Ilaria Fagioli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ilaria Fagioli has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Emanuele Gruppioni
Centro Protesi INAIL
5 shared publications - Emilio Trigili
BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
5 shared publications - Nicola Vitiello
BioRobotics Institute, Scuola Superiore Sant’Anna, Pontedera, Italy
5 shared publications - Simona Crea
BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
5 shared publications - Alessandro Mazzarini
The BioRobotics Institute, Scuola Superiore SantAnna, Pontedera, Italy
4 shared publications Alessandro Maselli
Institute of Recovery and Care of Scientific Character (IRCCS), Fondazione Don Carlo Gnocchi, Firenze, Italy
2 shared publications
Latest Publications
- 1 January 2027
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 12 (1) , 216-223
Tuning-Free Variable-Impedance Control Over the Full Stride Enhances Walking With Robotic Prostheses
- 1 January 2027
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 12 (1) , 216-223
Tuning-Free Variable-Impedance Control Over the Full Stride Enhances Walking With Robotic Prostheses
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (12) , 19275-19283
Feasibility Study of a Sensorized Prosthetic Foot for Gait Monitoring and Prosthesis Control
The assessment of gait parameters in daily life offers valuable insights for tailoring rehabilitation protocols and personalizing lower-limb assistive devices. Integrating sensory systems into prostheses may enable adaptive control and continuous gait monitoring. Traditional assessment methods such as motion capture, force platforms, and wearable Inertial Measurement Unit (IMU) are effective but often lack seamless integration with prostheses, limiting their use in everyday environments. This article presents a novel plantar sensory system designed for integration with lower-limb prostheses. The system employs optoelectronic plantar pressure sensors embedded between the prosthetic foot and cosmetic cover at load-bearing regions of the gait cycle. Endurance testing confirmed its robustness over prolonged use. Ten healthy subjects participated in a study evaluating the system’s ability to estimate vertical ground reaction force (vGRF) during walking. A Gaussian Process Regressor was trained on sensory signals with force plate data as ground truth. Using leave-one-subject-out cross-validation, the model showed good generalizability (R² = 0.94 ± 0.04), high correlation with force platform data (Pearson r = 0.94 (0.05)), and comparable peak vGRF values. Model stability was assessed by repeating the training 30 times, yielding a coefficient of variation of the RMSE equal to 7.7%. The trained model was also applied to unseen data from two subjects with transtibial amputation, producing physiologically consistent vGRF profiles. The system also promptly detected gait events, identifying heel strike and toe off with median delays of 0.01 s and 0.002 s, respectively. These results support the potential of the system for gait parameter estimation in prosthetic applications.
- 1 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (12) , 19275-19283
Feasibility Study of a Sensorized Prosthetic Foot for Gait Monitoring and Prosthesis Control
The assessment of gait parameters in daily life offers valuable insights for tailoring rehabilitation protocols and personalizing lower-limb assistive devices. Integrating sensory systems into prostheses may enable adaptive control and continuous gait monitoring. Traditional assessment methods such as motion capture, force platforms, and wearable Inertial Measurement Unit (IMU) are effective but often lack seamless integration with prostheses, limiting their use in everyday environments. This article presents a novel plantar sensory system designed for integration with lower-limb prostheses. The system employs optoelectronic plantar pressure sensors embedded between the prosthetic foot and cosmetic cover at load-bearing regions of the gait cycle. Endurance testing confirmed its robustness over prolonged use. Ten healthy subjects participated in a study evaluating the system’s ability to estimate vertical ground reaction force (vGRF) during walking. A Gaussian Process Regressor was trained on sensory signals with force plate data as ground truth. Using leave-one-subject-out cross-validation, the model showed good generalizability (R² = 0.94 ± 0.04), high correlation with force platform data (Pearson r = 0.94 (0.05)), and comparable peak vGRF values. Model stability was assessed by repeating the training 30 times, yielding a coefficient of variation of the RMSE equal to 7.7%. The trained model was also applied to unseen data from two subjects with transtibial amputation, producing physiologically consistent vGRF profiles. The system also promptly detected gait events, identifying heel strike and toe off with median delays of 0.01 s and 0.002 s, respectively. These results support the potential of the system for gait parameter estimation in prosthetic applications.
