Jingjing Zhao

Jingjing Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jingjing Zhao has a total of 61 co-authors. Here are the top co-authors by number of shared publications:

  • Lin Du

    Department of Neurological Surgery, The Ohio State University, Columbus, USA

    4 shared publications
  • Aidan Van Vleck

    Department of Structural Biology, Stanford University School of Medicine, Stanford, California 94305, United States

    3 shared publications
  • Adam de la Zerda

    Department of Structural Biology, Stanford University School of Medicine, Stanford, California 94305, United States

    2 shared publications
  • Adam de la Zerda

    Department of Structural Biology, Stanford University School of Medicine, Stanford University, Stanford, USA

    2 shared publications
  • Kaitlyn Liang

    Department of Radiology, Stanford University School of Medicine, Stanford, California 94305, United States

    2 shared publications
  • Lingqi Jiang

    Department of Precision Instrument, Tsinghua University, Beijing, China

    2 shared publications

Latest Publications

  • Open Access

    Grass carp catalase inhibits GCRV replication through ROS scavenging-mediated immune suppression and autophagy

    by Xuyang Wang, Xiaowen Zou, Linlin Liu, Xinyu Liang, Hanyue Wang, Cheng Yang, Yongming Li, Lanjie Liao, Zuoyan Zhu, Yaping Wang, et al.

    1. Reactive oxygen species (ROS) are highly reactive molecules derived from oxygen that can trigger a variety of chemical processes within biological systems. This group includes species such as su...


  • Open Access

    Needle beam two-photon microscopy for simultaneous multiplane neural and vascular imaging in awake mice

    by Quanyu Zhou, Jingjing Zhao, Chaim Glück, Yu-Hang Liu, Lin Du, Lukas Glandorf, Tian Jin, Zhenyue Chen, Lingqi Jiang, Bruno Weber, et al.

    Comprehensive understanding of brain functions necessitates high-speed imaging of neuronal and vascular dynamics across extensive volumes. Functional neuroimaging investigations with two-photon microscopy are commonly hindered by its limited depth of field which restricts imaging rates across multiple planes. We introduce needle-shaped beam two-photon microscopy (NB-2PM), a versatile platform for high-throughput neurovascular imaging at sub-cellular resolution across multiple depths. It employs customized diffractive optical elements to generate single- or multi-plane needle beams with up to 10 times elongated depth of field relative to Rayleigh lengths and engineered axial energy distribution to effectively offset light attenuation with depth. The proposed method was applied to snapshot volumetric vascular imaging and multi-plane neurovascular dynamic recordings of resting state and stimulus-evoked activity in mice. NB-2PM can seamlessly be integrated into existing microscopy systems, thus providing a scalable platform for gaining comprehensive insights into the functional architecture of murine brain.


  • Open Access

    Wearable optical coherence tomography angiography probe with extended depth of field

    by Xiaochen Li, Xiangyu Guo, Xinyue Wang, Lingqi Jiang, Mingxin Li, Xiaochuan Dai, Qun Hao, Jingjing Zhao, Yong Huang, Liqun Sun

    The advancement of biomedical imaging technology has significantly enhanced our understanding of complex physiological processes and the diagnosis of various health issues.1 – 3 Understanding the cerebral hemodynamics in rodents is a crucial question of interest in the fields of neuroscience, physiology, psychology, and imaging.4,5 The vast majority of traditional imaging techniques require the subject animals to remain still or be anesthetized to ensure image quality and stability, classic optical imaging setups for mouse brains typically involve fixing the mouse’s head beneath the lens, and throughout the imaging process, gas anesthetics are delivered to the mouse through a tube and a mask. These setups are widely used in two-photon microscopy,6 photoacoustic imaging,7 and optical coherence tomography (OCT).8 However, under anesthesia, multiple physiological indicators can be affected, leading to research results that may not fully represent the true physiological state.9 Therefore, there is a growing awareness of the necessity to image the brain under fully awake conditions.

