Jared Halstrom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jared Halstrom has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Clay Alexander Spitler
Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL; and
2 shared publications - Doriann M. Alcaide
Department of Orthopaedic Surgery, University of Missouri–Kansas City, Kansas City, USA
2 shared publications - Joseph P. Johnson
Department of Orthopaedic Surgery, University of Alabama at Birmingham, Birmingham, AL; and
2 shared publications - Aaron J. Casp
Department of Orthopaedic Surgery University of Alabama at Birmingham Birmingham Alabama U.S.A.
1 shared publication - Abhinav Agarwal
Department of Orthopaedic Surgery, University of Alabama at Birmingham; Birmingham, AL
1 shared publication - Amit Mukesh Momaya
Department of Orthopaedics University of Alabama at Birmingham Birmingham Alabama U.S.A.
1 shared publication
Latest Publications
- 11 September 2026
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
High-Velocity Changeups and Sweeper Usage Are Associated With Increased Odds of Undergoing Arthroscopic Shoulder Labral Repair in Professional Baseball Pitchers
Objective: The objective of this study was to determine whether pitch-specific characteristics, including velocity, spin rate, and pitch type usage, are predictive of arthroscopic shoulder labral repair (ASLR) in major league baseball (MLB) pitchers. Design: A retrospective analysis was conducted using MLB pitchers who underwent ASLR between 2016 and 2024. Pitch metrics were collected from Baseball Savant, a baseball sabermetric database, and compared with healthy league averages. Mann–Whitney U -tests and logistic regression were used to assess differences and predictors of ASLR. Setting: Major league baseball. Participants: Twenty-seven pitchers met the inclusion criteria by having Baseball Savant data from the season before undergoing ASLR. Interventions: None. Main Outcome Measures: Preinjury pitch metrics, including velocity, spin rate, movement profiles, and pitch usage. Results: Twenty-seven pitchers who underwent ASLR were compared with 6444 healthy league-average pitchers. Pitchers who threw changeups at higher velocities had increased odds of ASLR [ P = 0.0028; odds ratio (OR) = 1.263]. Greater use of low-velocity changeups ( P = 0.0279; OR = 0.942) and other off-speed pitches ( P = 0.0058; OR = 0.929) was associated with lower odds of undergoing ASLR, whereas higher sweeper usage ( P = 0.0194; OR = 1.071) was associated with increased odds. Conclusions: Major league baseball pitchers who threw higher-velocity changeups demonstrated increased odds of undergoing ASLR. In contrast, those who threw a higher proportion of lower-velocity changeups and other off-speed pitches, and fewer sweepers, showed decreased odds of labral repair.
- 11 September 2026
- Published by Wolters Kluwer Health in Clinical Journal of Sport Medicine
High-Velocity Changeups and Sweeper Usage Are Associated With Increased Odds of Undergoing Arthroscopic Shoulder Labral Repair in Professional Baseball Pitchers
Objective: The objective of this study was to determine whether pitch-specific characteristics, including velocity, spin rate, and pitch type usage, are predictive of arthroscopic shoulder labral repair (ASLR) in major league baseball (MLB) pitchers. Design: A retrospective analysis was conducted using MLB pitchers who underwent ASLR between 2016 and 2024. Pitch metrics were collected from Baseball Savant, a baseball sabermetric database, and compared with healthy league averages. Mann–Whitney U -tests and logistic regression were used to assess differences and predictors of ASLR. Setting: Major league baseball. Participants: Twenty-seven pitchers met the inclusion criteria by having Baseball Savant data from the season before undergoing ASLR. Interventions: None. Main Outcome Measures: Preinjury pitch metrics, including velocity, spin rate, movement profiles, and pitch usage. Results: Twenty-seven pitchers who underwent ASLR were compared with 6444 healthy league-average pitchers. Pitchers who threw changeups at higher velocities had increased odds of ASLR [ P = 0.0028; odds ratio (OR) = 1.263]. Greater use of low-velocity changeups ( P = 0.0279; OR = 0.942) and other off-speed pitches ( P = 0.0058; OR = 0.929) was associated with lower odds of undergoing ASLR, whereas higher sweeper usage ( P = 0.0194; OR = 1.071) was associated with increased odds. Conclusions: Major league baseball pitchers who threw higher-velocity changeups demonstrated increased odds of undergoing ASLR. In contrast, those who threw a higher proportion of lower-velocity changeups and other off-speed pitches, and fewer sweepers, showed decreased odds of labral repair.
- Open Access
- 1 February 2026
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 10 (2)
Outcomes of Periprosthetic Distal Femur Fractures by Fixation Construct: A Retrospective Cohort Study
Introduction: Periprosthetic distal femur fractures (PDFFs) are increasing with rising arthroplasty volumes. An optimal fixation strategy remains debated. This study evaluated outcomes of single lateral locking plate constructs (sLLPs), retrograde intramedullary nails (IMNs), and dual constructs (nail-plate or dual plating). Methods: A retrospective cohort study was done at a level I trauma center (2012 to 2024). Adults with PDFF (AO/Orthopaedic Trauma Association 33) treated with sLLP, IMN, or dual constructs were included. All patients were assessed for postoperative weight-bearing status, while clinical outcomes required ≥6-month follow-up or earlier documented complications. Outcomes included revision surgery, infection, implant failure, hardware removal, wound dehiscence, and time to weight bearing as tolerated (WBAT). Results: Of 99 identified patients, 64 met criteria (IMN: n = 20; sLLP: n = 19; dual: n = 25). Mean age was 69.0 years; 75.0% female, 59.4% Black; mean follow-up 391.5 days. Immediate WBAT was ore common in dual (70.7%) and IMN (52.8%) groups than sLLP (9.1%; P < 0.001). Mean time to WBAT was shortest with dual constructs (13.8 days), followed by IMN (26.0) and sLLP (42.8; P = 0.020). On multivariable analysis, sLLP fixation was associated with increased odds of unplanned revision surgery (OR 6.27, 95% confidence interval, 1.29 to 30.50, P = 0.023), while neither IMN ( P = 0.157) nor dual constructs ( P = 0.071) demonstrated a significant association. Conclusion: Single lateral locking plate fixation in PDFF was associated with higher odds of unplanned revision surgery. Dual construct patients had the shortest time to postoperative weight bearing and were more frequently permitted WBAT immediately after surgery.
