Masaharu Mizuno
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Masaharu Mizuno has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Takashi Koto
Department of Ophthalmology, Kyorin University School of Medicine, Tokyo, Japan
7 shared publications- Makoto Inoue
Kyorin Eye Center, Kyorin University School of Medicine, Mitaka, Japan
6 shared publications Tomoka Ishida
6 shared publicationsKosuke Nakajima
Department of Ophthalmology, Kyorin University School of Medicine, Tokyo, Japan
5 shared publicationsMakoto Inoue
4 shared publicationsAkito Hirakata
3 shared publications
Latest Publications
- 1 November 2026
- Published by Wolters Kluwer Health in RETINAL Cases & Brief Reports
- Vol. 20 (6) , 776-779
IMPROVEMENT OF MACULOPATHY ASSOCIATED WITH CAVITARY OPTIC DISK ANOMALIES TREATED WITH TOPICAL ANTIGLAUCOMA MEDICATIONS
Purpose: To report the findings in two cases of maculopathy associated with cavitary optic disk anomalies that were treated successfully with topical antiglaucoma medications. Methods: Two cases of maculopathy with cavitary optic disk anomalies were treated with topical antiglaucoma medications. The ophthalmoscopic and optical coherence tomographic images were recorded before and after beginning the antiglaucoma medications. Results: Both cases were young women who had a worsening of their visual acuity because of a serous retinal detachment. One woman had an optic disk pit maculopathy, and the other had a large optic disk with an atypical disk coloboma. After treatment with topical antiglaucoma medications, the subretinal fluid was resolved in both cases and the visual acuity was improved. Conclusion: The improvement of the maculopathy associated with cavitary optic disk anomalies was observed after the initiation of topical antiglaucoma eye drops. Although a spontaneous resolution cannot be excluded, these findings suggest that the decrease of intraocular pressure with antiglaucoma eye drops may be helpful in improving the retinopathy during the follow-up period in selective cases of cavitary optic disk anomalies.
- 1 November 2026
- Published by Wolters Kluwer Health in RETINAL Cases & Brief Reports
- Vol. 20 (6) , 776-779
IMPROVEMENT OF MACULOPATHY ASSOCIATED WITH CAVITARY OPTIC DISK ANOMALIES TREATED WITH TOPICAL ANTIGLAUCOMA MEDICATIONS
Purpose: To report the findings in two cases of maculopathy associated with cavitary optic disk anomalies that were treated successfully with topical antiglaucoma medications. Methods: Two cases of maculopathy with cavitary optic disk anomalies were treated with topical antiglaucoma medications. The ophthalmoscopic and optical coherence tomographic images were recorded before and after beginning the antiglaucoma medications. Results: Both cases were young women who had a worsening of their visual acuity because of a serous retinal detachment. One woman had an optic disk pit maculopathy, and the other had a large optic disk with an atypical disk coloboma. After treatment with topical antiglaucoma medications, the subretinal fluid was resolved in both cases and the visual acuity was improved. Conclusion: The improvement of the maculopathy associated with cavitary optic disk anomalies was observed after the initiation of topical antiglaucoma eye drops. Although a spontaneous resolution cannot be excluded, these findings suggest that the decrease of intraocular pressure with antiglaucoma eye drops may be helpful in improving the retinopathy during the follow-up period in selective cases of cavitary optic disk anomalies.
