Lei Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lei Wang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Sinan Li
The University of Sydney
4 shared publications - Chaohou Liu
SolaX Power Network Technology (Zhejiang) Co., Ltd., Hangzhou 311500, China
2 shared publications - Jinghang Li
University of Sydney, Camperdown, NSW, Australia
2 shared publications - Yanlong Li
SolaX Power Network Technology (Zhejiang) Co., Ltd., Hangzhou 311500, China
2 shared publications - Zheng Chen
School of Mechanical and Electrical Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China
2 shared publications Hangyu Wang
University of Sydney, Camperdown, NSW, Australia
1 shared publication
Latest Publications
- Open Access
Two Perspectives, One Impedance: Unified dq- and Sequence-Domain Impedance Modeling and Weak-Grid Stability Analysis of Grid-Connected LCL Inverters with Complete Industrial Control Loops
Grid-connected inverters with LCL filters regulate the inverter-side current in industrial products. Their small-signal impedance becomes frequency-coupled because of the phase-locked loop (PLL), and the remaining industrial control functions—active damping, PCC voltage feedforward and the outer power loop—make the model more complex. This coupling complicates both the stability assessment in weak grids and the interpretation of the relation between the dq-frame and the sequence-domain representations. This paper develops a unified impedance modeling and sequence-domain transformation framework for such inverters. Instead of complex harmonic linearization, the small-signal dq-frame model is derived in complex-vector form, which reduces the 2 × 2 impedance matrix to scalar sequence impedances without solving coupled multi-frequency algebraic equations. Closed-form relations among the dq, the modified sequence and the coupled sequence impedances are established, and the frequency shift between the two frames is formulated explicitly for both f1 < fc and f1 > fc. The dq-to-sequence equivalence is then verified along two independent routes—one through the stationary alpha–beta frame and one through symmetrical components—and the two results agree. Frequency-domain simulations and measurements on a 215 kW, 690 V industrial product show that the stability margin contracts as the PLL bandwidth widens and that a lead compensator designed from the model restores stable operation in a weak grid.
Open AccessTwo Perspectives, One Impedance: Unified dq- and Sequence-Domain Impedance Modeling and Weak-Grid Stability Analysis of Grid-Connected LCL Inverters with Complete Industrial Control Loops
Grid-connected inverters with LCL filters regulate the inverter-side current in industrial products. Their small-signal impedance becomes frequency-coupled because of the phase-locked loop (PLL), and the remaining industrial control functions—active damping, PCC voltage feedforward and the outer power loop—make the model more complex. This coupling complicates both the stability assessment in weak grids and the interpretation of the relation between the dq-frame and the sequence-domain representations. This paper develops a unified impedance modeling and sequence-domain transformation framework for such inverters. Instead of complex harmonic linearization, the small-signal dq-frame model is derived in complex-vector form, which reduces the 2 × 2 impedance matrix to scalar sequence impedances without solving coupled multi-frequency algebraic equations. Closed-form relations among the dq, the modified sequence and the coupled sequence impedances are established, and the frequency shift between the two frames is formulated explicitly for both f1 < fc and f1 > fc. The dq-to-sequence equivalence is then verified along two independent routes—one through the stationary alpha–beta frame and one through symmetrical components—and the two results agree. Frequency-domain simulations and measurements on a 215 kW, 690 V industrial product show that the stability margin contracts as the PLL bandwidth widens and that a lead compensator designed from the model restores stable operation in a weak grid.
- Open Access
Online Measured Impedance-Assisted State-of-Charge Estimation for Lithium-Ion Batteries Under Low Excitation Conditions via Fractional-Order Modeling
Accurate online parameter identification and state-of-charge (SOC) estimation are essential for lithium-ion battery management systems. However, under constant or quasi-constant current operating conditions, the system excitation is inherently weak, leading to poor parameter identifiability when conventional model-based estimation methods are used. This issue is particularly critical in grid-connected battery energy storage systems, where current dynamics are limited. To address this problem, this paper proposes an online measured impedance-assisted SOC estimation framework that integrates online electrochemical impedance measurements with a fractional-order battery model and an extended Kalman filter. Online impedance data are utilized to update the model parameters in real time through a geometric-based fitting algorithm, thereby enhancing model adaptability under low excitation conditions. Experimental results obtained from lithium-ion cells with different aging states demonstrate that the proposed method enables stable and accurate online parameter identification and SOC estimation under the tested low-excitation conditions, where conventional time-domain approaches tend to degrade or diverge. Robustness under highly dynamic operating conditions remains to be further validated.
