Ahmad Basshofi Habieb
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmad Basshofi Habieb has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Gabriele Milani
Architecture, Built Environment, and Construction Engineering Department , Politecnico di Milano , Milan , Italy
3 shared publicationsDjoko Irawan
Institut Teknologi Sepuluh Nopember
2 shared publicationsNurmurat Kandymov
Department of Civil Engineering , Paragon International University , Phnom Penh , Cambodia
2 shared publications- Amien Widodo
Geophysics Department, Institut Teknologi Sepuluh Nopember, Surabaya 60111, Indonesia
1 shared publication Aniendhita Rizki Amalia
Institut Teknologi Sepuluh Nopember
1 shared publicationBudi Suswanto
Institut Teknologi Sepuluh Nopember
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
The Effects of Soil-structure Interaction on the Seismic Performance of a Base-isolated 13-Story RC Building Founded on Soft Soil
Base isolation (BI) is a proven technique for reducing seismic demands on buildings, enhancing resilience, and maintaining post-earthquake functionality with minimal repairs. However, its effectiveness on soft soil remains uncertain due to soil–structure interaction (SSI), which can alter the building’s fundamental period and compromise the benefits of BI. This issue is critical, as many densely populated, high-seismicity cities are located on soft soil. This study investigates a 13-story building equipped with a lead–rubber bearing (LRB) isolation system on soft soil using nonlinear time-history analysis (NLTHA) that explicitly incorporates SSI effects. The results show that the BI system significantly increased the fundamental period by approximately 114% and reduced base shear by up to 47%. In addition, inter-story drift and peak acceleration were reduced by up to 49% and 48%, respectively. On the other hand, SSI increased base shear by up to 52% in the fixed-base model and approximately 76% in the base-isolated model. SSI also increased peak acceleration by up to 14% and 13% in the fixed-base and base-isolated models, respectively, highlighting its adverse impact on structural performance. Nevertheless, the BI system remained effective in mitigating seismic demands even in the presence of SSI. These findings emphasize the importance of incorporating SSI in seismic analysis and support the applicability of BI systems for high-rise buildings on soft soil.
- 24 June 2026
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
Open AccessThe Effects of Soil-structure Interaction on the Seismic Performance of a Base-isolated 13-Story RC Building Founded on Soft Soil
Base isolation (BI) is a proven technique for reducing seismic demands on buildings, enhancing resilience, and maintaining post-earthquake functionality with minimal repairs. However, its effectiveness on soft soil remains uncertain due to soil–structure interaction (SSI), which can alter the building’s fundamental period and compromise the benefits of BI. This issue is critical, as many densely populated, high-seismicity cities are located on soft soil. This study investigates a 13-story building equipped with a lead–rubber bearing (LRB) isolation system on soft soil using nonlinear time-history analysis (NLTHA) that explicitly incorporates SSI effects. The results show that the BI system significantly increased the fundamental period by approximately 114% and reduced base shear by up to 47%. In addition, inter-story drift and peak acceleration were reduced by up to 49% and 48%, respectively. On the other hand, SSI increased base shear by up to 52% in the fixed-base model and approximately 76% in the base-isolated model. SSI also increased peak acceleration by up to 14% and 13% in the fixed-base and base-isolated models, respectively, highlighting its adverse impact on structural performance. Nevertheless, the BI system remained effective in mitigating seismic demands even in the presence of SSI. These findings emphasize the importance of incorporating SSI in seismic analysis and support the applicability of BI systems for high-rise buildings on soft soil.
