Ala Addin Mohammed Al-Dwa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ala Addin Mohammed Al-Dwa has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ali Chebabhi
Electrical Engineering Laboratory, Faculty of Technology, University of Msila, Msila, Algeria
2 shared publications - Anwar Guessabi
LAS Laboratory, Faculty of Technology, Ferhat Abbas University Setif 1, Campus El Bez, 19137 Setif, Algeria
1 shared publication - Ayman Alhejji
Electrical Engineering Department, Yanbu Industrial College, Yanbu Industrial City 46452, Saudi Arabia
1 shared publication - Djamel Ziane
IREENA Laboratory, Nantes University, 44600 Saint Nazaire, France
1 shared publication - Habib Benbouhenni
Department of Electrical Engineering, Faculty of Technology, Hassiba Benbouali University of Chlef, B.P 78C Ouled Fares, Chlef 02180, Algeria
1 shared publication - Mabrouk Defdaf
Electrical Engineering Laboratory, Faculty of Technology, University of Msila, Msila, Algeria
1 shared publication
Latest Publications
- Open Access
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 101121-101138
Real-Time Implementation of a New Modified 3DSVPWM Control Method for Eliminating Zero-Sequence Circulating Current in Parallel Three-Phase Four-Leg Source Voltage Inverters
Due to its good reliability, high modularity, zero-sequence current (ZSC) path, and lower size and cost, the parallel four-leg source voltage inverter’s topology is a perfect choice for many power applications, including renewable power generation-based stand-alone power-supply systems (SAPSSs). However, the major concern associated with this topology is the presence of a zero-sequence circulating current (ZSCC) that circulates between the phase legs of these inverters when the inverters operate under unbalanced current sharing or unbalanced output-filter parameters, which leads to multiple consequences, including output current distortion, power losses, and system stability degradation, as well as impacting the efficiency, reliability, and operational lifespan of the system. The ZSCC model demonstrates that the ZSCC amplitude is linked to the filter inductance and difference between zero-sequence duty ratios or zero-sequence voltages (ZSVs). Considering these facts, we propose a new modified three-dimensional space vector pulse width modulation (3DSVPWM) methodology to suppress ZSCC and its effects on the current quality, efficiency, reliability, and operational lifespan of the parallel system. The suggested strategy aims to eliminate the difference between ZSVs by adjusting the zero-vector duty ratios in each switching period. This adjustment keeps the ZSCC constant at zero with minimal oscillations and switching losses, thereby improving the output current quality, particularly in mitigating the $3^{\mathrm {rd}}$ harmonic and its multiples, and enhancing the system’s efficiency, reliability, and operational lifespan. The proposed method offers the advantages of being suitable for suppressing both the ZSCC and ZSC and not impacting the control purposes or the system’s output quality. The efficiency and performance of the designed method are validated through various Hardware-in-the-loop (HIL) tests under different conditions using the OPAL-RT-OP5700 real-time simulator.
- 19 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 101121-101138
Open AccessReal-Time Implementation of a New Modified 3DSVPWM Control Method for Eliminating Zero-Sequence Circulating Current in Parallel Three-Phase Four-Leg Source Voltage Inverters
Due to its good reliability, high modularity, zero-sequence current (ZSC) path, and lower size and cost, the parallel four-leg source voltage inverter’s topology is a perfect choice for many power applications, including renewable power generation-based stand-alone power-supply systems (SAPSSs). However, the major concern associated with this topology is the presence of a zero-sequence circulating current (ZSCC) that circulates between the phase legs of these inverters when the inverters operate under unbalanced current sharing or unbalanced output-filter parameters, which leads to multiple consequences, including output current distortion, power losses, and system stability degradation, as well as impacting the efficiency, reliability, and operational lifespan of the system. The ZSCC model demonstrates that the ZSCC amplitude is linked to the filter inductance and difference between zero-sequence duty ratios or zero-sequence voltages (ZSVs). Considering these facts, we propose a new modified three-dimensional space vector pulse width modulation (3DSVPWM) methodology to suppress ZSCC and its effects on the current quality, efficiency, reliability, and operational lifespan of the parallel system. The suggested strategy aims to eliminate the difference between ZSVs by adjusting the zero-vector duty ratios in each switching period. This adjustment keeps the ZSCC constant at zero with minimal oscillations and switching losses, thereby improving the output current quality, particularly in mitigating the $3^{\mathrm {rd}}$ harmonic and its multiples, and enhancing the system’s efficiency, reliability, and operational lifespan. The proposed method offers the advantages of being suitable for suppressing both the ZSCC and ZSC and not impacting the control purposes or the system’s output quality. The efficiency and performance of the designed method are validated through various Hardware-in-the-loop (HIL) tests under different conditions using the OPAL-RT-OP5700 real-time simulator.