Open AccessOnline Measured Impedance-Assisted State-of-Charge Estimation for Lithium-Ion Batteries Under Low Excitation Conditions via Fractional-Order Modeling
Accurate online parameter identification and state-of-charge (SOC) estimation are essential for lithium-ion battery management systems. However, under constant or quasi-constant current operating conditions, the system excitation is inherently weak, leading to poor parameter identifiability when conventional model-based estimation methods are used. This issue is particularly critical in grid-connected battery energy storage systems, where current dynamics are limited. To address this problem, this paper proposes an online measured impedance-assisted SOC estimation framework that integrates online electrochemical impedance measurements with a fractional-order battery model and an extended Kalman filter. Online impedance data are utilized to update the model parameters in real time through a geometric-based fitting algorithm, thereby enhancing model adaptability under low excitation conditions. Experimental results obtained from lithium-ion cells with different aging states demonstrate that the proposed method enables stable and accurate online parameter identification and SOC estimation under the tested low-excitation conditions, where conventional time-domain approaches tend to degrade or diverge. Robustness under highly dynamic operating conditions remains to be further validated.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1087-1101
A Modulation Method for Decoupling Capacitance Reduction in Single-Stage Dual-Active-Bridge Microinverters
Conventional single-stage dual active bridge (DAB) microinverters typically have a bulky capacitor for decoupling double-line frequency power and a significant pulsation in the input current, leading to reduced power density and degraded maximum power point tracking (MPPT) performance. This article presents a new modulation method for single-stage DAB microinverters, allowing for substantial reductions in both the required decoupling capacitance and the input current ripple without hardware modifications. This is achieved by repurposing the inherent primary-side dc-blocking capacitor as an active decoupling capacitor. The operating principles of the proposed modulation scheme are comprehensively analyzed, and an automatic decoupling control system based on large-signal modelling is designed. A 500 W experimental prototype is built for validation. Experimental results demonstrate that the proposed modulation method reduces the decoupling capacitor volume by 75% and decreases the double-line frequency pulsation in the input current by 96%, thereby improving the circuit’s power density and MPPT accuracy.
- 1 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (1) , 1087-1101
A Modulation Method for Decoupling Capacitance Reduction in Single-Stage Dual-Active-Bridge Microinverters
Conventional single-stage dual active bridge (DAB) microinverters typically have a bulky capacitor for decoupling double-line frequency power and a significant pulsation in the input current, leading to reduced power density and degraded maximum power point tracking (MPPT) performance. This article presents a new modulation method for single-stage DAB microinverters, allowing for substantial reductions in both the required decoupling capacitance and the input current ripple without hardware modifications. This is achieved by repurposing the inherent primary-side dc-blocking capacitor as an active decoupling capacitor. The operating principles of the proposed modulation scheme are comprehensively analyzed, and an automatic decoupling control system based on large-signal modelling is designed. A 500 W experimental prototype is built for validation. Experimental results demonstrate that the proposed modulation method reduces the decoupling capacitor volume by 75% and decreases the double-line frequency pulsation in the input current by 96%, thereby improving the circuit’s power density and MPPT accuracy.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13568-13583
Real-Time Optimal Control of Dual-Bridge Series Resonant DC–AC Converters
Control plays a critical role in achieving efficient operation of dual-bridge series resonant dc–ac converters (DBSRC). However, realizing real-time, optimal, and robust control of DBSRC to maximize its efficiency is generally difficult, due to the complex interplay of control variables, efficiency, power demand, and voltage conversion ratio requirements. Here, we propose an optimal control strategy for DBSRC, suitable for real-time closed-loop controller implementation. The key to the strategy is the development of a closed-form analytical solution of the optimal control variables for maximum system efficiency and output power regulation. Detailed derivation of the optimal control solution is provided. The effectiveness of the proposed control strategy is validated on a 200-W DBSRC prototype. The results confirm that the proposed control strategy can achieve real-time and robust control performance, with over 2% efficiency improvement over the conventional single-phase-shift control strategy.
- 30 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13568-13583
Real-Time Optimal Control of Dual-Bridge Series Resonant DC–AC Converters
Control plays a critical role in achieving efficient operation of dual-bridge series resonant dc–ac converters (DBSRC). However, realizing real-time, optimal, and robust control of DBSRC to maximize its efficiency is generally difficult, due to the complex interplay of control variables, efficiency, power demand, and voltage conversion ratio requirements. Here, we propose an optimal control strategy for DBSRC, suitable for real-time closed-loop controller implementation. The key to the strategy is the development of a closed-form analytical solution of the optimal control variables for maximum system efficiency and output power regulation. Detailed derivation of the optimal control solution is provided. The effectiveness of the proposed control strategy is validated on a 200-W DBSRC prototype. The results confirm that the proposed control strategy can achieve real-time and robust control performance, with over 2% efficiency improvement over the conventional single-phase-shift control strategy.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5924-5941
Bridgeless Star Power Factor Correction Architecture
Two-stage bridgeless power factor correction (PFC) architecture is widely used in high-power ac/dc applications. However, the bridgeless PFC front-end of the two-stage architecture often encounters challenges, such as high switching losses in continuous conduction mode (CCM) or high conduction and magnetic losses in critical conduction mode and other soft-switching modes. These challenges limit the overall system's efficiency and power density. This article presents a patent-pending semi-single-stage bridgeless Star PFC architecture. It allows simultaneous soft switching and CCM operation of the front-end bridgeless PFC rectifier, resulting in high-efficiency and high-density ac/dc system design. Simultaneous soft switching and CCM operation of the front-end bridgeless PFC rectifier is made possible by smartly “borrowing” the inductor/transformer current from the second-stage dc/dc back-end to create zero-voltage switching (ZVS) conditions for all switches in the PFC front-end. The architecture maintains the operation of the second-stage dc/dc back-end, and enjoys similar control simplicity to that in conventional two-stage PFC architecture. The merits of the proposed architecture are validated through a 240-W GaN-based laboratory prototype, achieving a full-load efficiency of 96.1%. Additionally, it boasts an impressive power density of 50 W/in 3 uncased.
