Peng Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Peng Yuan has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Zhongkun Qiao
Zhejiang University of Technology
6 shared publications - Bin Wu
Key Laboratory of Quantum Precision Measurement of Zhejiang Province, School of Physics, Zhejiang University of Technology, Hangzhou, China
5 shared publications - Qiang Lin
State Key Laboratory of Ocean Sensing, Institute of Quantum Sensing, School of Physics, Zhejiang University, Hangzhou 310058, China
5 shared publications Bin Wu
4 shared publicationsYin Zhou
4 shared publications- Dong Zhu
Key Laboratory of Quantum Precision Measurement of Zhejiang Province, School of Physics, Zhejiang University of Technology, Hangzhou, China
3 shared publications
Latest Publications
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 8561-8572
Precision Evaluation of Continuous Observation Gravimeters Based on CEEMD Method
High-precision gravity observation is key to studying Earth’s gravity field, which reflects matter distribution and movement of matter within the Earth’s interior, on its surface, and in outer space. Compared to traditional mobile observations, continuous gravity array observations can effectively improve both accuracy and temporal resolution. The China Earthquake Administration has deployed a total of 115 continuous gravimeters, including superconducting gravimeters (SG), atom gravimeters (AG), and spring gravimeters, preliminarily establishing a continuous gravity observation network. However, the accuracy differences among different types of instruments constrain the comprehensive application of the data. To address this, it is imperative to conduct research on the accuracy evaluation of various gravimeters. This study innovatively introduces the Complementary Ensemble Empirical Mode Decomposition (CEEMD) algorithm to decompose and reconstruct the measured data from continuous gravimeters, extracting the solid Earth tide signal. Subsequently, an external conformity accuracy evaluation is performed by comparing it with theoretical tidal models, thereby achieving instrument accuracy assessment. To verify the feasibility and superiority of the CEEMD algorithm, this paper first designs a combined simulation signal experiment, in which the performance of Bessel filtering, Kalman filtering, Variational Mode Decomposition (VMD), Empirical Mode Decomposition (EMD), and CEEMD in extracting tidal frequency band signals is comparatively analyzed. Finally, these methods are applied to process observational data from three gravimeters (SG, AG, and DZW relative gravimeter (DZW)) at the Yilan station, extracting the solid Earth tide signal and comparing its external conformity accuracy with theoretical models. The results show that these algorithms can effectively extract the solid Earth tide signal, with the evaluated accuracy of the three instruments consistently ranked as follows: SG > AG > DZW. However,The CEEMD method demonstrated optimal performance in the accuracy evaluation of the three gravimeters, with the following external conformity accuracies achieved: SG: 1.83 μGal, AG: 2.59 μGal, DZW: 3.83 μGal.
- 28 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 8561-8572
Precision Evaluation of Continuous Observation Gravimeters Based on CEEMD Method
High-precision gravity observation is key to studying Earth’s gravity field, which reflects matter distribution and movement of matter within the Earth’s interior, on its surface, and in outer space. Compared to traditional mobile observations, continuous gravity array observations can effectively improve both accuracy and temporal resolution. The China Earthquake Administration has deployed a total of 115 continuous gravimeters, including superconducting gravimeters (SG), atom gravimeters (AG), and spring gravimeters, preliminarily establishing a continuous gravity observation network. However, the accuracy differences among different types of instruments constrain the comprehensive application of the data. To address this, it is imperative to conduct research on the accuracy evaluation of various gravimeters. This study innovatively introduces the Complementary Ensemble Empirical Mode Decomposition (CEEMD) algorithm to decompose and reconstruct the measured data from continuous gravimeters, extracting the solid Earth tide signal. Subsequently, an external conformity accuracy evaluation is performed by comparing it with theoretical tidal models, thereby achieving instrument accuracy assessment. To verify the feasibility and superiority of the CEEMD algorithm, this paper first designs a combined simulation signal experiment, in which the performance of Bessel filtering, Kalman filtering, Variational Mode Decomposition (VMD), Empirical Mode Decomposition (EMD), and CEEMD in extracting tidal frequency band signals is comparatively analyzed. Finally, these methods are applied to process observational data from three gravimeters (SG, AG, and DZW relative gravimeter (DZW)) at the Yilan station, extracting the solid Earth tide signal and comparing its external conformity accuracy with theoretical models. The results show that these algorithms can effectively extract the solid Earth tide signal, with the evaluated accuracy of the three instruments consistently ranked as follows: SG > AG > DZW. However,The CEEMD method demonstrated optimal performance in the accuracy evaluation of the three gravimeters, with the following external conformity accuracies achieved: SG: 1.83 μGal, AG: 2.59 μGal, DZW: 3.83 μGal.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Feasibility Study on Using Atomic Gravimeters for Detecting Urban Underground Spaces
