Yuji Ino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yuji Ino has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Hironori Yamamoto
Jichi Medical University, Tochigi Prefecture, Japan
11 shared publications - Masafumi Kitamura
Jichi Medical University, Tochigi, Japan
6 shared publications - Hisashi Fukuda
Department of Medicine, Division of Gastroenterology, Jichi Medical University, Shimotsuke, Japan
5 shared publications Takashi Ueno
Jichi Medical University, Tochigi, Japan
5 shared publications- Tomonori Yano
Jichi Medical University, Tochigi, Japan
5 shared publications Kosei Hashimoto
Jichi Medical University, Tochigi, Japan
4 shared publications
Latest Publications
- Open Access
- 24 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Selection of an appropriate dissection plane in duodenal endoscopic submucosal dissection
- 24 November 2026
- Published by Georg Thieme Verlag KG in Endoscopy
Open AccessSelection of an appropriate dissection plane in duodenal endoscopic submucosal dissection
- Open Access
- 3 July 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 04) , E924-E925
Intrachannel delivery of a drainage tube beyond the endoscope tip for continuous low-pressure saline perfusion during endoscopic submucosal dissection
- 3 July 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 04) , E924-E925
Open AccessIntrachannel delivery of a drainage tube beyond the endoscope tip for continuous low-pressure saline perfusion during endoscopic submucosal dissection
- Open Access
- 15 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (Suppl 2) , E694-E695
Why bubble-free electrosurgical settings with continuous low-pressure saline perfusion are particularly suitable for duodenal endoscopic submucosal dissection
- 15 June 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (Suppl 2) , E694-E695
Open AccessWhy bubble-free electrosurgical settings with continuous low-pressure saline perfusion are particularly suitable for duodenal endoscopic submucosal dissection
- Open Access
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E180-E181
A bubble-free strategy for saline-immersion endoscopic submucosal dissection: optimized electrosurgical settings and continuous low-pressure saline perfusion
Saline-immersion therapeutic endoscopy and the water pressure method have recently gained attention as novel approaches for endoscopic submucosal dissection (ESD [1] [2]). These techniques offer multiple advantages, including stable visualization of the submucosal layer, improved scope maneuverability, and controlled submucosal expansion by buoyancy and hydrostatic pressure. However, during saline-immersion ESD, visibility is often impaired by bubble formation resulting from vaporization and electrolysis during the use of high-frequency devices [3]. To overcome these issues, we developed continuous low-pressure saline perfusion (CLPSP; [Fig. 1] [4] [5]). CLPSP rapidly expels bubbles from the endoscopic field, maintaining a clear view even during active dissection. Nevertheless, when high-voltage modes such as swiftCOAG and forcedCOAG are applied, which are often applied during submucosal dissection to achieve hemostasis, the generation of bubbles remains pronounced because of spark-induced vaporization and electrolysis. Even with continuous saline perfusion, these bubbles can temporarily impair visibility. Based on these findings, we designed an optimized electrosurgical strategy for bubble-free ESD under saline immersion ([Fig. 2], [Fig. 3] and [Video 1]). All procedures were performed using a VIO3 electrosurgical generator (Erbe Elektromedizin, Tübingen, Germany). Submucosal dissection is performed using endoCUT I (effect 4, duration 1, and interval 2), whereas softCOAG (effect 6–10, QuickStart off) is used for pre-coagulation of larger vessels. Under saline immersion, unlike in air, softCOAG ensures stable current conduction and uniform coagulation, even with a needle-type knife ([Fig. 4]). SoftCOAG delivers a low-voltage continuous current without spark or bubble formation. In the event of bleeding, high-flow saline irrigation maintains visibility, and forcedCOAG achieves hemostasis while suppressing vaporization and spark formation. In addition, CLPSP using automatic water irrigation synchronized with the electrosurgical unit (EIP2; Erbe, Tübingen, Germany) is useful for this technique. This combination of optimized high-frequency settings with CLPSP enables bubble-free ESD under saline immersion, preventing inadvertent bleeding and allowing smooth, efficient, and safe dissection. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 03 February 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 8 January 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 01) , E180-E181
Open AccessA bubble-free strategy for saline-immersion endoscopic submucosal dissection: optimized electrosurgical settings and continuous low-pressure saline perfusion
