JDJie Ding

Jie Ding

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jie Ding has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Verifying calculated dose to the breast in stereotactic radiotherapy: A practical phantom‐based method

    by Stewart J. Becker, Ryan E. Smith, Wesley S. Culberson, Kurt E. Stump, Baoshe Zhang, Jie Ding, Sina Mossahebi, Dennis Herschbach, Elizabeth M. Nichols

    Background: Reference dosimetry for the GammaPod breast radiosurgery device is determined in a polymethyl methacrylate (PMMA) phantom, while the clinical dose calculations assume the patient's breast has the atomic composition of water with a density (∼0.935 g/cm 3 ). Direct measurement within this clinical breast‐tissue equivalent material is desirable to validate the treatment planning system (TPS) with end‐to‐end testing and patient‐specific quality assurance (PSQA). Purpose: This study aimed to validate the GammaPod TPS dose calculations by 3D printing a breast‐equivalent phantom and to develop a practical and reproducible method for end‐to‐end testing and PSQA. Methods: Multiple breast‐shaped phantoms matching the L02 GammaPod cup geometry were fabricated; three using 3D printing and one using clear ice. The 3D‐printed phantoms were constructed from polylactic acid (PLA) and premium PLA (PLApro) using optimized infill densities to achieve a physical density near 0.935 g/cm 3 , matching the TPS's breast‐tissue model. These infills were determined by creating series of CT phantom plugs and choosing the ones with the closest Hounsfield units (HUs) and stopping power ratios (SPRs) to the TPS breast tissue model. A rotating insert design allowed multi‐position measurements with an Exradin A1SL ionization chamber and thermoluminescent dosimeters (TLDs). CT imaging and dosimetry were performed following the clinical GammaPod workflow. An ice phantom, with a density of approximately 0.918 g/cm 3 , served as an independent validation reference. Measured doses were compared with TPS‐calculated doses. Results: The breast‐tissue mimicking phantoms yielded mean Hounsfield (HU) and Stopping Power Ratios (SPR) numbers of −81 HU ± 5 and 0.99 SPR for blue PLApro (92.5%), −69 HU ± 11 and 0.99 SPR for natural PLA (86.0%), −82 HU ± 5 and 1.00 SPR for the ice phantom corresponding to densities of 0.916 g/cm 3 , 0.928 g/cm 3 , and 0.915 g/cm 3 respectively, comparable to the modeled breast tissue. Measured‐to‐calculated dose differences for the ice phantom were within ± 0.5%, while the 3D printed phantoms had an average difference of 1.2%, consistent with published dosimetric uncertainty limits of the GammaPod. The total estimated measurement uncertainty, including charge‐to‐dose conversion and material variability, was 1.7%. The 3D‐printed phantoms demonstrated excellent reproducibility when printing parameters were held constant. Conclusion: The GammaPod TPS accurately predicts dose in breast‐equivalent materials. The 3D‐printed breast phantom provides a reliable, water‐composition breast‐density material, and geometrically accurate tool for end‐to‐end testing and PSQA, eliminating the challenges associated with water measurements. This method supports routine clinical verification and offers a reproducible framework for ongoing GammaPod QA and commissioning.

  • Open Access

    Reinforcement learning-guided segment anything model for MRI prostate and dominant intraprostatic lesions auto-segmentation

    by Jingchu Chen, Mingzhe Hu, Mojtaba Safari, Ryan James Sanford, Jie Ding, Beth Ghavidel, Eric Elder, Justin Roper, Richard L J Qiu, Xiaofeng Yang