- Open Access
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 355-365
Postural Control Training With Forces Applied on the Trunk and Pelvis Using a Robotic Upright Stand Trainer (RobUST)
Coordinated control of the trunk and pelvis is critical for performing functional upper-body movements, particularly during standing. Deficits in trunk–pelvis coordination are common in populations with neurological or musculoskeletal impairments, contributing to poor balance and limited functional mobility. In this proof-of-concept study, we investigated training strategies in healthy participants to establish a baseline for future rehabilitation applications. Twenty-four individuals were assigned to one of three groups: (i) control, without assistance (Ctrl), (ii) robotic assistance at the trunk, specifically at the thorax (T), and (iii) robotic assistance applied concurrently at the thorax and pelvis (T-P). Training was delivered using the Robotic Upright Stand Trainer (RobUST), which provides assist-as-needed forces based on deviations from target trajectories and normative thorax–pelvis coordination patterns. Participants were trained to perform elliptical thorax movements while standing, a task with progressively increasing postural demands. Results showed that T-P assistance enabled participants to achieve larger ellipse sizes during training compared to T assistance, suggesting that pelvic support facilitated greater exploration of range of motion. Post-training, ellipse tracing accuracy improved in all groups, but only the T-P and Ctrl groups demonstrated significant gains in movement smoothness. Learning-curve analysis further revealed that while T-P participants required a longer acclimatization period, they ultimately achieved higher combined learning metrics than the T group. These findings highlight the potential of trunk–pelvis coordinated assistance to promote greater improvements in postural control than assistance limited to the trunk. The results provide a foundation for developing trunk–pelvis interventions aimed at improving postural control in clinical populations.
- 23 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 355-365
Open AccessPostural Control Training With Forces Applied on the Trunk and Pelvis Using a Robotic Upright Stand Trainer (RobUST)
Coordinated control of the trunk and pelvis is critical for performing functional upper-body movements, particularly during standing. Deficits in trunk–pelvis coordination are common in populations with neurological or musculoskeletal impairments, contributing to poor balance and limited functional mobility. In this proof-of-concept study, we investigated training strategies in healthy participants to establish a baseline for future rehabilitation applications. Twenty-four individuals were assigned to one of three groups: (i) control, without assistance (Ctrl), (ii) robotic assistance at the trunk, specifically at the thorax (T), and (iii) robotic assistance applied concurrently at the thorax and pelvis (T-P). Training was delivered using the Robotic Upright Stand Trainer (RobUST), which provides assist-as-needed forces based on deviations from target trajectories and normative thorax–pelvis coordination patterns. Participants were trained to perform elliptical thorax movements while standing, a task with progressively increasing postural demands. Results showed that T-P assistance enabled participants to achieve larger ellipse sizes during training compared to T assistance, suggesting that pelvic support facilitated greater exploration of range of motion. Post-training, ellipse tracing accuracy improved in all groups, but only the T-P and Ctrl groups demonstrated significant gains in movement smoothness. Learning-curve analysis further revealed that while T-P participants required a longer acclimatization period, they ultimately achieved higher combined learning metrics than the T group. These findings highlight the potential of trunk–pelvis coordinated assistance to promote greater improvements in postural control than assistance limited to the trunk. The results provide a foundation for developing trunk–pelvis interventions aimed at improving postural control in clinical populations.
- Open Access
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (4) , 1409-1422
Advancements and Challenges in the Development of Robotic Lower Limb Prostheses: A Systematic Review
Lower limb prosthetics, essential for restoring mobility in individuals with limb loss, have witnessed significant advancements in recent years. This systematic review reports the recent research advancements in the field of semi-active and active lower-limb prostheses. The review focuses on the mechatronic features of the devices, the sensing and control strategies, and the performance verification with end-users. A total of 53 prosthetic prototypes were identified and analyzed, including 16 knee-ankle prostheses, 18 knee prostheses, and 19 ankle prostheses. The review highlights some of the open challenges in the field of prosthetic research.