- Open Access
- 1 September 2024
- Published by Ital Publication in Civil Engineering Journal
- Vol. 10 (9) , 2781-2803
Effectiveness of Different Configurations of Ferrocement Retrofitting for Seismic Protection of Confined Masonry: A Numerical Study
A ferrocement layer, which consists of a wire mesh and cement mortar, is a popular retrofitting method for existing structural elements, particularly wall or slab panels. This paper presents a study on the effectiveness of different configurations of ferrocement for seismic retrofitting of confined masonry through finite element analysis. The masonry panel was modeled using expanded brick-unit elements, where the element was expanded in size by as much as half of the mortar thickness, and an interacting zero-thickness interface was applied to mimic the elastic-plastic and damage behavior during tension, shear, and compression. The concrete damage plasticity (CDP) model was used to model the confining reinforced concrete frame and overlay mortar in the ferrocement layer, and the reinforcing bars and wire mesh were modeled using elastic-plastic behavior. In the present numerical study, nine models were subjected to cyclic and pushover shear test simulations, considering the effects of the number of ferrocement layers and the wire mesh orientation. The volumetric ratio of the wire mesh to the masonry (ρwm) ranged from 0.48% to 1.92%, whereas the ratio of the mortar overlay to the masonry (ρmo) varies from 10.42% to 41.66%. Based on the increase in the lateral strength, the model with the largest volume of the ferrocement layer exhibited the largest increase in strength. However, the most cost-effective retrofitting configuration was presented by model DS-1-45, in which a single layer of ferrocement was applied on both sides of the wall using 45° of wire mesh orientation. The DS-1-45 model provided a lateral strength increase of more than 6 times compared to the original unreinforced model. Doi: 10.28991/CEJ-2024-010-09-02 Full Text: PDF
- 1 September 2024
- Published by Ital Publication in Civil Engineering Journal
- Vol. 10 (9) , 2781-2803
Open AccessEffectiveness of Different Configurations of Ferrocement Retrofitting for Seismic Protection of Confined Masonry: A Numerical Study
A ferrocement layer, which consists of a wire mesh and cement mortar, is a popular retrofitting method for existing structural elements, particularly wall or slab panels. This paper presents a study on the effectiveness of different configurations of ferrocement for seismic retrofitting of confined masonry through finite element analysis. The masonry panel was modeled using expanded brick-unit elements, where the element was expanded in size by as much as half of the mortar thickness, and an interacting zero-thickness interface was applied to mimic the elastic-plastic and damage behavior during tension, shear, and compression. The concrete damage plasticity (CDP) model was used to model the confining reinforced concrete frame and overlay mortar in the ferrocement layer, and the reinforcing bars and wire mesh were modeled using elastic-plastic behavior. In the present numerical study, nine models were subjected to cyclic and pushover shear test simulations, considering the effects of the number of ferrocement layers and the wire mesh orientation. The volumetric ratio of the wire mesh to the masonry (ρwm) ranged from 0.48% to 1.92%, whereas the ratio of the mortar overlay to the masonry (ρmo) varies from 10.42% to 41.66%. Based on the increase in the lateral strength, the model with the largest volume of the ferrocement layer exhibited the largest increase in strength. However, the most cost-effective retrofitting configuration was presented by model DS-1-45, in which a single layer of ferrocement was applied on both sides of the wall using 45° of wire mesh orientation. The DS-1-45 model provided a lateral strength increase of more than 6 times compared to the original unreinforced model. Doi: 10.28991/CEJ-2024-010-09-02 Full Text: PDF
- Open Access
- 4 March 2024
- Published by Petra Christian University in Civil Engineering Dimension
- Vol. 26 (1) , 63-70
Experimental Study of Two-way Half Slab Precast Concrete using Rextangular Rigid Connection
A half-slab precast concrete (HSPC) system with precast bottom layers and in-situ cast top layers has been widely applied in various constructions. It generally behaves as a one-way slab due to the absence of positive-flexural reinforcements in the perpendicular direction to the precast component. However, in some cases, the HSPC was also applied in a two-way slab system. Consequently, a particular design and treatment in the connection between precast members was required, so that the bending moment in two orthogonal directions could be accommodated. In the present study, an innovative rectangular rigid connection (RRC) in a two-way HSPC system was investigated through an experimental test. It was found that the RRC-HSPC presented only a 9.13% reduction of the load at the crack, a 16.44% reduction of the ultimate load, and a 6.06% increase of the deflection at the crack when compared to the monolithic one.
- 4 March 2024
- Published by Petra Christian University in Civil Engineering Dimension
- Vol. 26 (1) , 63-70
Open AccessExperimental Study of Two-way Half Slab Precast Concrete using Rextangular Rigid Connection
A half-slab precast concrete (HSPC) system with precast bottom layers and in-situ cast top layers has been widely applied in various constructions. It generally behaves as a one-way slab due to the absence of positive-flexural reinforcements in the perpendicular direction to the precast component. However, in some cases, the HSPC was also applied in a two-way slab system. Consequently, a particular design and treatment in the connection between precast members was required, so that the bending moment in two orthogonal directions could be accommodated. In the present study, an innovative rectangular rigid connection (RRC) in a two-way HSPC system was investigated through an experimental test. It was found that the RRC-HSPC presented only a 9.13% reduction of the load at the crack, a 16.44% reduction of the ultimate load, and a 6.06% increase of the deflection at the crack when compared to the monolithic one.