    Objective Accurate segmentation of the prostate and dominant intraprostatic lesions (DILs) on magnetic resonance imaging (MRI) is important for prostate cancer radiation therapy treatment planning and targeted dose escalation. However, DIL segmentation remains challenging due to small datasets, institutional bias, and variable imaging protocols. Although the Segment Anything Model (SAM) has shown promise in medical image segmentation, most prior work depends on manual prompts. This study developed a fully automated pipeline that combines localization with a fine-tuned SAM model to segment the prostate and DIL. Approach Two datasets were utilized: the PI-CAI dataset, comprising 1,476 patients, and the Cancer Imaging Archive dataset, comprising 803 patients. The pipeline consisted of two stages: (1) a reinforcement learning-based localization network predicted bounding boxes as segmentation inputs, and (2) a fine-tuned SAM model performed segmentation. Model performance was evaluated using the Dice Similarity Coefficient (DSC), Intersection over Union (IoU), and detection rates, with additional analysis based on lesion volumes. Main Results The proposed method achieved a mean and median DSC of 0.896±0.070 and 0.915, and an IoU of 0.818±0.100 and 0.844 for prostate segmentation. For DIL segmentation, the mean and median DSC were 0.592±0.192 and 0.636, IoU of 0.446±0.190 and 0.466, with a detection rate of 89%. Four DIL groups were created based on lesion volume percentile. The mean/median DSC and IoU for each volume group is as follows: 0.5–1.0 cubic centimeters (cc): 0.555±0.201/0.562 & 0.414±0.205/0.391; 1.0-1.8 cc: 0.603±0.185/0.660 & 0.454±0.180/0.492; 1.8-4.0 cc: 0.588±0.183/0.627 & 0.439±0.174/0.456; >4.0 cc: 0.621±0.197/0.669 & 0.477±0.197/0.503. Significance This study presented a fully automated prostate and DIL segmentation framework on MRI by integrating a localization network with fine-tuned SAM. The method achieved robust performance across large multi-institutional datasets and diverse lesion shapes. It shows strong potential for application to clinical workflows for prostate cancer radiation therapy planning and treatment.


  • Open Access

    An efficient 3D latent diffusion model for T1-contrast enhanced MRI generation

    by Zach Eidex, Mojtaba Safari, Jie Ding, Richard L J Qiu, Justin Roper, David S Yu, Hui-Kuo Shu, Zhen Tian, Hui Mao, Xiaofeng Yang

    Gadolinium-based contrast agents (GBCAs) are commonly employed with T1-weighted (T1w) MRI to enhance lesion visualization but are restricted in patients at risk of nephrogenic systemic fibrosis. In addition, variations in GBCA administration can introduce imaging inconsistencies. This study develops an efficient 3D deep-learning framework to generate T1-contrast enhanced images (T1C) from pre-contrast multiparametric MRI. We propose the 3D latent rectified flow (T1C-RFlow) model for generating high-quality T1C images. First, T1w and T2-FLAIR images are input into a pretrained autoencoder to acquire an efficient latent space representation. A rectified flow diffusion model is then trained in this latent space representation. The T1C-RFlow model was trained on a curated dataset comprised of the Brain Tumor Segmentation (BraTS) 2024 glioma (GLI; 1480 patients), meningioma (MEN; 1141 patients), and metastases (MET; 1475 patients) datasets. Selected patients were split into training (N = 2860), test (N = 614), and validation (N = 612) sets. Model performance was evaluated with the normalized mean squared error (NMSE) and structural similarity index measure (SSIM). Both qualitative and quantitative results demonstrate that the T1C-RFlow model outperforms benchmark 3D models (pix2pix, denoising diffusion probability models (DDPM), Diffusion Transformers (DiT-3D) trained in the same latent space. T1C-RFlow achieved the following metrics - GLI: NMSE 0.044 ± 0.047, SSIM 0.935 ± 0.025; MEN: NMSE 0.046 ± 0.029, SSIM 0.937 ± 0.021; MET: NMSE 0.098 ± 0.088, SSIM 0.905 ± 0.082. In a blinded reader study of 15 patients (5 GLI, 5 MEN, 5 MET), T1C-RFlow received the highest diagnostic-quality scores across all tumor types (3.80 ± 0.45, 3.20 ± 0.45, and 2.60 ± 0.89 on a 5-point Likert scale), significantly outperforming all baseline methods (p < .05). Further studies showed T1C-RFlow to have the best tumor reconstruction performance and significantly faster denoising times (6.9 s volume −1 , 200 steps) than conventional DDPM models in both latent space (37.7 s, 1000 steps) and patch-based in image space (4.3 h volume −1 ). Our proposed method generates synthetic T1C images that closely resemble radiological features of ground truth T1C in much less time than previous diffusion models. Further development may permit a practical method for contrast-agent-free MRI for brain tumors. Code is made available at https://github.com/zacheidex/An-Efficient-3D-Latent-Diffusion-Model-for-T1-contrast-Enhanced-MRI-Generation.