- Open Access
- 10 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (18) , 2925
The Structure–Function Link of Ellipsoid Zone Integrity and Outer Retinal Features with Visual Acuity in Dry AMD
Background/Objectives: The purpose of this study was to evaluate associations between quantitative ellipsoid zone (EZ) integrity metrics derived from spectral-domain OCT (SD-OCT) and visual outcomes, including clinically meaningful visual acuity (VA) loss, in dry age-related macular degeneration (AMD). Methods: This single-center retrospective image-analysis cohort included 351 eyes from 351 patients with intermediate AMD or atrophic changes. Macular SD-OCT scans were analyzed using a certified-reader-validated machine learning-based segmentation platform to delineate the EZ, retinal pigment epithelium (RPE), and Bruch’s membrane (BM). EZ metrics included EZ-RPE thickness (i.e., outer segment thickness) and EZ attenuation, defined as partial attenuation (EZ-RPE thickness of ≤20 µm, abnormal outer segment thinning)) or total attenuation/loss (0 µm). Drusen volume was quantified from the RPE-BM compartment. VA was converted to ETDRS letters. Associations between baseline OCT metrics and baseline VA, Year 2 VA, and ≥15-letter VA loss were assessed using nonparametric testing, linear regression, and ANCOVA. Results: Greater EZ-RPE thickness and lower EZ attenuation were associated with better baseline VA (all p < 0.001), and EZ metrics remained significant in cross-sectional regression models. Among 188 eyes with Year 2 follow-up, 38 (20%) experienced ≥15-letter VA loss. These eyes had significantly lower baseline EZ-RPE thickness (i.e., abnormal outer segment thinning) and greater EZ attenuation than eyes without such loss (all p < 0.001). In ANCOVA models, EZ metrics remained associated with Year 2 VA (all p < 0.001), whereas drusen volume was not. Conclusions: Quantitative EZ integrity metrics were associated with cross-sectional and longitudinal visual outcomes in dry AMD. EZ-RPE thickness and EZ attenuation may serve as clinically relevant OCT biomarkers reflecting photoreceptor integrity and risk of meaningful VA loss.
- 10 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (18) , 2925
Open AccessThe Structure–Function Link of Ellipsoid Zone Integrity and Outer Retinal Features with Visual Acuity in Dry AMD
Background/Objectives: The purpose of this study was to evaluate associations between quantitative ellipsoid zone (EZ) integrity metrics derived from spectral-domain OCT (SD-OCT) and visual outcomes, including clinically meaningful visual acuity (VA) loss, in dry age-related macular degeneration (AMD). Methods: This single-center retrospective image-analysis cohort included 351 eyes from 351 patients with intermediate AMD or atrophic changes. Macular SD-OCT scans were analyzed using a certified-reader-validated machine learning-based segmentation platform to delineate the EZ, retinal pigment epithelium (RPE), and Bruch’s membrane (BM). EZ metrics included EZ-RPE thickness (i.e., outer segment thickness) and EZ attenuation, defined as partial attenuation (EZ-RPE thickness of ≤20 µm, abnormal outer segment thinning)) or total attenuation/loss (0 µm). Drusen volume was quantified from the RPE-BM compartment. VA was converted to ETDRS letters. Associations between baseline OCT metrics and baseline VA, Year 2 VA, and ≥15-letter VA loss were assessed using nonparametric testing, linear regression, and ANCOVA. Results: Greater EZ-RPE thickness and lower EZ attenuation were associated with better baseline VA (all p < 0.001), and EZ metrics remained significant in cross-sectional regression models. Among 188 eyes with Year 2 follow-up, 38 (20%) experienced ≥15-letter VA loss. These eyes had significantly lower baseline EZ-RPE thickness (i.e., abnormal outer segment thinning) and greater EZ attenuation than eyes without such loss (all p < 0.001). In ANCOVA models, EZ metrics remained associated with Year 2 VA (all p < 0.001), whereas drusen volume was not. Conclusions: Quantitative EZ integrity metrics were associated with cross-sectional and longitudinal visual outcomes in dry AMD. EZ-RPE thickness and EZ attenuation may serve as clinically relevant OCT biomarkers reflecting photoreceptor integrity and risk of meaningful VA loss.
- Open Access
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1394
The Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study
Objectives: to evaluate the feasibility and utility of intraoperative optical coherence tomography (iOCT) utilizing an immersive augmented reality surgical headset (Beyeonics iOCT, Beyeonics Vision Ltd., Haifa, Israel) digital visualization platform with swept-source integrated OCT in ophthalmic surgery. Methods: As part of the Institutional Review Board-approved prospective DISCOVER study, the Beyeonics iOCT was utilized in multiple ophthalmic surgical procedures to evaluate the feasibility and utility of iOCT with this platform. The Beyeonics iOCT is a three-dimensional surgical visualization system that utilizes a swept-source integrated OCT within the digital microscope system. Surgeon feedback on system performance and integration into the surgical workflow was gathered via a prespecified survey. Results: Thirteen eyes of thirteen patients were included in this study. The surgical procedures consisted of four cataract surgeries, two lamellar corneal transplants, one pterygium removal, and six vitreoretinal surgeries. Surgeons were able to successfully view and review the iOCT images within the surgical Head-Mounted Display, eliminating the need for an external display. Utility feedback from surgeons included iOCT assisting with confirming wound architecture, corneal graft orientation, and retinal structure. All surgeries were completed without reverting to a conventional microscope, and no intraoperative adverse events occurred. Conclusions: The new visualization platform with integrated swept-source iOCT demonstrated feasibility and potential utility in multiple ophthalmic surgical platforms. Additional research related to outcomes, ergonomics, and enhanced software analysis is needed in the future.