- 18 January 2024
- Published by Springer Nature
- p. 549-554
Diagonal Shear Test on Indonesian Masonry Walls
- 18 January 2024
- Published by Springer Nature
- p. 549-554
Diagonal Shear Test on Indonesian Masonry Walls
- Open Access
Seismic Retrofitting of Indonesian Masonry Using Bamboo Strips: An Experimental Study
Unreinforced masonry (UM) is well known as a vulnerable structure against earthquakes. However, it remains a popular structural system for low-rise residential housing in many high-seismicity areas, particularly in developing regions due to its low cost and easy construction. In the present study, a retrofitting strategy using locally available material, bamboo strips, was proposed. In addition to its fast-growing rate, the tensile strength of bamboo is considered high, nearly comparable to its steel counterpart. A series of experimental tests were performed in this study, including the bamboo tensile test, the mortar flexural test, the diagonal compressive shear test on the masonry assemblages, and the in-plane pushover test on masonry wall specimens without and with bamboo reinforcement. The retrofitted specimens with different volumes of bamboo reinforcement were also considered. The results show that the application of bamboo reinforcement, at a proper volume, significantly increases the ultimate strength and the ductility of the masonry wall. Such results indicate that the brittle failure of UM structures can be avoided by means of bamboo retrofitting.
Open AccessSeismic Retrofitting of Indonesian Masonry Using Bamboo Strips: An Experimental Study
Unreinforced masonry (UM) is well known as a vulnerable structure against earthquakes. However, it remains a popular structural system for low-rise residential housing in many high-seismicity areas, particularly in developing regions due to its low cost and easy construction. In the present study, a retrofitting strategy using locally available material, bamboo strips, was proposed. In addition to its fast-growing rate, the tensile strength of bamboo is considered high, nearly comparable to its steel counterpart. A series of experimental tests were performed in this study, including the bamboo tensile test, the mortar flexural test, the diagonal compressive shear test on the masonry assemblages, and the in-plane pushover test on masonry wall specimens without and with bamboo reinforcement. The retrofitted specimens with different volumes of bamboo reinforcement were also considered. The results show that the application of bamboo reinforcement, at a proper volume, significantly increases the ultimate strength and the ductility of the masonry wall. Such results indicate that the brittle failure of UM structures can be avoided by means of bamboo retrofitting.
- Open Access
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2186 (1) , 100011
Relaxation test and numerical modeling of rubber for seismic base isolation
This paper presents a series of experimentations and numerical modeling to evaluate the damping of rubber for seismic isolation purposes. A cyclic shear test is considered as a standard procedure to evaluate the damping of rubber materials. However, there is another method to evaluate the viscous damping of rubber by means of relaxation test that requires only small dumb-bell specimens of rubber, using a uniaxial tensile test device. This method allows an efficient procedure in examining the mechanical characteristic of rubber for seismic isolation purposes. This paper evaluates such a procedure to characterize the mechanical properties of a low damping rubber. The result shows that the proposed procedure presents a good prediction of the mechanical properties of the rubber.
- 10 December 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2186 (1) , 100011
Open AccessRelaxation test and numerical modeling of rubber for seismic base isolation
This paper presents a series of experimentations and numerical modeling to evaluate the damping of rubber for seismic isolation purposes. A cyclic shear test is considered as a standard procedure to evaluate the damping of rubber materials. However, there is another method to evaluate the viscous damping of rubber by means of relaxation test that requires only small dumb-bell specimens of rubber, using a uniaxial tensile test device. This method allows an efficient procedure in examining the mechanical characteristic of rubber for seismic isolation purposes. This paper evaluates such a procedure to characterize the mechanical properties of a low damping rubber. The result shows that the proposed procedure presents a good prediction of the mechanical properties of the rubber.
