Martina Butori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Martina Butori has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Göran Lindbergh
KTH Royal Institute of Technology
6 shared publications - Rakel Wreland Lindström
KTH Royal Institute of Technology
6 shared publications Björn Eriksson
KTH Royal Institute of Technology
5 shared publicationsCarina Lagergren
KTH Royal Institute of Technology
5 shared publications- Björn Eriksson
Department of Chemical Engineering Applied Electrochemistry KTH Royal Institute of Technology Stockholm Sweden
3 shared publications - Björn Wickman
Department of Physics and Astronomy, Chalmers University of Technology, 412 96 Göteborg, Sweden
3 shared publications
Latest Publications
- Open Access
Solid-State Sulfonation of Dense Poly(2,6-Dimethyl-1,4-Phenylene Oxide) Films: Membrane Properties and Electrochemical Assessment at MEA Level
Fluorine-free hydrocarbon proton-exchange membranes offer an alternative to perfluorosulfonic acid (PFSA) electrolytes, but good membrane-level properties do not always translate into membrane-electrode assembly (MEA) performance. Here, dense poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) films were sulfonated in the solid state, yielding a sulfur distribution that appeared homogeneous through the membrane thickness and ion-exchange capacities (IEC) of 1.17–2.20 meq g−1, corresponding to sulfonation degrees of 16–32 mol% and water uptake from 55 to 92%. The sulfonated PPO (sPPO) membrane with the highest IEC that remained self-standing was tested in a single-cell MEA and compared with a Nafion® 212-based MEA prepared and operated in the same way. The sPPO-based MEA showed lower hydrogen crossover and higher apparent short-circuit resistance than the Nafion® 212 reference. However, its high-frequency resistance (HFR) was also higher, corresponding to an apparent MEA-level conductivity of 11 mS cm−1 at 80 °C and 70% RH, compared with 40 mS cm−1 for Nafion® 212. This gap persists even though sPPO has a higher hydration number. Since the catalyst layers contain a PFSA ionomer, this HFR-based conductivity includes membrane, electrode, and interfacial contributions. The sPPO membrane reached a peak power density of 0.45 W cm−2 at 80 °C and 90% RH. In a short-term potentiostatic test, the sPPO-based MEA failed after approximately 6 h. Together with swelling, tensile, and Fenton data, these results identify dimensional control, oxidative stabilization, and better membrane–ionomer compatibility as the next steps and provide a quantitative MEA-level baseline for solid-state sulfonated PPO membranes.
Open AccessSolid-State Sulfonation of Dense Poly(2,6-Dimethyl-1,4-Phenylene Oxide) Films: Membrane Properties and Electrochemical Assessment at MEA Level
Fluorine-free hydrocarbon proton-exchange membranes offer an alternative to perfluorosulfonic acid (PFSA) electrolytes, but good membrane-level properties do not always translate into membrane-electrode assembly (MEA) performance. Here, dense poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) films were sulfonated in the solid state, yielding a sulfur distribution that appeared homogeneous through the membrane thickness and ion-exchange capacities (IEC) of 1.17–2.20 meq g−1, corresponding to sulfonation degrees of 16–32 mol% and water uptake from 55 to 92%. The sulfonated PPO (sPPO) membrane with the highest IEC that remained self-standing was tested in a single-cell MEA and compared with a Nafion® 212-based MEA prepared and operated in the same way. The sPPO-based MEA showed lower hydrogen crossover and higher apparent short-circuit resistance than the Nafion® 212 reference. However, its high-frequency resistance (HFR) was also higher, corresponding to an apparent MEA-level conductivity of 11 mS cm−1 at 80 °C and 70% RH, compared with 40 mS cm−1 for Nafion® 212. This gap persists even though sPPO has a higher hydration number. Since the catalyst layers contain a PFSA ionomer, this HFR-based conductivity includes membrane, electrode, and interfacial contributions. The sPPO membrane reached a peak power density of 0.45 W cm−2 at 80 °C and 90% RH. In a short-term potentiostatic test, the sPPO-based MEA failed after approximately 6 h. Together with swelling, tensile, and Fenton data, these results identify dimensional control, oxidative stabilization, and better membrane–ionomer compatibility as the next steps and provide a quantitative MEA-level baseline for solid-state sulfonated PPO membranes.