- 30 May 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (11) , 1394
Open AccessThe Feasibility and Clinical Evaluation of an Immersive Augmented Reality Surgical Headset Integrated with Swept-Source Intraoperative Optical Coherence Tomography for Ophthalmic Surgery in the DISCOVER Study
Objectives: to evaluate the feasibility and utility of intraoperative optical coherence tomography (iOCT) utilizing an immersive augmented reality surgical headset (Beyeonics iOCT, Beyeonics Vision Ltd., Haifa, Israel) digital visualization platform with swept-source integrated OCT in ophthalmic surgery. Methods: As part of the Institutional Review Board-approved prospective DISCOVER study, the Beyeonics iOCT was utilized in multiple ophthalmic surgical procedures to evaluate the feasibility and utility of iOCT with this platform. The Beyeonics iOCT is a three-dimensional surgical visualization system that utilizes a swept-source integrated OCT within the digital microscope system. Surgeon feedback on system performance and integration into the surgical workflow was gathered via a prespecified survey. Results: Thirteen eyes of thirteen patients were included in this study. The surgical procedures consisted of four cataract surgeries, two lamellar corneal transplants, one pterygium removal, and six vitreoretinal surgeries. Surgeons were able to successfully view and review the iOCT images within the surgical Head-Mounted Display, eliminating the need for an external display. Utility feedback from surgeons included iOCT assisting with confirming wound architecture, corneal graft orientation, and retinal structure. All surgeries were completed without reverting to a conventional microscope, and no intraoperative adverse events occurred. Conclusions: The new visualization platform with integrated swept-source iOCT demonstrated feasibility and potential utility in multiple ophthalmic surgical platforms. Additional research related to outcomes, ergonomics, and enhanced software analysis is needed in the future.
- 10 May 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (5) , 732-737
Factors predictive of treatment outcomes in submacular hemorrhage secondary to age-related macular degeneration
Purpose To identify predictors for visual outcomes of eyes with submacular hemorrhage (SMH) secondary to neovascular age-related macular degeneration (nAMD). Study Design Retrospective observational study. Methods Clinical data from patients diagnosed with SMH secondary to nAMD and treated with pneumatic displacement were collected. SMH thickness was measured by optical coherence tomography (OCT) at baseline and 1 week. Possible factors associated with best-corrected visual acuity (BCVA) gain at 3 months were analyzed. Results Fifty-six eyes of 56 patients (18 female/38 male; mean age, 77.8 ± 10.1 years) were analyzed; 34 were treatment-naïve and 22 were previously treated with anti-vascular endothelial growth factor agents. Multivariable analysis showed that greater BCVA gain more than 0.3 logMAR at 3 months post-treatment was associated with being treatment-naïve (odds ratio [OR], 34.30; 95% confidence interval [CI], 1.38–851.91; P = 0.031), thinner SMH thickness at 1 week after pneumatic displacement (OR, 0.38 per 50-unit increase; CI, 0.18–0.80; P = 0.011), and worse baseline BCVA (OR, 2.58 per 0.1-unit increase; CI, 1.31–5.07; P = 0.006), but not associated with age (OR, 0.50; 95% CI, 0.24–1.06), the time from onset to pneumatic displacement (OR, 1.04; 95%CI, 0.87–1.23), SMH thickness at baseline (OR, 0.92; 95%CI, 0.63–1.36), and the presence of subfoveal hemorrhagic PED (OR, 0.72; 95%CI, 0.08–6.84). Conclusion This study identifies novel factors predictive of visual outcomes for pneumatic displacement for SMH due to nAMD. The presence of residual SMH at 1 week following unsuccessful pneumatic displacement may warrant further intervention.