- 10 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1978 (1) , 450006
FE modelling of fiber reinforced elastomeric isolators (FREI): Mesh verification and validation
Seismic isolation is an effective technical solution to reduce the vulnerability of new and existing structures. It can mitigate the negative impact of an earthquake by shifting the period of the structure in that range of the spectrum where the spectral acceleration is low. A well known and relatively cheap seismic isolation device is the so-called elastomeric isolator. The fabrication cost of such isolator can be reduced by the utilization of fiber lamina instead of steel. In this work, finite element (FE) modeling of fiber reinforced elastomeric isolators is discussed. In numerical modelling, the main characteristic of elastomeric materials is the hyperelasticity, which can be taken into account in the commercial FE code that was used in the present study (namely ABAQUS). In this paper, an interesting issue highlighted is the mesh verification on FE models of an elastomeric material embedded into a seismic isolator.
- 10 July 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1978 (1) , 450006
FE modelling of fiber reinforced elastomeric isolators (FREI): Mesh verification and validation
Seismic isolation is an effective technical solution to reduce the vulnerability of new and existing structures. It can mitigate the negative impact of an earthquake by shifting the period of the structure in that range of the spectrum where the spectral acceleration is low. A well known and relatively cheap seismic isolation device is the so-called elastomeric isolator. The fabrication cost of such isolator can be reduced by the utilization of fiber lamina instead of steel. In this work, finite element (FE) modeling of fiber reinforced elastomeric isolators is discussed. In numerical modelling, the main characteristic of elastomeric materials is the hyperelasticity, which can be taken into account in the commercial FE code that was used in the present study (namely ABAQUS). In this paper, an interesting issue highlighted is the mesh verification on FE models of an elastomeric material embedded into a seismic isolator.
- Open Access
- 29 December 2017
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 11 (1) , 1026-1035
Low Cost Frictional Seismic Base-Isolation of Residential New Masonry Buildings in Developing Countries: A Small Masonry House Case Study
Introduction: An advanced Finite Element model is presented to examine the performance of a low-cost friction based-isolation system in reducing the seismic vulnerability of low-class rural housings. This study, which is mainly numerical, adopts as benchmark an experimental investigation on a single story masonry system eventually isolated at the base and tested on a shaking table in India.Methods: Four friction isolation interfaces, namely, marble-marble, marble-high-density polyethylene, marble-rubber sheet, and marble-geosynthetic were involved. Those interfaces differ for the friction coefficient, which was experimentally obtained through the aforementioned research. The FE model adopted here is based on a macroscopic approach for masonry, which is assumed as an isotropic material exhibiting damage and softening. The Concrete damage plasticity (CDP) model, that is available in standard package of ABAQUS finite element software, is used to determine the non-linear behavior of the house under non-linear dynamic excitation.Results and Conclusion: The results of FE analyses show that the utilization of friction isolation systems could much decrease the acceleration response at roof level, with a very good agreement with the experimental data. It is also found that systems with marble-marble and marble-geosynthetic interfaces reduce the roof acceleration up to 50% comparing to the system without isolation. Another interesting result is that there was little damage appearing in systems with frictional isolation during numerical simulations. Meanwhile, a severe state of damage was clearly visible for the system without isolation.
- 29 December 2017
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 11 (1) , 1026-1035
Open AccessLow Cost Frictional Seismic Base-Isolation of Residential New Masonry Buildings in Developing Countries: A Small Masonry House Case Study
Introduction: An advanced Finite Element model is presented to examine the performance of a low-cost friction based-isolation system in reducing the seismic vulnerability of low-class rural housings. This study, which is mainly numerical, adopts as benchmark an experimental investigation on a single story masonry system eventually isolated at the base and tested on a shaking table in India.Methods: Four friction isolation interfaces, namely, marble-marble, marble-high-density polyethylene, marble-rubber sheet, and marble-geosynthetic were involved. Those interfaces differ for the friction coefficient, which was experimentally obtained through the aforementioned research. The FE model adopted here is based on a macroscopic approach for masonry, which is assumed as an isotropic material exhibiting damage and softening. The Concrete damage plasticity (CDP) model, that is available in standard package of ABAQUS finite element software, is used to determine the non-linear behavior of the house under non-linear dynamic excitation.Results and Conclusion: The results of FE analyses show that the utilization of friction isolation systems could much decrease the acceleration response at roof level, with a very good agreement with the experimental data. It is also found that systems with marble-marble and marble-geosynthetic interfaces reduce the roof acceleration up to 50% comparing to the system without isolation. Another interesting result is that there was little damage appearing in systems with frictional isolation during numerical simulations. Meanwhile, a severe state of damage was clearly visible for the system without isolation.