Saline-immersion therapeutic endoscopy and the water pressure method have recently gained attention as novel approaches for endoscopic submucosal dissection (ESD [1] [2]). These techniques offer multiple advantages, including stable visualization of the submucosal layer, improved scope maneuverability, and controlled submucosal expansion by buoyancy and hydrostatic pressure. However, during saline-immersion ESD, visibility is often impaired by bubble formation resulting from vaporization and electrolysis during the use of high-frequency devices [3]. To overcome these issues, we developed continuous low-pressure saline perfusion (CLPSP; [Fig. 1] [4] [5]). CLPSP rapidly expels bubbles from the endoscopic field, maintaining a clear view even during active dissection. Nevertheless, when high-voltage modes such as swiftCOAG and forcedCOAG are applied, which are often applied during submucosal dissection to achieve hemostasis, the generation of bubbles remains pronounced because of spark-induced vaporization and electrolysis. Even with continuous saline perfusion, these bubbles can temporarily impair visibility. Based on these findings, we designed an optimized electrosurgical strategy for bubble-free ESD under saline immersion ([Fig. 2], [Fig. 3] and [Video 1]). All procedures were performed using a VIO3 electrosurgical generator (Erbe Elektromedizin, Tübingen, Germany). Submucosal dissection is performed using endoCUT I (effect 4, duration 1, and interval 2), whereas softCOAG (effect 6–10, QuickStart off) is used for pre-coagulation of larger vessels. Under saline immersion, unlike in air, softCOAG ensures stable current conduction and uniform coagulation, even with a needle-type knife ([Fig. 4]). SoftCOAG delivers a low-voltage continuous current without spark or bubble formation. In the event of bleeding, high-flow saline irrigation maintains visibility, and forcedCOAG achieves hemostasis while suppressing vaporization and spark formation. In addition, CLPSP using automatic water irrigation synchronized with the electrosurgical unit (EIP2; Erbe, Tübingen, Germany) is useful for this technique. This combination of optimized high-frequency settings with CLPSP enables bubble-free ESD under saline immersion, preventing inadvertent bleeding and allowing smooth, efficient, and safe dissection. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AD Article published online: 03 February 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 22 April 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (05) , 575
Reply to Liu & Li
Thank you for your interest and your insightful questions [1]. We perform ESD without gastric distension. The endoscopic view can be maintained through the transparent cap (ST hood) attached to the tip of the endoscope. In addition, submucosal dissection is performed in the submucosal space created by the pocket-creation method, which requires no luminal expansion. We try to keep the stomach collapsed during the procedure. In our method of continuous low-pressure saline perfusion, the flow rate of the waterjet pump is set to the lowest. By using a nasogastric tube placed in the stomach, all of the infused saline is drained. The gastric lumen can be maintained at low pressure with slow saline flow and constant drainage. This effectively minimizes the risk of vomiting or aspiration. In addition, we believe that the risk of aspiration pneumonia is reduced when the gastric lumen is collapsed because the patient is less distressed and the procedure can be performed with light sedation. We can confirm that the gastric lumen is maintained at low pressure by observing the collapsed lumen with an endoscope. In the event of arterial bleeding, we immediately use the transparent cap to compress the bleeding site to temporarily stop the bleeding and insert hemostatic forceps. If vision is lost in saline, we use gel immersion endoscopy [2]. Lastly, we believe the risks of hypernatremia and water intoxication are low because we use isotonic physiological saline and most of the infused saline is removed through the nasogastric tube. We have not observed any cases of aspiration, discontinuation due to uncontrolled bleeding, hypernatremia, and water intoxication in our experience of 44 cases to date. However, it is important to confirm the safety of the procedure as you suggest. We plan to provide a summary of case outcomes in a future report. Article published online: 22 April 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 22 April 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (05) , 575
Reply to Liu & Li