- 19 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 6 (4) , 1409-1422
Open AccessAdvancements and Challenges in the Development of Robotic Lower Limb Prostheses: A Systematic Review
Lower limb prosthetics, essential for restoring mobility in individuals with limb loss, have witnessed significant advancements in recent years. This systematic review reports the recent research advancements in the field of semi-active and active lower-limb prostheses. The review focuses on the mechatronic features of the devices, the sensing and control strategies, and the performance verification with end-users. A total of 53 prosthetic prototypes were identified and analyzed, including 16 knee-ankle prostheses, 18 knee prostheses, and 19 ankle prostheses. The review highlights some of the open challenges in the field of prosthetic research.
- Open Access
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3306-3321
An Underactuated Active Transfemoral Prosthesis With Series Elastic Actuators Enables Multiple Locomotion Tasks
Robotic lower-limb prostheses have the power to revolutionize mobility by enhancing gait efficiency and facilitating movement. While several design approaches have been explored to create lightweight and energy-efficient devices, the potential of underactuation remains largely untapped in lower-limb prosthetics. Taking inspiration from the natural harmony of walking, we have developed an innovative active transfemoral prosthesis. By incorporating underactuation, our design uses a single power actuator placed near the knee joint and connected to a differential mechanism to drive both the knee and ankle joints. We conducted comprehensive benchtop tests and evaluated the prosthesis with three individuals who have above-knee amputations, assessing its performance in walking, stair climbing, and transitions between sitting and standing. Our evaluation focused on gathering position and torque data recorded from sensors integrated into the prosthesis and comparing these measurements to biomechanical data of able-bodied locomotion. Our findings highlight the promise of underactuation in advancing lower-limb prosthetics and demonstrate the feasibility of our kneeankle underactuated design in various tasks, showcasing its ability to replicate natural movement
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 40 (15523098) , 3306-3321
Open AccessAn Underactuated Active Transfemoral Prosthesis With Series Elastic Actuators Enables Multiple Locomotion Tasks
Robotic lower-limb prostheses have the power to revolutionize mobility by enhancing gait efficiency and facilitating movement. While several design approaches have been explored to create lightweight and energy-efficient devices, the potential of underactuation remains largely untapped in lower-limb prosthetics. Taking inspiration from the natural harmony of walking, we have developed an innovative active transfemoral prosthesis. By incorporating underactuation, our design uses a single power actuator placed near the knee joint and connected to a differential mechanism to drive both the knee and ankle joints. We conducted comprehensive benchtop tests and evaluated the prosthesis with three individuals who have above-knee amputations, assessing its performance in walking, stair climbing, and transitions between sitting and standing. Our evaluation focused on gathering position and torque data recorded from sensors integrated into the prosthesis and comparing these measurements to biomechanical data of able-bodied locomotion. Our findings highlight the promise of underactuation in advancing lower-limb prosthetics and demonstrate the feasibility of our kneeankle underactuated design in various tasks, showcasing its ability to replicate natural movement
- Open Access
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1397-1406
Improving Walking Energy Efficiency in Transtibial Amputees Through the Integration of a Low-Power Actuator in an ESAR Foot
Reducing energy consumption during walking is a critical goal for transtibial amputees. The study presents the evaluation of a semi-active prosthesis with five transtibial amputees. The prosthesis has a low-power actuator integrated in parallel into an energy-storing-and-releasing foot. The actuator is controlled to compress the foot during the stance phase, supplementing the natural compression due to the user’s dynamic interaction with the ground, particularly during the ankle dorsiflexion phase, and to release the energy stored in the foot during the push-off phase, to enhance propulsion. The control strategy is adaptive to the user’s gait patterns and speed. The clinical protocol to evaluate the system included treadmill and overground walking tasks. The results showed that walking with the semi-active prosthesis reduced the Physiological Cost Index of transtibial amputees by up to 16% compared to walking using the subjects’ proprietary prosthesis. No significant alterations were observed in the spatiotemporal gait parameters of the participants, indicating the module’s compatibility with users’ natural walking patterns. These findings highlight the potential of the mechatronic actuator in effectively reducing energy expenditure during walking for transtibial amputees. The proposed prosthesis may bring a positive impact on the quality of life, mobility, and functional performance of individuals with transtibial amputation.
