YHYan Huang

Yan Huang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan Huang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep Learning-Enhanced Lateral-Flow Microarray Biosensor for Multiplexed Inflammatory Biomarker Analysis

    by Yongxiang Ji, Qi Guo, Shuqing Wang, Yan Huang, Zhixia Huang, Zhongzeng Zhou, Yibiao Liu, Conghui Liu, Tailin Xu, Xueji Zhang

    Beyond simply functional integration, achieving synergistic enhancements in multiplex detection, quantitative robustness, and intelligent analysis remains a key challenge for next-generation biosensing platforms in precision diagnostics. Lateral flow biosensors are attractive paper-based platforms because of their simplicity, low cost, and rapid operation; however, conventional line-type formats and visual readouts may limit their multiplex quantitative capability. Here, we present a surface-enhanced Raman scattering-based lateral flow microarray chip (LF-SERS-MAC) platform that integrates spatially encoded microarray patterns with AI-assisted analysis to enable sensitive, specific, and stable detection of three inflammatory proteins on a single paper device. The platform employs AuNPDTNB@antibody nanoprobes that simultaneously provide strong Raman signals and specific recognition of target proteins. The 4 × 4 microarray architecture enables spatially separated detection channels and predefined replicate microdots, supporting standardized SERS sampling and replicate-based signal averaging. More importantly, a 2D transformation-based deep learning model was developed for inflammation classification and concentration prediction, which demonstrates higher accuracy than conventional AI models. This platform can be further scaled to high-throughput paper chips, facilitating its clinical translation as a next-generation multiplexed intelligent biosensing strategy.

  • Wettability-Enhanced Photothermal Vertical Flow Biosensor on a Syringe for PSA Detection Using TaTe 2 Nanosheets

    by Yan Huang, Luyao Feng, Manyan Wu, Xuan Gao, Yongxiang Ji, Ying Liu, Wanli Wang, Tailin Xu, Changyan Sun

    Photothermal vertical flow biosensors (VFBs) have emerged as attractive tools for biomarker detection, addressing restricted sensitivity, insufficient quantitative accuracy, and geometric mismatch issues of traditional photothermal lateral flow biosensors (LFBs) while retaining rapid detection capability. Herein, we developed a syringe-based wettability-enhanced photothermal vertical flow biosensor (SW-PVFB) for prostate-specific antigen (PSA) detection, integrating tantalum ditelluride (TaTe2) nanosheets as highly efficient photothermal probes and hydrophilic/hydrophobic patterned nitrocellulose (NC) membranes for precise fluid control and target enrichment. The 10-20-nm-thick TaTe2 nanosheets exhibited a photothermal conversion efficiency of 50.74% and good stability, efficiently converting near-infrared irradiation to detectable heat signals. The hydrophilic/hydrophobic NC membrane confined fluid flow to the detection zone, enhancing the TaTe2 accumulation and signal intensity. Under optimal conditions, SW-PVFB detected PSA in urine over 0-160 ng mL-1 with a limit of detection (LOD) of 0.028 ng mL-1, significantly outperforming conventional LFBs and standard VFBs. It showed high specificity against interfering proteins (e.g., CA9 and CEA), good reproducibility (RSD ≤ 3.8%), and recoveries of 89.1-112.7% in spiked urine. Integrated with a smartphone for portable signal readout, this SW-PVFB provides a sensitive, user-friendly point-of-care testing (POCT) platform for decentralized PSA diagnostics.


  • CRISPR/Cas13a-driven lateral flow assay for preamplification-free and ultrasensitive miRNA-21 detection

    by Yan Zhu, Junwei Lai, Xinyao Yang, Shuqing Wang, Dayong Gu, Yan Huang, Yizhen Liu, Conghui Liu


  • Double-Enhanced Photothermal Lateral Flow Biosensor Based on Dual Gold Nanoparticle Conjugates

    by Yan Huang, Yongxiang Ji, Mengxin Zheng, Xiujuan Li, Yi Luan, Yang Liu, Xueji Zhang