- Open Access
- 5 October 2026
- Published by Elsevier in SSRN Electronic Journal
Temperature and humidity dependent carbon corrosion in intermediate temperature proton exchange membrane fuel cells
Carbon corrosion of the catalyst support is a key degradation mechanism in proton exchange membrane fuel cells (PEMFCs), yet its behaviour at intermediate temperatures (IT, 80 – 120 °C) under normal operating voltages (<1 V) remains poorly characterised. This study uses operando mass spectrometry to quantify the carbon oxidation rate (COR) in single cells during square wave accelerated stress testing, examining the effects of temperature, relative humidity (RH), and potential limits. The COR is found to increase from 0.5 μg CO2/cycle at 80 °C to 3.2 μg CO2/cycle at 120 °C (70% RH), following Arrhenius like behaviour with an apparent activation energy of 43.5 kJ/mol. reducing RH at 120 °C lowers the COR, but holding water partial pressure constant still yields higher corrosion at elevated temperatures, demonstrating independent contributions from both temperature and humidity. Varying the high and low potential limits reveals that corrosion rates peak at high potential limits near 0.85 V and drop sharply when the low potential limit exceeds 0.6 V, pointing to a non-linear potential dependence. These results show that carbon support degradation is significantly more severe under IT-PEMFC conditions and underscore the importance of material selection, humidity control, and voltage window management in stack design.
- 5 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessTemperature and humidity dependent carbon corrosion in intermediate temperature proton exchange membrane fuel cells
Carbon corrosion of the catalyst support is a key degradation mechanism in proton exchange membrane fuel cells (PEMFCs), yet its behaviour at intermediate temperatures (IT, 80 – 120 °C) under normal operating voltages (<1 V) remains poorly characterised. This study uses operando mass spectrometry to quantify the carbon oxidation rate (COR) in single cells during square wave accelerated stress testing, examining the effects of temperature, relative humidity (RH), and potential limits. The COR is found to increase from 0.5 μg CO2/cycle at 80 °C to 3.2 μg CO2/cycle at 120 °C (70% RH), following Arrhenius like behaviour with an apparent activation energy of 43.5 kJ/mol. reducing RH at 120 °C lowers the COR, but holding water partial pressure constant still yields higher corrosion at elevated temperatures, demonstrating independent contributions from both temperature and humidity. Varying the high and low potential limits reveals that corrosion rates peak at high potential limits near 0.85 V and drop sharply when the low potential limit exceeds 0.6 V, pointing to a non-linear potential dependence. These results show that carbon support degradation is significantly more severe under IT-PEMFC conditions and underscore the importance of material selection, humidity control, and voltage window management in stack design.
- Open Access
- 3 February 2026
- Published by Wiley in ChemElectroChem
- Vol. 13 (3)
In Situ EQCM‐D Investigations of PEMFC Catalyst‐Ionomer Interactions
Proton exchange membrane fuel cell (PEMFC) electrodes comprise multiple functional components whose interplay critically influences both performance and long‐term stability. In this article, the interaction between ionomer and catalyst materials was investigated using electrochemical quartz crystal microbalance with dissipation monitoring, enabling detection of potential‐dependent changes in mass and viscoelastic properties. Measurements were conducted on platinum, carbon, and gold electrodes, with and without a Nafion overlayer, in 0.5 M H 2 SO 4 and 0.1 M HClO 4 . Additionally, a representative catalyst layer (CL) was fabricated by spray‐coating PEMFC catalyst ink onto quartz crystals and examined under identical electrochemical conditions. Enhanced hydration of Nafion on a platinum electrode was observed during potential cycling, attributed to electrochemical reactions at the platinum surface, rather than being a direct consequence of the applied potential as this behavior was not observed on crystals with Nafion‐covered carbon electrodes. Changes in viscoelastic properties and mass uptake was shown to be influenced by the choice of electrolyte solution, particularly the nature of the anions. Importantly, the response of the spray‐coated PEMFC‐CL aligns closely with the behavior observed for Nafion‐coated planar platinum, validating the simplified model approach and providing deeper insight into ionomer behavior under dynamic fuel cell conditions.
- 3 February 2026
- Published by Wiley in ChemElectroChem
- Vol. 13 (3)
Open AccessIn Situ EQCM‐D Investigations of PEMFC Catalyst‐Ionomer Interactions
Proton exchange membrane fuel cell (PEMFC) electrodes comprise multiple functional components whose interplay critically influences both performance and long‐term stability. In this article, the interaction between ionomer and catalyst materials was investigated using electrochemical quartz crystal microbalance with dissipation monitoring, enabling detection of potential‐dependent changes in mass and viscoelastic properties. Measurements were conducted on platinum, carbon, and gold electrodes, with and without a Nafion overlayer, in 0.5 M H 2 SO 4 and 0.1 M HClO 4 . Additionally, a representative catalyst layer (CL) was fabricated by spray‐coating PEMFC catalyst ink onto quartz crystals and examined under identical electrochemical conditions. Enhanced hydration of Nafion on a platinum electrode was observed during potential cycling, attributed to electrochemical reactions at the platinum surface, rather than being a direct consequence of the applied potential as this behavior was not observed on crystals with Nafion‐covered carbon electrodes. Changes in viscoelastic properties and mass uptake was shown to be influenced by the choice of electrolyte solution, particularly the nature of the anions. Importantly, the response of the spray‐coated PEMFC‐CL aligns closely with the behavior observed for Nafion‐coated planar platinum, validating the simplified model approach and providing deeper insight into ionomer behavior under dynamic fuel cell conditions.
