GTGüldane Oku Topal

Güldane Oku Topal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Güldane Oku Topal has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determining the performance of HR-GNSS and RTS geodetic techniques for Structural Health Monitoring

    by Güldane Oku Topal, Burak Akpınar

    This study investigates the effectiveness of geodetic methods in Structural Health Monitoring (SHM), focusing on the utilization of the High-Rate Global Navigation Satellite System (HR-GNSS) and Robotic Total Station (RTS) for monitoring structural movements. Experiments were conducted on a horizontal single-axis shake table to simulate various frequencies and amplitudes. Data were analyzed using time series and Fast Fourier Transform (FFT) techniques to evaluate the performance of geodetic measurement methods in SHM studies Two applications were conducted using a single-axis shake table. In the first, the table oscillated at 0.25 Hz frequency and 20 mm amplitude, while data from a GNSS receiver on the upper table underwent processing with the TRACK module of GAMIT/GLOBK software using the kinematic post-process (KPP) GNSS technique. In the second, the reflector on the shake table moved through eight oscillations at various amplitudes and frequencies, monitored automatically with a LEICA TPS1200 RTS. Time series and FFT analyses were performed on all application data to determine oscillation frequencies and amplitudes. Method accuracy was assessed by comparing these values with data from the shake table’s high-precision position sensor (Linear Variable Differential Transformer-LVDT). Results showed good agreement between HR-GNSS measurements and LVDT data, with a -1.6mm amplitude difference for KPP GNSS. Additionally, RTS measurements accurately determined frequency values, with amplitude differences ranging from 0.2 mm to 6.5 mm. Root Mean Square Error (RMSE) values for eight RTS tests, covering frequencies between 0.25-0.50 Hz and amplitudes between 4.5-73.4 mm, varied from 2.1mm to 6.3mm, reflecting performance variability across different conditions.


  • Open Access

    Filtering Low-Cost GNSS Measurements to Determine Structural Behaviors: The Case of Davutpaşa Pedestrian Bridge

    by Güldane Oku Topal, Burak Akpinar

    This study investigates the dynamic responses of the Davutpaşa Pedestrian Bridge to pedestrian loads using low-cost and high-cost Global Navigation Satellite Systems (GNSS) along with accelerometers. Traditionally, expensive dual-frequency GNSS receivers were employed for structural monitoring, but recent advancements in low-cost GNSS technology have provided a cost-effective alternative. The study employs signal filtering techniques and Fast Fourier Transform (FFT) to analyse datasets in time and frequency domains. Specifically, the Yule-Walker Design of Infinite Impulse Response (IIR) Band-pass Filter is applied to GNSS measurements to reveal natural frequencies obscured by noise. The accuracy was assessed by comparing frequency values obtained through full-scale monitoring with those from a Finite Element (FE) model. After filtering analysis, it has been determined that the natural frequencies obtained from geodetic GNSS agree with accelerometer frequencies with a maximum difference of 0.12 Hz (3%). In low-cost GNSS receivers, for the A10 antenna, a maximum difference of 0.09 Hz (3%), and for the UBX antenna, a maximum difference of 0.10 Hz (3%) has been obtained, showing compatibility with the accelerometer. As a result, it has been found that with appropriate filtering techniques and selecting sampling intervals suitable for structural dynamics, even rigid structures like pedestrian bridges can have their natural frequencies determined using geodetic equipment.


  • Performance of Low-Cost GNSS in Structural Health Monitoring Studies: Shake Table Tests

    by G. Oku Topal, B. Akpınar, M. F. Karabulut, N. O. Aykut, C. O. Yigit, A. A. Dindar, B. Doran, M. Bezcioglu, A. Zafer, Z. B. Cakmak


  • Performance of low-cost GNSS equipment in monitoring of horizontal displacements

    by Güldane Oku Topal, Mustafa Fahri Karabulut, Nedim Onur Aykut, Burak Akpınar

    To investigate theperformance of low-cost GNSS equipment in monitoring horizontal displacements ANN-MB-GNSS and A10 antenna were installed on Zeiss-BRT-006 reduktionstachymeter, which can move with mm sensitivity in the horizontal plane. Ten days of static data were recorded with U-Blox-ZED-F9P-02B-GNSS receiver and processed with CSRS-PPP online-service. Considering theobservation period(12,6,3,1h), nine horizontal displacement magnitude tests were performed.Inaddition, GNSS-PPPAR solution percentages, multipath and signal-to-noise ratio values were considered. The results reveal that 20mm displacement can be determined (6mmRMSE) using the PPP approach based on a 3-hour observation period with A10antenna and 30mm can be determined (15mmRMSE) with UBX antenna with a 6-hour observation.


  • The positioning performance of low-cost GNSS receivers in the Precise Point Positioning method

    by Mustafa Fahri Karabulut, Nedim Onur Aykut, Burak Akpınar, Güldane Oku Topal, Zübeyir Bilal Çakmak, Bilge Doran, Ahmet Anıl Dindar, Cemal Özer Yiğit, Mert Bezcioğlu, Anıl Zafer

    Satellite-based positioning, which started being developed in the mid-1960s for military purposes, is now used in almost every area. For the studies single and/or double frequency receivers are used. The cost of a receiver and antenna couple that have capable of high coordinate accuracies ranges from $3000 to $15000. With the production of Original Equipment Manufacturer (OEM) receivers, the cost of satellite-based location determination decreases to approximately one in 10 for the civilian user compared to the operations performed with geodetic receivers and antennas. However, although these receivers collect data in multi-Global Navigation Satellite System (GNSS) and frequencies, the accuracy of the coordinate values estimated is not as high as geodetic receivers and antennas. Therefore, it is necessary to carry out an accuracy study to obtain information about which studies can be used in. In this study, measurements were made at the UZEL point located on the roof of the Yıldız Technical University Geomatics Engineering Department by using the ZED-F9P-02B OEM multi GNSS receiver and ANN-MB L1/L2 multi-band GNSS patch antenna. The performance of the test results has been examined by comparing the results from CSRS(Canadian Spatial Reference System)-PPP with the coordinates of the UZEL point. As a result of the comparison, the difference between the coordinate determined with collected 3.5 hr data and the coordinates of the UZEL point has been determined as – 1.4 cm, 2.8 cm, and 9.3 cm in the East, North, and Height directions, respectively


  • The efficiency of single base and network RTK for Structural Health Monitoring

    by Güldane Oku Topal, Burak Akpinar

    With the developing technology and increasing construction, the importance of structural observations, which are of great significance in disaster management, has increased. Geodetic methods have been preferred in recent years due to their high accuracy and ease of use in Structural Health Monitoring (SHM) Surveys. In this study, harmonic oscillation tests have been carried out on a shake table to determine the usability of the Single Base and the Network Real-Time Kinematic (RTK) Global Navigation Satellite Systems (GNSS) method in SHM studies. It is aimed to determine the harmonic movements of different amplitudes and frequencies created by the shake table with 20 Hz multi-GNSS equipment. The amplitude and frequency values of the movements created using Fast Fourier Transform (FFT) and Time Series Analysis have been calculated. The precision of the analysis results has been determined by comparing the LVDT (Linear Variable Differential Transformer) data, which is the position sensor of the shake table, with the GNSS data. The advantages of the two RTK methods over each other have been determined using the calculated amplitude and frequency differences. As a result of all experiments, it has been determined that network and single base RTK GNSS methods effectively monitor structural behaviours and natural frequencies.