Microgravity measurement offers several benefits: it is highly efficient, cost-effective, resistant to interference, and non-destructive. This technique is especially valuable for exploring urban underground spaces and identifying issues such as surface collapses, underground cavities, karst formations, and other geological anomalies. The Atomic Gravimeter (AG), which is based on atom interferometry, provides high precision, and continuous measurement without drift. It is suitable for detecting urban underground spaces and for long-term monitoring of geological high-risk areas. This study demonstrates the potential of an independently developed AG by Zhejiang University of Technology (ZJUT) for microgravity measurements. It also examines the potential of AG as a local reference for relative gravimeters by performing cross-bridge microgravity profile measurements and validating the results with theoretical model simulations. The estimated sensitivity of the AG without the vibration isolation platform is approximately 135.1 μGal/Hz1/2, achieving a resolution of about 3 μGal (1 μGal=10-8 m/s2) with an integration time of 2000 s. Additionally, this study conducted cross-bridge experiments with two spring gravimeters, CG-6 and Burris, to assess their effectiveness for detecting urban underground features and to evaluate the accuracy of these conventional instruments. Due to issues like zero drift in the relative gravimeters, the comparison with AG measurements showed external coincidence accuracies of 8.5±8.8 μGal for the CG-6 and 7.1±7.9 μGal for the Burris. Overall, AGs demonstrate superior detection accuracy and offer significant potential for applications in urban underground space detection.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Feasibility Study on Using Atomic Gravimeters for Detecting Urban Underground Spaces
Microgravity measurement offers several benefits: it is highly efficient, cost-effective, resistant to interference, and non-destructive. This technique is especially valuable for exploring urban underground spaces and identifying issues such as surface collapses, underground cavities, karst formations, and other geological anomalies. The Atomic Gravimeter (AG), which is based on atom interferometry, provides high precision, and continuous measurement without drift. It is suitable for detecting urban underground spaces and for long-term monitoring of geological high-risk areas. This study demonstrates the potential of an independently developed AG by Zhejiang University of Technology (ZJUT) for microgravity measurements. It also examines the potential of AG as a local reference for relative gravimeters by performing cross-bridge microgravity profile measurements and validating the results with theoretical model simulations. The estimated sensitivity of the AG without the vibration isolation platform is approximately 135.1 μGal/Hz1/2, achieving a resolution of about 3 μGal (1 μGal=10-8 m/s2) with an integration time of 2000 s. Additionally, this study conducted cross-bridge experiments with two spring gravimeters, CG-6 and Burris, to assess their effectiveness for detecting urban underground features and to evaluate the accuracy of these conventional instruments. Due to issues like zero drift in the relative gravimeters, the comparison with AG measurements showed external coincidence accuracies of 8.5±8.8 μGal for the CG-6 and 7.1±7.9 μGal for the Burris. Overall, AGs demonstrate superior detection accuracy and offer significant potential for applications in urban underground space detection.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20940-20948
Joint Inversion of Gravity and Gravity Gradient Data Based on Cross-Gradient Function
Gravity exploration is one of the most commonly used geophysical exploration methods, and it is widely used in the field of mineral resources’ exploration and engineering survey benefited from its advantages of large exploration depth, economy, and high efficiency. Gravity and its gradient data reflect the different distribution characteristics of subsurface anomalous objects, and therefore, the single data inversion cannot achieve an accurate identification for the underground objects and suffer from stronger nonuniqueness problems. To accurately identify the location and distribution characteristics of subsurface objects, we first construct models to perform separate inversions of gravity and gravity gradient data, analyze the identification ability of different anomaly components, and then innovatively introduce a cross-gradient function for the joint inversion of two gravity tensor data, ${V}_{ {xx}}$ and ${V}_{ {yy}}$ . The results show that the method combines the advantages of these two components and reflects the horizontal position of the targeted bodies more accurately; meanwhile, the portrayal of the boundary is also closer to the real model. Finally, we apply the above method to the Vinton Dome, and the inversion results recover the accurate spatial location of the Vinton Dome. The practical application results show that the joint cross-gradient inversion of gravity and gravity gradient data is more efficient for spatial location trapping and boundary inscription of subsurface targeted bodies compared with the inversion of individual component.