Thank you for your interest and your insightful questions [1]. We perform ESD without gastric distension. The endoscopic view can be maintained through the transparent cap (ST hood) attached to the tip of the endoscope. In addition, submucosal dissection is performed in the submucosal space created by the pocket-creation method, which requires no luminal expansion. We try to keep the stomach collapsed during the procedure. In our method of continuous low-pressure saline perfusion, the flow rate of the waterjet pump is set to the lowest. By using a nasogastric tube placed in the stomach, all of the infused saline is drained. The gastric lumen can be maintained at low pressure with slow saline flow and constant drainage. This effectively minimizes the risk of vomiting or aspiration. In addition, we believe that the risk of aspiration pneumonia is reduced when the gastric lumen is collapsed because the patient is less distressed and the procedure can be performed with light sedation. We can confirm that the gastric lumen is maintained at low pressure by observing the collapsed lumen with an endoscope. In the event of arterial bleeding, we immediately use the transparent cap to compress the bleeding site to temporarily stop the bleeding and insert hemostatic forceps. If vision is lost in saline, we use gel immersion endoscopy [2]. Lastly, we believe the risks of hypernatremia and water intoxication are low because we use isotonic physiological saline and most of the infused saline is removed through the nasogastric tube. We have not observed any cases of aspiration, discontinuation due to uncontrolled bleeding, hypernatremia, and water intoxication in our experience of 44 cases to date. However, it is important to confirm the safety of the procedure as you suggest. We plan to provide a summary of case outcomes in a future report. Article published online: 22 April 2025 © 2025. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 12 March 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (4) , 561-568
Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan
Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan
- 12 March 2025
- Published by The Korean Society of Gastrointestinal Endoscopy in Clinical Endoscopy
- Vol. 58 (4) , 561-568
Open AccessUtility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan
Utility of underwater endoscopic mucosal resection combined with a protruding anchor by saline injection for superficial non-ampullary duodenal tumors: a retrospective study in Japan
- Open Access
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E298-E299
A modified detachable snare closure for post-endoscopic submucosal dissection defects: the clip, loop, and clips technique
Endoscopic closure of mucosal defects following gastric endoscopic submucosal dissection (ESD) using an endoloop and endoclips has been shown to reduce post-ESD bleeding, particularly in patients receiving antithrombotic therapy [1]. Various endoloop closure methods have been proposed, but they often require specialized equipment, such as a dual-channel endoscope, limiting their applicability. The bead-assisted endoloop closure method (bead, loop, and clips [BLC]) introduced in 2022 [2] facilitated closure with a single-channel endoscope, but posed challenges relating to foreign body insertion. In 2024, Tamaru et al. described the “clip and pull” method, which employs endoclips for endoloop manipulation without additional devices [3]. Building on these approaches, we propose the clip, loop, and clips (CLC) closure method, combining simplicity and efficiency using standard endoscopic tools. The technique was used in a 78-year-old man undergoing ESD for a gastric lesion while on aspirin therapy. As shown in [Fig. 1], an endoclip (HX-610-090L; Olympus, Tokyo, Japan) was placed at the base of a disposable endoloop device (HX-400U-30; Olympus) and transported to the defect site using a re-openable clip (ROCC-F-26-195-C; MicroTech, Nanjing, China). The reopenable clip was placed on the anal side of the mucosal defect, and additional clips were placed circumferentially, anchoring the endoloop to the mucosal defect. The endoloop was subsequently tightened using biopsy forceps (Radial Jaw 4P; Boston Scientific, Boston, Massachusetts, USA) passed through its sheath, with the clip acting as an anchor, achieving complete closure ([Fig. 2]). The procedure is detailed in [Video 1]. Successful defect closure was confirmed by follow-up endoscopy the following day ([Fig. 3]). There were no adverse events, in particular no post-ESD bleeding. The CLC closure method represents a straightforward and effective approach, particularly for moderate-sized defects and high risk patients, that can be performed using standard endoscopic instruments. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 09 April 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- 14 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 57 (S 01) , E298-E299
Open AccessA modified detachable snare closure for post-endoscopic submucosal dissection defects: the clip, loop, and clips technique
