Ashwini Kanakapura Sriranga
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ashwini Kanakapura Sriranga has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Qian Lu
Centre for Future Transport and Cities, Coventry University, Coventry CV1 5FB, UK
3 shared publications - Stewart Birrell
Centre for Future Transport and Cities (CFTC), Coventry University, Coventry CV1 5FB, UK
3 shared publications Baptiste Vasey
University of Oxford
1 shared publicationLucia Osoro
Universite Libre de Bruxelles
1 shared publicationMateo Campos
University of Oxford
1 shared publication- Miguel Ángel Armengol de la Hoz
Data Science Lab, Progress and Health Public Foundation (FPS), Regional Ministry of Health and Consumer Affairs, Seville, Spain
1 shared publication
Latest Publications
- Open Access
- 10 August 2026
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 42 (1) , e70
A life-cycle approach to digital health technology assessment
The approach of Health Technology Assessment, which developed from the Evidence-Based Medicine movement of the 1990s, has proved its value in appraising the value of pharma products but presents methodological challenges when applied to medical devices and digital technologies, whose importance has increased enormously during the last 30 years. The concept of a single assessment, which can summarize relative effectiveness and cost-effectiveness, has been further challenged by the rapidly rising importance of software-driven devices, and latterly Artificial Intelligence. The need to adopt a broader evaluation approach based on product life cycles has been recognized by both regulators and HTA bodies, but practical frameworks for this have not yet been widely adopted. We describe a Life-Cycle–Based Evaluation (LCBE) approach to the assessment of Digital Health Technologies, developed as part of the ASSESS-DHT Horizon Europe 2020 project, EU project 101137347. The LCBE framework is currently being evaluated in pilot studies and aims to support early, proportionate, and continuous assessment and foster collaboration among developers, regulators, and HTA bodies to ensure timely, rigorous, and adaptive evaluations across the technology life cycle.
- 10 August 2026
- Published by Cambridge University Press (CUP) in International Journal of Technology Assessment in Health Care
- Vol. 42 (1) , e70
Open AccessA life-cycle approach to digital health technology assessment
The approach of Health Technology Assessment, which developed from the Evidence-Based Medicine movement of the 1990s, has proved its value in appraising the value of pharma products but presents methodological challenges when applied to medical devices and digital technologies, whose importance has increased enormously during the last 30 years. The concept of a single assessment, which can summarize relative effectiveness and cost-effectiveness, has been further challenged by the rapidly rising importance of software-driven devices, and latterly Artificial Intelligence. The need to adopt a broader evaluation approach based on product life cycles has been recognized by both regulators and HTA bodies, but practical frameworks for this have not yet been widely adopted. We describe a Life-Cycle–Based Evaluation (LCBE) approach to the assessment of Digital Health Technologies, developed as part of the ASSESS-DHT Horizon Europe 2020 project, EU project 101137347. The LCBE framework is currently being evaluated in pilot studies and aims to support early, proportionate, and continuous assessment and foster collaboration among developers, regulators, and HTA bodies to ensure timely, rigorous, and adaptive evaluations across the technology life cycle.
- Open Access
Enhancing Heart Rate Detection in Vehicular Settings Using FMCW Radar and SCR-Guided Signal Processing
This paper presents an optimised signal processing framework for contactless physiological monitoring using Frequency Modulated Continuous Wave (FMCW) radar within automotive environments. This research focuses on enhancing heart rate (HR) and heart rate variability (HRV) detection from radar signals by integrating radar placement optimisation and advanced phase-based processing techniques. Optimal radar placement was evaluated through Signal-to-Clutter Ratio (SCR) analysis, conducted with multiple human participants in both laboratory and dynamic driving simulator experimental conditions, to determine the optimal in-vehicle location for signal acquisition. An effective processing pipeline was developed, incorporating background subtraction, range bin selection, bandpass filtering, and phase unwrapping. These techniques facilitated the reliable extraction of inter-beat intervals and heartbeat peaks from the phase signal without the need for contact-based sensors. The framework was evaluated using a Walabot FMCW radar module against ground truth HR signals, demonstrating consistent and repeatable results under baseline and mild motion conditions. In subsequent work, this framework was extended with deep learning methods, where radar-derived HR and HRV were benchmarked against research-grade ECG and achieved over 90% accuracy, further reinforcing the robustness and reliability of the approach. Together, these findings confirm that carefully guided radar positioning and robust signal processing can enable accurate and practical in-cabin physiological monitoring, offering a scalable solution for integration in future intelligent vehicle and driver monitoring systems.
