Jeremy Guillermin
Jeremy Guillermin has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Julien Mekki
Centre National dEtudes Spatiales (CNES), Toulouse, France
4 shared publications - Adriana Morana
Université Jean Monnet Saint-Etienne
3 shared publications - Aziz Boukenter
Laboratoire Hubert Curien, UMR CNRS 5516, Université Jean Monnet, 42000 Saint-Etienne, France
3 shared publications - Bruno Capoen
CNRS, UMR 8523 Physique des Laser Atomes et Molcules (PhLAM), Universit de Lille, Lille, France
3 shared publications - Hicham El Hamzaoui
CNRS, UMR 8523-PhLAM-Physique des Lasers Atomes et Molcules, Univ. Lille, Lille, France
3 shared publications - Marine Aubry
TRAD Tests and Radiations, Labge, France
3 shared publications
Latest Publications
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2306-2312
Optimization of Radioluminescent Fiber Dosimeter for Space Missions
This study investigates the impact of pre-irradiation on radiation-induced luminescence (RIL) based optical fiber dosimeters and compares the performances of Copper (Cu)-, Cerium (Ce)- and Cu/Ce-co-doped silica optical fibers under ionizing radiations. A total of 112 optical fiber probes were tested under 40 keV mean energy fluence X-rays over a wide dose rate range (5 mGy/s to 1.5 Gy/s) after different levels of pre-irradiation treatments (up to 2 MGy). Spectral analyses were also conducted to study the impact of total ionizing dose (TID) on spectral emission profiles. Results show that the pre-irradiation improves the RIL linearity with the dose rate, particularly for Cu-doped optical fibers. Cu/Ce-co-doped optical fibers show higher radiation sensitivity but also a greater probe-to-probe dispersion. However, this latter remains below 30% for all the investigated samples. Normalized RIL spectra show that Ce-doped optical fibers maintain a stable emission spectrum with increasing dose, while Cu- and Cu/Ce-co-doped optical fibers show spectral changes, through a blue shift of the RIL peak. These results underline the benefit of pre-irradiating the radioluminescent optical fibers to optimize their RIL dosimetry performances. For the most challenging applications, an individual calibration remains today needed for accurate dosimetry.
- 2 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (6) , 2306-2312
Optimization of Radioluminescent Fiber Dosimeter for Space Missions
This study investigates the impact of pre-irradiation on radiation-induced luminescence (RIL) based optical fiber dosimeters and compares the performances of Copper (Cu)-, Cerium (Ce)- and Cu/Ce-co-doped silica optical fibers under ionizing radiations. A total of 112 optical fiber probes were tested under 40 keV mean energy fluence X-rays over a wide dose rate range (5 mGy/s to 1.5 Gy/s) after different levels of pre-irradiation treatments (up to 2 MGy). Spectral analyses were also conducted to study the impact of total ionizing dose (TID) on spectral emission profiles. Results show that the pre-irradiation improves the RIL linearity with the dose rate, particularly for Cu-doped optical fibers. Cu/Ce-co-doped optical fibers show higher radiation sensitivity but also a greater probe-to-probe dispersion. However, this latter remains below 30% for all the investigated samples. Normalized RIL spectra show that Ce-doped optical fibers maintain a stable emission spectrum with increasing dose, while Cu- and Cu/Ce-co-doped optical fibers show spectral changes, through a blue shift of the RIL peak. These results underline the benefit of pre-irradiating the radioluminescent optical fibers to optimize their RIL dosimetry performances. For the most challenging applications, an individual calibration remains today needed for accurate dosimetry.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15065-15070
Temperature Impact on a Radioluminescent Silica-Based Optical Fiber Dosimeter for Space Applications
Dosimetry holds significant importance across various applications such as radiotherapy, nuclear power plants, accelerators, and space research domains. Indeed, ensuring accurate dosimetry calibration is crucial for radioprotection or operations. In the context of challenging environments such as space, temperature calibration of radiation sensors plays an important role in ensuring their performances. This article discusses the temperature calibration of a cerium (Ce)-doped silica (SiO2)-based Optical Fiber (OF). The calibration covers a temperature range, during 40 keV X-rays irradiation, varying from - 80 °C to +100 °C, meeting the requirements for space applications and allowing for the determination of the temperature dependence of the Radiation Induced Luminescence (RIL). The tests were repeated on three identical 1 cm-long Ce-doped OFs. Our experiments reveal a temperature dependence of the RIL, particularly noticeable at low temperatures, where RIL decreases significantly as the temperature drops. Consequently, a temperature sensitivity curve for RIL is proposed, to calibrate the variations in RIL responses across the investigated temperature range. However, in complex operation conditions, with varying dose rates and temperatures, other phenomena could alter the detector performances, in particular the thermoluminescence observed during strong positive temperature gradients. This work contributes to highlight the potential of RIL-based sensors under varying temperature conditions, crucial for improving the reliability and accuracy, especially in a harsh environment as space.