- 16 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (13) , 20940-20948
Joint Inversion of Gravity and Gravity Gradient Data Based on Cross-Gradient Function
Gravity exploration is one of the most commonly used geophysical exploration methods, and it is widely used in the field of mineral resources’ exploration and engineering survey benefited from its advantages of large exploration depth, economy, and high efficiency. Gravity and its gradient data reflect the different distribution characteristics of subsurface anomalous objects, and therefore, the single data inversion cannot achieve an accurate identification for the underground objects and suffer from stronger nonuniqueness problems. To accurately identify the location and distribution characteristics of subsurface objects, we first construct models to perform separate inversions of gravity and gravity gradient data, analyze the identification ability of different anomaly components, and then innovatively introduce a cross-gradient function for the joint inversion of two gravity tensor data, ${V}_{ {xx}}$ and ${V}_{ {yy}}$ . The results show that the method combines the advantages of these two components and reflects the horizontal position of the targeted bodies more accurately; meanwhile, the portrayal of the boundary is also closer to the real model. Finally, we apply the above method to the Vinton Dome, and the inversion results recover the accurate spatial location of the Vinton Dome. The practical application results show that the joint cross-gradient inversion of gravity and gravity gradient data is more efficient for spatial location trapping and boundary inscription of subsurface targeted bodies compared with the inversion of individual component.
- Open Access
- 8 March 2024
- Published by Copernicus GmbH
Application Study Of Ocean Absolute Gravity Measurement Based On Atomic Gravimeter
The gravity field stands as an intrinsic property of the Earth, providing insights into the distribution and dynamics of substances within the planet and their evolving states. Ocean gravity is a crucial aspect of the Earth's gravity field, with significant applicative value in ocean resource development, geoscientific research, and the interpretation of geological structures. Accurate ocean gravity measurement data serves as essential foundational information for investigating the geological and tectonic features of maritime areas. It is instrumental in identifying distribution patterns and assessing the storage status of mineral resources. The conventional time-varying gravity field relies primarily on GRACE satellite gravity. However, with its spatial resolution limited to approximately 300-500 km half-wavelength, it falls short of meeting the requirements for detailed investigations into local seafloor tectonics and changes in seafloor topography. Presently, shipboard ocean gravity measurement stands out as the most effective method for acquiring high-precision ocean gravity field information. This approach is versatile, suitable for both deep-water measurements in expansive sea regions and measurements in near-shore and island-rimmed sea areas, where the accuracy of satellite altimetry inversion for the gravity field is limited. Conventional ocean gravity measurement predominantly relies on relative gravity measurement, employing a core sensor with quartz and metal spring components. However, this sensor is marred by drawbacks such as mechanical abrasion, elastic fatigue, and creep, leading to instrument zero drift and inadequate long-term stability. Periodic return to the ship is necessary for error calibration and alignment, significantly impacting the efficiency and accuracy of gravity measurement. The atomic gravimeter, leveraging cold atom interference technology, presents notable advantages such as low drift, high accuracy, and excellent long-term stability. It can be seamlessly integrated with traditional gravimeters to achieve dynamic measurements of high-precision gravity fields over extended periods and across vast ocean expanses. Advances in laser, vacuum, electronic control, and related technologies have significantly enhanced atomic gravimeters in terms of accuracy, compactness, miniaturization, and intelligence. Consequently, advancing from static measurements conducted in laboratories, atomic gravimeters are gradually transitioning to dynamic measurements aboard ships and airborne platforms. The Quantum Precision Measurement Team at Zhejiang University of Technology has achieved successful ocean absolute gravity measurements using an independently developed atomic gravimeter (see Figure 1). The instrument consistently exhibits internal conformity accuracy within 0.6 mGal along repeated lines. Moreover, when compared with a commercial ocean relative gravity instrument on the same ship, the external conformity accuracy falls within the range of 0.5-1.5 mGal. These results meet the precision requirements for ocean gravity measurements, positioning the atomic gravimeter as a potential cornerstone in ocean gravity measurement instruments. Figure 1 ZAG Shipboard Absolute Gravity Measurement System. (a) Dedicated inertial stabilization platform for atomic gravity. (b) Mobile laboratory for shipboard absolute gravity measurement system. (c) Composition of the atomic gravity instrument system, primarily consisting of the electronic control system and vacuum sensor head system.