- Open Access
- 16 September 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 658
The effect of temperature and load as a stressor for proton exchange membrane fuel cells durability at intermediate temperatures
- 16 September 2025
- Published by Elsevier in Journal of Power Sources
- Vol. 658
Open AccessThe effect of temperature and load as a stressor for proton exchange membrane fuel cells durability at intermediate temperatures
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (43) , 2929
How Do Hydrocarbon (HC)-Based Membrane Electrode Assemblies (MEAs) Compare with Perfluorosulfonic Acid (PFSA)-MEAs Above 80 °C?
The ongoing debate around the sustainability of per- and polyfluoroalkyl substances (PFASs) might restrict their use and the production in many sectors [1]. Particularly, in the field of proton exchange membrane fuel cells (PEMFCs), perfluorosulfonic acid (PFSA) ionomers, such as Nafion, represent the current state-of-the-art for membranes and ionomer in the catalyst layers (CLs). In fact, they provide an overall unmatched combination of properties such as ionic conductivity and stability [2,3]. In contrast, hydrocarbon (HC)-based polymers are an attractive alternative to PFSA-based materials, as they have been proven to be valid choices from a performance-standpoint and could potentially overcome the thermal stability limitations of PFSAs [4,5]. However, it has been reported that the conductivity of HC-based polymers is not surpassing that of PFSA-based polymers, especially in the CL, even upon optimization of the formulation [4,6]. Additionally, only a few studies report characterization of HC-MEAs above 80 °C, which is the targeted temperature range for some fuel cell applications [4,7]. In this work we used perfluorosulfonic acid (PFSA)- and sulfonated polyphenylene-based (HC)-polymers as ionomer in the CL and membrane in a fuel cell run above 80 °C. By spray-coating HC-based CLs onto either PFSA- or HC-membranes, we separated the contribution of the membrane from those of the electrodes and we analyzed the behaviour of each component individually. The electrochemical tests were performed between 80 and 120 °C, in a wide range of humidity and pressure levels. They included polarization curves and electrochemical impedance spectroscopy (EIS) in H2/air, similarly to our previous publications [8]. Additionally, we performed cyclic voltammetry and EIS to characterize the activity and conductivity of the cathode CL. Finally, by using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX), we analyzed cross-sections of sprayed samples before and after the test, to investigate possible changes in the structure. A SEM/EDX cross-section of a sample is shown in Figure 1. The MEA consisted of a PFSA-based membrane (with a mechanical reinforcement) and HC-based CLs. Results suggested that the membrane thickness is unchanged after spraying and that the catalyst layers had a quite compact structure and a thickness of about 9 and 6 μm, for respectively the CL on the left and the one on the right. The EDX elemental analysis confirmed that the fluoride signal was solely present in the membrane, where a PFSA-based polymer was employed, while no appreciable signal was detected in the electrodes given the fluoride-free polymer chosen as ionomer. By methodically analyzing the performance losses of different polymers in the CL and in the membrane, we contribute to directing the research where the greatest limitations are still present, above 80 °C. Figure 1 SEM/EDX cross-section of an in-house sprayed sample (left) and a zoom on the line scan with the corresponding EDX spectra for Pt, F and C (right). While the membrane is PFSA-based, the CL is HC-based. [1] European Chemical Agency, Per- and polyfluoroalkyl substances (PFAS), Regist. Restrict. Intentions until Outcome. (2023). https://echa.europa.eu/registry-of-restriction-intentions/-/dislist/details/0b0236e18663449b (accessed April 10, 2024). [2] Y. Prykhodko, K. Fatyeyeva, L. Hespel, S. Marais, Progress in hybrid composite Nafion®-based membranes for proton exchange fuel cell application, Chem. Eng. J. 409 (2021) 127329. https://doi.org/10.1016/j.cej.2020.127329. [3] D.A. Cullen, K.C. Neyerlin, R.K. Ahluwalia, R. Mukundan, K.L. More, R.L. Borup, A.Z. Weber, D.J. Myers, A. Kusoglu, New roads and challenges for fuel cells in heavy-duty transportation, Nat. Energy. 6 (2021) 462–474. https://doi.org/10.1038/s41560-021-00775-z. [4] H. Nguyen, F. Lombeck, C. Schwarz, P.A. Heizmann, M. Adamski, H.F. Lee, B. Britton, S. Holdcroft, S. Vierrath, M. Breitwieser, Hydrocarbon-based PemionTM proton exchange membrane fuel cells with state-of-the-art performance, Sustain. Energy Fuels. 