- Open Access
- 3 April 2023
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 67 (2) , 204-215
New Modeling and Improved Current Control Strategy to Eliminate the Impact of Synchronization Method and Parks Transformation for Grid-connected Four-leg PWM Inverter
The synchronization method’s ability is one of the fundamental guarantees for the stability and accuracy of injected current control for grid-connected converter-based distribution resources. These synchronization methods, such as phase locked loop (PLL), are generally based on Park transformation and grid voltage regulation, which may affect an unstable phenomenon under distortion and unbalanced grid voltage conditions and result in more computational complexity. In this present paper, analogous to the traditional voltage-oriented control strategy (VOC) in the synchronous rotating frame (dq0-frame) based on PLL and Parks transformation, an improved voltage-oriented control strategy (IVOC) without synchronization methods and Parks transformation is proposed for grid-connected four-leg inverters (GC-FLVSI) to achieve accurate current control with high-quality performance in the dq0-frame. This proposed strategy is not only used for controlling the GC-FLVSI but also to provide the module of GC-FLVSI in the dq0-frame based on the instantaneous active and reactive powers theory (DPC). The proposed IVOC strategy has the same properties and identical performance as the traditional VOC when the grid phase angle is correctly detected by any synchronization method, with the advantages of both traditional DPC and VOC at the same time. In order to validate the superiority and excellent dynamic and steady-state performances of the proposed IVOC strategy in comparison with the traditional VOC strategy, some simulation scenarios using MATLAB/Simulink under different operations and grid conditions have been performed and presented.
- 3 April 2023
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Electrical Engineering and Computer Science
- Vol. 67 (2) , 204-215
Open AccessNew Modeling and Improved Current Control Strategy to Eliminate the Impact of Synchronization Method and Parks Transformation for Grid-connected Four-leg PWM Inverter
The synchronization method’s ability is one of the fundamental guarantees for the stability and accuracy of injected current control for grid-connected converter-based distribution resources. These synchronization methods, such as phase locked loop (PLL), are generally based on Park transformation and grid voltage regulation, which may affect an unstable phenomenon under distortion and unbalanced grid voltage conditions and result in more computational complexity. In this present paper, analogous to the traditional voltage-oriented control strategy (VOC) in the synchronous rotating frame (dq0-frame) based on PLL and Parks transformation, an improved voltage-oriented control strategy (IVOC) without synchronization methods and Parks transformation is proposed for grid-connected four-leg inverters (GC-FLVSI) to achieve accurate current control with high-quality performance in the dq0-frame. This proposed strategy is not only used for controlling the GC-FLVSI but also to provide the module of GC-FLVSI in the dq0-frame based on the instantaneous active and reactive powers theory (DPC). The proposed IVOC strategy has the same properties and identical performance as the traditional VOC when the grid phase angle is correctly detected by any synchronization method, with the advantages of both traditional DPC and VOC at the same time. In order to validate the superiority and excellent dynamic and steady-state performances of the proposed IVOC strategy in comparison with the traditional VOC strategy, some simulation scenarios using MATLAB/Simulink under different operations and grid conditions have been performed and presented.