Feng Xue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Feng Xue has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Dezhi Chen
State Key Laboratory of Advanced Electromagnetic Technology, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Chen Zuo
Huazhong University of Science and Technology
2 shared publications - Dong Li
Huazhong University of Science and Technology
2 shared publications Chaojie Jiang
Hefei Genius Advanced Material Co.,Ltd., Hefei, 230601, China
1 shared publicationChen Zuo
1 shared publicationDong Li
1 shared publication
Latest Publications
- Top Cited Papers
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 6202-6216
Distribution-Level Local Imbalance Market for Multi-Timescale Settlement and Network-Constrained Balancing
Existing local energy markets (LEMs) and local flexibility markets (LFMs) in distribution systems are primarily designed to facilitate energy trading and alleviate congestion. However, they lack explicit mechanisms for modeling nodal power deviations, pricing marginal imbalance costs, and allocating fast frequency response. This paper proposes a local imbalance market (LIM) that introduces a node-level imbalance formulation and distribution locational imbalance prices (DLIPs), internalizing network constraints and the balancing costs induced by power imbalances. The LIM incorporates a multi-timescale clearing structure where the distribution system operator (DSO) computes minute-level balancing decisions and DLIPs. A frequency response sensitivity matrix (FRSM) allocates second-scale fast-response costs to the nodes that caused the deviations. A native ADMM-based LIM clearing algorithm is designed to achieve scalable, privacy-preserving coordination among prosumers, aggregators, and the DSO without revealing private information. The second-scale allocation algorithm ensures cost causality and budget consistency through real-time measurement and expost reconciliation. Case studies on three modified distribution networks demonstrate that the proposed LIM enhances balancing efficiency, preserves participant privacy, and achieves accurate cost attribution under renewable uncertainty. The LIM provides a practical and economically consistent pathway for integrating renewable-rich resources into distribution-level market operations.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (6) , 6202-6216
Top Cited PapersDistribution-Level Local Imbalance Market for Multi-Timescale Settlement and Network-Constrained Balancing
Existing local energy markets (LEMs) and local flexibility markets (LFMs) in distribution systems are primarily designed to facilitate energy trading and alleviate congestion. However, they lack explicit mechanisms for modeling nodal power deviations, pricing marginal imbalance costs, and allocating fast frequency response. This paper proposes a local imbalance market (LIM) that introduces a node-level imbalance formulation and distribution locational imbalance prices (DLIPs), internalizing network constraints and the balancing costs induced by power imbalances. The LIM incorporates a multi-timescale clearing structure where the distribution system operator (DSO) computes minute-level balancing decisions and DLIPs. A frequency response sensitivity matrix (FRSM) allocates second-scale fast-response costs to the nodes that caused the deviations. A native ADMM-based LIM clearing algorithm is designed to achieve scalable, privacy-preserving coordination among prosumers, aggregators, and the DSO without revealing private information. The second-scale allocation algorithm ensures cost causality and budget consistency through real-time measurement and expost reconciliation. Case studies on three modified distribution networks demonstrate that the proposed LIM enhances balancing efficiency, preserves participant privacy, and achieves accurate cost attribution under renewable uncertainty. The LIM provides a practical and economically consistent pathway for integrating renewable-rich resources into distribution-level market operations.
- Open Access
- 6 November 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (5) , 103279
Analysis and optimization of cesium dynamics for the HUST negative ion source
- 6 November 2024
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 57 (5) , 103279
Open AccessAnalysis and optimization of cesium dynamics for the HUST negative ion source
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Research of Cesium Adsorption on Mo and Ni Based on Temperature-Controlled Quartz Microbalance
The appropriate cesium adsorption on the converter (plasma grid) in the negative ion source is expected to lower surface work function, thus enhancing negative ion production and decreasing the ratio of co-extracted electrons. The cesium coverage process is important in understanding cesium dynamics and provides input parameters for simulation of cesium-wall interaction. The cesium coverage model based on Langmuir theory is established with analytical solution. Based on temperature-controlled quartz microbalance (QMB), experiments are carried out on different crystals under various cesium flux and surface temperatures, to simulate the actual cesium injection environment in negative ion sources. The experimental data are analyzed and compared with the fitting curves of cesium coverage theoretical model. The results show the influence of surface temperatures and materials on cesium adsorption, along with the sticking coefficients calculated.
- 17 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Research of Cesium Adsorption on Mo and Ni Based on Temperature-Controlled Quartz Microbalance
The appropriate cesium adsorption on the converter (plasma grid) in the negative ion source is expected to lower surface work function, thus enhancing negative ion production and decreasing the ratio of co-extracted electrons. The cesium coverage process is important in understanding cesium dynamics and provides input parameters for simulation of cesium-wall interaction. The cesium coverage model based on Langmuir theory is established with analytical solution. Based on temperature-controlled quartz microbalance (QMB), experiments are carried out on different crystals under various cesium flux and surface temperatures, to simulate the actual cesium injection environment in negative ion sources. The experimental data are analyzed and compared with the fitting curves of cesium coverage theoretical model. The results show the influence of surface temperatures and materials on cesium adsorption, along with the sticking coefficients calculated.