5 (2021) 3687–3699. https://doi.org/10.1039/d1se00556a. [5] I. Innovations, Ionomr Innovations’ Pemion® hydrocarbon-based proton exchange membrane and polymer exceed industry durability targets, (n.d.). https://ionomr.com/wp-content/uploads/2023/01/Pemion-Durability-Data_News-Release-and-Technical-Backgrounder_For-Release-Jan19.pdf (accessed April 8, 2024). [6] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.-F. Lee, W.Y. Huang, S. Holdcroft, Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers, J. Electrochem. Soc. 162 (2015) F513–F518. https://doi.org/10.1149/2.0251506jes. [7] Hydrogen and Fuel Cell Technologies Office Energy.gov, Fuel Cell 2016 Multi-Year Research, Development and Demonstration Plan, 2016. https://www.energy.gov/sites/default/files/2017/05/f34/fcto_myrdd_fuel_cells.pdf. [8] M. Butori, B. Eriksson, N. Nikolić, C. Lagergren, G. Lindbergh, R. Wreland Lindström, R.W. Lindström, The Effect of Oxygen Partial Pressure and Humidification in Proton Exchange Membrane Fuel Cells at Intermediate Temperature (80 - 120 ◦C), J. Power Sources. 563 (2023). https://doi.org/10.1016/j.jpowsour.2023.232803. Figure 1
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (43) , 2929
How Do Hydrocarbon (HC)-Based Membrane Electrode Assemblies (MEAs) Compare with Perfluorosulfonic Acid (PFSA)-MEAs Above 80 °C?
The ongoing debate around the sustainability of per- and polyfluoroalkyl substances (PFASs) might restrict their use and the production in many sectors [1]. Particularly, in the field of proton exchange membrane fuel cells (PEMFCs), perfluorosulfonic acid (PFSA) ionomers, such as Nafion, represent the current state-of-the-art for membranes and ionomer in the catalyst layers (CLs). In fact, they provide an overall unmatched combination of properties such as ionic conductivity and stability [2,3]. In contrast, hydrocarbon (HC)-based polymers are an attractive alternative to PFSA-based materials, as they have been proven to be valid choices from a performance-standpoint and could potentially overcome the thermal stability limitations of PFSAs [4,5]. However, it has been reported that the conductivity of HC-based polymers is not surpassing that of PFSA-based polymers, especially in the CL, even upon optimization of the formulation [4,6]. Additionally, only a few studies report characterization of HC-MEAs above 80 °C, which is the targeted temperature range for some fuel cell applications [4,7]. In this work we used perfluorosulfonic acid (PFSA)- and sulfonated polyphenylene-based (HC)-polymers as ionomer in the CL and membrane in a fuel cell run above 80 °C. By spray-coating HC-based CLs onto either PFSA- or HC-membranes, we separated the contribution of the membrane from those of the electrodes and we analyzed the behaviour of each component individually. The electrochemical tests were performed between 80 and 120 °C, in a wide range of humidity and pressure levels. They included polarization curves and electrochemical impedance spectroscopy (EIS) in H2/air, similarly to our previous publications [8]. Additionally, we performed cyclic voltammetry and EIS to characterize the activity and conductivity of the cathode CL. Finally, by using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX), we analyzed cross-sections of sprayed samples before and after the test, to investigate possible changes in the structure. A SEM/EDX cross-section of a sample is shown in Figure 1. The MEA consisted of a PFSA-based membrane (with a mechanical reinforcement) and HC-based CLs. Results suggested that the membrane thickness is unchanged after spraying and that the catalyst layers had a quite compact structure and a thickness of about 9 and 6 μm, for respectively the CL on the left and the one on the right. The EDX elemental analysis confirmed that the fluoride signal was solely present in the membrane, where a PFSA-based polymer was employed, while no appreciable signal was detected in the electrodes given the fluoride-free polymer chosen as ionomer. By methodically analyzing the performance losses of different polymers in the CL and in the membrane, we contribute to directing the research where the greatest limitations are still present, above 80 °C. Figure 1 SEM/EDX cross-section of an in-house sprayed sample (left) and a zoom on the line scan with the corresponding EDX spectra for Pt, F and C (right). While the membrane is PFSA-based, the CL is HC-based. [1] European Chemical Agency, Per- and polyfluoroalkyl substances (PFAS), Regist. Restrict. Intentions until Outcome. (2023). https://echa.europa.eu/registry-of-restriction-intentions/-/dislist/details/0b0236e18663449b (accessed April 10, 2024). [2] Y. Prykhodko, K. Fatyeyeva, L. Hespel, S. Marais, Progress in hybrid composite Nafion®-based membranes for proton exchange fuel cell application, Chem. Eng. J. 409 (2021) 127329. https://doi.org/10.1016/j.cej.2020.127329. [3] D.A. Cullen, K.C. Neyerlin, R.K. Ahluwalia, R. Mukundan, K.L. More, R.L. Borup, A.Z. Weber, D.J. Myers, A. Kusoglu, New roads and challenges for fuel cells in heavy-duty transportation, Nat. Energy. 