- 8 March 2024
- Published by Copernicus GmbH
Open AccessApplication Study Of Ocean Absolute Gravity Measurement Based On Atomic Gravimeter
The gravity field stands as an intrinsic property of the Earth, providing insights into the distribution and dynamics of substances within the planet and their evolving states. Ocean gravity is a crucial aspect of the Earth's gravity field, with significant applicative value in ocean resource development, geoscientific research, and the interpretation of geological structures. Accurate ocean gravity measurement data serves as essential foundational information for investigating the geological and tectonic features of maritime areas. It is instrumental in identifying distribution patterns and assessing the storage status of mineral resources. The conventional time-varying gravity field relies primarily on GRACE satellite gravity. However, with its spatial resolution limited to approximately 300-500 km half-wavelength, it falls short of meeting the requirements for detailed investigations into local seafloor tectonics and changes in seafloor topography. Presently, shipboard ocean gravity measurement stands out as the most effective method for acquiring high-precision ocean gravity field information. This approach is versatile, suitable for both deep-water measurements in expansive sea regions and measurements in near-shore and island-rimmed sea areas, where the accuracy of satellite altimetry inversion for the gravity field is limited. Conventional ocean gravity measurement predominantly relies on relative gravity measurement, employing a core sensor with quartz and metal spring components. However, this sensor is marred by drawbacks such as mechanical abrasion, elastic fatigue, and creep, leading to instrument zero drift and inadequate long-term stability. Periodic return to the ship is necessary for error calibration and alignment, significantly impacting the efficiency and accuracy of gravity measurement. The atomic gravimeter, leveraging cold atom interference technology, presents notable advantages such as low drift, high accuracy, and excellent long-term stability. It can be seamlessly integrated with traditional gravimeters to achieve dynamic measurements of high-precision gravity fields over extended periods and across vast ocean expanses. Advances in laser, vacuum, electronic control, and related technologies have significantly enhanced atomic gravimeters in terms of accuracy, compactness, miniaturization, and intelligence. Consequently, advancing from static measurements conducted in laboratories, atomic gravimeters are gradually transitioning to dynamic measurements aboard ships and airborne platforms. The Quantum Precision Measurement Team at Zhejiang University of Technology has achieved successful ocean absolute gravity measurements using an independently developed atomic gravimeter (see Figure 1). The instrument consistently exhibits internal conformity accuracy within 0.6 mGal along repeated lines. Moreover, when compared with a commercial ocean relative gravity instrument on the same ship, the external conformity accuracy falls within the range of 0.5-1.5 mGal. These results meet the precision requirements for ocean gravity measurements, positioning the atomic gravimeter as a potential cornerstone in ocean gravity measurement instruments. Figure 1 ZAG Shipboard Absolute Gravity Measurement System. (a) Dedicated inertial stabilization platform for atomic gravity. (b) Mobile laboratory for shipboard absolute gravity measurement system. (c) Composition of the atomic gravity instrument system, primarily consisting of the electronic control system and vacuum sensor head system.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10620-10631
Analysis and Processing of Vibration Interference Error of Oceanic Absolute Gravity Measurement Based on Variational Mode Decomposition
The atomic gravimeter is a very precise device ideal for ocean gravity field measurements. However, noise from various sources in the ocean environment, such as the waves, ship engines, and propeller systems, affects its accuracy. The noise interferes with the vibrations of the atomic gravimeter, which are non-linear and non-smooth. To address this issue, in this study, the Variational Mode Decomposition (VMD) algorithm is proposed to analyze and process the vibration interference. Firstly, the algorithm is used to analyze the amplitude and central frequency of vibration disturbances in dock, mooring, and navigation environments. Secondly, the measured vibration data and the gravimeter sensitivity function are convolved to obtain the total and each-frequency band contribution of vibration noise. The findings indicate