Ludovica Filippini
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ludovica Filippini has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Antonella Lisi
Institute of Translational Pharmacology, National Research Council, Via Fosso del Cavaliere 100, 00133 Rome, Italy
2 shared publications - Federica Liguori
Cellex S.r.L, Piazzale delle Belle Arti 2, 00196 Roma, Italy
2 shared publications - Giuseppe Falvo D'URso Labate
Cellex srl, Piazzale delle Belle Arti 2, 00196 Roma, Italy
2 shared publications - Mario Ledda
Institute of Translational Pharmacology, National Research Council, Rome, Italy
2 shared publications - Alessia Mengoni
Institute of Translational Pharmacology (CNR-IFT), National Research Council, Via Fosso del Cavaliere 100, 00133 Roma, Italy
1 shared publication Giulia Gramigna
Consiglio Nazionale delle Ricerche, Istituto di Farmacologia Traslazionale, Roma, via del Fosso del Cavaliere100; Italy
1 shared publication
Latest Publications
- Open Access
- 18 December 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (12) , 848
A Fluid Dynamics-Model System for Advancing Tissue Engineering and Cancer Research Studies: Biological Assessment of the Innovative BioAxFlow Dynamic Culture Bioreactor
In this study, an innovative bioreactor, named BioAxFlow, particularly suitable for tissue engineering applications, is tested. Unlike traditional bioreactors, it does not rely on mechanical components to agitate the culture medium, but on the unique fluid-dynamics behaviour induced by the geometry of the culture chamber, which ensures continuous movement of the medium, promoting the constant exposure of the cells to nutrients and growth factors. Using the human osteosarcoma cell line SAOS-2, the bioreactor’s ability to enhance cell adhesion and proliferation on polylactic acid (PLA) scaffolds, mimicking bone matrix architecture, is investigated. Cells cultured in the bioreactor showed significant improvement in cell growth and adhesion, compared to static cultures, and a more homogeneous cell distribution upon the scaffold surfaces, which is crucial for the development of functional tissue constructs. The bioreactor also preserves the osteogenic potential of SAOS-2 cells as assessed by the expression of key osteogenic markers. Additionally, it retains the tumorigenic characteristics of SAOS-2 cells, including the expression of pro-angiogenic factors and apoptosis-related genes. These results indicate that the BioAxFlow bioreactor could be an effective platform for tissue engineering and cancer research, offering a promising tool for both regenerative medicine applications and drug testing.
- 18 December 2025
- Published by MDPI AG in Biomimetics
- Vol. 10 (12) , 848
Open AccessA Fluid Dynamics-Model System for Advancing Tissue Engineering and Cancer Research Studies: Biological Assessment of the Innovative BioAxFlow Dynamic Culture Bioreactor
In this study, an innovative bioreactor, named BioAxFlow, particularly suitable for tissue engineering applications, is tested. Unlike traditional bioreactors, it does not rely on mechanical components to agitate the culture medium, but on the unique fluid-dynamics behaviour induced by the geometry of the culture chamber, which ensures continuous movement of the medium, promoting the constant exposure of the cells to nutrients and growth factors. Using the human osteosarcoma cell line SAOS-2, the bioreactor’s ability to enhance cell adhesion and proliferation on polylactic acid (PLA) scaffolds, mimicking bone matrix architecture, is investigated. Cells cultured in the bioreactor showed significant improvement in cell growth and adhesion, compared to static cultures, and a more homogeneous cell distribution upon the scaffold surfaces, which is crucial for the development of functional tissue constructs. The bioreactor also preserves the osteogenic potential of SAOS-2 cells as assessed by the expression of key osteogenic markers. Additionally, it retains the tumorigenic characteristics of SAOS-2 cells, including the expression of pro-angiogenic factors and apoptosis-related genes. These results indicate that the BioAxFlow bioreactor could be an effective platform for tissue engineering and cancer research, offering a promising tool for both regenerative medicine applications and drug testing.