Endoscopic closure of mucosal defects following gastric endoscopic submucosal dissection (ESD) using an endoloop and endoclips has been shown to reduce post-ESD bleeding, particularly in patients receiving antithrombotic therapy [1]. Various endoloop closure methods have been proposed, but they often require specialized equipment, such as a dual-channel endoscope, limiting their applicability. The bead-assisted endoloop closure method (bead, loop, and clips [BLC]) introduced in 2022 [2] facilitated closure with a single-channel endoscope, but posed challenges relating to foreign body insertion. In 2024, Tamaru et al. described the “clip and pull” method, which employs endoclips for endoloop manipulation without additional devices [3]. Building on these approaches, we propose the clip, loop, and clips (CLC) closure method, combining simplicity and efficiency using standard endoscopic tools. The technique was used in a 78-year-old man undergoing ESD for a gastric lesion while on aspirin therapy. As shown in [Fig. 1], an endoclip (HX-610-090L; Olympus, Tokyo, Japan) was placed at the base of a disposable endoloop device (HX-400U-30; Olympus) and transported to the defect site using a re-openable clip (ROCC-F-26-195-C; MicroTech, Nanjing, China). The reopenable clip was placed on the anal side of the mucosal defect, and additional clips were placed circumferentially, anchoring the endoloop to the mucosal defect. The endoloop was subsequently tightened using biopsy forceps (Radial Jaw 4P; Boston Scientific, Boston, Massachusetts, USA) passed through its sheath, with the clip acting as an anchor, achieving complete closure ([Fig. 2]). The procedure is detailed in [Video 1]. Successful defect closure was confirmed by follow-up endoscopy the following day ([Fig. 3]). There were no adverse events, in particular no post-ESD bleeding. The CLC closure method represents a straightforward and effective approach, particularly for moderate-sized defects and high risk patients, that can be performed using standard endoscopic instruments. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 09 April 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
- Open Access
- 7 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 13 (CP)
Reduction of greenhouse gas emissions using the endoscope with a light-emitting diode light source
Light-emitting diodes are being developed as a light source for an endoscope system instead of xenon lamps, contributing to improved diagnostic capability. This system also has the advantage of consuming less power than a conventional endoscope system using xenon lamps. Power consumption associated with endoscopy is an important factor in reducing greenhouse gas emissions. This study estimated the reduction in greenhouse gas emissions by using a light-emitting diode endoscope system. We calculated the power consumption and carbon dioxide emission reduction of the light-emitting diode endoscope system in comparison with a conventional endoscope system using a xenon light source. Calculations were based on actual data regarding operating time and the annual number of endoscopic procedures at Jichi Medical University Hospital. Estimates were also extended to a nationwide scale. If each type of endoscope system were used for all endoscopic procedures, the light-emitting diode endoscope system would reduce power consumption by 49% compared with the xenon endoscope system, resulting in a total power reduction of 838.7kWh, equivalent to 394.2 kg of carbon dioxide emissions. In Japan, the total power consumption would be reduced by 53%, corresponding to a total power reduction of 428,628.8 kWh, equivalent to 201,455.5 kg of carbon dioxide emissions. We estimated the effect of reducing carbon dioxide emissions using the light-emitting diode endoscope system. Wider adoption of the light-emitting diode endoscope system is expected to contribute to usefulness of endoscopic diagnosis and reduction in environmental impact.
- 7 January 2025
- Published by Georg Thieme Verlag KG in Endoscopy International Open
- Vol. 13 (CP)
Open AccessReduction of greenhouse gas emissions using the endoscope with a light-emitting diode light source
Light-emitting diodes are being developed as a light source for an endoscope system instead of xenon lamps, contributing to improved diagnostic capability. This system also has the advantage of consuming less power than a conventional endoscope system using xenon lamps. Power consumption associated with endoscopy is an important factor in reducing greenhouse gas emissions. This study estimated the reduction in greenhouse gas emissions by using a light-emitting diode endoscope system. We calculated the power consumption and carbon dioxide emission reduction of the light-emitting diode endoscope system in comparison with a conventional endoscope system using a xenon light source. Calculations were based on actual data regarding operating time and the annual number of endoscopic procedures at Jichi Medical University Hospital. Estimates were also extended to a nationwide scale. If each type of endoscope system were used for all endoscopic procedures, the light-emitting diode endoscope system would reduce power consumption by 49% compared with the xenon endoscope system, resulting in a total power reduction of 838.7kWh, equivalent to 394.2 kg of carbon dioxide emissions. In Japan, the total power consumption would be reduced by 53%, corresponding to a total power reduction of 428,628.8 kWh, equivalent to 201,455.5 kg of carbon dioxide emissions. We estimated the effect of reducing carbon dioxide emissions using the light-emitting diode endoscope system. Wider adoption of the light-emitting diode endoscope system is expected to contribute to usefulness of endoscopic diagnosis and reduction in environmental impact.