that under navigation, the vibration noise is primarily concentrated in frequencies below 1 Hz, representing approximately 99.91% of the overall vibration noise spectrum. Additionally, a prominent peak is evident near 0.2 Hz, displaying an amplitude exceeding 5 Gal, believed to be associated with the rocking motion of the ship. Finally, despite employing vibration compensation, the intricate interference in shipborne gravity measurements leads to residual noise, with amplitudes reaching up to 10 mGal. To improve the quality of ocean absolute gravity data, the VMD algorithm is employed for efficient noise filtering. This research can help optimize the vibration isolation system of the atomic gravimeter and improve the signal-to-noise ratio (SNR) of the measurement data. This will the use of the atomic gravimeter for exploration of marine resources and global gravity field mapping.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10620-10631
Analysis and Processing of Vibration Interference Error of Oceanic Absolute Gravity Measurement Based on Variational Mode Decomposition
The atomic gravimeter is a very precise device ideal for ocean gravity field measurements. However, noise from various sources in the ocean environment, such as the waves, ship engines, and propeller systems, affects its accuracy. The noise interferes with the vibrations of the atomic gravimeter, which are non-linear and non-smooth. To address this issue, in this study, the Variational Mode Decomposition (VMD) algorithm is proposed to analyze and process the vibration interference. Firstly, the algorithm is used to analyze the amplitude and central frequency of vibration disturbances in dock, mooring, and navigation environments. Secondly, the measured vibration data and the gravimeter sensitivity function are convolved to obtain the total and each-frequency band contribution of vibration noise. The findings indicate that under navigation, the vibration noise is primarily concentrated in frequencies below 1 Hz, representing approximately 99.91% of the overall vibration noise spectrum. Additionally, a prominent peak is evident near 0.2 Hz, displaying an amplitude exceeding 5 Gal, believed to be associated with the rocking motion of the ship. Finally, despite employing vibration compensation, the intricate interference in shipborne gravity measurements leads to residual noise, with amplitudes reaching up to 10 mGal. To improve the quality of ocean absolute gravity data, the VMD algorithm is employed for efficient noise filtering. This research can help optimize the vibration isolation system of the atomic gravimeter and improve the signal-to-noise ratio (SNR) of the measurement data. This will the use of the atomic gravimeter for exploration of marine resources and global gravity field mapping.
- 5 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (13) , 14346-14355
Error Analysis and Filtering Methods for Absolute Ocean Gravity Data
The atomic gravimeter has advantages of high accuracy and long-term stability, which is suitable for high-resolution absolute sea-surface and deep-sea gravity measurements. The absolute gravity data measured by the atomic gravimeter are affected by rough sea conditions, with significant non-smooth and non-linear noise signals, which reduce the accuracy of gravity measurements. To eliminate the noises in measured gravity data, this paper analyzed the noise sources and innovatively introduced the Variational Modal Decomposition algorithm according to the noise characteristics. Since the filtering result of Variational Modal Decomposition algorithm is limited by the selection of parameters like modal number K and penalty factor α, a Particle Swarm Optimization algorithm and envelope entropy were introduced to adaptively determine the parameters K and α, obtaining the optimal decomposition solution. To verify the reliability of the method, we processed the ocean gravity data, which were dynamically measured by atomic gravimeter (ZAG-M), by using the Empirical Mode Decomposition algorithm, the Complete Ensemble EMD with Adaptive Noise algorithm, and the PSO-VMD algorithm, respectively. The evaluated external coincidence accuracy acquired by comparing the ZAG-M with the ocean relative gravimeter (KSS-32) deployed on the same ship are 0. 71 mGal, 0.54 mGal and 0.48 mGal, respectively, confirming that the PSO-VMD filtering algorithm has a better filtering performance. Finally, the PSO-VMD was applied to all the lines of this ocean measurement experiment with an internal coincidence accuracy of 0.62mGal, verifying the stability of the ZAG-M atomic absolute gravimeter in ocean dynamic measurements and the effectiveness of the proposed algorithm.