6 (2021) 462–474. https://doi.org/10.1038/s41560-021-00775-z. [4] H. Nguyen, F. Lombeck, C. Schwarz, P.A. Heizmann, M. Adamski, H.F. Lee, B. Britton, S. Holdcroft, S. Vierrath, M. Breitwieser, Hydrocarbon-based PemionTM proton exchange membrane fuel cells with state-of-the-art performance, Sustain. Energy Fuels. 5 (2021) 3687–3699. https://doi.org/10.1039/d1se00556a. [5] I. Innovations, Ionomr Innovations’ Pemion® hydrocarbon-based proton exchange membrane and polymer exceed industry durability targets, (n.d.). https://ionomr.com/wp-content/uploads/2023/01/Pemion-Durability-Data_News-Release-and-Technical-Backgrounder_For-Release-Jan19.pdf (accessed April 8, 2024). [6] A. Strong, B. Britton, D. Edwards, T.J. Peckham, H.-F. Lee, W.Y. Huang, S. Holdcroft, Alcohol-Soluble, Sulfonated Poly(arylene ether)s: Investigation of Hydrocarbon Ionomers for Proton Exchange Membrane Fuel Cell Catalyst Layers, J. Electrochem. Soc. 162 (2015) F513–F518. https://doi.org/10.1149/2.0251506jes. [7] Hydrogen and Fuel Cell Technologies Office Energy.gov, Fuel Cell 2016 Multi-Year Research, Development and Demonstration Plan, 2016. https://www.energy.gov/sites/default/files/2017/05/f34/fcto_myrdd_fuel_cells.pdf. [8] M. Butori, B. Eriksson, N. Nikolić, C. Lagergren, G. Lindbergh, R. Wreland Lindström, R.W. Lindström, The Effect of Oxygen Partial Pressure and Humidification in Proton Exchange Membrane Fuel Cells at Intermediate Temperature (80 - 120 ◦C), J. Power Sources. 563 (2023). https://doi.org/10.1016/j.jpowsour.2023.232803. Figure 1
- Open Access
- 29 June 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 95, 1158-1170
Ionic conductivity and hydrogen crossover for IT-PEMFCs: Influence of pressure, temperature, relative humidity and reinforcement
- 29 June 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 95, 1158-1170
Open AccessIonic conductivity and hydrogen crossover for IT-PEMFCs: Influence of pressure, temperature, relative humidity and reinforcement
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (38) , 1841
Investigating Proton Exchange Membrane Fuel Cell Durability at Intermediate Temperatures (80 – 120 °C)
For several applications the low operating temperature of 60-80 °C of proton exchange membrane fuel cells (PEMFCs) limit their potential use. Increasing this temperature above 100 °C would simplify the water management and increase the temperature of the produced heat which would allow for more effective cooling systems [1,2]. Further, increasing the operating temperature could potentially allow for other benefits, such as the employment of more affordable catalysts, as the reaction kinetics are enhanced at elevated temperatures. However, operating at higher temperatures can cause increased degradation on the utilized components [3]. In this work we investigated how commercial proton exchange membrane electrode assemblies (MEA) aged at various temperatures when operating either using a load cycle (based on the New European Drive Cycle) or constant load. The state of health of the MEA was continuously monitored through cyclic voltammetry, electrochemical impedance spectroscopy, linear sweep voltammetry, CO-stripping measurements and polarization curves. The obtained ageing results were evaluated using a physics-based model using COMSOL to better understand what aging mechanisms were pronounced at higher operating temperatures. Finally, the aged MEA were characterized with SEM and TEM analysis. The results show that all samples underwent an ageing process and that the ageing was accelerated at higher temperatures, as can be seen in the figure . Further, the ageing was more pronounced at a higher load. The measurements showed that the main ageing is occurring at the cathode catalyst layer and a drastic reduction in the electrochemical active surface area of the catalyst was observed. The membrane properties were also altered by the ageing, and a minor reduction in the membrane conductivity was observed. Surprisingly, no significant increase in the hydrogen crossover was observed, suggesting that the elevated temperature does not cause significant pinhole formation. The results shed light on the rate and mechanisms for ageing at various temperatures and can be used to determine the cost and benefits of operating at elevated temperatures. References [1] R.E. Rosli, A.B. Sulong, W.R.W. Daud, M.A. Zulkifley, T. Husaini, M.I. Rosli, E.H. Majlan, M.A. Haque, A review of high-temperature proton exchange membrane fuel cell (HT-PEMFC) system, Int. J. Hydrogen Energy. 42 (2017) 9293–9314. https://doi.org/10.1016/j.ijhydene.2016.06.211. [2] A. Chandan, M. Hattenberger, A. El-Kharouf, S. Du, A. Dhir, V. Self, B.G. Pollet, A. Ingram, W. Bujalski, High temperature (HT) polymer electrolyte membrane fuel cells (PEMFC)-A review, J. Power Sources. 231 (2013) 264–278. https://doi.org/10.1016/j.jpowsour.2012.11.126. [3] R. Haider, Y. Wen, Z.-F. Ma, D.P. Wilkinson, L. Zhang, X. Yuan, S. Song, J. Zhang, High temperature proton exchange membrane fuel cells: progress in advanced materials and key technologies, Chem. Soc. Rev. (2021). https://doi.org/10.1039/d0cs00296h. Figure Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (38) , 1841
