AHAmir Hassankhani

Amir Hassankhani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Amir Hassankhani has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Diagnostic Accuracy of Magnetic Resonance Elastography and Diffusion-Weighted Imaging in Differentiating Benign and Malignant Focal Liver Lesions: A Systematic Review and Meta-Analysis

    by Amir Hassankhani, Parya Valizadeh, Payam Jannatdoust, Melika Amoukhteh, Abbas Mohammadi, Ali Gholamrezanezhad, Ali Haq

    Background: Accurate differentiation of benign and malignant focal liver lesions (FLLs) is essential for clinical decision-making. Magnetic resonance elastography (MRE) and diffusion-weighted imaging (DWI) are advanced MRI techniques used for noninvasive lesion characterization, but their comparative diagnostic performance has not been definitively established. Objective: To systematically compare the diagnostic accuracy of MRE and DWI for distinguishing benign from malignant FLLs. Methods: A systematic review and meta-analysis were conducted following PRISMA guidelines. PubMed, Embase, and Scopus were searched through July 2025 for studies directly comparing MRE and DWI in the same patient cohorts with focal liver lesions, using histopathology or validated imaging follow-up as the reference standard. Sensitivity, specificity, and area under the curve (AUC) were pooled using bivariate random-effects models, with paired analysis to compare modalities. Results: 219 patients with 284 focal liver lesions were analyzed. MRE demonstrated higher pooled sensitivity (93.8%, 95% CI: 85.6–97.5) and specificity (89.9%, 95% CI: 74.6–96.4) than DWI (sensitivity 86.2%, 95% CI: 80.5–90.5; specificity 83.4%, 95% CI: 74.3–89.8). MRE also had a higher AUC (0.97 vs. 0.88). Likelihood ratio analysis indicated MRE’s stronger ability to both confirm and exclude malignancy. Paired meta-analysis confirmed a statistically significant increase in sensitivity for MRE (relative sensitivity 1.09; p = 0.018), with no significant difference in specificity. Conclusion: MRE demonstrates superior sensitivity and overall diagnostic accuracy compared to DWI for differentiating benign and malignant FLLs. Further large-scale prospective studies are needed to confirm these results and determine optimal cutoff values to guide clinical decision-making.

  • Open Access

    Diagnostic Value of Elastography in Differentiating Parathyroid Adenoma from Hyperplasia: A Systematic Review and Meta-Analysis

    by Amir Hassankhani, Payam Jannatdoust, Parya Valizadeh, Melika Amoukhteh, Abbas Mohammadi, Ali Gholamrezanezhad, Ali Haq

    Background: Differentiating parathyroid adenoma from hyperplasia is critical for surgical planning, but conventional imaging often cannot reliably distinguish these lesions. Ultrasound elastography offers quantitative assessment of tissue stiffness and may improve preoperative characterization. Purpose: To evaluate the diagnostic accuracy of ultrasound elastography in differentiating parathyroid adenoma from hyperplasia. Methods: A systematic review and meta-analysis was conducted in accordance with PRISMA guidelines. PubMed, Scopus, and Embase were searched through July 2025, for studies assessing elastography for parathyroid lesion differentiation. Data on sensitivity, specificity, and other diagnostic metrics were extracted and pooled using a bivariate random-effects model in R software. Results: Five studies comprising 579 parathyroid lesions were included, of which four studies with 352 adenomas and 202 hyperplasias were eligible for pooled analysis. Pooled sensitivity and specificity of elastography were 83.3% (95% CI: 74.3–89.6%) and 79.1% (95% CI: 65.5–88.3%), respectively, with an area under the SROC curve of 0.88 (95% CI: 0.79–0.92). Pooled likelihood ratios were 4.14 for a positive test and 0.216 for a negative test. Fagan nomogram analysis showed that, for a patient with a 50% pre-test probability of adenoma, a positive result increased post-test probability to 81%, while a negative result decreased it to 18%. Conclusion: Ultrasound elastography demonstrates good diagnostic performance in distinguishing parathyroid adenomas from hyperplasia and may help inform preoperative planning.