- Open Access
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E880-E881
Continuous low-pressure saline perfusion for gastric endoscopic submucosal dissection
A method for conducting endoscopic submucosal dissection (ESD) by employing saline infusions in place of carbon dioxide has been reported [1]. This method effectively enhances the endoscopic visual field and maintains optimal intragastric pressure [2] [3]. Nevertheless, several limitations are noteworthy. First, blood admixture from bleeding events can significantly compromise visibility. Addressing this issue necessitates removing the incision device to suction the contaminated physiological saline solution. Second, potential bubble formation may obstruct the visual field by getting into the tip attachment. Consequently, operators are required to intermittently activate the foot pump of the water jet to disperse these bubbles. To mitigate these problems, we employ continuous low-pressure saline perfusion. After inserting the nasogastric tube and securing it to the gastric wall with clips ([Fig. 1]), an assistant operates the pedal of the water jet pump to continuously irrigate the gastric cavity with low-pressure physiological saline solution ([Fig. 2]). The advantages of this technique are described in the following. Sustained irrigation of the interior of the tip attachment with positive pressure facilitates bubble expulsion, thereby ensuring uninterrupted clarity of the visual field ([Fig. 3], [Fig. 4], [Fig. 5]). Moreover, operators can allocate their attention to manipulating the high-frequency device pedal without needing to engage the foot pedal of the water jet ([Video 1]). Furthermore, the availability of physiological saline solution retrieval from the nasogastric tube underscores its potential to mitigate hypernatremia and water intoxication, thereby enhancing overall procedural safety [4]. Apart from the standard ESD equipment, the sole requisites for this approach are physiological saline solution and a gastric tube, rendering it remarkably cost-effective. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AZ Article published online: 18 October 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 9 January 2024
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 56 (S 01) , E880-E881
Open AccessContinuous low-pressure saline perfusion for gastric endoscopic submucosal dissection
A method for conducting endoscopic submucosal dissection (ESD) by employing saline infusions in place of carbon dioxide has been reported [1]. This method effectively enhances the endoscopic visual field and maintains optimal intragastric pressure [2] [3]. Nevertheless, several limitations are noteworthy. First, blood admixture from bleeding events can significantly compromise visibility. Addressing this issue necessitates removing the incision device to suction the contaminated physiological saline solution. Second, potential bubble formation may obstruct the visual field by getting into the tip attachment. Consequently, operators are required to intermittently activate the foot pump of the water jet to disperse these bubbles. To mitigate these problems, we employ continuous low-pressure saline perfusion. After inserting the nasogastric tube and securing it to the gastric wall with clips ([Fig. 1]), an assistant operates the pedal of the water jet pump to continuously irrigate the gastric cavity with low-pressure physiological saline solution ([Fig. 2]). The advantages of this technique are described in the following. Sustained irrigation of the interior of the tip attachment with positive pressure facilitates bubble expulsion, thereby ensuring uninterrupted clarity of the visual field ([Fig. 3], [Fig. 4], [Fig. 5]). Moreover, operators can allocate their attention to manipulating the high-frequency device pedal without needing to engage the foot pedal of the water jet ([Video 1]). Furthermore, the availability of physiological saline solution retrieval from the nasogastric tube underscores its potential to mitigate hypernatremia and water intoxication, thereby enhancing overall procedural safety [4]. Apart from the standard ESD equipment, the sole requisites for this approach are physiological saline solution and a gastric tube, rendering it remarkably cost-effective. Endoscopy_UCTN_Code_TTT_1AO_2AG_3AZ Article published online: 18 October 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
- 13 July 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 01) , E889-E891