Investigating Proton Exchange Membrane Fuel Cell Durability at Intermediate Temperatures (80 – 120 °C)
For several applications the low operating temperature of 60-80 °C of proton exchange membrane fuel cells (PEMFCs) limit their potential use. Increasing this temperature above 100 °C would simplify the water management and increase the temperature of the produced heat which would allow for more effective cooling systems [1,2]. Further, increasing the operating temperature could potentially allow for other benefits, such as the employment of more affordable catalysts, as the reaction kinetics are enhanced at elevated temperatures. However, operating at higher temperatures can cause increased degradation on the utilized components [3]. In this work we investigated how commercial proton exchange membrane electrode assemblies (MEA) aged at various temperatures when operating either using a load cycle (based on the New European Drive Cycle) or constant load. The state of health of the MEA was continuously monitored through cyclic voltammetry, electrochemical impedance spectroscopy, linear sweep voltammetry, CO-stripping measurements and polarization curves. The obtained ageing results were evaluated using a physics-based model using COMSOL to better understand what aging mechanisms were pronounced at higher operating temperatures. Finally, the aged MEA were characterized with SEM and TEM analysis. The results show that all samples underwent an ageing process and that the ageing was accelerated at higher temperatures, as can be seen in the figure . Further, the ageing was more pronounced at a higher load. The measurements showed that the main ageing is occurring at the cathode catalyst layer and a drastic reduction in the electrochemical active surface area of the catalyst was observed. The membrane properties were also altered by the ageing, and a minor reduction in the membrane conductivity was observed. Surprisingly, no significant increase in the hydrogen crossover was observed, suggesting that the elevated temperature does not cause significant pinhole formation. The results shed light on the rate and mechanisms for ageing at various temperatures and can be used to determine the cost and benefits of operating at elevated temperatures. References [1] R.E. Rosli, A.B. Sulong, W.R.W. Daud, M.A. Zulkifley, T. Husaini, M.I. Rosli, E.H. Majlan, M.A. Haque, A review of high-temperature proton exchange membrane fuel cell (HT-PEMFC) system, Int. J. Hydrogen Energy. 42 (2017) 9293–9314. https://doi.org/10.1016/j.ijhydene.2016.06.211. [2] A. Chandan, M. Hattenberger, A. El-Kharouf, S. Du, A. Dhir, V. Self, B.G. Pollet, A. Ingram, W. Bujalski, High temperature (HT) polymer electrolyte membrane fuel cells (PEMFC)-A review, J. Power Sources. 231 (2013) 264–278. https://doi.org/10.1016/j.jpowsour.2012.11.126. [3] R. Haider, Y. Wen, Z.-F. Ma, D.P. Wilkinson, L. Zhang, X. Yuan, S. Song, J. Zhang, High temperature proton exchange membrane fuel cells: progress in advanced materials and key technologies, Chem. Soc. Rev. (2021). https://doi.org/10.1039/d0cs00296h. Figure Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (39) , 1909
Evaluation of Hydrogen Crossover in Pemfcs at Intermediate Temperature (80 - 120 °C)
Proton Exchange Membrane Fuel Cells (PEMFCs) are promising for heavy-duty vehicles (HDV) in the strive to make the transportation sector more sustainable. However, because of the small temperature gradient between the cell (typically run around 80°C) and the ambient temperature, these cells require a large cooling system. Raising the operating temperature to an intermediate temperature range (IT: 80 – 120 °C) would reduce the cooling system size required in HDVs and improve the tolerance towards contaminants, although higher temperature may accelerate degradation [1,2]. To be able to withstand IT operation, reinforcements and chemical modifications have been implemented in commercial PFSA polymers. Unfortunately, most of the data available for PEMFCs are referred to non-reinforced membranes and only few studies