  • Initial Experience with the Pipeline Vantage Flow Diverter for Intracranial Aneurysms: A Systematic Review and Meta-Analysis

    by Jonathan Cortese, Sherief Ghozy, Parya Valizadeh, Alireza Hasanzadeh, Melika Amoukhteh, Payam Jannatdoust, Amir Hassankhani, Ali Ahmadzade, Dan Adrian Popica, David F. Kallmes, et al.

    Background: The Pipeline Vantage Flow diverter (Vantage) is the latest generation of Pipeline flow diverters introducing Cobalt-chronium drawn-filled tubing and 48 to 68 wires. Purpose: We report the initial safety and efficacy of Vantage in treating intracranial aneurysms in the published literature. Data Sources: A systematic review and meta-analysis was conducted according to established protocols. Searches were conducted in PubMed, Scopus, Web-of-Science, and Embase databases up to December 2023. Original studies reporting treatment outcomes for intracranial aneurysms using Vantage in more than five patients were included. Study Selection: Pooled data from 5 studies (373 patients, 418 aneurysms) were analyzed. Data Analysis: Outcomes of interest were: technical success, occlusion rates, complication outcomes and mortality. Data Synthesis: A technical success rate of 99.2% (95% CI: 98.29%–100%) was found. In unruptured cases, success rate was 378/383 (99.6%) versus 17/20 (85.0%) in ruptured cases (P < .01). Complete occlusion rate was 74.3% (95% CI: 67.43%–80.59%), with no significant difference between ruptured and unruptured cases (P = 0.72); median of follow up 6 months. Overall mortality rate was 1.2% (95% CI: 0.01%–3.64%), significantly higher in ruptured (18.6%; 95% CI: 5.13%–36.26%) versus unruptured cases (0.23%; 95% CI: 0%–1.36%) (P < 0.01). Hemorrhagic complications occurred at 1% (95% CI: 0%–3.36%) pooled rate. Thromboembolic complications were reported at 6.1% (95% CI: 2.60%–10.73%), decreasing to 4.35% (95% CI: 1.91%–7.54%) after excluding one outlier study. Limitations: Only five studies, some with small number of patients, were included in this meta-analysis which may limit the generalizability of our findings. The absence of long term follow-up also limits the assessment of treatment durability. Conclusions: In this meta-analysis, we found that Vantage initial experience is similar to previous version of the Pipeline Embolization Device in terms of safety and efficacy for treatment of intracranial aneurysms, in particular unruptured aneurysms. Further prospective and comparative studies with patient outcome data specific to aneurysm location are needed to confirm the safety and efficacy of Vantage.


  • Open Access

    Correction: Net water uptake as a predictive neuroimaging marker for acute ischemic stroke outcomes: a meta-analysis

    by Sherief Ghozy, Melika Amoukhteh, Alireza Hasanzadeh, Payam Jannatdoust, Mahan Shafie, Parya Valizadeh, Amir Hassankhani, Alzhraa Salah Abbas, Ramanathan Kadirvel, David F. Kallmes

  • Diversity Patterns in Interventional Radiology Residency Applicants

    by Parya Valizadeh, Payam Jannatdoust, Amir Hassankhani, Melika Amoukhteh, Paniz Adli, Benjamin Robert Jacobson, Sherief Ghozy, Pauravi S. Vasavada, David F. Kallmes, Ali Gholamrezanezhad

  • Comparative meta-analysis of endovascular strategies for intracranial dissecting aneurysms: Flow diverters versus stents with or without coiling

    by Melika Amoukhteh, Amir Hassankhani, Payam Jannatdoust, Parya Valizadeh, Sherief Ghozy, Cem Bilgin, David F Kallmes