- 10 May 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (5) , 732-737
Factors predictive of treatment outcomes in submacular hemorrhage secondary to age-related macular degeneration
Purpose To identify predictors for visual outcomes of eyes with submacular hemorrhage (SMH) secondary to neovascular age-related macular degeneration (nAMD). Study Design Retrospective observational study. Methods Clinical data from patients diagnosed with SMH secondary to nAMD and treated with pneumatic displacement were collected. SMH thickness was measured by optical coherence tomography (OCT) at baseline and 1 week. Possible factors associated with best-corrected visual acuity (BCVA) gain at 3 months were analyzed. Results Fifty-six eyes of 56 patients (18 female/38 male; mean age, 77.8 ± 10.1 years) were analyzed; 34 were treatment-naïve and 22 were previously treated with anti-vascular endothelial growth factor agents. Multivariable analysis showed that greater BCVA gain more than 0.3 logMAR at 3 months post-treatment was associated with being treatment-naïve (odds ratio [OR], 34.30; 95% confidence interval [CI], 1.38–851.91; P = 0.031), thinner SMH thickness at 1 week after pneumatic displacement (OR, 0.38 per 50-unit increase; CI, 0.18–0.80; P = 0.011), and worse baseline BCVA (OR, 2.58 per 0.1-unit increase; CI, 1.31–5.07; P = 0.006), but not associated with age (OR, 0.50; 95% CI, 0.24–1.06), the time from onset to pneumatic displacement (OR, 1.04; 95%CI, 0.87–1.23), SMH thickness at baseline (OR, 0.92; 95%CI, 0.63–1.36), and the presence of subfoveal hemorrhagic PED (OR, 0.72; 95%CI, 0.08–6.84). Conclusion This study identifies novel factors predictive of visual outcomes for pneumatic displacement for SMH due to nAMD. The presence of residual SMH at 1 week following unsuccessful pneumatic displacement may warrant further intervention.
- 29 April 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (4) , 633-638
Clarity of surgical field displayed on 3D monitor with local dimming technology during heads-up surgery
Purpose To compare the clarity of images displayed on a 3D local dimming technology (LDT) monitor (LMD-XH550MT) to that on a conventional 3D monitor (LMD-X550MT) integrated into the Artevo 800® system. Study design Laboratory investigation Methods Six vitreoretinal surgeons evaluated the clarity of the surgical field on photographs displayed simultaneously on 2 monitors during cataract and vitreous surgery by the Artevo 800® system. The visibility scores were made on a 5-point scale for images recorded during anterior capsulotomy, phacoemulsification, cortex aspiration, core vitrectomy, and peeling an epiretinal membrane or an internal limiting membrane (ILM). The skewness and kurtosis of the images during anterior and posterior segment surgery were evaluated. Results The mean visibility scores were significantly higher with the LDT monitor at 4.7±0.1 than with the conventional monitor at 2.9±0.1 (P<0.001). The visibility scores for anterior capsulotomy (P=0.034), phacoemulsification (P=0.036), cortex aspiration (P=0.036), core vitrectomy (P=0.035), peeling of epiretinal membrane (P=0.036), and ILM (P=0.036) were significantly higher with the LDT monitor than with the conventional monitor. The absolute value of skewness during anterior segment surgery was significantly lower with the LDT monitor (0.20±0.05) than with the conventional monitor (-0.44±0.06, P=0.03). Conclusion Higher contrast with the LDT monitor was attained by adjusting the backlight brightness according to the brightness of the images, which provided better image clarity for 3D heads-up cataract and vitreous surgery.
- 29 April 2025
- Published by Springer Nature in Japanese Journal of Ophthalmology
- Vol. 69 (4) , 633-638
Clarity of surgical field displayed on 3D monitor with local dimming technology during heads-up surgery
Purpose To compare the clarity of images displayed on a 3D local dimming technology (LDT) monitor (LMD-XH550MT) to that on a conventional 3D monitor (LMD-X550MT) integrated into the Artevo 800® system. Study design Laboratory investigation Methods Six vitreoretinal surgeons evaluated the clarity of the surgical field on photographs displayed simultaneously on 2 monitors during cataract and vitreous surgery by the Artevo 800® system. The visibility scores were made on a 5-point scale for images recorded during anterior capsulotomy, phacoemulsification, cortex aspiration, core vitrectomy, and peeling an epiretinal membrane or an internal limiting membrane (ILM). The skewness and kurtosis of the images during anterior and posterior segment surgery were evaluated. Results The mean visibility scores were significantly higher with the LDT monitor at 4.7±0.1 than with the conventional monitor at 2.9±0.1 (P<0.001). The visibility scores for anterior capsulotomy (P=0.034), phacoemulsification (P=0.036), cortex aspiration (P=0.036), core vitrectomy (P=0.035), peeling of epiretinal membrane (P=0.036), and ILM (P=0.036) were significantly higher with the LDT monitor than with the conventional monitor. The absolute value of skewness during anterior segment surgery was significantly lower with the LDT monitor (0.20±0.05) than with the conventional monitor (-0.44±0.06, P=0.03). Conclusion Higher contrast with the LDT monitor was attained by adjusting the backlight brightness according to the brightness of the images, which provided better image clarity for 3D heads-up cataract and vitreous surgery.