  • Extending Depth-of-Field of Arbitrary Diffractive Optics with Needle-Shaped Beam Modulation

    by Jingjing Zhao, Kaitlyn Liang, Aidan Van Vleck, Lin Du, Yonatan Winetraub, Yifan Peng, Adam de la Zerda


  • Balancing the Components of Biomass and the Reactivity of Pyrolysis Gas: Biomass-Assisted Recycling of Spent LiCoO2 Batteries

    by Fengyin Zhou, Hongya Wang, Shiyu Wang, Jingjing Zhao, Xin Qu, Danfeng Wang, Yuqi Cai, Zhiyu Zheng, Dihua Wang, Huayi Yin

    Waste biomass is one of the promising feedstocks to supply syngas that can be used as fuels, chemicals, reductants, etc. However, the relationship between the component of biomass and the constituent of pyrolysis gas remains unclear. Here, we study the pyrolysis behaviors of various biomasses and reveal the relationship between the biomass components and gas compositions. Further, different pyrolysis gases are applied for the reduction of spent lithium cobalt oxide (LiCoO2) below 500 °C. The pyrolysis gas with a higher concentration of CO has a higher reductivity to convert LiCoO2 to CoO and Li2CO3 with a conversion rate close to 100% in 1 h at 500 °C. The biomass rich in cellulose and with a lower content of lignin tends to produce pyrolysis gas with a high concentration of CO, which comes from the deliberate breakdown of carboxyl, carbonyl, ether, and ester linkages. Moreover, LiCoO2 exerts catalytic functions over the deoxygenation and enhancement of oxygenates and single-ring aromatics. Overall, this paper offers a tailored approach to regulating biomass pyrolysis gases, enabling highly efficient battery recycling and syngas production.


  • Open Access

    Needle-shaped beam optical coherence tomography angiography visualizing cortical blood perfusion after photothrombotic stroke in vivo

    by Yong Huang, Xiangyu Guo, Jingjing Zhao, Liqun Sun, Varun Gupta, Lin Du, Komal Sharma, Aidan Van Vleck, Kaitlyn Liang, Liangcai Cao, et al.

    Optical imaging techniques provide low-cost, non-radiative images with high spatiotemporal resolution, making them advantageous for long-term dynamic observation of blood perfusion in stroke research and other brain studies compared to non-optical methods. However, high-resolution imaging in optical microscopy fundamentally requires a tight optical focus, and thus a limited depth of field (DOF). Consequently, large-scale, non-stitched, high-resolution images of curved surfaces, like brains, are difficult to acquire without z-axis scanning. To overcome this limitation, we developed a needle-shaped beam optical coherence tomography angiography (NB-OCTA) system, and for the first time, achieved a volumetric resolution of less than 8 µm in a non-stitched volume space of 6.4 mm × 4 mm × 620 µm in vivo. This system captures the distribution of blood vessels at 3.4-times larger depths than normal OCTA equipped with a Gaussian beam (GB-OCTA). We then employed NB-OCTA to perform long-term observation of cortical blood perfusion after stroke, and quantitatively analyzed the vessel area density (VAD) and the diameters of representative vessels in different regions over 10 days, revealing different spatiotemporal dynamics in the acute, sub-acute and chronic phase of post-ischemic revascularization. Benefiting from our NB-OCTA, we revealed that the recovery process is not only the result of spontaneous reperfusion, but also the formation of new vessels. This study provides visual and mechanistic insights into strokes and helps to deepen our understanding of the spontaneous response of brain after stroke.

  • Rapid Cellular-Resolution Skin Imaging with Optical Coherence Tomography Using All-Glass Multifocal Metasurfaces

    by Jingjing Zhao, Aidan Van Vleck, Yonatan Winetraub, Lin Du, Yong Han, Sumaira Aasi, Kavita Yang Sarin, Adam de la Zerda

    Cellular-resolution optical coherence tomography (OCT) is a powerful tool offering noninvasive histology-like imaging. However, like other optical microscopy tools, a high numerical aperture (N.A.) lens is required to generate a tight focus, generating a narrow depth of field, which necessitates dynamic focusing and limiting the imaging speed. To overcome this limitation, we developed a metasurface platform that generates multiple axial foci, which multiplies the volumetric OCT imaging speed by offering several focal planes. This platform offers accurate and flexible control over the number, positions, and intensities of axial foci generated. All-glass metasurface optical elements 8 mm in diameter are fabricated from fused-silica wafers and implemented into our scanning OCT system. With a constant lateral resolution of 1.1 μm over all depths, the multifocal OCT triples the volumetric acquisition speed for dermatological imaging, while still clearly revealing features of stratum corneum, epidermal cells, and dermal-epidermal junctions and offering morphological information as diagnostic criteria for basal cell carcinoma. The imaging speed can be further improved in a sparse sample, e.g., 7-fold with a seven-foci beam. In summary, this work demonstrates the concept of metasurface-based multifocal OCT for rapid virtual biopsy, further providing insights for developing rapid volumetric imaging systems with high resolution and compact volume.