    Background: Intracranial dissecting aneurysms present a challenging subset linked to considerable morbidity and mortality, necessitating effective therapeutic strategies to prevent complications. Traditional treatments face technical limitations, while emerging endovascular modalities like stent-assisted coiling, multiple stenting, and flow-diverting devices (FDDs) offer promise in reducing periprocedural risks and enhancing patient outcomes. The aim of this study is to compare the safety and efficacy outcomes of endovascular treatment for intracranial dissecting aneurysms using FDDs versus stents (with or without coiling). Methods: A systematic review and meta-analysis were conducted following established guidelines. The search included PubMed, Scopus, Web of Science, and Embase databases up to July 30, 2023. Eligible studies reporting outcomes of interest in both FDD and stent-treated groups were included, and the data was extracted and analyzed using STATA software. Results: Six studies were analyzed, involving 131 patients in the FDD group and 199 patients in the stent group. The pooled rates for favorable functional outcomes (86.8% vs. 86%), mortality (3.9% vs. 6%), adequate occlusion (79.7% vs. 86.3%), aneurysm recurrence (1.3% vs. 13.3%), in-stent stenosis/thrombosis (7% vs. 6.9%), ischemic events/infarctions (6.7% vs. 7.8%), retreatment (7% vs. 8.6%), and technical success (100% vs. 98.7%) were comparable in individuals treated with FDDs and stents (p > 0.05 in all cases). Additionally, complete occlusion rates were not significantly different between FDD (62.7%) and stent-treated patients (75.2%) (p = 0.06). However, after excluding one study in a leave-one-out analysis of the random effects meta-analysis, a significant difference in the pooled rates of this outcome was observed between the FDD (59.2%) and stent (75.2%) groups (p = 0.034). Conclusion: FDDs present a promising approach for the treatment of intracranial dissecting aneurysms, yielding outcomes that are roughly comparable to stent-based methods. However, the absence of randomized trials and data limitations highlight the need for further research to enhance treatment strategies.


  • Open Access

    Mechanical Thrombectomy for In-Hospital Onset Stroke: A Comparative Systematic Review and Meta-Analysis

    by Melika Amoukhteh, Amir Hassankhani, Sherief Ghozy, Parya Valizadeh, Payam Jannatdoust, Cem Bilgin, Ramanathan Kadirvel, David F. Kallmes

    Background and Purpose In-hospital onset stroke (IHOS) accounts for a significant proportion of large vessel occlusion acute ischemic strokes, leading to worse outcomes due to delays in evaluation and treatment. Limited data is available on the effectiveness of mechanical thrombectomy in IHOS patients. This study aims to assess the safety and efficacy of mechanical thrombectomy for patients with IHOS and compare the outcomes with those of community-onset strokes (COS).Methods We conducted a systematic review and meta-analysis following established guidelines, by searching PubMed, Scopus, Web of Science, and Embase databases up to April 11, 2023. Eligible studies reporting outcomes of interest were included, and relevant data was extracted and analyzed using Stata software version 17.0.Results In a meta-analysis of nine studies, comprising 540 cases of IHOS and 5,744 cases of COS, IHOS cases had a significantly lower rate of good functional outcomes on follow-up (35.46% vs. 40.74%, P<0.01) and a higher follow-up mortality rate (26.29% vs. 18.08%, P<0.01) compared to COS patients. Both groups had comparable successful recanalization rates (IHOS: 79.32% vs. COS: 81.44%, P=0.11), incidence rates of periprocedural complications (IHOS: 15.10%, COS: 12.96%, P=0.78), and symptomatic intracranial hemorrhage (IHOS: 6.24%, COS: 6.88%, P=0.67). It is worth noting that much of the observed effect size for mortality and good functional outcomes on follow-up was derived from only one and two studies, respectively.Conclusion While the current literature suggests that mechanical thrombectomy is a safe and effective treatment for IHOS, further research is necessary to comprehensively evaluate its impact, particularly during follow-up.


  • Beyond the H-Index and Toward a Comprehensive Framework

    by Amir Hassankhani, Melika Amoukhteh, Pauravi S. Vasavada, Ali Gholamrezanezhad


  • Net water uptake as a predictive neuroimaging marker for acute ischemic stroke outcomes: a meta-analysis

    by Sherief Ghozy, Melika Amoukhteh, Alireza Hasanzadeh, Payam Jannatdoust, Mahan Shafie, Parya Valizadeh, Amir Hassankhani, Alzhraa Salah Abbas, Ramanathan Kadirvel, David F. Kallmes

    Objective To assess the role of net water uptake (NWU) in predicting outcomes in acute ischemic stroke (AIS) patients. Methods A systematic review and meta-analysis were performed, adhering to established guidelines. The search covered PubMed, Scopus, Web of Science, and Embase databases until July 1, 2023. Eligible studies reporting quantitative ischemic lesion NWU in admission CT scans of AIS patients, stratified based on outcomes, were included. Data analysis was performed using R software version 4.2.1. Results Incorporating 17 original studies with 2217 AIS patients, NWU was significantly higher in patients with poor outcomes compared to those with good outcomes (difference of medians: 5.06, 95% CI: 3.00–7.13, p < 0.001). Despite excluding one outlier study, considerable heterogeneity persisted among the included studies (I2 = 90.8%). The meta-regression and subgroup meta-analyses demonstrated significantly higher NWU in patients with poor functional outcome, as assessed by modified Rankin Scale (difference of medians: 3.83, 95% CI: 1.98–5.68, p < 0.001, I2 = 72.9%), malignant edema/infarct (difference of medians: 8.30, 95% CI: 4.01–12.58, p < 0.001, I2 = 95.6%), and intracranial hemorrhage (difference of medians: 5.43, 95% CI: 0.44–10.43, p = 0.03, I2 = 91.1%). Conclusion NWU on admission CT scans shows promise as a predictive marker for outcomes in AIS patients. Prospective, multicenter trials with standardized, automated NWU measurement are crucial for robustly predicting diverse clinical outcomes. Clinical relevance statement The potential of net water uptake as a biomarker for predicting outcomes in acute ischemic stroke patients holds significant promise. Further validation through additional research could lead to its integration into clinical practice, potentially improving the accuracy of clinical decision-making and allowing for the development of more precise patient care strategies. Key Points • Net water uptake, a CT-based biomarker, quantifies early brain edema after acute ischemic stroke. • Net water uptake is significantly higher in poor outcome acute ischemic stroke patients. • Net water uptake on CT scans holds promise in predicting diverse acute ischemic stroke outcomes.


  • Flow diverters in the treatment of intracranial dissecting aneurysms: a systematic review and meta-analysis of safety and efficacy

    by Melika Amoukhteh, Amir Hassankhani, Parya Valizadeh, Payam Jannatdoust, Sherief Ghozy, Hassan Kobeissi, David F Kallmes

    Background Intracranial dissecting aneurysms present clinical challenges, demanding immediate intervention due to their high bleeding risk. While traditional treatments have limitations, the potential of flow diverters shows promise but remains a subject of ongoing debate for optimal management. The aim of this study was assess the safety and efficacy of flow diverters in the treatment of intracranial dissecting aneurysms. Methods A systematic review and meta-analysis was performed following established guidelines. The search encompassed PubMed, Scopus, Web of Science, and Embase databases up to July 20, 2023. Eligible studies reporting outcomes of interest were included, and relevant data were extracted and analyzed using R software. Results The analysis, based on data pooled from 20 included studies involving 329 patients, revealed a favorable functional outcome rate of 89.7% at the last follow-up. The mortality rate during the follow-up period was 2.4%, decreasing to 0.9% when excluding the outlier study. In the final angiographic follow-up, a complete occlusion rate of 71.7% and an adequate occlusion rate of 88.3% were observed. Notably, studies with longer angiographic follow-up times exhibited lower rates of complete (P=0.02) and adequate (PConclusion This study highlights the safety and efficacy of flow diverters in treating intracranial dissecting aneurysms. Further research, encompassing larger multicenter studies with extended follow-up periods, is crucial for comprehending occlusion dynamics, refining treatment strategies, improving long-term outcomes, and addressing methodological limitations.