Jinshi Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jinshi Zhao has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Burak Temelkuran
Department of Metabolism, Digestion and Reproduction Imperial College London London UK
6 shared publications - Ali Anil Demircali
Divisions in System Medicine Department of Metabolism Digestion and Reproduction Faculty of Medicine Imperial College London London UK
4 shared publications - Eric Morgan Yeatman
Department of Electrical and Electronic Engineering, Imperial College London, London, UK
3 shared publications - Mohamed E. M. K. Abdelaziz
Department of Metabolism Digestion and Reproduction Division of Systems Medicine Imperial College London London UK
3 shared publications - Ayhan Aktas
Department of Mechanical Engineering Bursa Uludağ University Bursa Türkiye
2 shared publications - Bing Li
Institute for Materials Discovery Department of Chemistry University College London London WC1E 7JE UK
2 shared publications
Latest Publications
- Open Access
- 19 August 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (11) , e70513
Thermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation
To navigate medical instruments safely and accurately inside a patient’s vascular tree, combining X‐ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks and necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non‐fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without X‐ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micromachining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter’s mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.
- 19 August 2026
- Published by Wiley in Advanced Intelligent Systems
- Vol. 8 (11) , e70513
Open AccessThermally Drawn Bioelectric Catheters: Enabling Proprioceptive Endovascular Navigation
To navigate medical instruments safely and accurately inside a patient’s vascular tree, combining X‐ray fluoroscopy with intermittent contrast injections is the gold standard. However, prolonged exposure to ionizing radiation poses health risks and necessitates the use of cumbersome lead vests for the clinicians, and contrast injections can lead to acute kidney injury in patients. Bioelectric Navigation, a non‐fluoroscopic tracking modality, aims to provide an alternative. It uses weak electric currents to detect local anatomical features in the vasculature and localize instruments without X‐ray imaging. In this work, we advance Bioelectric Navigation on two frontiers. Firstly, we introduce a new class of bespokely designed electrode catheters. They are fabricated using 3D printing, thermal drawing, and laser micromachining. Specifically, we manufacture a 6 Fr catheter incorporating 16 electrodes, a guidewire channel and an additional sensor compartment. We thoroughly assess the catheter’s mechanical and electrical properties. Secondly, we introduce an algorithm to localize the catheter along the centerline of a vascular phantom, for the first time fusing electric detection of vascular geometry with electric distance estimation. We report both tracking accuracy and usability evaluated by an expert endovascular surgeon, demonstrating the strong potential of this technology for integration into the existing clinical workflow.
- Open Access
- 29 July 2026
- Published by Wiley in Advanced Robotics Research
- p. e70153
Autonomous Navigation of Pollen‐Inspired Magnetic Microrobots for Biomedical Applications
Recent advances in microrobotics have expanded opportunities for biomedical delivery, but reliable navigation in complex microvascular environments remains challenging, particularly when continuous imaging is limited. Here we develop a sunflower pollen‐inspired magnetic microrobot for targeted delivery and tissue engineering applications. Fabricated by two‐photon polymerization and coated with nickel and titanium for magnetic actuation and biocompatibility, the 40 µm microrobot features an open, hydrodynamic geometry that facilitates cell adhesion through its surface topology. Finite‐element analysis supported this design rationale, showing 4.45‐fold lower translational drag and 4.1‐fold lower rotational hydrodynamic resistance than a solid spherical microrobot of the same outer diameter. We demonstrated stable rolling under physiologically relevant flow conditions, including upstream motion against opposing flow, and evaluated autonomous navigation in static and dynamic environments using a vision‐based closed‐loop controller combined with reinforcement learning. The system enabled trajectory tracking, shortest‐path selection, and multiturn maze navigation with microrobot‐scale error. By combining efficient rolling locomotion with navigation based on intermittent visual updates, this platform supports microrobot guidancein future minimally invasive interventions where continuous monitoring is restricted.