- 20 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 32 (15344320) , 1397-1406
Open AccessImproving Walking Energy Efficiency in Transtibial Amputees Through the Integration of a Low-Power Actuator in an ESAR Foot
Reducing energy consumption during walking is a critical goal for transtibial amputees. The study presents the evaluation of a semi-active prosthesis with five transtibial amputees. The prosthesis has a low-power actuator integrated in parallel into an energy-storing-and-releasing foot. The actuator is controlled to compress the foot during the stance phase, supplementing the natural compression due to the user’s dynamic interaction with the ground, particularly during the ankle dorsiflexion phase, and to release the energy stored in the foot during the push-off phase, to enhance propulsion. The control strategy is adaptive to the user’s gait patterns and speed. The clinical protocol to evaluate the system included treadmill and overground walking tasks. The results showed that walking with the semi-active prosthesis reduced the Physiological Cost Index of transtibial amputees by up to 16% compared to walking using the subjects’ proprietary prosthesis. No significant alterations were observed in the spatiotemporal gait parameters of the participants, indicating the module’s compatibility with users’ natural walking patterns. These findings highlight the potential of the mechatronic actuator in effectively reducing energy expenditure during walking for transtibial amputees. The proposed prosthesis may bring a positive impact on the quality of life, mobility, and functional performance of individuals with transtibial amputation.
- Open Access
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 1248-1257
Looking for Synergies in Healthy Upper Limb Motion: A Focus on the Wrist
Recent studies on human upper limb motion highlighted the benefit of dimensionality reduction techniques to extrapolate informative joint patterns. These techniques can simplify the description of upper limb kinematics in physiological conditions, serving as a baseline for the objective assessment of movement alterations, or to be implemented in a robotic joint. However, the successful description of kinematic data requires a proper alignment of the acquisitions to correctly estimate kinematic patterns and their motion variability. Here, we propose a structured methodology to process and analyze upper limb kinematic data, considering time warping and task segmentation to register task execution on a common normalized completion time axis. Functional principal component analysis (fPCA) was used to extract patterns of motion of the wrist joint from the data collected by healthy participants performing activities of daily living. Our results suggest that wrist trajectories can be described as a linear combination of few functional principal components (fPCs). In fact, three fPCs explained more than 85% of the variance of any task. Wrist trajectories in the reaching phase of movement were highly correlated among participants and significantly more than trajectories in the manipulation phase (p<0.01). These findings may be useful in simplifying the control and design of robotic wrists, and could aid the development of therapies for the early detection of pathological conditions.
- 9 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 31 (15344320) , 1248-1257
Open AccessLooking for Synergies in Healthy Upper Limb Motion: A Focus on the Wrist
Recent studies on human upper limb motion highlighted the benefit of dimensionality reduction techniques to extrapolate informative joint patterns. These techniques can simplify the description of upper limb kinematics in physiological conditions, serving as a baseline for the objective assessment of movement alterations, or to be implemented in a robotic joint. However, the successful description of kinematic data requires a proper alignment of the acquisitions to correctly estimate kinematic patterns and their motion variability. Here, we propose a structured methodology to process and analyze upper limb kinematic data, considering time warping and task segmentation to register task execution on a common normalized completion time axis. Functional principal component analysis (fPCA) was used to extract patterns of motion of the wrist joint from the data collected by healthy participants performing activities of daily living. Our results suggest that wrist trajectories can be described as a linear combination of few functional principal components (fPCs). In fact, three fPCs explained more than 85% of the variance of any task. Wrist trajectories in the reaching phase of movement were highly correlated among participants and significantly more than trajectories in the manipulation phase (p<0.01). These findings may be useful in simplifying the control and design of robotic wrists, and could aid the development of therapies for the early detection of pathological conditions.