- 1 March 2025
- Published by Wolters Kluwer Health in Retina
- Vol. 45 (3) , 478-485
FACTORS AFFECTING ASPIRATION VOLUMES OF BACK-FLUSH NEEDLES AND INFUSION VOLUMES OF VITRECTOMY DEVICE
Purpose: The stability of the eye is important during vitrectomy, which makes it important to balance the infusion rates (IRs) and the aspiration rates (ARs). The purpose of this study was to determine the effects of the IR from the vitrectomy device and the AR with back-flush needles. Methods: We compared the ARs of 25-gauge or 27-gauge back-flush needles manufactured by four companies. The AR of balanced salt solution (BSS), ethylene glycol mimicking subretinal fluid, and air was measured for each aspiration pressure. The IR of BSS and air was measured at different intraocular pressures. Results: The AR increased in proportion to the increase in the aspiration pressure, and it was positively correlated with the cross-sectional area of the soft tips and negatively with the total length of the soft tips. The IR of BSS and air increased in proportion to the increase in the intraocular pressures settings. The IR of BSS exceeded the AR of BSS and ethylene glycol for all parameters, but the IR of air could be less than the AR at some settings. Conclusion: The results suggest that the aspiration of air may cause a collapse of the eye under some settings.
- 1 March 2025
- Published by Wolters Kluwer Health in Retina
- Vol. 45 (3) , 478-485
FACTORS AFFECTING ASPIRATION VOLUMES OF BACK-FLUSH NEEDLES AND INFUSION VOLUMES OF VITRECTOMY DEVICE
Purpose: The stability of the eye is important during vitrectomy, which makes it important to balance the infusion rates (IRs) and the aspiration rates (ARs). The purpose of this study was to determine the effects of the IR from the vitrectomy device and the AR with back-flush needles. Methods: We compared the ARs of 25-gauge or 27-gauge back-flush needles manufactured by four companies. The AR of balanced salt solution (BSS), ethylene glycol mimicking subretinal fluid, and air was measured for each aspiration pressure. The IR of BSS and air was measured at different intraocular pressures. Results: The AR increased in proportion to the increase in the aspiration pressure, and it was positively correlated with the cross-sectional area of the soft tips and negatively with the total length of the soft tips. The IR of BSS and air increased in proportion to the increase in the intraocular pressures settings. The IR of BSS exceeded the AR of BSS and ethylene glycol for all parameters, but the IR of air could be less than the AR at some settings. Conclusion: The results suggest that the aspiration of air may cause a collapse of the eye under some settings.
- Open Access
- 20 October 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (20) , 6264
Association Between Arch-Shaped Hypo-Autofluorescent Lesions Detected Using Fundus Autofluorescence and Postoperative Hypotony
Background: Chorioretinal folds are observed after vitrectomy due to ocular collapse caused by low intraocular pressure. The purpose of this study is to investigate the relationship between the postoperative hypotony, chorioretinal folds, and the fundus autofluorescence (FAF) findings. Methods: Two-hundred-and-seventy consecutive eyes that had undergone 25- or 27-gauge vitrectomy were examined. The associations between the arch-shaped hypo-autofluorescent lesions in the FAF images and the postoperative hypotony with intraocular pressure (IOP) ≤ 4 mmHg were determined on the day after the surgery. Results: Arch-shaped hypo-autofluorescent lesions were seen in 4 of the 270 eyes (1.5%), and hypo-autofluorescence was observed in 3 of 14 hypotonic eyes (18.5%). This was significantly more frequent than in the non-hypotony group (0.4%, p = 0.0004). Optical coherence tomography showed a loss of the ellipsoid zone and retinal pigment epithelial layer in the region of the arch-shaped lesions. None of the arch-shaped hypo-autofluorescent lesions involved the fovea, and the vision recovered in all cases. The hypo-autofluorescent lesions did not disappear during the 4 to 16 month observation period. Conclusions: The postoperative arch-shaped hypo-autofluorescent lesions were associated with postoperative hypotony and RPE damage due to chorioretinal folds. These findings remained even when the IOP was normalized and chorioretinal folds disappeared.
