Scott Howard Altern
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Scott Howard Altern has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Steven M. Cramer
Department of Chemical and Biological Engineering Rensselaer Polytechnic Institute Troy New York USA
6 shared publications Andrew J. Kocot
Department of Chemical and Biological Engineering Rensselaer Polytechnic Institute Troy New York USA
4 shared publications- Abraham M. Lenhoff
Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716, USA
2 shared publications Chris Williams
Purification Development, Genentech, South San Francisco, CA, USA
2 shared publications- Jessica Yang Lyall
Purification Development, Genentech South San Francisco California USA
2 shared publications John P. Welsh
Biologics Process Research and Development, Merck & Co., Inc., Rahway, NJ, USA
2 shared publications
Latest Publications
- 22 January 2026
- Published by Wiley in Biotechnology Progress
- Vol. 42 (2) , e70102
Enhanced lentiviral vector recovery and separation using arginine hydrochloride with CIM QA monoliths
Lentiviral vectors (LVVs) offer distinct advantages including large payload capacity and stable transduction of non‐dividing cells, making them well‐suited for ex vivo modification of stem or immune cells. However, chromatographic purification of LVVs is hindered by low recoveries, co‐elution of product related impurities, and vector instability. In this study, we evaluated arginine hydrochloride (ArgHCl) as an alternative eluent to sodium chloride using CIMmultus™ QA (CIM QA) monoliths. Screening of solution conditions identified that phosphate buffer concentrations between 100–200 mM enhanced infective particle stability. During anion exchange screening experiments using a CIM QA 96‐well plate, ArgHCl improved both infectious particle and p24 recoveries, which was corroborated in linear gradient elution (LGE) experiments using the monolith in a disk format. Furthermore, fractions eluted with ArgHCl exhibited improved colloidal stability compared to those eluted with NaCl. Increasing the ArgHCl gradient endpoint concentration to 1.5 M ArgHCl yielded infectious particle recoveries of 71%. Analysis of gradient fractions with nanoflow cytometry revealed a two‐peak elution profile, with the more strongly retained peak enriched in vesicular stomatitis virus glycoprotein (VSV‐G) positive particles, corresponding to greater infectious particle recoveries. ArgHCl also improved the chromatographic resolution between the initial impurity peak and the secondary peak, enabling improved separation. These findings support the use of ArgHCl and phosphate buffers to enhance recovery during the purification of LVVs using AEX chromatography and highlight the utility of nanoflow cytometry for rapid detection of product‐related impurities.
- 22 January 2026
- Published by Wiley in Biotechnology Progress
- Vol. 42 (2) , e70102
Enhanced lentiviral vector recovery and separation using arginine hydrochloride with CIM QA monoliths
Lentiviral vectors (LVVs) offer distinct advantages including large payload capacity and stable transduction of non‐dividing cells, making them well‐suited for ex vivo modification of stem or immune cells. However, chromatographic purification of LVVs is hindered by low recoveries, co‐elution of product related impurities, and vector instability. In this study, we evaluated arginine hydrochloride (ArgHCl) as an alternative eluent to sodium chloride using CIMmultus™ QA (CIM QA) monoliths. Screening of solution conditions identified that phosphate buffer concentrations between 100–200 mM enhanced infective particle stability. During anion exchange screening experiments using a CIM QA 96‐well plate, ArgHCl improved both infectious particle and p24 recoveries, which was corroborated in linear gradient elution (LGE) experiments using the monolith in a disk format. Furthermore, fractions eluted with ArgHCl exhibited improved colloidal stability compared to those eluted with NaCl. Increasing the ArgHCl gradient endpoint concentration to 1.5 M ArgHCl yielded infectious particle recoveries of 71%. Analysis of gradient fractions with nanoflow cytometry revealed a two‐peak elution profile, with the more strongly retained peak enriched in vesicular stomatitis virus glycoprotein (VSV‐G) positive particles, corresponding to greater infectious particle recoveries. ArgHCl also improved the chromatographic resolution between the initial impurity peak and the secondary peak, enabling improved separation. These findings support the use of ArgHCl and phosphate buffers to enhance recovery during the purification of LVVs using AEX chromatography and highlight the utility of nanoflow cytometry for rapid detection of product‐related impurities.
