B. Sullivan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
B. Sullivan has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Derek A. Mariscal
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
4 shared publications - Ghassan Zeraouli
Colorado State University 1 , Fort Collins, Colorado 80523, USA
4 shared publications J. J. Rocca
Colorado State University 3 , Fort Collins, Colorado 80523, USA
4 shared publications- Reed Hollinger
Electrical and Computer Engineering Department, Colorado State University 1 , Fort Collins, Colorado 80523
4 shared publications S. Wang
Colorado State University 3 , Fort Collins, Colorado 80523, USA
4 shared publications- B. Z. Djordjevic
Lawrence Livermore National Laboratory 2 , Livermore, California 94550
3 shared publications
Latest Publications
- Open Access
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Toward machine-learning-assisted PW-class high-repetition-rate experiments with solid targets
We present progress in utilizing a machine learning (ML) assisted optimization framework to study the trends in a parameter space defined by spectrally shaped, high-intensity, petawatt-class (8 J, 45 fs) laser pulses interacting with solid targets and give the first simulation-based overview of predicted trends. A neural network (NN) incorporating uncertainty quantification is trained to predict the number of hot electrons generated by the laser–target interaction as a function of pulse shaping parameters. The predictions of this NN serve as the basis function for a Bayesian optimization framework to navigate this space. For post-experimental evaluation, we compare two separate neural network (NN) models. One is based solely on data from experiments, and the other is trained only on ensemble particle-in-cell simulations. Reviewing the predicted and observed trends across the experiment-capable laser parameter search space, we find that both ML models predict a maximal increase in hot electron generation at a level of approximately 12%–18%; however, no statistically significant enhancement was observed in experiments. On direct comparison of the NN models, the average discrepancy is 8.5%, with a maximum of 30%. Since shot-to-shot fluctuations in experiments affect the observations, we evaluate the behavior of our optimization framework by performing virtual experiments that vary the number of repeated observations and the noise levels. Here, we discuss the implications of such a framework for future autonomous exploration platforms in high-repetition-rate experiments.
- 1 July 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (7)
Open AccessToward machine-learning-assisted PW-class high-repetition-rate experiments with solid targets
We present progress in utilizing a machine learning (ML) assisted optimization framework to study the trends in a parameter space defined by spectrally shaped, high-intensity, petawatt-class (8 J, 45 fs) laser pulses interacting with solid targets and give the first simulation-based overview of predicted trends. A neural network (NN) incorporating uncertainty quantification is trained to predict the number of hot electrons generated by the laser–target interaction as a function of pulse shaping parameters. The predictions of this NN serve as the basis function for a Bayesian optimization framework to navigate this space. For post-experimental evaluation, we compare two separate neural network (NN) models. One is based solely on data from experiments, and the other is trained only on ensemble particle-in-cell simulations. Reviewing the predicted and observed trends across the experiment-capable laser parameter search space, we find that both ML models predict a maximal increase in hot electron generation at a level of approximately 12%–18%; however, no statistically significant enhancement was observed in experiments. On direct comparison of the NN models, the average discrepancy is 8.5%, with a maximum of 30%. Since shot-to-shot fluctuations in experiments affect the observations, we evaluate the behavior of our optimization framework by performing virtual experiments that vary the number of repeated observations and the noise levels. Here, we discuss the implications of such a framework for future autonomous exploration platforms in high-repetition-rate experiments.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas
We demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 1018 W/cm2) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 1018 W/cm2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (1011 W/cm2) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.
- 1 April 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (4)
Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas
We demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 1018 W/cm2) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 1018 W/cm2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (1011 W/cm2) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Flexible tape-drive target system for secondary high-intensity laser-driven sources
We present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 1018 W cm−2) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 μm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ∼170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessFlexible tape-drive target system for secondary high-intensity laser-driven sources
We present the development of a flexible tape-drive target system to generate and control secondary high-intensity laser-plasma sources. Its adjustable design permits the generation of relativistic MeV particles and x rays at high-intensity (i.e., ≥1 × 1018 W cm−2) laser facilities, at high repetition rates (>1 Hz). The compact and robust structure shows good mechanical stability and a high target placement accuracy (<4 μm RMS). Its compact and flexible design allows for mounting in both the horizontal and vertical planes, which makes it practical for use in cluttered laser-plasma experimental setups. The design permits ∼170° of access on the laser-driver side and 120° of diagnostic access at the rear. A range of adapted apertures have been designed and tested to be easily implemented to the targetry system. The design and performance testing of the tape-drive system in the context of two experiments performed at the COMET laser facility at the Lawrence Livermore National Laboratory and at the Advanced Lasers and Extreme Photonics (ALEPH) facility at Colorado State University are discussed. Experimental data showing that the designed prototype is also able to both generate and focus high-intensity laser-driven protons at high repetition rates are also presented.
- Open Access
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023507
A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)
The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ∼3 to 75 MeV with Hz rate) mode to recover nine proton energy bins. We also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.
- 1 February 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (2) , 023507
Open AccessA flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)
The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ∼3 to 75 MeV with Hz rate) mode to recover nine proton energy bins. We also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.