- 20 October 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (20) , 6264
Open AccessAssociation Between Arch-Shaped Hypo-Autofluorescent Lesions Detected Using Fundus Autofluorescence and Postoperative Hypotony
Background: Chorioretinal folds are observed after vitrectomy due to ocular collapse caused by low intraocular pressure. The purpose of this study is to investigate the relationship between the postoperative hypotony, chorioretinal folds, and the fundus autofluorescence (FAF) findings. Methods: Two-hundred-and-seventy consecutive eyes that had undergone 25- or 27-gauge vitrectomy were examined. The associations between the arch-shaped hypo-autofluorescent lesions in the FAF images and the postoperative hypotony with intraocular pressure (IOP) ≤ 4 mmHg were determined on the day after the surgery. Results: Arch-shaped hypo-autofluorescent lesions were seen in 4 of the 270 eyes (1.5%), and hypo-autofluorescence was observed in 3 of 14 hypotonic eyes (18.5%). This was significantly more frequent than in the non-hypotony group (0.4%, p = 0.0004). Optical coherence tomography showed a loss of the ellipsoid zone and retinal pigment epithelial layer in the region of the arch-shaped lesions. None of the arch-shaped hypo-autofluorescent lesions involved the fovea, and the vision recovered in all cases. The hypo-autofluorescent lesions did not disappear during the 4 to 16 month observation period. Conclusions: The postoperative arch-shaped hypo-autofluorescent lesions were associated with postoperative hypotony and RPE damage due to chorioretinal folds. These findings remained even when the IOP was normalized and chorioretinal folds disappeared.
- 31 July 2023
- Published by Springer Nature in Eye
- Vol. 38 (2) , 266-273
Optical coherence tomographic findings of glaucomatous eyes with papillomacular retinoschisis
Objectives To investigate the relationship between the shape of the optic nerve head (ONH) margin detected by optical coherence tomography (OCT) and the clinical characteristics of glaucomatous eyes with papillomacular retinoschisis (PMRS). Methods The medical record of patients with a PMRS in a glaucomatous eye were reviewed. The eyes were placed into two groups determined by the shape of the ONH margin in the OCT images; eyes with an externally oblique ONH margin (Group 1) and eyes with an internally oblique ONH margin (Group 2). We compared the clinical characteristics of the PMRS of these two groups. Results We studied 31 eyes of 29 patients with PMRS and glaucoma with 24 eyes in Group 1 and 7 eyes in Group 2. The optic nerve fibre layer schisis on the lamina cribrosa (LC), beta zone, and gamma zone, and found that the LC defects were detected significantly more frequently in Group 1 than in Group 2 eyes (P < 0.05). A retinal nerve fibre schisis was observed around the ONH significantly more frequently in Group 2 than in Group 1 eyes (P < 0.01). Conclusion The cases of glaucoma-associated PMRS could be classified into two groups according to the obliquity of the ONH. They had differences in the findings of OCT and FA. The possibility that the mechanism of PMRS development is different in both groups is suggested.
- 31 July 2023
- Published by Springer Nature in Eye
- Vol. 38 (2) , 266-273
Optical coherence tomographic findings of glaucomatous eyes with papillomacular retinoschisis
Objectives To investigate the relationship between the shape of the optic nerve head (ONH) margin detected by optical coherence tomography (OCT) and the clinical characteristics of glaucomatous eyes with papillomacular retinoschisis (PMRS). Methods The medical record of patients with a PMRS in a glaucomatous eye were reviewed. The eyes were placed into two groups determined by the shape of the ONH margin in the OCT images; eyes with an externally oblique ONH margin (Group 1) and eyes with an internally oblique ONH margin (Group 2). We compared the clinical characteristics of the PMRS of these two groups. Results We studied 31 eyes of 29 patients with PMRS and glaucoma with 24 eyes in Group 1 and 7 eyes in Group 2. The optic nerve fibre layer schisis on the lamina cribrosa (LC), beta zone, and gamma zone, and found that the LC defects were detected significantly more frequently in Group 1 than in Group 2 eyes (P < 0.05). A retinal nerve fibre schisis was observed around the ONH significantly more frequently in Group 2 than in Group 1 eyes (P < 0.01). Conclusion The cases of glaucoma-associated PMRS could be classified into two groups according to the obliquity of the ONH. They had differences in the findings of OCT and FA. The possibility that the mechanism of PMRS development is different in both groups is suggested.
