Leonardo Cano-Saldaña
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Leonardo Cano-Saldaña has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Cristhian Camilo Amariles-López
Professor, Dept. of Civil Engineering, Universidad Libre de Colombia, Pereira 660001, Colombia. ORCID:
1 shared publication Daniel Ramírez-Sepúlveda
Universidad del Quindío
1 shared publication- Elisa C. González
University of Quindío
1 shared publication - Gladys Elena Salcedo-Echeverry
University of Quindío
1 shared publication
Latest Publications
- Open Access
- 17 October 2023
- Published by Universidad Distrital Francisco Jose de Caldas in Ingeniería
- Vol. 28 (3) , e20447
Comparative Analysis between Singular Spectral Analysis and Empirical Mode Decomposition for Structural Damage Detection
Context: In recent years, thanks to technological advances in instrumentation and digital signal processing, noninvasive methods to detect structural damage have become increasingly important. Vibration-based structural health monitoring (SHM) techniques allow detecting the presence and location of damage from permanent changes in the fundamental frequencies of signals. A successfully employed method for damage detection is empirical mode decomposition (EMD). Another method, less used in this field of study, is singular spectral analysis (SSA). This paper describes both methods and presents a simulation study aimed at comparing them and identifying which one is more effective in detecting structural damage. Method: The methods of a reference study known as benchmark SHM were applied to facilitate the comparison. To evaluate the effectiveness of both methods, Monte Carlo simulation was employed. To control the random noise and other factors inherent to the simulation, the procedure was repeated 1.000 times for each type of damage. Results: In the case of severe damage, both methods showed a good performance. However, when the damage was slight, the changes in the fundamental frequency were not apparent. However, a significant change in the amplitude level was observed. In this case, SSA obtained the best results. Conclusions: The EMD and SSA methods, together with high-pass filtering, detected severe damage when the acceleration records had low or no noise. When the acceleration records were contaminated with noise, the likelihood of EMD detecting the damage decreased dramatically. One of the advantages of SSA over EMD is that, for moderate or mild damage patterns, the former does not require filters or the use of the Hilbert-Huang transform to detect damage. In general, it was found that SSA was more effective in detecting damage.
- 17 October 2023
- Published by Universidad Distrital Francisco Jose de Caldas in Ingeniería
- Vol. 28 (3) , e20447
Open AccessComparative Analysis between Singular Spectral Analysis and Empirical Mode Decomposition for Structural Damage Detection
Context: In recent years, thanks to technological advances in instrumentation and digital signal processing, noninvasive methods to detect structural damage have become increasingly important. Vibration-based structural health monitoring (SHM) techniques allow detecting the presence and location of damage from permanent changes in the fundamental frequencies of signals. A successfully employed method for damage detection is empirical mode decomposition (EMD). Another method, less used in this field of study, is singular spectral analysis (SSA). This paper describes both methods and presents a simulation study aimed at comparing them and identifying which one is more effective in detecting structural damage. Method: The methods of a reference study known as benchmark SHM were applied to facilitate the comparison. To evaluate the effectiveness of both methods, Monte Carlo simulation was employed. To control the random noise and other factors inherent to the simulation, the procedure was repeated 1.000 times for each type of damage. Results: In the case of severe damage, both methods showed a good performance. However, when the damage was slight, the changes in the fundamental frequency were not apparent. However, a significant change in the amplitude level was observed. In this case, SSA obtained the best results. Conclusions: The EMD and SSA methods, together with high-pass filtering, detected severe damage when the acceleration records had low or no noise. When the acceleration records were contaminated with noise, the likelihood of EMD detecting the damage decreased dramatically. One of the advantages of SSA over EMD is that, for moderate or mild damage patterns, the former does not require filters or the use of the Hilbert-Huang transform to detect damage. In general, it was found that SSA was more effective in detecting damage.
- Open Access
- 26 December 2022
- Published by Universidad Militar Nueva Granada in Ciencia e Ingeniería Neogranadina
- Vol. 32 (2) , 115-129
Comparación entre el ACI-318-19 y la NSR-10 para diseño estructural de pórticos de concreto en zonas de amenaza sísmica alta
En este trabajo se realiza un análisis comparativo de la Norma Colombiana Sismorresistente NSR-10 y el reglamento ACI 318-19 (base del próximo título C de la norma NSR actualmente en desarrollo), en dicha comparación se detallaron las exigencias técnicas actuales presentes en ambos reglamentos para sistemas de pórticos de concreto reforzado en zonas de amenaza sísmica alta. Inicialmente se realizó un análisis comparativo entre el cuerpo del título C de la NSR-10 y el reglamento ACI 318-19 mostrando las diferencias en la disposición de cada uno de los capítulos presentes en cada normatividad, de este análisis se obtiene una matriz comparativa y los mapas de ruta correspondiente a cada capítulo, los cuales facilitaran la búsqueda y comprensión de las diferencias encontradas en la disposición de los capítulos. Posteriormente se realiza un segundo análisis comparativo confrontando uno a uno los requisitos para elementos pertenecientes a estructuras con capacidad especial de disipación de energía. De esta segunda comparación se detallan las diferencias más relevantes encontradas entre las especificaciones de ambas normativas, acompañada de una breve justificación de los cambios encontrados. Finalmente, se realiza el diseño estructural de dos edificaciones aporticadas de concreto reforzado, siguiendo los lineamientos de ambas normativas con el fin de realizar un comparativo final de las cuantías de refuerzo y volúmenes de concreto por medio del cual, se realizó un análisis del impacto económico que generará la aplicación de las nuevas especificaciones establecidas en el reglamento ACI 318-19, encontrándose una diferencia porcentual de aumento de costos del 2.2%.
- 26 December 2022
- Published by Universidad Militar Nueva Granada in Ciencia e Ingeniería Neogranadina
- Vol. 32 (2) , 115-129
Open AccessComparación entre el ACI-318-19 y la NSR-10 para diseño estructural de pórticos de concreto en zonas de amenaza sísmica alta
En este trabajo se realiza un análisis comparativo de la Norma Colombiana Sismorresistente NSR-10 y el reglamento ACI 318-19 (base del próximo título C de la norma NSR actualmente en desarrollo), en dicha comparación se detallaron las exigencias técnicas actuales presentes en ambos reglamentos para sistemas de pórticos de concreto reforzado en zonas de amenaza sísmica alta. Inicialmente se realizó un análisis comparativo entre el cuerpo del título C de la NSR-10 y el reglamento ACI 318-19 mostrando las diferencias en la disposición de cada uno de los capítulos presentes en cada normatividad, de este análisis se obtiene una matriz comparativa y los mapas de ruta correspondiente a cada capítulo, los cuales facilitaran la búsqueda y comprensión de las diferencias encontradas en la disposición de los capítulos. Posteriormente se realiza un segundo análisis comparativo confrontando uno a uno los requisitos para elementos pertenecientes a estructuras con capacidad especial de disipación de energía. De esta segunda comparación se detallan las diferencias más relevantes encontradas entre las especificaciones de ambas normativas, acompañada de una breve justificación de los cambios encontrados. Finalmente, se realiza el diseño estructural de dos edificaciones aporticadas de concreto reforzado, siguiendo los lineamientos de ambas normativas con el fin de realizar un comparativo final de las cuantías de refuerzo y volúmenes de concreto por medio del cual, se realizó un análisis del impacto económico que generará la aplicación de las nuevas especificaciones establecidas en el reglamento ACI 318-19, encontrándose una diferencia porcentual de aumento de costos del 2.2%.