    Bacterial toxins emerge as the primary triggers of foodborne illnesses, posing a significant threat to human health. To ensure food safety, it is imperative to implement point-of-care testing methods. Lateral flow biosensors (LFBs) based on gold nanoparticles (GNPs) have been commonly used for rapid detection, but their applicationis limited by low sensitivity. Based on the localized surface plasmon resonance and photothermal effect of dual gold nanoparticle conjugates (DGNPs), we developed a smartphone-integrated photothermal LFB (PLFB) with double-enhanced colorimetric and photothermal sensitivity. Through numerical simulations, we verified that DGNPs have significantly enhanced photothermal performance compared to single 15 nm GNPs (SGNPs), and applied DGNPs in PLFB for the detection of staphylococcus enterotoxin A (SEA). The colorimetric and photothermal limits of detection of DGNPs-based PLFB for SEA were 0.091 and 0.0038 ng mL-1, respectively. Compared with the colorimetric detection of the SGNPs-based LFB, the colorimetric detection sensitivity of the DGNPs-based PLFB was increased by 10.7 times, and the photothermal detection sensitivity was further improved by 255.3 times. Moreover, the PLFB exhibits robust reproducibility and exceptional specificity and is applicable for detecting SEA in milk samples. This smartphone-integrated PLFB based on DGNPs allows users to detect toxins simply, conveniently, and quickly and has huge application potential in the field of food safety.


  • Lateral Flow Strip Biosensors for Foodborne Pathogenic Bacteria via Direct and Indirect Sensing Strategies: A Review

    by Yongxiang Ji, Yan Huang, Zhihao Cheng, Wenbin Hao, Guodong Liu, Yang Liu, Xueji Zhang

    Rapid and sensitive detection of foodborne pathogenic bacteria is particularly important for the prevention and control of foodborne diseases. The lateral flow strip biosensor (LFSB) is one of the most promising point-of-care detection tools and has been widely used in food safety monitoring. This review introduces recent advances in the detection of foodborne pathogenic bacteria using LFSBs. According to different bacterial biomarkers, we summarize the direct and indirect sensing strategies of bacterial LFSBs. The direct sensing strategies for whole bacterial cells are divided into antibodies, antibody alternatives, and label-free according to the recognition elements. The indirect sensing strategies refer to the detection of bacterial nucleic acids and metabolites. Next, we compare and discuss the applications of direct and indirect sensing strategies. Finally, the existing challenges, future perspectives, and development directions are discussed, which will facilitate the theoretical innovation and practical application for bacterial LFSBs.


  • Smartphone-Based Photothermal Lateral Flow Immunoassay Using Rhenium Diselenide Nanosheet

    by Wenbin Hao, Yan Huang, Lei Wang, Jing Liang, ShuangShuang Yang, Lei Su, Xueji Zhang

    Developing a rapid antibody-based detection method is of great importance for preventing and controlling the spread of coronavirus disease 2019 (COVID-19). Among the antibody-based methods for point-of-care (POC) detection, lateral flow immunoassay (LFIA) is the most widely used. However, LFIA still has the disadvantage of low sensitivity. In this work, an ReSe2 nanosheet with a thickness of 10-20 nm was prepared by liquid exfoliation and applied as the label in a photothermal LFIA due to its high photothermal conversion efficiency and high photothermal stability. An integrated detection device was introduced for rapid, on-site, and highly sensitive assay of the human antisevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) Spike (S) protein IgG antibodies. The device mainly included a rhenium diselenide (ReSe2) nanosheet-based photothermal LFIA, a portable laser, and a smartphone with a portable thermal imager, which was used to record and analyze the thermal signal of the LFIA test zone. The human anti-SARS-COV-2 S protein IgG antibodies in buffer solution can be detected in a portable box within 10 min, with a thermal signal detection limit of 0.86 ng mL-1, which was 108-fold lower than that of the colorimetric signal. The integrated device can detect values as low as 2.76 ng mL-1 of the human anti-SARS-COV-2 S protein IgG antibodies in 50% serum. The integrated device showed great potential for rapid and home self-testing diagnosis of COVID-19.


  • Ultra-Trace Protein Detection by Integrating Lateral Flow Biosensor with Ultrasound Enrichment

    by Yan Huang, Tailin Xu, Yong Luo, Conghui Liu, Xuan Gao, Zhihao Cheng, Yongqiang Wen, Xueji Zhang

    Lateral flow biosensor (LFB) is one of the most successful and applied commercial detection methods for food safety, drug abuse, and disease. Here, we integrated the ultrasound enrichment as sample preparation with LFB to achieve the ultra-trace protein detection in blood. When the ultrasound field is applied, the interaction between the acoustic field and gold nanoparticles can gather specifically modified gold nanoparticles toward pressure nodes in seconds and enrich target proteins. Such an approach can detect protein with a linear range of 1–20 ng mL–1 and detection limit of 0.58 ng mL–1 in blood within 20 min, which enormously reduces false positive readings caused by interference in real blood samples with complex components. Such a microchip that integrated acoustic enrichment with LFB shows great potential in detecting ultra-trace biomarkers for clinical diagnosis.