- Open Access
- 30 March 2023
- Published by Springer Nature in International Journal of Retina and Vitreous
- Vol. 9 (1) , 1-7
Image sharpening algorithms improve clarity of surgical field during 3D heads-up surgery
Background: Image-sharpening algorithms with color adjustments enable real-time processing of the surgical field with a delay of 4 msec for heads-up surgery using digital three-dimensional displays. The aim of this study was to investigate the usefulness of the algorithms with the Artevo 800® digital microscope. Methods: Seven vitreoretinal surgeons evaluated the effects of image-sharpening processing on the clarity of the surgical field with the Artevo 800® system that is used for cataract and vitreous surgeries. The scorings were made on a 10-point scale for anterior capsulotomy, phacoemulsification, cortex aspiration, core vitrectomy, and peeling of an epiretinal membrane or an internal limiting membrane. In addition, the images during the internal limiting membrane peeling were processed with or without color adjustments. We also evaluated the skewness (asymmetry in the distribution of the pixels) and kurtosis (sharpness in the distribution of the pixel) of the images to evaluate the contrast with each intensity of image-sharpening. Results: Our results showed that the mean visibility score increased significantly from 4.9 ± 0.5 at 0% (original image) to 6.6 ± 0.5 at 25% intensity of the image-sharpening algorithm (P < 0.01). The visibility scores of the internal limiting membrane increased significantly from 0% (6.8 ± 0.3, no color adjustments) to 50% after the color adjustments (7.4 ± 0.4, P = 0.012). The mean skewness decreased significantly from 0.83 ± 2.02 at 0% (original source) to 0.55 ± 1.36 at 25% intensity of the image-sharpening algorithm (P = 0.01). The mean kurtosis decreased significantly from 0.93 ± 2.14 at 0% (original image) to 0.60 ± 1.44 at 25% intensity of the image-sharpening algorithm (P = 0.02). Conclusions: We conclude that the image-sharpening algorithms can improve the clarity of the surgical field during 3D heads-up surgery by decreasing the skewness and kurtosis. Trial registration: This was a prospective clinical study performed at a single academic institution, and the procedures used were approved by the Institutional Review Committee of the Kyorin University School of Medicine (reference number, 1904). The procedures also conformed to the tenets of the Declaration of Helsinki.
- 30 March 2023
- Published by Springer Nature in International Journal of Retina and Vitreous
- Vol. 9 (1) , 1-7
Open AccessImage sharpening algorithms improve clarity of surgical field during 3D heads-up surgery
Background: Image-sharpening algorithms with color adjustments enable real-time processing of the surgical field with a delay of 4 msec for heads-up surgery using digital three-dimensional displays. The aim of this study was to investigate the usefulness of the algorithms with the Artevo 800® digital microscope. Methods: Seven vitreoretinal surgeons evaluated the effects of image-sharpening processing on the clarity of the surgical field with the Artevo 800® system that is used for cataract and vitreous surgeries. The scorings were made on a 10-point scale for anterior capsulotomy, phacoemulsification, cortex aspiration, core vitrectomy, and peeling of an epiretinal membrane or an internal limiting membrane. In addition, the images during the internal limiting membrane peeling were processed with or without color adjustments. We also evaluated the skewness (asymmetry in the distribution of the pixels) and kurtosis (sharpness in the distribution of the pixel) of the images to evaluate the contrast with each intensity of image-sharpening. Results: Our results showed that the mean visibility score increased significantly from 4.9 ± 0.5 at 0% (original image) to 6.6 ± 0.5 at 25% intensity of the image-sharpening algorithm (P < 0.01). The visibility scores of the internal limiting membrane increased significantly from 0% (6.8 ± 0.3, no color adjustments) to 50% after the color adjustments (7.4 ± 0.4, P = 0.012). The mean skewness decreased significantly from 0.83 ± 2.02 at 0% (original source) to 0.55 ± 1.36 at 25% intensity of the image-sharpening algorithm (P = 0.01). The mean kurtosis decreased significantly from 0.93 ± 2.14 at 0% (original image) to 0.60 ± 1.44 at 25% intensity of the image-sharpening algorithm (P = 0.02). Conclusions: We conclude that the image-sharpening algorithms can improve the clarity of the surgical field during 3D heads-up surgery by decreasing the skewness and kurtosis. Trial registration: This was a prospective clinical study performed at a single academic institution, and the procedures used were approved by the Institutional Review Committee of the Kyorin University School of Medicine (reference number, 1904). The procedures also conformed to the tenets of the Declaration of Helsinki.
