Dinank Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dinank Gupta has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Zhen Xu
Department of Biomedical Engineering, University of Michigan, Ann Arbor, USA
3 shared publications Douglas C. Noll
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
2 shared publicationsSteven P. Allen
Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT, USA
2 shared publicationsTimothy L. Hall
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
2 shared publicationsDave Choi
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA
1 shared publication- Douglas C. Noll
Department of Biomedical Engineering University of Michigan Ann Arbor Michigan USA
1 shared publication
Latest Publications
- Open Access
- 7 April 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 665-677
MR‐Cavitation Dynamics Encoded (MR‐CaDE) imaging
Purpose: To develop methods for dynamic cavitation monitoring of a non‐invasive ultrasound mechanical ablation technology (histotripsy) in the brain and test its feasibility for treatment monitoring in ex‐vivo brain in a human MRI scanner. Methods: A Gradient Echo (GRE) pulse sequence was modified with a bipolar gradient to perform MR‐Cavitation Dynamics Encoded (MR‐CaDE) imaging. Cavitation generated by histotripsy sonication was monitored using MR‐CaDE imaging in ex‐vivo bovine brain tissues on a human MRI scanner. Bipolar gradients with a b‐value of and smaller were used while a trigger was sent from the MR scanner to the histotripsy driving electronics. MR acquisition was performed with TE/TR: with 1.5‐cycle histotripsy sonications at 1 pulse/TR. Feasibility of treatment monitoring was also evaluated for histotripsy through an excised human skull. Results: The MR‐CaDE imaging pulse sequence was used to perform treatment monitoring of cavitation generated by histotripsy with a temporal resolution of with a spiral readout. A decrease in the image magnitude and an increase in the phase was observed with an increasing number of histotripsy sonications. The magnitude image exhibited a peak loss of 50%, and the phase image exhibited a maximum increase of 0.64rad compared to the baseline signal level in the brain. The peak signal magnitude change aligned well with the array's geometrical focus, and the post‐histotripsy lesion visualized on a DWI () scan with an alignment error of and in the transverse and longitudinal axes, respectively. The area of the histotripsy response using the spiral readout in the magnitude and phase images were and , respectively. Conclusion: This work demonstrated the feasibility of the MR‐CaDE pulse sequence, which can be used to monitor cavitation events in the brain generated by histotripsy.
- 7 April 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (2) , 665-677
Open AccessMR‐Cavitation Dynamics Encoded (MR‐CaDE) imaging
Purpose: To develop methods for dynamic cavitation monitoring of a non‐invasive ultrasound mechanical ablation technology (histotripsy) in the brain and test its feasibility for treatment monitoring in ex‐vivo brain in a human MRI scanner. Methods: A Gradient Echo (GRE) pulse sequence was modified with a bipolar gradient to perform MR‐Cavitation Dynamics Encoded (MR‐CaDE) imaging. Cavitation generated by histotripsy sonication was monitored using MR‐CaDE imaging in ex‐vivo bovine brain tissues on a human MRI scanner. Bipolar gradients with a b‐value of and smaller were used while a trigger was sent from the MR scanner to the histotripsy driving electronics. MR acquisition was performed with TE/TR: with 1.5‐cycle histotripsy sonications at 1 pulse/TR. Feasibility of treatment monitoring was also evaluated for histotripsy through an excised human skull. Results: The MR‐CaDE imaging pulse sequence was used to perform treatment monitoring of cavitation generated by histotripsy with a temporal resolution of with a spiral readout. A decrease in the image magnitude and an increase in the phase was observed with an increasing number of histotripsy sonications. The magnitude image exhibited a peak loss of 50%, and the phase image exhibited a maximum increase of 0.64rad compared to the baseline signal level in the brain. The peak signal magnitude change aligned well with the array's geometrical focus, and the post‐histotripsy lesion visualized on a DWI () scan with an alignment error of and in the transverse and longitudinal axes, respectively. The area of the histotripsy response using the spiral readout in the magnitude and phase images were and , respectively. Conclusion: This work demonstrated the feasibility of the MR‐CaDE pulse sequence, which can be used to monitor cavitation events in the brain generated by histotripsy.