- Open Access
A fluid dynamics-model system for advancing Tissue Engineering and Cancer Research studies: Dynamic Culture with the innovative BioAxFlow Bioreactor
In this study, we test an innovative bioreactor, particularly suitable for tissue engineering applications, named BioAxFlow. Unlike traditional bioreactors, it does not rely on mechanical components to agitate the culture medium, but on the fluid-dynamics generated thanks to the unique geometry of the culture chamber. The flow generated within ensures continuous medium movement, promoting consistent cell exposure to nutrients and growth factors. Using the human osteosarcoma cell line SAOS-2, the bioreactor’s ability to enhance cell adhesion and proliferation on polylactic acid scaffolds, mimicking bone tissue matrix architecture, is tested. The findings show that the bioreactor significantly improved cell adhesion and growth compared to static cultures, promoting a homogeneous cell distribution across the scaffold surfaces, which is crucial for developing functional tissue constructs. The bioreactor preserves the osteogenic potential of SAOS-2 cells as assessed by the expression of key osteogenic markers. Additionally, it retains the tumorigenic characteristics of SAOS-2 cells, including the expression of pro-angiogenic factors and apoptosis-related genes. These results indicate that the BioAxFlow bioreactor is an effective platform for tissue engineering and cancer research, offering a promising tool for both regenerative medicine applications and drug testing.
Open AccessA fluid dynamics-model system for advancing Tissue Engineering and Cancer Research studies: Dynamic Culture with the innovative BioAxFlow Bioreactor
In this study, we test an innovative bioreactor, particularly suitable for tissue engineering applications, named BioAxFlow. Unlike traditional bioreactors, it does not rely on mechanical components to agitate the culture medium, but on the fluid-dynamics generated thanks to the unique geometry of the culture chamber. The flow generated within ensures continuous medium movement, promoting consistent cell exposure to nutrients and growth factors. Using the human osteosarcoma cell line SAOS-2, the bioreactor’s ability to enhance cell adhesion and proliferation on polylactic acid scaffolds, mimicking bone tissue matrix architecture, is tested. The findings show that the bioreactor significantly improved cell adhesion and growth compared to static cultures, promoting a homogeneous cell distribution across the scaffold surfaces, which is crucial for developing functional tissue constructs. The bioreactor preserves the osteogenic potential of SAOS-2 cells as assessed by the expression of key osteogenic markers. Additionally, it retains the tumorigenic characteristics of SAOS-2 cells, including the expression of pro-angiogenic factors and apoptosis-related genes. These results indicate that the BioAxFlow bioreactor is an effective platform for tissue engineering and cancer research, offering a promising tool for both regenerative medicine applications and drug testing.
- Open Access
- 14 February 2023
- Published by Wiley in British Journal of Pharmacology
- Vol. 180 (10) , 1289-1303
Cav1.3‐selective inhibitors of voltage‐gated L‐type Ca2+ channels: Fact or (still) fiction?
Voltage‐gated L‐type Ca2+‐channels (LTCCs) are the target of Ca2+‐channel blockers (CCBs), which are in clinical use for the evidence‐based treatment of hypertension and angina. Their cardiovascular effects are largely mediated by the Cav1.2‐subtype. However, based on our current understanding of their physiological and pathophysiological roles, Cav1.3 LTCCs also appear as attractive drug targets for the therapy of various diseases, including treatment‐resistant hypertension, spasticity after spinal cord injury and neuroprotection in Parkinson's disease. Since CCBs inhibit both Cav1.2 and Cav1.3, Cav1.3‐selective inhibitors would be valuable tools to validate the therapeutic potential of Cav1.3 channel inhibition in preclinical models. Despite a number of publications reporting the discovery of Cav1.3‐selective blockers, their selectivity remains controversial. We conclude that at present no pharmacological tools exist that are suitable to confirm or refute a role of Cav1.3 channels in cellular responses. We also suggest essential criteria for a small molecule to be considered Cav1.3‐selective.
- 14 February 2023
- Published by Wiley in British Journal of Pharmacology
- Vol. 180 (10) , 1289-1303
Open AccessCav1.3‐selective inhibitors of voltage‐gated L‐type Ca2+ channels: Fact or (still) fiction?
Voltage‐gated L‐type Ca2+‐channels (LTCCs) are the target of Ca2+‐channel blockers (CCBs), which are in clinical use for the evidence‐based treatment of hypertension and angina. Their cardiovascular effects are largely mediated by the Cav1.2‐subtype. However, based on our current understanding of their physiological and pathophysiological roles, Cav1.3 LTCCs also appear as attractive drug targets for the therapy of various diseases, including treatment‐resistant hypertension, spasticity after spinal cord injury and neuroprotection in Parkinson's disease. Since CCBs inhibit both Cav1.2 and Cav1.3, Cav1.3‐selective inhibitors would be valuable tools to validate the therapeutic potential of Cav1.3 channel inhibition in preclinical models. Despite a number of publications reporting the discovery of Cav1.3‐selective blockers, their selectivity remains controversial. We conclude that at present no pharmacological tools exist that are suitable to confirm or refute a role of Cav1.3 channels in cellular responses. We also suggest essential criteria for a small molecule to be considered Cav1.3‐selective.