  • Open Access

    Evaluation of a prostate SBRT planning workflow using auto‐segmentation and knowledge‐based planning

    by Trisha Jones, Kirk Luca, Mingdong Fan, Pretesh R. Patel, Ashesh B. Jani, Xiaofeng Yang, Justin Roper, Jie Ding

    Purpose: This study investigates a prostate stereotactic body radiotherapy (SBRT) planning workflow integrating commercial artificial intelligence (AI) contouring and knowledge‐based planning (KBP). The purpose is to determine whether AI‐generated contours are comparable to physician‐delineated contours in achieving dosimetric goals. Methods: In this retrospective study, 20 patients with intact prostate cancer were included. A commercial AI contouring software was applied to computed tomography (CT) scans. Contouring accuracy for the prostate, rectum, and bladder was assessed against clinical contours using geometric metrics including Dice similarity coefficient (DSC), surface DSC (sDSC), and added path length (APL). Volumetric modulated arc therapy plans were generated using an in‐house prostate SBRT KBP model without user interaction. The prescribed dose was 36.25 Gy in 5 fractions to the planning target volume with a 40 Gy simultaneous integrated boost to the prostate. All plans were calculated using AcurosXB and normalized to cover 98% of the prostate. Given the high precision required for prostate SBRT, all plans used the physician‐delineated (clinical) prostate contours. Three plans were generated for each patient: (1) a reference plan using clinical contours, (2) a plan using clinical prostate contour and AI organs at risk (OARs), and (3) a plan using clinical prostate contour and post‐processed AI OARs that removed any overlap with the clinical prostate contour. The latter two plans were recalculated on clinical contours with fixed monitor units to evaluate the dosimetric impact of AI contouring. Plan quality was evaluated using NRG‐GU013 criteria. Results: The average DSC values were 0.83, 0.86, and 0.94 for prostate, rectum, and bladder, respectively, and the average sDSC values were 0.62, 0.81, and 0.85. AI prostate contours were clinically unacceptable. AI rectum and bladder contours overlapped the clinical prostate contour in 15 and 20 cases, respectively. All reference plans using clinical contours met NRG criteria. Using AI OARs or post‐processed AI OARs, only one case exceeded rectum V36Gy limits due to over‐contouring, but it became clinically acceptable after recalculation on clinical contours. Plans using post‐processed AI OARs yielded dosimetric results more comparable to reference plans for rectum and bladder sparing. Conclusions: This study investigates a prostate SBRT treatment planning workflow by leveraging AI contouring and KBP. Although a fully automated workflow is not yet feasible, results are encouraging when physician‐delineated target volumes are combined with post‐processed AI contours.


  • Deep learning based automatic contour refinement for inaccurate auto-segmentation in MR-guided adaptive radiotherapy

    by Jie Ding, Ying Zhang, Asma Amjad, Christina Sarosiek, Nguyen Phuong Dang, Mohammad Zarenia, X Allen Li

    Objective. Fast and accurate auto-segmentation is essential for magnetic resonance-guided adaptive radiation therapy (MRgART). Deep learning auto-segmentation (DLAS) is not always clinically acceptable, particularly for complex abdominal organs. We previously reported an automatic contour refinement (ACR) solution of using an active contour model (ACM) to partially correct the DLAS contours. This study aims to develop a DL-based ACR model to work in conjunction with ACM-ACR to further improve the contour accuracy. Approach. The DL-ACR model was trained and tested using bowel contours created by an in-house DLAS system from 160 MR sets (76 from MR-simulation and 84 from MR-Linac). The contours were classified into acceptable, minor-error and major-error groups using two approaches of contour quality classification (CQC), based on the AAPM TG-132 recommendation and an in-house classification model, respectively. For the major-error group, DL-ACR was applied subsequently after ACM-ACR to further refine the contours. For the minor-error group, contours were directly corrected by DL-ACR without applying an initial ACM-ACR. The ACR workflow was performed separately for the two CQC methods and was evaluated using contours from 25 image sets as independent testing data. Main results. The best ACR performance was observed in the MR-simulation testing set using CQC by TG-132: (1) for the major-error group, 44% (177/401) were improved to minor-error group and 5% (22/401) became acceptable by applying ACM-ACR; among these 177 contours that shifted from major-error to minor-error with ACM-ACR, DL-ACR further refined 49% (87/177) to acceptable; and overall, 36% (145/401) were improved to minor-error contours, and 30% (119/401) became acceptable after sequentially applying ACM-ACR and DL-ACR; (2) for the minor-error group, 43% (320/750) were improved to acceptable contours using DL-ACR. Significance. The obtained ACR workflow substantially improves the accuracy of DLAS bowel contours, minimizing the manual editing time and accelerating the segmentation process of MRgART.