- Open Access
- 25 November 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (2) , 330-335
Transcranial MRI-guided Histotripsy Targeting Using MR-thermometry and MR-ARFI
- 25 November 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 51 (2) , 330-335
Open AccessTranscranial MRI-guided Histotripsy Targeting Using MR-thermometry and MR-ARFI
- 19 February 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (5) , 1102-1107
Magnetic Resonance Thermometry Targeting for Magnetic Resonance–Guided Histotripsy Treatments
- 19 February 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (5) , 1102-1107
Magnetic Resonance Thermometry Targeting for Magnetic Resonance–Guided Histotripsy Treatments
- Open Access
- 25 September 2019
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 9, 964
Generation of Synthetic CT Images From MRI for Treatment Planning and Patient Positioning Using a 3-Channel U-Net Trained on Sagittal Images
A novel deep learning architecture was explored to create synthetic CT (MRCT) images that preserve soft tissue contrast necessary for support of patient positioning in Radiation therapy. A U-Net architecture was applied to learn the correspondence between input T1-weighted MRI and spatially aligned corresponding CT images. The network was trained on sagittal images, taking advantage of the left-right symmetry of the brain to increase the amount of training data for similar anatomic positions. The output CT images were divided into three channels, representing Hounsfield Unit (HU) ranges of voxels containing air, soft tissue, and bone, respectively, and simultaneously trained using a combined Mean Absolute Error (MAE) and Mean Squared Error (MSE) loss function equally weighted for each channel. Training on 9192 image pairs yielded resulting synthetic CT images on 13 test patients with MAE of 17.6+/−3.4 HU (range 14–26.5 HU) in soft tissue. Varying the amount of training data demonstrated a general decrease in MAE values with more data, with the lack of a plateau indicating that additional training data could further improve correspondence between MRCT and CT tissue intensities. Treatment plans optimized on MRCT-derived density grids using this network for 7 radiosurgical targets had doses recalculated using the corresponding CT-derived density grids, yielding a systematic mean target dose difference of 2.3% due to the lack of the immobilization mask on the MRCT images, and a standard deviation of 0.1%, indicating the consistency of this correctable difference. Alignment of MRCT and cone beam CT (CBCT) images used for patient positioning demonstrated excellent preservation of dominant soft tissue features, and alignment comparisons of treatment planning CT scans to CBCT images vs. MRCT to CBCT alignment demonstrated differences of −0.1 (σ 0.2) mm, −0.1 (σ 0.3) mm, and −0.2 (σ 0.3) mm about the left-right, anterior-posterior and cranial-caudal axes, respectively.
- 25 September 2019
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 9, 964
Open AccessGeneration of Synthetic CT Images From MRI for Treatment Planning and Patient Positioning Using a 3-Channel U-Net Trained on Sagittal Images
A novel deep learning architecture was explored to create synthetic CT (MRCT) images that preserve soft tissue contrast necessary for support of patient positioning in Radiation therapy. A U-Net architecture was applied to learn the correspondence between input T1-weighted MRI and spatially aligned corresponding CT images. The network was trained on sagittal images, taking advantage of the left-right symmetry of the brain to increase the amount of training data for similar anatomic positions. The output CT images were divided into three channels, representing Hounsfield Unit (HU) ranges of voxels containing air, soft tissue, and bone, respectively, and simultaneously trained using a combined Mean Absolute Error (MAE) and Mean Squared Error (MSE) loss function equally weighted for each channel. Training on 9192 image pairs yielded resulting synthetic CT images on 13 test patients with MAE of 17.6+/−3.4 HU (range 14–26.5 HU) in soft tissue. Varying the amount of training data demonstrated a general decrease in MAE values with more data, with the lack of a plateau indicating that additional training data could further improve correspondence between MRCT and CT tissue intensities. Treatment plans optimized on MRCT-derived density grids using this network for 7 radiosurgical targets had doses recalculated using the corresponding CT-derived density grids, yielding a systematic mean target dose difference of 2.3% due to the lack of the immobilization mask on the MRCT images, and a standard deviation of 0.1%, indicating the consistency of this correctable difference. Alignment of MRCT and cone beam CT (CBCT) images used for patient positioning demonstrated excellent preservation of dominant soft tissue features, and alignment comparisons of treatment planning CT scans to CBCT images vs. MRCT to CBCT alignment demonstrated differences of −0.1 (σ 0.2) mm, −0.1 (σ 0.3) mm, and −0.2 (σ 0.3) mm about the left-right, anterior-posterior and cranial-caudal axes, respectively.