- 17 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15065-15070
Temperature Impact on a Radioluminescent Silica-Based Optical Fiber Dosimeter for Space Applications
Dosimetry holds significant importance across various applications such as radiotherapy, nuclear power plants, accelerators, and space research domains. Indeed, ensuring accurate dosimetry calibration is crucial for radioprotection or operations. In the context of challenging environments such as space, temperature calibration of radiation sensors plays an important role in ensuring their performances. This article discusses the temperature calibration of a cerium (Ce)-doped silica (SiO2)-based Optical Fiber (OF). The calibration covers a temperature range, during 40 keV X-rays irradiation, varying from - 80 °C to +100 °C, meeting the requirements for space applications and allowing for the determination of the temperature dependence of the Radiation Induced Luminescence (RIL). The tests were repeated on three identical 1 cm-long Ce-doped OFs. Our experiments reveal a temperature dependence of the RIL, particularly noticeable at low temperatures, where RIL decreases significantly as the temperature drops. Consequently, a temperature sensitivity curve for RIL is proposed, to calibrate the variations in RIL responses across the investigated temperature range. However, in complex operation conditions, with varying dose rates and temperatures, other phenomena could alter the detector performances, in particular the thermoluminescence observed during strong positive temperature gradients. This work contributes to highlight the potential of RIL-based sensors under varying temperature conditions, crucial for improving the reliability and accuracy, especially in a harsh environment as space.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2480-2489
Investigation of the Limits of the Ray-Tracing Method Applied on Dose Analysis for Radiation Hardness Assurance
Radiation hardness assurance (RHA) is critical for a space project as it ensures that electronics will perform to their design specifications during exposure to the mission’s radiation environment. The ray-tracing method (or sector analysis) is commonly used by radiation engineers to estimate the dose at electronic component level, however it relies on specific hypotheses. In this paper, the limits of the ray-tracing method are investigated to understand how the method can be improved and to propose recommendations for the dose calculation. As a first step, the impact of the shielding sectoring resolution is explored and the results are compared to the recommendations of the ECSS-E-ST-10-12C. The second part of the paper investigates the influence of the shielding material on the dose curve computation, the main input of the ray-tracing calculation. Finally, the role of the spacing between different materials as well as the distribution of materials along the particle path is explored.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2480-2489
Investigation of the Limits of the Ray-Tracing Method Applied on Dose Analysis for Radiation Hardness Assurance
Radiation hardness assurance (RHA) is critical for a space project as it ensures that electronics will perform to their design specifications during exposure to the mission’s radiation environment. The ray-tracing method (or sector analysis) is commonly used by radiation engineers to estimate the dose at electronic component level, however it relies on specific hypotheses. In this paper, the limits of the ray-tracing method are investigated to understand how the method can be improved and to propose recommendations for the dose calculation. As a first step, the impact of the shielding sectoring resolution is explored and the results are compared to the recommendations of the ECSS-E-ST-10-12C. The second part of the paper investigates the influence of the shielding material on the dose curve computation, the main input of the ray-tracing calculation. Finally, the role of the spacing between different materials as well as the distribution of materials along the particle path is explored.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1699-1706
Proposal of a Multiscale High Accuracy Engineering Approach for Single-Event Effects Analysis in Modern Technologies
Standard Heavy-Ion Single Event Rate estimation methods are well adapted to mature technologies used in the space industry. However, the adoption of 3D structures as well as advanced technology nodes may reduce the confidence in established rate estimation methods such as IRPP. In this work, an SEE rate calculation method with a GEANT4 based Monte-Carlo approach was designed in order to address this shortcoming. It is intended as an extension to the IRPP method in the context of advanced technologies in the space industry. This paper presents the general concepts and theory behind this approach, as well as results from validation cases based on flight data.
- 11 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (8) , 1699-1706
Proposal of a Multiscale High Accuracy Engineering Approach for Single-Event Effects Analysis in Modern Technologies
Standard Heavy-Ion Single Event Rate estimation methods are well adapted to mature technologies used in the space industry. However, the adoption of 3D structures as well as advanced technology nodes may reduce the confidence in established rate estimation methods such as IRPP. In this work, an SEE rate calculation method with a GEANT4 based Monte-Carlo approach was designed in order to address this shortcoming. It is intended as an extension to the IRPP method in the context of advanced technologies in the space industry. This paper presents the general concepts and theory behind this approach, as well as results from validation cases based on flight data.
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1451-1458
Multiphoton Absorption in Gallium Nitride and Silicon Carbide Photodiodes: Applications for Single-Event Effects Tests
We report on the investigation of multiphoton absorption processes in gallium nitride and silicon carbide photodiodes. Up to three-photon absorption mechanisms were evidenced on both materials, thanks to a wavelength-tunable femtosecond laser chain. These results are applied to single event effect investigations on a commercial gallium nitride high electron mobility transistor. We could trigger single event transients by focusing the beam throughout the silicon substrate and collect charge that was photogenerated in the gallium nitride layer by a three-photon absorption process.
- 18 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (7) , 1451-1458
Multiphoton Absorption in Gallium Nitride and Silicon Carbide Photodiodes: Applications for Single-Event Effects Tests
We report on the investigation of multiphoton absorption processes in gallium nitride and silicon carbide photodiodes. Up to three-photon absorption mechanisms were evidenced on both materials, thanks to a wavelength-tunable femtosecond laser chain. These results are applied to single event effect investigations on a commercial gallium nitride high electron mobility transistor. We could trigger single event transients by focusing the beam throughout the silicon substrate and collect charge that was photogenerated in the gallium nitride layer by a three-photon absorption process.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1533-1540
14 Years of In-Flight Experimental Data on CARMEN-MEX
This paper presents in-flight Single Event Effects (SEE), Total Ionizing Dose (TID) and Total Non-Ionizing Dose (TNID) data collected since 2008 by CNES with CARMEN-MEX experiment on board of various satellites placed in Low-Earth Orbit or Geostationary orbits.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 70 (8) , 1533-1540
14 Years of In-Flight Experimental Data on CARMEN-MEX
This paper presents in-flight Single Event Effects (SEE), Total Ionizing Dose (TID) and Total Non-Ionizing Dose (TNID) data collected since 2008 by CNES with CARMEN-MEX experiment on board of various satellites placed in Low-Earth Orbit or Geostationary orbits.