- 1 February 2026
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 10 (2)
Open AccessOutcomes of Periprosthetic Distal Femur Fractures by Fixation Construct: A Retrospective Cohort Study
Introduction: Periprosthetic distal femur fractures (PDFFs) are increasing with rising arthroplasty volumes. An optimal fixation strategy remains debated. This study evaluated outcomes of single lateral locking plate constructs (sLLPs), retrograde intramedullary nails (IMNs), and dual constructs (nail-plate or dual plating). Methods: A retrospective cohort study was done at a level I trauma center (2012 to 2024). Adults with PDFF (AO/Orthopaedic Trauma Association 33) treated with sLLP, IMN, or dual constructs were included. All patients were assessed for postoperative weight-bearing status, while clinical outcomes required ≥6-month follow-up or earlier documented complications. Outcomes included revision surgery, infection, implant failure, hardware removal, wound dehiscence, and time to weight bearing as tolerated (WBAT). Results: Of 99 identified patients, 64 met criteria (IMN: n = 20; sLLP: n = 19; dual: n = 25). Mean age was 69.0 years; 75.0% female, 59.4% Black; mean follow-up 391.5 days. Immediate WBAT was ore common in dual (70.7%) and IMN (52.8%) groups than sLLP (9.1%; P < 0.001). Mean time to WBAT was shortest with dual constructs (13.8 days), followed by IMN (26.0) and sLLP (42.8; P = 0.020). On multivariable analysis, sLLP fixation was associated with increased odds of unplanned revision surgery (OR 6.27, 95% confidence interval, 1.29 to 30.50, P = 0.023), while neither IMN ( P = 0.157) nor dual constructs ( P = 0.071) demonstrated a significant association. Conclusion: Single lateral locking plate fixation in PDFF was associated with higher odds of unplanned revision surgery. Dual construct patients had the shortest time to postoperative weight bearing and were more frequently permitted WBAT immediately after surgery.
- Open Access
- 6 October 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Technical note: novel utilization of an H-plate for the treatment of posterior wall components of acetabular fractures
Posterior wall components of acetabular fractures are challenging injuries to treat due to the frequency of comminution, marginal impaction and high contact forces of the femoral head on the posterior wall. A variety of fixation techniques for these components have been utilized including conventional buttress plating and free screws. The objective of this report is to describe the technical application of the DePuy Synthes 2.7mm nonlocking hindfoot and midfoot plate, a 5-hole implant (the “H-plate”) (DePuy Synthes; Raynham, MA), in the surgical treatment of posterior wall fractures and to present early clinical outcomes from its use. We report a series of 95 patients who underwent fixation of posterior wall components of acetabular fractures (AO/OTA 62) with an H-plate construct. At a mean follow-up of 257 days, conversion to total hip arthroplasty occurred in six patients (6.3%), there were no postoperative dislocations, four surgical site infections (4.2%), and no cases required revision open reduction internal fixation. The H-plate’s overall shape may enhance stability due to its width and design, and these early results suggest that the H-plate may represent a viable option for stabilization of posterior wall fractures. Level of evidence: III.
- 6 October 2025
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 35 (1) , 1-8
Open AccessTechnical note: novel utilization of an H-plate for the treatment of posterior wall components of acetabular fractures
Posterior wall components of acetabular fractures are challenging injuries to treat due to the frequency of comminution, marginal impaction and high contact forces of the femoral head on the posterior wall. A variety of fixation techniques for these components have been utilized including conventional buttress plating and free screws. The objective of this report is to describe the technical application of the DePuy Synthes 2.7mm nonlocking hindfoot and midfoot plate, a 5-hole implant (the “H-plate”) (DePuy Synthes; Raynham, MA), in the surgical treatment of posterior wall fractures and to present early clinical outcomes from its use. We report a series of 95 patients who underwent fixation of posterior wall components of acetabular fractures (AO/OTA 62) with an H-plate construct. At a mean follow-up of 257 days, conversion to total hip arthroplasty occurred in six patients (6.3%), there were no postoperative dislocations, four surgical site infections (4.2%), and no cases required revision open reduction internal fixation. The H-plate’s overall shape may enhance stability due to its width and design, and these early results suggest that the H-plate may represent a viable option for stabilization of posterior wall fractures. Level of evidence: III.
- 17 February 2023
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 62 (4) , 683-688
First Metatarsophalangeal Arthrodesis for Hallux Rigidus and Hallux Valgus: A Comparison of Patient Reported and Clinical Outcomes
- 17 February 2023
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 62 (4) , 683-688
First Metatarsophalangeal Arthrodesis for Hallux Rigidus and Hallux Valgus: A Comparison of Patient Reported and Clinical Outcomes