- 8 February 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1745, 465723
Evaluation of prototype multimodal resins using chromatographic separability
- 8 February 2025
- Published by Elsevier in Journal of Chromatography A
- Vol. 1745, 465723
Evaluation of prototype multimodal resins using chromatographic separability
- 24 August 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1735, 465281
In silico mediated workflow for rapid development of downstream processing: Orthogonal product-related impurity removal for a Fc-containing therapeutic
- 24 August 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1735, 465281
In silico mediated workflow for rapid development of downstream processing: Orthogonal product-related impurity removal for a Fc-containing therapeutic
- 27 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1732, 465170
A batch screening technique for the calculation of chromatographic separability
- 27 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1732, 465170
A batch screening technique for the calculation of chromatographic separability
- 26 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1720, 464772
Mixed-mode size-exclusion silica resin for polishing human antibodies in flow-through mode
- 26 February 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1720, 464772
Mixed-mode size-exclusion silica resin for polishing human antibodies in flow-through mode
- 17 February 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1693, 463878
Isotherm model discrimination for multimodal chromatography using mechanistic models derived from high-throughput batch isotherm data
- 17 February 2023
- Published by Elsevier in Journal of Chromatography A
- Vol. 1693, 463878
Isotherm model discrimination for multimodal chromatography using mechanistic models derived from high-throughput batch isotherm data
- Open Access
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Isotherm Model Discrimination for Multimodal Chromatography Using Mechanistic Models Derived from High-Throughput Batch Isotherm Data: (II) Multimodal Anion-Exchange
While column modeling has been long studied for single-mode chromatographic systems, its application for multimodal systems has been limited. Although a range of isotherm formalisms have been applied to multimodal chromatography, no direct comparisons of their efficacies have been performed. This results in a lack of clarity with respect to which isotherm models should be employed and is a clear obstacle in modeling of multimodal chromatography. In this paper, a set of isotherm formalisms with ranging complexities, accounting for electrostatic interactions, hydrophobic interactions, and thermodynamic activities, were examined for their efficacy in fitting batch isotherm data as well as predicting column elution behavior. Batch isotherm data was generated for an array of salt conditions for Capto Adhere, a multimodal anion-exchange resin, using a mAb. Subsets of the batch data were then created, corresponding to the nonlinear region of the isotherm and the full range of protein loadings. Each set of batch data was fit twenty times with each isotherm formalism, which resulted in a distribution of isotherm parameter values. The models were next investigated for their accuracy in predicting changes in peak shape and protein recovery losses in linear salt gradients with respect to gradient slope. A scoring metric was then employed to evaluate the fitting and predictive efficacies for each isotherm formalism. In addition, the Akaike information criteria was used to aid in model selection by accounting for their predictive abilities and relative complexities. Sensitivity analyses were subsequently conducted to determine the contributions of individual isotherm parameters to the outputs of column predictions and batch data fits. A key finding of this investigation was the importance of the salt-protein activity coefficient parameter which dramatically affected the batch isotherm fits and column elution profiles. Parametric studies then demonstrated that this parameter single-handedly accounted for the impact of hydrophobic interactions in the multimodal system. Overall, this study resulted in the identification of a simplified isotherm model capable of accurately predicting complex column elution behavior.
- 1 January 2023
- Published by Elsevier in SSRN Electronic Journal
Open AccessIsotherm Model Discrimination for Multimodal Chromatography Using Mechanistic Models Derived from High-Throughput Batch Isotherm Data: (II) Multimodal Anion-Exchange
While column modeling has been long studied for single-mode chromatographic systems, its application for multimodal systems has been limited. Although a range of isotherm formalisms have been applied to multimodal chromatography, no direct comparisons of their efficacies have been performed. This results in a lack of clarity with respect to which isotherm models should be employed and is a clear obstacle in modeling of multimodal chromatography. In this paper, a set of isotherm formalisms with ranging complexities, accounting for electrostatic interactions, hydrophobic interactions, and thermodynamic activities, were examined for their efficacy in fitting batch isotherm data as well as predicting column elution behavior. Batch isotherm data was generated for an array of salt conditions for Capto Adhere, a multimodal anion-exchange resin, using a mAb. Subsets of the batch data were then created, corresponding to the nonlinear region of the isotherm and the full range of protein loadings. Each set of batch data was fit twenty times with each isotherm formalism, which resulted in a distribution of isotherm parameter values. The models were next investigated for their accuracy in predicting changes in peak shape and protein recovery losses in linear salt gradients with respect to gradient slope. A scoring metric was then employed to evaluate the fitting and predictive efficacies for each isotherm formalism. In addition, the Akaike information criteria was used to aid in model selection by accounting for their predictive abilities and relative complexities. Sensitivity analyses were subsequently conducted to determine the contributions of individual isotherm parameters to the outputs of column predictions and batch data fits. A key finding of this investigation was the importance of the salt-protein activity coefficient parameter which dramatically affected the batch isotherm fits and column elution profiles. Parametric studies then demonstrated that this parameter single-handedly accounted for the impact of hydrophobic interactions in the multimodal system. Overall, this study resulted in the identification of a simplified isotherm model capable of accurately predicting complex column elution behavior.