Marius Darie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marius Darie has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Tiberiu Csaszar
National Institute for Research and Development in Mine Safety and Protection to Explosion - INSEMEX
4 shared publicationsSorin Burian
National Institute for Research and Development in Mine Safety and Protection to Explosion - INSEMEX
3 shared publicationsCosmin Colda
National Institute for Research and Development in Mine Safety and Protection to Explosion - INSEMEX
2 shared publications- Marius Marcu
Automation, Computer, Electrical and Power Department, University of Petrosani, 332006 Petrosani, Romania
2 shared publications Adriana Andriș
National Institute for Mine Safety and Protection to Explosion - INSEMEX, Department for Safety of Installations and Explosion-proof Equipment, 32-34 G-ral Vasile Milea, Petroșani, Romania
1 shared publication- Cosmin Cernazanu-Glavan
Department of Computer and Information Technology, Universitatea Politehnica Timişoara
1 shared publication
Latest Publications
- Open Access
- 18 October 2024
- Published by Elsevier in Atmospheric Environment
- Vol. 339
Calibration of NO, SO2, and PM using Airify: A low-cost sensor cluster for air quality monitoring
- 18 October 2024
- Published by Elsevier in Atmospheric Environment
- Vol. 339
Open AccessCalibration of NO, SO2, and PM using Airify: A low-cost sensor cluster for air quality monitoring
- 15 November 2022
- Published by STEF92 Technology
- Vol. 22, 661-666
SMALL COMPONENT IGNITION TESTS UNCERTAINTY ESTIMATION
The paper presents issues regarding uncertainty involved in the test process to ignition of small components for intrinsically safe equipment. In the first part of the paper, the classification of explosion-protected equipment is presented. In power generation and also in other industrial areas, the incidence of flammable substances is a common factor. As a consequence of this, the risk of explosion may arise. On the other hand, installations located in areas endangered by the presence of flammable substances must remain in operation and therefore live. The equipment in the installations must be assessed, tested, and certified for use in explosive atmospheres if they are to be operated safely. In the second part, the requirements of the intrinsically safe type of protection and the necessary aspects of ignition testing of small components are presented. The third part presents the model for uncertainty assessment of the testing mixture and the uncertainty in the determination of the temperature of the component under test. The results obtained are also presented and discussed. The approach concludes that the resulting uncertainty in the test process does not significantly affect the test results.
- 15 November 2022
- Published by STEF92 Technology
- Vol. 22, 661-666
SMALL COMPONENT IGNITION TESTS UNCERTAINTY ESTIMATION
The paper presents issues regarding uncertainty involved in the test process to ignition of small components for intrinsically safe equipment. In the first part of the paper, the classification of explosion-protected equipment is presented. In power generation and also in other industrial areas, the incidence of flammable substances is a common factor. As a consequence of this, the risk of explosion may arise. On the other hand, installations located in areas endangered by the presence of flammable substances must remain in operation and therefore live. The equipment in the installations must be assessed, tested, and certified for use in explosive atmospheres if they are to be operated safely. In the second part, the requirements of the intrinsically safe type of protection and the necessary aspects of ignition testing of small components are presented. The third part presents the model for uncertainty assessment of the testing mixture and the uncertainty in the determination of the temperature of the component under test. The results obtained are also presented and discussed. The approach concludes that the resulting uncertainty in the test process does not significantly affect the test results.
- 15 November 2022
- Published by STEF92 Technology
- Vol. 22, 653-660
RISKS INDUCED BY IMPROPER INSTALLATION AND MAINTENANCE OF EQUIPMENT INTENDED FOR OPERATION IN POTENTIALLY EXPLOSIVE ENVIRONMENTS
The installation and maintenance of equipment intended for use in potentially explosive environments requires specific knowledge and qualifications for the personnel who commissions and subsequently maintain such equipment. When installing and maintaining electrical equipment, situations may arise which may in turn lead to an unacceptable level of risk with regarding to the activation of ignition sources of potentially explosive atmospheres in their immediate vicinity, due to the failure to comply the principles of explosion protection. The principles of explosion protection differ from one type of equipment to another, and they can be combined, but only if the clearly defined principles in the specific literature are observed. There are also situations when two or more principles of protection are not compatible in ensuring a level of safety appropriate to the classification of the area endangered by the presence of a potentially explosive atmosphere. This paper presents real situations discovered by the authors in their assessment work, at different installations intended for operation in potentially explosive environments, with the highlighting of the nonconformities in each presented case.