analysed the latter under realistic operating conditions. Among some possible issues regarding proton exchange membranes (PEMs), hydrogen crossover is an undesirable, but inevitable phenomenon. The membrane is not perfectly impermeable to hydrogen gas and this results in a safety concern, lower cell efficiency and can lead to faster cell degradation. This work investigates the influence of the reinforcement in a PEM on the hydrogen crossover. Specifically, Nafion HP (reinforced) and Nafion 211 (non-reinforced) are compared under different operating conditions. The purpose of the reinforcement is to improve thermo-mechanical stability, and its physical properties can differ from the rest of the membrane, which can influence hydrogen crossover. Using electrochemical methods, the hydrogen crossover is measured in-situ in a PEMFC with hydrogen on one side and inert gas on the other side. The measurements have been performed between 80 and 120 °C, at different cell relative humidity (RH) conditions (20-90 %) and multiple levels of pressure for both reinforced and non-reinforced membranes. Particular attention has been paid to the case in which the hydrogen side of the cell is more pressurized than the inert side, as this is most often the case in HDV applications. In such conditions, hydrogen permeation increases considerably as a result of the total pressure gradient over the membrane, although this factor is rarely considered in the literature [3]. By adapting the methodology established in our previous work [4], here the effects of the differential total pressure and hydrogen partial pressures are decoupled through a systematic dilution of the hydrogen gas stream. Special points are measured in which the hydrogen partial pressure is kept equal to the ambient case, while the total pressure on the hydrogen side is increased by adding the inert gas, as shown in Figure 1, plot I. Results show that the presence of a reinforcement affects the amount of hydrogen that crosses through the membrane, as seen in Figure 1. Moreover, among the different conditions tested, higher total pressures, especially on the hydrogen side of the cell, are affecting hydrogen crossover the most, while a more modest change is observed for different RH and cell temperatures. The observation that pressure is the most important factor for hydrogen crossover has noteworthy implications and should have an influence when deciding at which pressure the PEMFC is operated in transportation applications. Minimizing hydrogen crossover, while still ensuring adequate cell performance, should be a priority to improve the overall fuel consumption and the electric power obtained from the fuel cell. Figure 1: Hydrogen crossover due to concentration gradients and, in certain conditions, to a differential total pressure. Three different conditions are used to measure crossover, whose results are reported in the right figure: I) the total pressure on the hydrogen side is increased by diluting with inert gas, while the hydrogen partial pressure is kept constant, the inert side is unvaried; II) the total pressure is increased symmetrically on both sides, the hydrogen side is not diluted; III) the total pressure on the hydrogen side is increased and no dilution is employed. [1] Cullen et al., “New roads and challenges for fuel cells in heavy-duty transportation,” Nat. Energy, 2021, doi:10.1038/s41560-021-00775-z. [2] Akitomo et al., “Investigation of effects of high temperature and pressure on a polymer electrolyte fuel cell with polarization analysis and X-ray imaging of liquid water,” J. Power Sources, 2019, doi:10.1016/j.jpowsour.2019.04.115. [3] Kreitmeier et al., “Investigation of membrane degradation in polymer electrolyte fuel cells using local gas permeation analysis,” J. Power Sources, 2012, doi:10.1016/j.jpowsour.2012.03.071. [4] Butori et al., “The Effect of Oxygen Partial Pressure and Humidification in Proton Exchange Membrane Fuel Cells at Intermediate Temperature,” J. Power Sources, 2023, doi:10.1016/j.jpowsour.2023.232803. Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (39) , 1909
Evaluation of Hydrogen Crossover in Pemfcs at Intermediate Temperature (80 - 120 °C)