- Open Access
- 23 March 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-9
Characteristics of subretinal particles detected after pars plana vitrectomy for rhegmatogenous retinal detachment
Background: To determine the incidence and characteristics of the multiple subretinal particles (SRPs) present after pars plana vitrectomy (PPV) for rhegmatogenous retinal detachment (RRD). Methods: The medical records of 224 eyes of 224 patients that underwent PPV for RRD were reviewed. The presence of SRPs in the subretinal fluid blebs and the presence of subretinal deposits were determined by optical coherence tomography (OCT) and fundus autofluorescence (FAF). The characteristics of the FAF and infrared reflectance (IR) images of a scanning laser ophthalmoscope in eyes with SRPs (SRPs group) were compared to that of eyes without SRPs (control group). Results: SRPs were observed in 27 eyes (12%), and they were completely resolved in 20 eyes (74%) after 6 months. The incidence of macula-off RRD (85%) and preoperative precipitates (41%) were significantly higher in the SRPs group than that in the control group (64%, P = 0.046; 12%, P = 0.002). The axial length was significantly shorter in the SRPs group than that in the control group (25.04 ± 1.54 mm, 26.00 ± 1.78 mm, P = 0.012). The preoperative and postoperative best-corrected visual acuity were not significantly different between the two groups (P = 0.702, P = 0.337). The subretinal fluid bleb determined by OCT were hyperfluorescent in the FAF images in 24 eyes (89%), and the subretinal deposits were hypofluorescent with solid appearance by OCT other than fluid in 3 eyes (11%). The hypofluorescent subretinal deposits in the FAF images were bright in the IR images in 2 eyes. Conclusions: The SRPs consist of lipofuscin-related hyperfluorescent subretinal fluid and the subretinal deposits containing bright IR melanin particles of proliferating retinal pigment epithelial cells.
- 23 March 2023
- Published by Springer Nature in BMC Ophthalmology
- Vol. 23 (1) , 1-9
Open AccessCharacteristics of subretinal particles detected after pars plana vitrectomy for rhegmatogenous retinal detachment
Background: To determine the incidence and characteristics of the multiple subretinal particles (SRPs) present after pars plana vitrectomy (PPV) for rhegmatogenous retinal detachment (RRD). Methods: The medical records of 224 eyes of 224 patients that underwent PPV for RRD were reviewed. The presence of SRPs in the subretinal fluid blebs and the presence of subretinal deposits were determined by optical coherence tomography (OCT) and fundus autofluorescence (FAF). The characteristics of the FAF and infrared reflectance (IR) images of a scanning laser ophthalmoscope in eyes with SRPs (SRPs group) were compared to that of eyes without SRPs (control group). Results: SRPs were observed in 27 eyes (12%), and they were completely resolved in 20 eyes (74%) after 6 months. The incidence of macula-off RRD (85%) and preoperative precipitates (41%) were significantly higher in the SRPs group than that in the control group (64%, P = 0.046; 12%, P = 0.002). The axial length was significantly shorter in the SRPs group than that in the control group (25.04 ± 1.54 mm, 26.00 ± 1.78 mm, P = 0.012). The preoperative and postoperative best-corrected visual acuity were not significantly different between the two groups (P = 0.702, P = 0.337). The subretinal fluid bleb determined by OCT were hyperfluorescent in the FAF images in 24 eyes (89%), and the subretinal deposits were hypofluorescent with solid appearance by OCT other than fluid in 3 eyes (11%). The hypofluorescent subretinal deposits in the FAF images were bright in the IR images in 2 eyes. Conclusions: The SRPs consist of lipofuscin-related hyperfluorescent subretinal fluid and the subretinal deposits containing bright IR melanin particles of proliferating retinal pigment epithelial cells.