- 29 July 2026
- Published by Wiley in Advanced Robotics Research
- p. e70153
Open AccessAutonomous Navigation of Pollen‐Inspired Magnetic Microrobots for Biomedical Applications
Recent advances in microrobotics have expanded opportunities for biomedical delivery, but reliable navigation in complex microvascular environments remains challenging, particularly when continuous imaging is limited. Here we develop a sunflower pollen‐inspired magnetic microrobot for targeted delivery and tissue engineering applications. Fabricated by two‐photon polymerization and coated with nickel and titanium for magnetic actuation and biocompatibility, the 40 µm microrobot features an open, hydrodynamic geometry that facilitates cell adhesion through its surface topology. Finite‐element analysis supported this design rationale, showing 4.45‐fold lower translational drag and 4.1‐fold lower rotational hydrodynamic resistance than a solid spherical microrobot of the same outer diameter. We demonstrated stable rolling under physiologically relevant flow conditions, including upstream motion against opposing flow, and evaluated autonomous navigation in static and dynamic environments using a vision‐based closed‐loop controller combined with reinforcement learning. The system enabled trajectory tracking, shortest‐path selection, and multiturn maze navigation with microrobot‐scale error. By combining efficient rolling locomotion with navigation based on intermittent visual updates, this platform supports microrobot guidancein future minimally invasive interventions where continuous monitoring is restricted.
- Open Access
- 6 July 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (18)
Fabrication of Fibers With Complex Features Using Thermal Drawing of 3D‐Printed Preforms
High‐aspect‐ratio polymer materials are widely utilized in applications ranging from everyday materials to specialized equipment in industrial and medical fields. Traditional fabrication methods, such as extrusion and molding, face challenges in integrating diverse materials and achieving complex geometries. Thermal drawing transforms macroscale preforms into long, thin fibers while preserving cross‐sectional geometry, but preform fabrication remains a key limitation for producing complex and functional fiber architectures. Here, commercially available 3D printing is used as a fast, low‐cost route for fabricating polymer preforms for thermal drawing. By optimizing printing parameters, fibers with diameters down to 100 µm are produced while preserving complex cross‐sectional features at the micron scale. This capability enables miniaturization of interlocking fiber geometries designed for steerable catheter concepts. Beyond amorphous thermoplastics, semi‐crystalline polypropylene preforms are drawn to produce fibers that exhibit a fivefold greater tendon‐driven bending response than comparable polycarbonate fibers. Functional material integration is further demonstrated using magnetically loaded filament to produce magnetically responsive fibers for robotic applications. Longitudinal periodicity engineered into the preform produces tapered fibers with programmable stiffness gradients in a single fabrication run. This approach supports rapid translation from preform design to thermally drawn polymer fibers with complex geometries, broader material selection, and application‐specific functionality.
- 6 July 2026
- Published by Wiley in Advanced Materials Technologies
- Vol. 11 (18)
Open AccessFabrication of Fibers With Complex Features Using Thermal Drawing of 3D‐Printed Preforms
High‐aspect‐ratio polymer materials are widely utilized in applications ranging from everyday materials to specialized equipment in industrial and medical fields. Traditional fabrication methods, such as extrusion and molding, face challenges in integrating diverse materials and achieving complex geometries. Thermal drawing transforms macroscale preforms into long, thin fibers while preserving cross‐sectional geometry, but preform fabrication remains a key limitation for producing complex and functional fiber architectures. Here, commercially available 3D printing is used as a fast, low‐cost route for fabricating polymer preforms for thermal drawing. By optimizing printing parameters, fibers with diameters down to 100 µm are produced while preserving complex cross‐sectional features at the micron scale. This capability enables miniaturization of interlocking fiber geometries designed for steerable catheter concepts. Beyond amorphous thermoplastics, semi‐crystalline polypropylene preforms are drawn to produce fibers that exhibit a fivefold greater tendon‐driven bending response than comparable polycarbonate fibers. Functional material integration is further demonstrated using magnetically loaded filament to produce magnetically responsive fibers for robotic applications. Longitudinal periodicity engineered into the preform produces tapered fibers with programmable stiffness gradients in a single fabrication run. This approach supports rapid translation from preform design to thermally drawn polymer fibers with complex geometries, broader material selection, and application‐specific functionality.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (12) , 12389-12396
Thermally Drawn Steerable Soft Robotic Fiber for Multi-Purpose Minimally Invasive Surgery
Soft robotic instruments offer unique advantages for minimally invasive surgery (MIS), including safe tissue interaction and adaptability within confined anatomical spaces. However, achieving both miniaturization and functionality within a single device remains a significant engineering challenge. This work presents a monolithically fabricated, tendon-driven fiber robot produced via thermal drawing, integrating rigid polycarbonate (PC) and compliant Styrene-Ethylene-Butylene-Styren (SEBS) elastomer into a continuous, multi-lumen structure. The resulting platform enables remote steering of the fiber tip while supporting channels for additional diagnostic or therapeutic functions. Three purpose-specific fiber variants were developed and evaluated in anatomical phantoms: transvaginal tumor ablation requiring high-precision motion control, gastrointestinal optical diagnosis with spectroscopic sensing, and endovascular navigation with targeted liquid delivery. These demonstrations validate the robot’s precision, adaptability, and clinical relevance across multiple MIS scenarios. The proposed thermally drawn fiber offers a scalable approach for rapid prototyping and development of compact, multi-purpose medical devices.
