Lei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Chen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Fuyou Li
School of Chemistry and Chemical Engineering & Institute of Translational Medicine Shanghai Jiao Tong University Shanghai 200240 China
4 shared publications - Jiamiao Yin
Department of Chemistry Fudan University Shanghai 200433 China
4 shared publications - Yiwei Fan
Academy for Engineering and Technology Fudan University Shanghai 200433 China
4 shared publications - Yuetian Pei
Academy for Engineering and Technology Fudan University Shanghai 200433 China
4 shared publications Donghao Hu
School of Chemistry and Chemical Engineering & Institute of Translational Medicine Shanghai Jiao Tong University Shanghai 200240 China
3 shared publicationsKuangshi Sun
Department of Chemistry Fudan University Shanghai 200433 China
3 shared publications
Latest Publications
A Lifetime Nanosensor for In Vivo pH Quantitative Imaging and Monitoring
Non‐invasive, in vivo quantitative imaging for long‐term biomarker monitoring is crucial for elucidating disease mechanisms, advancing precision medicine, and transforming diagnostics and therapeutic strategies. However, developing chemical sensors for sustained in vivo quantitative monitoring despite sensor concentration fluctuations, excitation variability, and tissue interference remains a major challenge. Here, a long‐lifetime nanosensor based on a lanthanide‐dye nanocomposite is presented that overcomes these limitations, enabling precise quantitative in vivo pH monitoring. Benefiting from a 64‐fold reversible change in the dye's molar extinction coefficient, this nanosensor enables the dynamic tuning of reversible non‐radiative energy transfer (RNET) efficiency (6.42%–35.23%) and luminescence lifetime (265–383 µs). This nanosensor enables 4 h of monitoring of gastrointestinal pH dynamics in mice following proton pump inhibitor (PPI) administration, offering new insights into pharmacodynamic effects across different administration routes and dosages and inter‐individual variability in drug efficacy. Moreover, coordination with lanthanide nanocrystals induces a significant shift in the dye's pK a , highlighting the importance of nanomaterial interface engineering. This work establishes a versatile platform for in vivo diagnostics and therapeutic monitoring, marking a significant step forward in precision medicine.
A Lifetime Nanosensor for In Vivo pH Quantitative Imaging and Monitoring
Non‐invasive, in vivo quantitative imaging for long‐term biomarker monitoring is crucial for elucidating disease mechanisms, advancing precision medicine, and transforming diagnostics and therapeutic strategies. However, developing chemical sensors for sustained in vivo quantitative monitoring despite sensor concentration fluctuations, excitation variability, and tissue interference remains a major challenge. Here, a long‐lifetime nanosensor based on a lanthanide‐dye nanocomposite is presented that overcomes these limitations, enabling precise quantitative in vivo pH monitoring. Benefiting from a 64‐fold reversible change in the dye's molar extinction coefficient, this nanosensor enables the dynamic tuning of reversible non‐radiative energy transfer (RNET) efficiency (6.42%–35.23%) and luminescence lifetime (265–383 µs). This nanosensor enables 4 h of monitoring of gastrointestinal pH dynamics in mice following proton pump inhibitor (PPI) administration, offering new insights into pharmacodynamic effects across different administration routes and dosages and inter‐individual variability in drug efficacy. Moreover, coordination with lanthanide nanocrystals induces a significant shift in the dye's pK a , highlighting the importance of nanomaterial interface engineering. This work establishes a versatile platform for in vivo diagnostics and therapeutic monitoring, marking a significant step forward in precision medicine.
- 21 April 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (28) , e2503726
Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation
Thermal ablation is a common treatment option for early‐stage cancers, but the lack of real‐time temperature imaging feedback method increases the risk of incomplete or excessive ablation. Although ratiometric nanothermometer offers a rapid temperature imaging solution, accurate in vivo signal extraction remains challenging due to the autofluorescence and wavelength‐dependent tissue absorption and scattering. Herein, a time‐resolved ratiometric fluorescence nanothermometer composed of europium and iridium complex with identical working wavelength but distinguishing lifetimes is reported, whose well‐designed structures enable 450 nm excitation of both complexes with a high quantum yield (57.8%). Based on the nanothermometer, accurate signal extraction is realized in whole blood, beneath a 2 cm tissue phantom and a 5 mm pork slice through a time‐resolved ratiometric method. By leveraging the exceptional thermal sensitivity (6.9% K −1 ), high temperature resolution (0.02 K), and clinically relevant temperature range (30–96 °C) of the nanothermometer, a fluorescence temperature endoscopy system is further designed with a real‐time temperature imaging speed of 10 fps, which is applied to minimally invasive temperature monitoring during microwave ablation of liver tumors in rabbits, realizing precise ablation control through dynamic ablation power adjustment. The real‐time and accurate temperature imaging performance of the nanothermometer may offer a new perspective for intraoperative guidance.