Open AccessEnhancing Heart Rate Detection in Vehicular Settings Using FMCW Radar and SCR-Guided Signal Processing
This paper presents an optimised signal processing framework for contactless physiological monitoring using Frequency Modulated Continuous Wave (FMCW) radar within automotive environments. This research focuses on enhancing heart rate (HR) and heart rate variability (HRV) detection from radar signals by integrating radar placement optimisation and advanced phase-based processing techniques. Optimal radar placement was evaluated through Signal-to-Clutter Ratio (SCR) analysis, conducted with multiple human participants in both laboratory and dynamic driving simulator experimental conditions, to determine the optimal in-vehicle location for signal acquisition. An effective processing pipeline was developed, incorporating background subtraction, range bin selection, bandpass filtering, and phase unwrapping. These techniques facilitated the reliable extraction of inter-beat intervals and heartbeat peaks from the phase signal without the need for contact-based sensors. The framework was evaluated using a Walabot FMCW radar module against ground truth HR signals, demonstrating consistent and repeatable results under baseline and mild motion conditions. In subsequent work, this framework was extended with deep learning methods, where radar-derived HR and HRV were benchmarked against research-grade ECG and achieved over 90% accuracy, further reinforcing the robustness and reliability of the approach. Together, these findings confirm that carefully guided radar positioning and robust signal processing can enable accurate and practical in-cabin physiological monitoring, offering a scalable solution for integration in future intelligent vehicle and driver monitoring systems.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 26 (7) , 9491-9499
A Deep Learning-Based Contactless Driver State Monitoring Radar System for In-Vehicle Physiological Applications
The recent advancements in vehicle automation -and associated shift from driving to non-driving activities -has increased the importance of in-vehicle driver monitoring that is safe, trustworthy and useable. Physiological measurement of driver monitoring (rather than just eye tracking) is a nascent approach gaining attention in the space of in-vehicle technologies; however, existing contact sensor-based approaches raise concerns regarding system usage, complexity and privacy. This paper presents research which developed a novel, contactless heartrate monitoring system for drivers using Frequency Modulated Continuous Wave (FMCW) short-range radars, which was validated in vehicular environments. A combination of signal processing and neural network methodologies, incorporating Long Short-Term Memory (LSTM), was adopted to mitigate the effects of body motion and other motion artifacts that cause noisy radar data. The neural network was trained on ground truth data collected in parallel using a medical-grade BIOPAC ECG system. Similarly, the results were validated and compared against this ground truth. The experimental results evidence that FMCW radars are a promising methodology for in-vehicular cardio physiological applications, displaying an overall accuracy of 93% in detecting drivers’ heartrate (HR) and inter-beat-interval (IBI). Additionally, there was no significant difference observed in the RMSE results for driving and non-driving conditions, evidencing that the methodology performed efficiently in both the conditions. This paper demonstrates the benefits of FMCW radars for contactless physiological driver monitoring applications within automotive domains, and beyond.
- 15 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Intelligent Transportation Systems
- Vol. 26 (7) , 9491-9499
A Deep Learning-Based Contactless Driver State Monitoring Radar System for In-Vehicle Physiological Applications
The recent advancements in vehicle automation -and associated shift from driving to non-driving activities -has increased the importance of in-vehicle driver monitoring that is safe, trustworthy and useable. Physiological measurement of driver monitoring (rather than just eye tracking) is a nascent approach gaining attention in the space of in-vehicle technologies; however, existing contact sensor-based approaches raise concerns regarding system usage, complexity and privacy. This paper presents research which developed a novel, contactless heartrate monitoring system for drivers using Frequency Modulated Continuous Wave (FMCW) short-range radars, which was validated in vehicular environments. A combination of signal processing and neural network methodologies, incorporating Long Short-Term Memory (LSTM), was adopted to mitigate the effects of body motion and other motion artifacts that cause noisy radar data. The neural network was trained on ground truth data collected in parallel using a medical-grade BIOPAC ECG system. Similarly, the results were validated and compared against this ground truth. The experimental results evidence that FMCW radars are a promising methodology for in-vehicular cardio physiological applications, displaying an overall accuracy of 93% in detecting drivers’ heartrate (HR) and inter-beat-interval (IBI). Additionally, there was no significant difference observed in the RMSE results for driving and non-driving conditions, evidencing that the methodology performed efficiently in both the conditions. This paper demonstrates the benefits of FMCW radars for contactless physiological driver monitoring applications within automotive domains, and beyond.
- Open Access
A Systematic Review of In-Vehicle Physiological Indices and Sensor Technology for Driver Mental Workload Monitoring
The concept of vehicle automation ceases to seem futuristic with the current advancement of the automotive industry. With the introduction of conditional automated vehicles, drivers are no longer expected to focus only on driving activities but are still required to stay alert to resume control. However, fluctuations in driving demands are known to alter the driver’s mental workload (MWL), which might affect the driver’s vehicle take-over capabilities. Driver mental workload can be specified as the driver’s capacity for information processing for task performance. This paper summarizes the literature that relates to analysing driver mental workload through various in-vehicle physiological sensors focusing on cardiovascular and respiratory measures. The review highlights the type of study, hardware, method of analysis, test variable, and results of studies that have used physiological indices for MWL analysis in the automotive context.
Open AccessA Systematic Review of In-Vehicle Physiological Indices and Sensor Technology for Driver Mental Workload Monitoring
The concept of vehicle automation ceases to seem futuristic with the current advancement of the automotive industry. With the introduction of conditional automated vehicles, drivers are no longer expected to focus only on driving activities but are still required to stay alert to resume control. However, fluctuations in driving demands are known to alter the driver’s mental workload (MWL), which might affect the driver’s vehicle take-over capabilities. Driver mental workload can be specified as the driver’s capacity for information processing for task performance. This paper summarizes the literature that relates to analysing driver mental workload through various in-vehicle physiological sensors focusing on cardiovascular and respiratory measures. The review highlights the type of study, hardware, method of analysis, test variable, and results of studies that have used physiological indices for MWL analysis in the automotive context.