Proton Exchange Membrane Fuel Cells (PEMFCs) are promising for heavy-duty vehicles (HDV) in the strive to make the transportation sector more sustainable. However, because of the small temperature gradient between the cell (typically run around 80°C) and the ambient temperature, these cells require a large cooling system. Raising the operating temperature to an intermediate temperature range (IT: 80 – 120 °C) would reduce the cooling system size required in HDVs and improve the tolerance towards contaminants, although higher temperature may accelerate degradation [1,2]. To be able to withstand IT operation, reinforcements and chemical modifications have been implemented in commercial PFSA polymers. Unfortunately, most of the data available for PEMFCs are referred to non-reinforced membranes and only few studies analysed the latter under realistic operating conditions. Among some possible issues regarding proton exchange membranes (PEMs), hydrogen crossover is an undesirable, but inevitable phenomenon. The membrane is not perfectly impermeable to hydrogen gas and this results in a safety concern, lower cell efficiency and can lead to faster cell degradation. This work investigates the influence of the reinforcement in a PEM on the hydrogen crossover. Specifically, Nafion HP (reinforced) and Nafion 211 (non-reinforced) are compared under different operating conditions. The purpose of the reinforcement is to improve thermo-mechanical stability, and its physical properties can differ from the rest of the membrane, which can influence hydrogen crossover. Using electrochemical methods, the hydrogen crossover is measured in-situ in a PEMFC with hydrogen on one side and inert gas on the other side. The measurements have been performed between 80 and 120 °C, at different cell relative humidity (RH) conditions (20-90 %) and multiple levels of pressure for both reinforced and non-reinforced membranes. Particular attention has been paid to the case in which the hydrogen side of the cell is more pressurized than the inert side, as this is most often the case in HDV applications. In such conditions, hydrogen permeation increases considerably as a result of the total pressure gradient over the membrane, although this factor is rarely considered in the literature [3]. By adapting the methodology established in our previous work [4], here the effects of the differential total pressure and hydrogen partial pressures are decoupled through a systematic dilution of the hydrogen gas stream. Special points are measured in which the hydrogen partial pressure is kept equal to the ambient case, while the total pressure on the hydrogen side is increased by adding the inert gas, as shown in Figure 1, plot I. Results show that the presence of a reinforcement affects the amount of hydrogen that crosses through the membrane, as seen in Figure 1. Moreover, among the different conditions tested, higher total pressures, especially on the hydrogen side of the cell, are affecting hydrogen crossover the most, while a more modest change is observed for different RH and cell temperatures. The observation that pressure is the most important factor for hydrogen crossover has noteworthy implications and should have an influence when deciding at which pressure the PEMFC is operated in transportation applications. Minimizing hydrogen crossover, while still ensuring adequate cell performance, should be a priority to improve the overall fuel consumption and the electric power obtained from the fuel cell. Figure 1: Hydrogen crossover due to concentration gradients and, in certain conditions, to a differential total pressure. Three different conditions are used to measure crossover, whose results are reported in the right figure: I) the total pressure on the hydrogen side is increased by diluting with inert gas, while the hydrogen partial pressure is kept constant, the inert side is unvaried; II) the total pressure is increased symmetrically on both sides, the hydrogen side is not diluted; III) the total pressure on the hydrogen side is increased and no dilution is employed. [1] Cullen et al., “New roads and challenges for fuel cells in heavy-duty transportation,” Nat. Energy, 2021, doi:10.1038/s41560-021-00775-z. [2] Akitomo et al., “Investigation of effects of high temperature and pressure on a polymer electrolyte fuel cell with polarization analysis and X-ray imaging of liquid water,” J. Power Sources, 2019, doi:10.1016/j.jpowsour.2019.04.115. [3] Kreitmeier et al., “Investigation of membrane degradation in polymer electrolyte fuel cells using local gas permeation analysis,” J. Power Sources, 2012, doi:10.1016/j.jpowsour.2012.03.071. [4] Butori et al., “The Effect of Oxygen Partial Pressure and Humidification in Proton Exchange Membrane Fuel Cells at Intermediate Temperature,” J. Power Sources, 2023, doi:10.1016/j.jpowsour.2023.232803. Figure 1
- Open Access
- 21 February 2023
- Published by Elsevier in Journal of Power Sources
- Vol. 563
The effect of oxygen partial pressure and humidification in proton exchange membrane fuel cells at intermediate temperature (80–120 °C)
- 21 February 2023
- Published by Elsevier in Journal of Power Sources
- Vol. 563
Open AccessThe effect of oxygen partial pressure and humidification in proton exchange membrane fuel cells at intermediate temperature (80–120 °C)