- 5 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (13) , 14346-14355
Error Analysis and Filtering Methods for Absolute Ocean Gravity Data
The atomic gravimeter has advantages of high accuracy and long-term stability, which is suitable for high-resolution absolute sea-surface and deep-sea gravity measurements. The absolute gravity data measured by the atomic gravimeter are affected by rough sea conditions, with significant non-smooth and non-linear noise signals, which reduce the accuracy of gravity measurements. To eliminate the noises in measured gravity data, this paper analyzed the noise sources and innovatively introduced the Variational Modal Decomposition algorithm according to the noise characteristics. Since the filtering result of Variational Modal Decomposition algorithm is limited by the selection of parameters like modal number K and penalty factor α, a Particle Swarm Optimization algorithm and envelope entropy were introduced to adaptively determine the parameters K and α, obtaining the optimal decomposition solution. To verify the reliability of the method, we processed the ocean gravity data, which were dynamically measured by atomic gravimeter (ZAG-M), by using the Empirical Mode Decomposition algorithm, the Complete Ensemble EMD with Adaptive Noise algorithm, and the PSO-VMD algorithm, respectively. The evaluated external coincidence accuracy acquired by comparing the ZAG-M with the ocean relative gravimeter (KSS-32) deployed on the same ship are 0. 71 mGal, 0.54 mGal and 0.48 mGal, respectively, confirming that the PSO-VMD filtering algorithm has a better filtering performance. Finally, the PSO-VMD was applied to all the lines of this ocean measurement experiment with an internal coincidence accuracy of 0.62mGal, verifying the stability of the ZAG-M atomic absolute gravimeter in ocean dynamic measurements and the effectiveness of the proposed algorithm.
- Open Access
- 13 February 2023
- Published by Wiley
Improvement of the accuracy of ocean tide model based on the offshore continuous gravity data with atomic gravimeter
Marine gravity measurements are critically affected by ocean tides effect. However, the model of ocean tidal loading (OTL) is not accurate enough for offshore high-precision gravity measurement at present. In this paper, we carry out the investigation of gravity variations for the measured location that is far from the shore. Currently, the OTL model calculates the effect of tidal waves globally. However, the influence of local mass changes on gravity measurement should be taken into account, especially when the observed location is far from the shore. For further verification, the gravity measurement experiments are carried out based on a homemade atomic gravimeter at a location, which is 230 m far away from the shore and surrounded by seawater. Even in the harsh measurement environment of the quay, the continuous monitoring of gravity variation has been done for about three days, and the measurement sensitivity of our atomic gravimeter is estimated to be 0.76 mGal$/\sqrt{\text{Hz}}$ for an interrogation time of 110 ms. Moreover, the gravity changes of approximately 170 $\upmu$Gal have been observed with the variation of regional seawater mass, which agree well with the calculated results based on the new modified model of OTL. The results of this paper may be helpful for the high-precision calibration of marine gravimeters.
- 13 February 2023
- Published by Wiley
Open AccessImprovement of the accuracy of ocean tide model based on the offshore continuous gravity data with atomic gravimeter
Marine gravity measurements are critically affected by ocean tides effect. However, the model of ocean tidal loading (OTL) is not accurate enough for offshore high-precision gravity measurement at present. In this paper, we carry out the investigation of gravity variations for the measured location that is far from the shore. Currently, the OTL model calculates the effect of tidal waves globally. However, the influence of local mass changes on gravity measurement should be taken into account, especially when the observed location is far from the shore. For further verification, the gravity measurement experiments are carried out based on a homemade atomic gravimeter at a location, which is 230 m far away from the shore and surrounded by seawater. Even in the harsh measurement environment of the quay, the continuous monitoring of gravity variation has been done for about three days, and the measurement sensitivity of our atomic gravimeter is estimated to be 0.76 mGal$/\sqrt{\text{Hz}}$ for an interrogation time of 110 ms. Moreover, the gravity changes of approximately 170 $\upmu$Gal have been observed with the variation of regional seawater mass, which agree well with the calculated results based on the new modified model of OTL. The results of this paper may be helpful for the high-precision calibration of marine gravimeters.
- 28 October 2016
- Published by Morressier GmbH
The Analysis and Stability of Tetrahydrouridine Solution and Capsule
- 28 October 2016
- Published by Morressier GmbH
The Analysis and Stability of Tetrahydrouridine Solution and Capsule