- 21 April 2025
- Published by Wiley in Advanced Materials
- Vol. 37 (28) , e2503726
Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation
Thermal ablation is a common treatment option for early‐stage cancers, but the lack of real‐time temperature imaging feedback method increases the risk of incomplete or excessive ablation. Although ratiometric nanothermometer offers a rapid temperature imaging solution, accurate in vivo signal extraction remains challenging due to the autofluorescence and wavelength‐dependent tissue absorption and scattering. Herein, a time‐resolved ratiometric fluorescence nanothermometer composed of europium and iridium complex with identical working wavelength but distinguishing lifetimes is reported, whose well‐designed structures enable 450 nm excitation of both complexes with a high quantum yield (57.8%). Based on the nanothermometer, accurate signal extraction is realized in whole blood, beneath a 2 cm tissue phantom and a 5 mm pork slice through a time‐resolved ratiometric method. By leveraging the exceptional thermal sensitivity (6.9% K −1 ), high temperature resolution (0.02 K), and clinically relevant temperature range (30–96 °C) of the nanothermometer, a fluorescence temperature endoscopy system is further designed with a real‐time temperature imaging speed of 10 fps, which is applied to minimally invasive temperature monitoring during microwave ablation of liver tumors in rabbits, realizing precise ablation control through dynamic ablation power adjustment. The real‐time and accurate temperature imaging performance of the nanothermometer may offer a new perspective for intraoperative guidance.
- 9 August 2024
- Published by Elsevier in Molecular Catalysis
- Vol. 566, 114432
Transition metal-free visible light-mediated photocatalytic aerobic oxidative synthesis of N-heterocycles using molecular oxygen as an oxidant
- 9 August 2024
- Published by Elsevier in Molecular Catalysis
- Vol. 566, 114432
Transition metal-free visible light-mediated photocatalytic aerobic oxidative synthesis of N-heterocycles using molecular oxygen as an oxidant
- 15 February 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (13)
Ultra‐long Near‐infrared Repeatable Photochemical Afterglow Mediated by Reversible Storage of Singlet Oxygen for Information Encryption
Photochemical afterglow systems have drawn considerable attention in recent years due to their regulable photophysical properties and charming application potential. However, conventional photochemical afterglow suffered from its unrepeatability due to the consumption of energy cache units as afterglow photons are emitted. Here we report a novel strategy to realize repeatable photochemical afterglow (RPA) through the reversible storage of1O2by 2‐pyridones. Near‐infrared afterglow with a lifetime over 10 s is achieved, and its initial intensity shows no significant reduction over 50 excitation cycles. A detailed mechanism study was conducted and confirmed the RPA is realized through the singlet oxygen‐sensitized fluorescence emission. Furthermore, the generality of this strategy is demonstrated and tunable afterglow lifetimes and colors are achieved by rational design. The developed RPA is further applied for attacker‐misleading information encryption, presenting a repeatable‐readout.
- 15 February 2023
- Published by Wiley in Angewandte Chemie
- Vol. 135 (13)
Ultra‐long Near‐infrared Repeatable Photochemical Afterglow Mediated by Reversible Storage of Singlet Oxygen for Information Encryption
Photochemical afterglow systems have drawn considerable attention in recent years due to their regulable photophysical properties and charming application potential. However, conventional photochemical afterglow suffered from its unrepeatability due to the consumption of energy cache units as afterglow photons are emitted. Here we report a novel strategy to realize repeatable photochemical afterglow (RPA) through the reversible storage of1O2by 2‐pyridones. Near‐infrared afterglow with a lifetime over 10 s is achieved, and its initial intensity shows no significant reduction over 50 excitation cycles. A detailed mechanism study was conducted and confirmed the RPA is realized through the singlet oxygen‐sensitized fluorescence emission. Furthermore, the generality of this strategy is demonstrated and tunable afterglow lifetimes and colors are achieved by rational design. The developed RPA is further applied for attacker‐misleading information encryption, presenting a repeatable‐readout.
- 15 February 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (13) , e202218670
Ultra‐long Near‐infrared Repeatable Photochemical Afterglow Mediated by Reversible Storage of Singlet Oxygen for Information Encryption
Photochemical afterglow systems have drawn considerable attention in recent years due to their regulable photophysical properties and charming application potential. However, conventional photochemical afterglow suffered from its unrepeatability due to the consumption of energy cache units as afterglow photons are emitted. Here we report a novel strategy to realize repeatable photochemical afterglow (RPA) through the reversible storage of 1O2 by 2‐pyridones. Near‐infrared afterglow with a lifetime over 10 s is achieved, and its initial intensity shows no significant reduction over 50 excitation cycles. A detailed mechanism study was conducted and confirmed the RPA is realized through the singlet oxygen‐sensitized fluorescence emission. Furthermore, the generality of this strategy is demonstrated and tunable afterglow lifetimes and colors are achieved by rational design. The developed RPA is further applied for attacker‐misleading information encryption, presenting a repeatable‐readout.
- 15 February 2023
- Published by Wiley in Angewandte Chemie International Edition
- Vol. 62 (13) , e202218670
Ultra‐long Near‐infrared Repeatable Photochemical Afterglow Mediated by Reversible Storage of Singlet Oxygen for Information Encryption
Photochemical afterglow systems have drawn considerable attention in recent years due to their regulable photophysical properties and charming application potential. However, conventional photochemical afterglow suffered from its unrepeatability due to the consumption of energy cache units as afterglow photons are emitted. Here we report a novel strategy to realize repeatable photochemical afterglow (RPA) through the reversible storage of 1O2 by 2‐pyridones. Near‐infrared afterglow with a lifetime over 10 s is achieved, and its initial intensity shows no significant reduction over 50 excitation cycles. A detailed mechanism study was conducted and confirmed the RPA is realized through the singlet oxygen‐sensitized fluorescence emission. Furthermore, the generality of this strategy is demonstrated and tunable afterglow lifetimes and colors are achieved by rational design. The developed RPA is further applied for attacker‐misleading information encryption, presenting a repeatable‐readout.