- 6 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5924-5941
Bridgeless Star Power Factor Correction Architecture
Two-stage bridgeless power factor correction (PFC) architecture is widely used in high-power ac/dc applications. However, the bridgeless PFC front-end of the two-stage architecture often encounters challenges, such as high switching losses in continuous conduction mode (CCM) or high conduction and magnetic losses in critical conduction mode and other soft-switching modes. These challenges limit the overall system's efficiency and power density. This article presents a patent-pending semi-single-stage bridgeless Star PFC architecture. It allows simultaneous soft switching and CCM operation of the front-end bridgeless PFC rectifier, resulting in high-efficiency and high-density ac/dc system design. Simultaneous soft switching and CCM operation of the front-end bridgeless PFC rectifier is made possible by smartly “borrowing” the inductor/transformer current from the second-stage dc/dc back-end to create zero-voltage switching (ZVS) conditions for all switches in the PFC front-end. The architecture maintains the operation of the second-stage dc/dc back-end, and enjoys similar control simplicity to that in conventional two-stage PFC architecture. The merits of the proposed architecture are validated through a 240-W GaN-based laboratory prototype, achieving a full-load efficiency of 96.1%. Additionally, it boasts an impressive power density of 50 W/in 3 uncased.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (5) , 6337-6350
Burst Mode Control of Active-Power-Decoupling Integrated Active Clamp Flyback PFC Rectifiers
To mitigate the bulky and heavy twice-line frequency power buffer in single-phase power-factor-correction (PFC) rectifiers while maintaining a lower cost, active-power-decoupling integrated active clamp flyback (iACF) PFC rectifier is recently proposed in the literature. The solution inherits all the benefits of conventional ACF converters such as low component count, leakage energy recycling, and soft-switching while being able to reduce the size of the power buffer in the system without hardware modifications. However, existing modulation and control strategies, based on continuous-conduction-mode (CCM), can only achieve a high efficiency at heavy load but not at light load. This article proposes a new modulation to improve the light-load efficiency of iACF PFC rectifiers. By combining CCM and burst mode of operation, this new modulation method can maintain all good features of CCM while effectively reducing the operating frequency, thus reducing the switching losses of the system at light load. This article, first, reviews the existing light-load modulation methods for ACF converters and limitations of applying these methods to iACF are highlighted. The detailed operating principles of the proposed modulation method are explained, and controller implementation that supports simultaneous full-load, medium load and ultralight load operation is developed. A 100-W laboratory iACF prototype is developed to verify the feasibility of the proposal, showcasing a 4-point average efficiency 91.9%, superior to the conventional two-stage solutions.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (5) , 6337-6350
Burst Mode Control of Active-Power-Decoupling Integrated Active Clamp Flyback PFC Rectifiers
To mitigate the bulky and heavy twice-line frequency power buffer in single-phase power-factor-correction (PFC) rectifiers while maintaining a lower cost, active-power-decoupling integrated active clamp flyback (iACF) PFC rectifier is recently proposed in the literature. The solution inherits all the benefits of conventional ACF converters such as low component count, leakage energy recycling, and soft-switching while being able to reduce the size of the power buffer in the system without hardware modifications. However, existing modulation and control strategies, based on continuous-conduction-mode (CCM), can only achieve a high efficiency at heavy load but not at light load. This article proposes a new modulation to improve the light-load efficiency of iACF PFC rectifiers. By combining CCM and burst mode of operation, this new modulation method can maintain all good features of CCM while effectively reducing the operating frequency, thus reducing the switching losses of the system at light load. This article, first, reviews the existing light-load modulation methods for ACF converters and limitations of applying these methods to iACF are highlighted. The detailed operating principles of the proposed modulation method are explained, and controller implementation that supports simultaneous full-load, medium load and ultralight load operation is developed. A 100-W laboratory iACF prototype is developed to verify the feasibility of the proposal, showcasing a 4-point average efficiency 91.9%, superior to the conventional two-stage solutions.