- 9 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (12) , 12389-12396
Thermally Drawn Steerable Soft Robotic Fiber for Multi-Purpose Minimally Invasive Surgery
Soft robotic instruments offer unique advantages for minimally invasive surgery (MIS), including safe tissue interaction and adaptability within confined anatomical spaces. However, achieving both miniaturization and functionality within a single device remains a significant engineering challenge. This work presents a monolithically fabricated, tendon-driven fiber robot produced via thermal drawing, integrating rigid polycarbonate (PC) and compliant Styrene-Ethylene-Butylene-Styren (SEBS) elastomer into a continuous, multi-lumen structure. The resulting platform enables remote steering of the fiber tip while supporting channels for additional diagnostic or therapeutic functions. Three purpose-specific fiber variants were developed and evaluated in anatomical phantoms: transvaginal tumor ablation requiring high-precision motion control, gastrointestinal optical diagnosis with spectroscopic sensing, and endovascular navigation with targeted liquid delivery. These demonstrations validate the robot’s precision, adaptability, and clinical relevance across multiple MIS scenarios. The proposed thermally drawn fiber offers a scalable approach for rapid prototyping and development of compact, multi-purpose medical devices.
- Top Cited PapersOpen Access
- 19 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (3) , eadj1984
Fiberbots: Robotic fibers for high-precision minimally invasive surgery
Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.
- 19 January 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (3) , eadj1984
Top Cited PapersOpen AccessFiberbots: Robotic fibers for high-precision minimally invasive surgery
Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.
- Open Access
Fiberbots: Robotic fibers for high-precision minimally invasive surgery
Technologies that rely on the fundamental principle of thermal expansion have demonstrated high-precision, a growing demand in fields driven by miniaturization. However, scalable production of high aspect ratio devices that harness this capability while facilitating flexibility in design and functionality remains a challenge. We employed the high-throughput fiber thermal drawing technique to readily fabricate multimaterial fiberbots that can precisely and omnidirectionally move by asymmetric thermal expansion. These millimeter-scale fibers (< 2 mm) show excellent repeatability and linearity, negligible hysteresis, and can achieve micron-level resolution over four orders of magnitude motion range. By integrating these robotic fibers with medical devices that can perform cellular-level tissue imaging, diagnosis, and manipulation, we showcase their versatility through benchtop and preclinical animal studies and their overall potential impact on medicine, biomedical engineering, robotics, and beyond. One Sentence Summary Scalable manufacturing and integration of robotic fibers that deliver high-precision motion when heated.
Open AccessFiberbots: Robotic fibers for high-precision minimally invasive surgery
Technologies that rely on the fundamental principle of thermal expansion have demonstrated high-precision, a growing demand in fields driven by miniaturization. However, scalable production of high aspect ratio devices that harness this capability while facilitating flexibility in design and functionality remains a challenge. We employed the high-throughput fiber thermal drawing technique to readily fabricate multimaterial fiberbots that can precisely and omnidirectionally move by asymmetric thermal expansion. These millimeter-scale fibers (< 2 mm) show excellent repeatability and linearity, negligible hysteresis, and can achieve micron-level resolution over four orders of magnitude motion range. By integrating these robotic fibers with medical devices that can perform cellular-level tissue imaging, diagnosis, and manipulation, we showcase their versatility through benchtop and preclinical animal studies and their overall potential impact on medicine, biomedical engineering, robotics, and beyond. One Sentence Summary Scalable manufacturing and integration of robotic fibers that deliver high-precision motion when heated.