  • Open Access

    Preoperative prediction of lymph node metastasis using deep learning-based features

    by Renee Cattell, Jia Ying, Lan Lei, Jie Ding, Shenglan Chen, Mario Serrano Sosa, Chuan Huang

    Lymph node involvement increases the risk of breast cancer recurrence. An accurate non-invasive assessment of nodal involvement is valuable in cancer staging, surgical risk, and cost savings. Radiomics has been proposed to pre-operatively predict sentinel lymph node (SLN) status; however, radiomic models are known to be sensitive to acquisition parameters. The purpose of this study was to develop a prediction model for preoperative prediction of SLN metastasis using deep learning-based (DLB) features and compare its predictive performance to state-of-the-art radiomics. Specifically, this study aimed to compare the generalizability of radiomics vs DLB features in an independent test set with dissimilar resolution. Dynamic contrast-enhancement images from 198 patients (67 positive SLNs) were used in this study. Of these subjects, 163 had an in-plane resolution of 0.7 × 0.7 mm2, which were randomly divided into a training set (approximately 67%) and a validation set (approximately 33%). The remaining 35 subjects with a different in-plane resolution (0.78 × 0.78 mm2) were treated as independent testing set for generalizability. Two methods were employed: (1) conventional radiomics (CR), and (2) DLB features which replaced hand-curated features with pre-trained VGG-16 features. The threshold determined using the training set was applied to the independent validation and testing dataset. Same feature reduction, feature selection, model creation procedures were used for both approaches. In the validation set (same resolution as training), the DLB model outperformed the CR model (accuracy 83% vs 80%). Furthermore, in the independent testing set of the dissimilar resolution, the DLB model performed markedly better than the CR model (accuracy 77% vs 71%). The predictive performance of the DLB model outperformed the CR model for this task. More interestingly, these improvements were seen particularly in the independent testing set of dissimilar resolution. This could indicate that DLB features can ultimately result in a more generalizable model.


  • Ultrasound-based radiomics score: a potential biomarker for the prediction of progression-free survival in ovarian epithelial cancer

    by Fei Yao, Jie Ding, Zhangyong Hu, Mengting Cai, Jinjin Liu, Xiaowan Huang, Ruru Zheng, Feng Lin, Li Lan

    Purpose More than 80% of patients with ovarian epithelial cancer (OEC) show complete remission after initial treatment but eventually experience recurrence of the disease. This study aimed to develop a radiomics signature to identify a new prognostic indicator based on preoperative ultrasound imaging. Methods A total of 111 patients with OEC who underwent transvaginal ultrasound before surgery were included. Of these, 76 were divided into the training cohort and 35 into the test cohort. We defined the region of interest (ROI) of the tumor by manually drawing the tumor contour on the ultrasound image of the lesion. The radiomics features were extracted from ultrasound images. The radiomics score (Rad-Score) was constructed using the least absolute shrinkage and selection operator (LASSO) analysis and Cox regression. Combined with the ultrasound radiomics features, significant clinical variables were also used to establish predictive models for 5-year progression-free survival (PFS) prediction. The efficiency of the model was evaluated using the area under the curve (AUC). Kaplan–Meier analysis was used to evaluate the association between the Rad-Score and PFS. Results The combined model was superior to the clinical and Rad-Score models in estimating 5-year PFS and achieved an AUC of 0.868 (95%CI 0.766–0.971) in the training cohort. The Rad-Score was negatively correlated with prognosis in the training and test cohorts. Conclusions The combined model that incorporated both clinical parameters and ultrasound radiomics features achieved a good prognosis in patients with OEC, which might aid clinical decision-making.