- 4 January 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 102, 105174
Coupling coordination evaluation of “Three Waters” system and impulse response analysis in the Yellow River Basin
- 4 January 2024
- Published by Elsevier in Sustainable Cities and Society
- Vol. 102, 105174
Coupling coordination evaluation of “Three Waters” system and impulse response analysis in the Yellow River Basin
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Investigation of Surface Ionization Detector for Cesium Oven Evaporation Rate
To assure stable cesium injection for negative ion source, the surface ionization detector (SID) is applied for diagnosis. Consisted of emitter and collector, the SID is operating based on bias voltage setting to drive the ionized cesium ions from emitter to the collector for detection. An analysis model of SID for cesium oven evaporation rate is established, investigating the process of cesium transportation in vacuum, thermionic ionization and cesium ion collection. Cesium transportation from nozzle to SID in vacuum is studied on the basis of free molecule flow model, and the cesium density distribution is obtained after having estimated cesium flux density ratio intercepted by SID from nozzle. The collection period is analyzed by particle tracking model, providing the relationship of SID current and ionized cesium current under adaptive bias voltage along with characteristics between SID current and bias voltage reproduced corresponding to experimental results. The model is adjustable and flexible to deal with different 3D structures, geometry and electric field setting. SID analysis for cesium oven of HUST negative ion source is carried out to monitor oven operation and to provide evaporation rate features under various oven temperatures along with error analysis.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Investigation of Surface Ionization Detector for Cesium Oven Evaporation Rate
To assure stable cesium injection for negative ion source, the surface ionization detector (SID) is applied for diagnosis. Consisted of emitter and collector, the SID is operating based on bias voltage setting to drive the ionized cesium ions from emitter to the collector for detection. An analysis model of SID for cesium oven evaporation rate is established, investigating the process of cesium transportation in vacuum, thermionic ionization and cesium ion collection. Cesium transportation from nozzle to SID in vacuum is studied on the basis of free molecule flow model, and the cesium density distribution is obtained after having estimated cesium flux density ratio intercepted by SID from nozzle. The collection period is analyzed by particle tracking model, providing the relationship of SID current and ionized cesium current under adaptive bias voltage along with characteristics between SID current and bias voltage reproduced corresponding to experimental results. The model is adjustable and flexible to deal with different 3D structures, geometry and electric field setting. SID analysis for cesium oven of HUST negative ion source is carried out to monitor oven operation and to provide evaporation rate features under various oven temperatures along with error analysis.
- 17 August 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 321, 115997
Photoaging and release profile of acrylonitrile butadiene styrene microplastics under simulated solar radiation in water
- 17 August 2022
- Published by Elsevier in Journal of Environmental Management
- Vol. 321, 115997
Photoaging and release profile of acrylonitrile butadiene styrene microplastics under simulated solar radiation in water
- 22 March 2022
- Published by Springer Nature
- p. 303-312
Analysis and Test of RSA Algorithm in Smart Electricity Meter Identity Authentication
- 22 March 2022
- Published by Springer Nature
- p. 303-312
Analysis and Test of RSA Algorithm in Smart Electricity Meter Identity Authentication
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-5
Microscopic Simulation and Characteristics Analysis of Point Discharge Based on PIC-MCC Method
Point discharge is a typical kind of Partial Discharge (PD) behavior. The microscopic process of particle movement is simulated in this paper by combing particle in cell (PIC) method with Monte Carlo collision (MCC) method, which possesses great significance for researching partial discharge. Simulation results show detailed motion process and the Townsend discharge phenomenon. As a result of simulation process, macro characteristics such as PD currents are analyzed to study discharge property. PD current pulse waveform possesses the trend of steep rising edge follows Gaussian distribution while gentle falling edge obeys Power function. The effect of voltage difference, air-gap size and polarity on PD characteristics are discussed in this paper.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 3, 1-5
Microscopic Simulation and Characteristics Analysis of Point Discharge Based on PIC-MCC Method
Point discharge is a typical kind of Partial Discharge (PD) behavior. The microscopic process of particle movement is simulated in this paper by combing particle in cell (PIC) method with Monte Carlo collision (MCC) method, which possesses great significance for researching partial discharge. Simulation results show detailed motion process and the Townsend discharge phenomenon. As a result of simulation process, macro characteristics such as PD currents are analyzed to study discharge property. PD current pulse waveform possesses the trend of steep rising edge follows Gaussian distribution while gentle falling edge obeys Power function. The effect of voltage difference, air-gap size and polarity on PD characteristics are discussed in this paper.