A loop cutter is an ideal gripper for endoscopic removal of press-through-package sheets
A press-through package (PTP) sheet is sometimes accidentally swallowed [1]. PTP sheets have sharp edges ([Fig. 1]) and may cause mucosal damage and/or perforation to the gastrointestinal tract [2] [3]. Thus, ingested PTP sheets should be removed endoscopically as soon as possible. Several methods have been reported using hoods and covers to prevent mucosal damage during removal [4] [5]. However, a firm grip on the PTP sheet is necessary for successful removal. Grasping forceps or a snare are commonly used as grasping devices but can often fail because the PTP is slippery with saliva and the working space is insufficient for snaring. To address this, we used a Loop Cutter (FS-5L-1; Olympus, Tokyo, Japan), whose teeth can penetrate the PTP plastic sheet to secure a firm grip. The Loop Cutter’s strong grip allows the PTP to be easily removed. To evaluate the gripping force of various devices, we attached a PTP sheet to the tip of a spring scale ([Fig. 2]). The gripping force was measured until the PTP was detached from the grasping device. The mean gripping force of each thirty times was 498 g in Standard Fenestrated Biopsy Forceps (FB-25K-1, Olympus), 404 g in the Radial Jaw 4 Pediatric Biopsy Forceps (M00513440; Boston Scientific, Marlborough, Massachusetts, USA), 37 g in the Rat Tooth with Alligator Jaw Grasping Forceps (FG-47L-1; Olympus), and 1440 g in the Loop Cutter ([Fig. 3]). A 70-year-old woman presented to our hospital complaining of a sore throat after accidentally ingesting PTP sheets. A computed tomography (CT) scan showed the PTP location in the esophagus ([Fig. 4]). The second case was a 63-year-old man with dementia. PTP was found in the stomach along with a large amount of food residue. The PTP sheets were successfully and safely removed endoscopically in both cases by grasping the PTP sheet using a Loop Cutter ([Fig. 5], [Video 1]). Video 1 A Loop Cutter is an ideal gripper for endoscopic removal of press-through packages. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 13 July 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 13 July 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 01) , E889-E891
Open AccessA loop cutter is an ideal gripper for endoscopic removal of press-through-package sheets
A press-through package (PTP) sheet is sometimes accidentally swallowed [1]. PTP sheets have sharp edges ([Fig. 1]) and may cause mucosal damage and/or perforation to the gastrointestinal tract [2] [3]. Thus, ingested PTP sheets should be removed endoscopically as soon as possible. Several methods have been reported using hoods and covers to prevent mucosal damage during removal [4] [5]. However, a firm grip on the PTP sheet is necessary for successful removal. Grasping forceps or a snare are commonly used as grasping devices but can often fail because the PTP is slippery with saliva and the working space is insufficient for snaring. To address this, we used a Loop Cutter (FS-5L-1; Olympus, Tokyo, Japan), whose teeth can penetrate the PTP plastic sheet to secure a firm grip. The Loop Cutter’s strong grip allows the PTP to be easily removed. To evaluate the gripping force of various devices, we attached a PTP sheet to the tip of a spring scale ([Fig. 2]). The gripping force was measured until the PTP was detached from the grasping device. The mean gripping force of each thirty times was 498 g in Standard Fenestrated Biopsy Forceps (FB-25K-1, Olympus), 404 g in the Radial Jaw 4 Pediatric Biopsy Forceps (M00513440; Boston Scientific, Marlborough, Massachusetts, USA), 37 g in the Rat Tooth with Alligator Jaw Grasping Forceps (FG-47L-1; Olympus), and 1440 g in the Loop Cutter ([Fig. 3]). A 70-year-old woman presented to our hospital complaining of a sore throat after accidentally ingesting PTP sheets. A computed tomography (CT) scan showed the PTP location in the esophagus ([Fig. 4]). The second case was a 63-year-old man with dementia. PTP was found in the stomach along with a large amount of food residue. The PTP sheets were successfully and safely removed endoscopically in both cases by grasping the PTP sheet using a Loop Cutter ([Fig. 5], [Video 1]). Video 1 A Loop Cutter is an ideal gripper for endoscopic removal of press-through packages. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 13 July 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany