Julien Aguet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Julien Aguet has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
Birgit Ertl-Wagner
4 shared publicationsOlivier Villemain
Department of Pediatrics, Division of Cardiology, The Hospital for Sick Children, University of Toronto, Toronto, Canada
4 shared publicationsAnish Kirpalani
3 shared publicationsHeidi Schmidt
3 shared publications- Kate Hanneman
Department of Medical Imaging, Temerty Faculty of Medicine, University of Toronto, Toronto, Ontario, Canada
3 shared publications Chloe DesRoche
2 shared publications
Latest Publications
- 4 August 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (12) , 2797-2806
Ultrafast shear-wave elastography for pediatric deep vein thrombosis: a prospective feasibility study
- 4 August 2026
- Published by Springer Nature in Pediatric Radiology
- Vol. 56 (12) , 2797-2806
Ultrafast shear-wave elastography for pediatric deep vein thrombosis: a prospective feasibility study
- Open Access
- 11 June 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
Projected Increases in Heat-Related Emergency Department Imaging Utilization Under Climate Change Scenarios
Background: The impact of climate-driven warming on future demand for medical imaging remains unclear. Purpose: To project temperature-attributable excess imaging volumes requested by emergency departments (ED) under future climate scenarios. Methods: Associations between ambient temperature and imaging utilization were estimated during the baseline period (2013-2022) using data from 5 EDs in Toronto. Baseline exposure–response relationships were applied to statistically downscaled, bias-corrected daily temperature projections through 2092 from an ensemble of 23 general circulation models. Temperature-attributable excess ED imaging volumes were projected by decade under 3 Shared Socioeconomic Pathways (SSPs). Results: Higher ambient temperature was associated with increased imaging utilization at baseline (incidence rate ratio 1.033; 95% CI, 1.028-1.037; P < .001). Temperature-attributable emergency medical imaging utilization is projected to increase under all climate scenarios. Relative increases ranged from 0.04% to 0.10% in the early period (2023-2032), with a 3- to 12-fold increase over the study period. By 2083 to 2092, temperature-attributable emergency imaging utilization is projected to increase by 0.32% (95% CI, 0.28-0.37) under the SSP1-2.6 low-emissions scenario and by 1.25% (95% CI, 1.08-1.43) under the SSP3-7.0 high-emissions scenario. This corresponds to annual excess imaging studies attributable to rising temperatures of 570 (95% CI, 488-655) to 2219 (95% CI, 1922-2528) locally, and 13 900 (95% CI, 11 900-15 950) to 55 475 (95% CI, 48 050-63 200) across Canada. Conclusion: Climate-driven warming is projected to increase emergency imaging utilization across all emissions scenarios. These findings support the need for climate-informed radiology planning and integration of adaptation and mitigation strategies to sustain health system capacity.
- 11 June 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
Open AccessProjected Increases in Heat-Related Emergency Department Imaging Utilization Under Climate Change Scenarios
Background: The impact of climate-driven warming on future demand for medical imaging remains unclear. Purpose: To project temperature-attributable excess imaging volumes requested by emergency departments (ED) under future climate scenarios. Methods: Associations between ambient temperature and imaging utilization were estimated during the baseline period (2013-2022) using data from 5 EDs in Toronto. Baseline exposure–response relationships were applied to statistically downscaled, bias-corrected daily temperature projections through 2092 from an ensemble of 23 general circulation models. Temperature-attributable excess ED imaging volumes were projected by decade under 3 Shared Socioeconomic Pathways (SSPs). Results: Higher ambient temperature was associated with increased imaging utilization at baseline (incidence rate ratio 1.033; 95% CI, 1.028-1.037; P < .001). Temperature-attributable emergency medical imaging utilization is projected to increase under all climate scenarios. Relative increases ranged from 0.04% to 0.10% in the early period (2023-2032), with a 3- to 12-fold increase over the study period. By 2083 to 2092, temperature-attributable emergency imaging utilization is projected to increase by 0.32% (95% CI, 0.28-0.37) under the SSP1-2.6 low-emissions scenario and by 1.25% (95% CI, 1.08-1.43) under the SSP3-7.0 high-emissions scenario. This corresponds to annual excess imaging studies attributable to rising temperatures of 570 (95% CI, 488-655) to 2219 (95% CI, 1922-2528) locally, and 13 900 (95% CI, 11 900-15 950) to 55 475 (95% CI, 48 050-63 200) across Canada. Conclusion: Climate-driven warming is projected to increase emergency imaging utilization across all emissions scenarios. These findings support the need for climate-informed radiology planning and integration of adaptation and mitigation strategies to sustain health system capacity.
- 20 January 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (2) , 271-272
The Clinician in the Reading Room: Rediscovering Our Clinical Voice
- 20 January 2026
- Published by SAGE Publications in Canadian Association of Radiologists Journal
- Vol. 77 (2) , 271-272
The Clinician in the Reading Room: Rediscovering Our Clinical Voice
- 1 November 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (2) , e241624
Increased Emergency Department Medical Imaging: Association with Short-Term Exposures to Ambient Heat and Particulate Air Pollution
In an analysis of data collected over a 10-year period from four emergency departments, short-term exposures to ambient heat and particulate air pollution were associated with increased utilization of radiography and CT but not US or MRI.
- 1 November 2024
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 313 (2) , e241624
Increased Emergency Department Medical Imaging: Association with Short-Term Exposures to Ambient Heat and Particulate Air Pollution
In an analysis of data collected over a 10-year period from four emergency departments, short-term exposures to ambient heat and particulate air pollution were associated with increased utilization of radiography and CT but not US or MRI.
- 6 August 2024
- Published by Springer Nature
- p. 387-420
Fetal Cardiovascular MRI
- 19 October 2023
- Published by Springer Nature
- p. 1-34
Fetal cardiovascular MRI
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (8) , 821-830
Fast Thresholding of SVD Clutter Filter Using the Spatial Similarity Matrix and a Sum-Table Algorithm
Singular value decomposition (SVD) has become a standard for clutter filtering of ultrafast ultrasound datasets. Its implementation requires the choice of appropriate thresholds to discriminate the singular value subspaces associated to tissue, blood and noise signals. Comparing the similarity of the spatial singular vectors was shown to be a robust and efficient method to estimate the SVD thresholds. The correlation of the spatial singular vectors envelopes gives the spatial similarity matrix (SSM), which usually exhibits two square-like domains juxtaposed along the diagonal of the SSM, representing the tissue and the blood subspaces. Up to now, the proposed methods to automatically segment these two subspaces on the SSM were of high computational complexity and had long processing time. Here we propose an optimized algorithm using a sum-table approach that decreases the complexity by two orders of magnitude: O(n 4 ) to O(n 2 ). The proposed method resulted in processing times lower than 0.08s for datasets of 2000 frames, whereas previous algorithms took more than 26 hours, so an improvement by a factor 10 6 . We illustrated this adaptive square-fitting on the SSM in the in VIVO case of human neonate brain imaging and carotid imaging with various conditions of clutter. This optimization of SVD thresholding is essential to develop the use of adaptive clutter filtering, especially for real-time applications or block-wise processing.
- 26 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 70 (8) , 821-830
Fast Thresholding of SVD Clutter Filter Using the Spatial Similarity Matrix and a Sum-Table Algorithm
Singular value decomposition (SVD) has become a standard for clutter filtering of ultrafast ultrasound datasets. Its implementation requires the choice of appropriate thresholds to discriminate the singular value subspaces associated to tissue, blood and noise signals. Comparing the similarity of the spatial singular vectors was shown to be a robust and efficient method to estimate the SVD thresholds. The correlation of the spatial singular vectors envelopes gives the spatial similarity matrix (SSM), which usually exhibits two square-like domains juxtaposed along the diagonal of the SSM, representing the tissue and the blood subspaces. Up to now, the proposed methods to automatically segment these two subspaces on the SSM were of high computational complexity and had long processing time. Here we propose an optimized algorithm using a sum-table approach that decreases the complexity by two orders of magnitude: O(n 4 ) to O(n 2 ). The proposed method resulted in processing times lower than 0.08s for datasets of 2000 frames, whereas previous algorithms took more than 26 hours, so an improvement by a factor 10 6 . We illustrated this adaptive square-fitting on the SSM in the in VIVO case of human neonate brain imaging and carotid imaging with various conditions of clutter. This optimization of SVD thresholding is essential to develop the use of adaptive clutter filtering, especially for real-time applications or block-wise processing.
- Open Access
- 12 April 2023
- Published by Elsevier in JACC: Advances
- Vol. 2 (3) , 100290
Ultrafast Power Doppler for Detecting Intraoperative Myocardial Perfusion in Infants With Critical Congenital Heart Disease
- 12 April 2023
- Published by Elsevier in JACC: Advances
- Vol. 2 (3) , 100290
Open AccessUltrafast Power Doppler for Detecting Intraoperative Myocardial Perfusion in Infants With Critical Congenital Heart Disease
- Open Access
- 28 February 2023
- Published by Wiley in The Journal of Physiology
- Vol. 601 (6) , 1077-1093
Impact of cardiopulmonary bypass on cerebrovascular autoregulation assessed by ultrafast ultrasound imaging
Newborns with congenital heart disease undergoing cardiac surgery are at risk of neurodevelopmental impairment with limited understanding of the impact of intra‐operative cardiopulmonary bypass (CPB), deep hypothermia and selective cerebral perfusion on the brain. We hypothesized that a novel ultrasound technique, ultrafast power Doppler (UPD), can assess variations of cerebral blood volume (CBV) in neonates undergoing cardiac surgery requiring CPB. UPD was performed before, during and after surgery in newborns with hypoplastic left heart syndrome undergoing a Norwood operation. We found that global CBV was not significantly different between patients and controls (P = 0.98) and between pre‐ and post‐surgery (P = 0.62). UPD was able to monitor changes in CBV throughout surgery, revealing regional differences in CBV during hypothermia during which CBV correlated with CPB flow rate (R2 = 0.52, P = 0.021). Brain injury on post‐operative magnetic resonance imaging was observed in patients with higher maximum variation in CBV. Our findings suggest that UPD can quantify global and regional brain perfusion variation during neonatal cardiac surgery with this first intra‐operative application demonstrating an association between CBV and CPB flow rate, suggesting loss of autoregulation. Therefore, the measurement of CBV by UPD could enable optimization of cerebral perfusion during cardiac surgery in neonates. image Key points: The impact of cardiopulmonary bypass (CPB) on the neonatal brain undergoing cardiac surgery is poorly understood. Ultrafast power Doppler (UPD) quantifies cerebral blood volume (CBV), a surrogate of brain perfusion. CBV varies throughout CPB surgery and is associated with variation of the bypass pump flow rate during deep hypothermia. Association between CBV and bypass pump flow rate suggests loss of cerebrovascular autoregulatory processes. Quantitative monitoring of cerebral perfusion by UPD could provide a direct parameter to optimize CPB flow rate.
- 28 February 2023
- Published by Wiley in The Journal of Physiology
- Vol. 601 (6) , 1077-1093
Open AccessImpact of cardiopulmonary bypass on cerebrovascular autoregulation assessed by ultrafast ultrasound imaging
Newborns with congenital heart disease undergoing cardiac surgery are at risk of neurodevelopmental impairment with limited understanding of the impact of intra‐operative cardiopulmonary bypass (CPB), deep hypothermia and selective cerebral perfusion on the brain. We hypothesized that a novel ultrasound technique, ultrafast power Doppler (UPD), can assess variations of cerebral blood volume (CBV) in neonates undergoing cardiac surgery requiring CPB. UPD was performed before, during and after surgery in newborns with hypoplastic left heart syndrome undergoing a Norwood operation. We found that global CBV was not significantly different between patients and controls (P = 0.98) and between pre‐ and post‐surgery (P = 0.62). UPD was able to monitor changes in CBV throughout surgery, revealing regional differences in CBV during hypothermia during which CBV correlated with CPB flow rate (R2 = 0.52, P = 0.021). Brain injury on post‐operative magnetic resonance imaging was observed in patients with higher maximum variation in CBV. Our findings suggest that UPD can quantify global and regional brain perfusion variation during neonatal cardiac surgery with this first intra‐operative application demonstrating an association between CBV and CPB flow rate, suggesting loss of autoregulation. Therefore, the measurement of CBV by UPD could enable optimization of cerebral perfusion during cardiac surgery in neonates. image Key points: The impact of cardiopulmonary bypass (CPB) on the neonatal brain undergoing cardiac surgery is poorly understood. Ultrafast power Doppler (UPD) quantifies cerebral blood volume (CBV), a surrogate of brain perfusion. CBV varies throughout CPB surgery and is associated with variation of the bypass pump flow rate during deep hypothermia. Association between CBV and bypass pump flow rate suggests loss of cerebrovascular autoregulatory processes. Quantitative monitoring of cerebral perfusion by UPD could provide a direct parameter to optimize CPB flow rate.