- 15 November 2022
- Published by STEF92 Technology
- Vol. 22, 653-660
RISKS INDUCED BY IMPROPER INSTALLATION AND MAINTENANCE OF EQUIPMENT INTENDED FOR OPERATION IN POTENTIALLY EXPLOSIVE ENVIRONMENTS
The installation and maintenance of equipment intended for use in potentially explosive environments requires specific knowledge and qualifications for the personnel who commissions and subsequently maintain such equipment. When installing and maintaining electrical equipment, situations may arise which may in turn lead to an unacceptable level of risk with regarding to the activation of ignition sources of potentially explosive atmospheres in their immediate vicinity, due to the failure to comply the principles of explosion protection. The principles of explosion protection differ from one type of equipment to another, and they can be combined, but only if the clearly defined principles in the specific literature are observed. There are also situations when two or more principles of protection are not compatible in ensuring a level of safety appropriate to the classification of the area endangered by the presence of a potentially explosive atmosphere. This paper presents real situations discovered by the authors in their assessment work, at different installations intended for operation in potentially explosive environments, with the highlighting of the nonconformities in each presented case.
- Open Access
- 6 January 2022
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 354, 00040
On the estimation of maximum surface temperature for cells
In paperwork is presented the estimation of the maximum surface temperature of cells exposed to specific tests for the intrinsic safety type of protection. Particularly, it presents the thermal resistance of the short-circuit test-stand results. The first part introduces the aspects regarding the risk of explosion. The risk of explosion occurs due to the presence of technical equipment in areas where flammable substances may occur. The second part itemizes the requirements for the testing of cells. Also, is introduced the stand configuration and performance aspects. The third part of the paper has been dedicated to the presentation and the discussion of the obtained results. The analysis of the test results highlighted the range of thermal resistance. This result could help estimation of the surface temperature of cells based on their capacity and internal resistance. The convection coefficients were determined. The process of deep discharge destroys the inner electrochemical of the cell system. Therefore, it permits energy recovery lower than a fraction of a tenth.
- 6 January 2022
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 354, 00040
Open AccessOn the estimation of maximum surface temperature for cells
In paperwork is presented the estimation of the maximum surface temperature of cells exposed to specific tests for the intrinsic safety type of protection. Particularly, it presents the thermal resistance of the short-circuit test-stand results. The first part introduces the aspects regarding the risk of explosion. The risk of explosion occurs due to the presence of technical equipment in areas where flammable substances may occur. The second part itemizes the requirements for the testing of cells. Also, is introduced the stand configuration and performance aspects. The third part of the paper has been dedicated to the presentation and the discussion of the obtained results. The analysis of the test results highlighted the range of thermal resistance. This result could help estimation of the surface temperature of cells based on their capacity and internal resistance. The convection coefficients were determined. The process of deep discharge destroys the inner electrochemical of the cell system. Therefore, it permits energy recovery lower than a fraction of a tenth.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of home appliances' functional regimes using power signatures
The last years have seen major transformation in all segments of the power industry, from power generation to energy supply, smart meters having a key role. Smart energy meters are used also in smart homes solutions. Non-intrusive load monitoring using smart meters can be used to disaggregate energy consumption of home appliances. In our work we aim to estimate energy consumption and power profile of the internal components of an electrical device using the electrical energy signature of the running device. Furthermore, we try to determine the operation mode of the device under analysis based on the differences between power consumption signatures.
- 1 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Comparative analysis of home appliances' functional regimes using power signatures
The last years have seen major transformation in all segments of the power industry, from power generation to energy supply, smart meters having a key role. Smart energy meters are used also in smart homes solutions. Non-intrusive load monitoring using smart meters can be used to disaggregate energy consumption of home appliances. In our work we aim to estimate energy consumption and power profile of the internal components of an electrical device using the electrical energy signature of the running device. Furthermore, we try to determine the operation mode of the device under analysis based on the differences between power consumption signatures.
- 1 January 2012
- Published by OAIMDD - EcoZone Publishing House in Environmental Engineering and Management Journal
- Vol. 11 (7) , 1281-1285
METHOD FOR ASSESSING ENERGY LIMITED SUPPLY SOURCES, DESIGNED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES
- 1 January 2012
- Published by OAIMDD - EcoZone Publishing House in Environmental Engineering and Management Journal
- Vol. 11 (7) , 1281-1285
METHOD FOR ASSESSING ENERGY LIMITED SUPPLY SOURCES, DESIGNED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES