 151, 101920
The 2021 Mw7.4 Maduo earthquake: Coseismic slip model, triggering effect of historical earthquakes and implications for adjacent fault rupture potential