Tengjun Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tengjun Guo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Guoming Ma
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
4 shared publications - Jing Hu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Sihan Wang
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
3 shared publications - Weiqi Qin
Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
3 shared publications Hao Liu
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China
1 shared publication- Hao Liu
North China Electric Power University
1 shared publication
Latest Publications
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Improving SNR and Sensing Distance of COTDR for Distributed Partial Discharge Detection in Power Cable Joints
Distributed detection of partial discharge (PD) in joints of long power cables is both a necessity and a challenge. In order to improve the distance and sensitivity of PD detection, an improved coherent optical time domain reflectometer (COTDR) system is proposed in this paper. A two-stage optical amplification scheme was established, and the pump currents of erbium-doped fiber amplifiers (EDFAs) were optimized to improve the signal-to-noise ratio (SNR) of the beat signal. The dual-frequency probe pulses were introduced to suppress fading noises in the distance-domain and prevent false positives in PD detection. The test results based on real cable joints indicated that the system enabled distributed detection and accurate waveform retrieval of PD events. Based on the above improvements, the proposed system enhanced the PD sensing performance from the existing 1 km sensing distance and nC-level detection limit to 20 km and 127 pC, respectively. This performance indicated that the COTDR system possessed practicality in the distributed detection of cable joints PDs.
- 26 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Improving SNR and Sensing Distance of COTDR for Distributed Partial Discharge Detection in Power Cable Joints
Distributed detection of partial discharge (PD) in joints of long power cables is both a necessity and a challenge. In order to improve the distance and sensitivity of PD detection, an improved coherent optical time domain reflectometer (COTDR) system is proposed in this paper. A two-stage optical amplification scheme was established, and the pump currents of erbium-doped fiber amplifiers (EDFAs) were optimized to improve the signal-to-noise ratio (SNR) of the beat signal. The dual-frequency probe pulses were introduced to suppress fading noises in the distance-domain and prevent false positives in PD detection. The test results based on real cable joints indicated that the system enabled distributed detection and accurate waveform retrieval of PD events. Based on the above improvements, the proposed system enhanced the PD sensing performance from the existing 1 km sensing distance and nC-level detection limit to 20 km and 127 pC, respectively. This performance indicated that the COTDR system possessed practicality in the distributed detection of cable joints PDs.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2977-2980
Distributed Detection and Acoustic Emission Waveform Retrieval of Cable Joint Partial Discharge
Distributed detection and acoustic emission (AE) waveform retrieval of partial discharge (PD) in power cable joints are significant but challenging tasks. In this paper, we proposed a cable joint PD detection method based on optical fiber distributed acoustic sensing (DAS). Ordinary single-mode optical fiber (SMF) was wound on the outer semiconductive layer to obtain sufficient sensitivity. Coherent optical time domain reflection (COTDR) principle was utilized to detect the phase variation and locate the PDs. The AE waveforms were retrieved by Fourier integration and difference operation. The experimental results indicated that the sensing system had the ability of multi-point monitoring. The PD AE waveforms caused by conductor spike and insulation air gap defects were accurately retrieved.
- 15 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (4) , 2977-2980
Distributed Detection and Acoustic Emission Waveform Retrieval of Cable Joint Partial Discharge
Distributed detection and acoustic emission (AE) waveform retrieval of partial discharge (PD) in power cable joints are significant but challenging tasks. In this paper, we proposed a cable joint PD detection method based on optical fiber distributed acoustic sensing (DAS). Ordinary single-mode optical fiber (SMF) was wound on the outer semiconductive layer to obtain sufficient sensitivity. Coherent optical time domain reflection (COTDR) principle was utilized to detect the phase variation and locate the PDs. The AE waveforms were retrieved by Fourier integration and difference operation. The experimental results indicated that the sensing system had the ability of multi-point monitoring. The PD AE waveforms caused by conductor spike and insulation air gap defects were accurately retrieved.
- 21 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Distributed Discharge Detection Based on Improved COTDR Method With Dual Frequency Pulses
Optical fiber distributed acoustic sensing (DAS) is a potential approach to realize on-line monitoring and rapid localization of power cable partial discharges. Distributed detection of discharges requires a DAS system with a wide frequency band and low noise level. For this purpose, an improved coherent optical time-domain reflectometry (COTDR) method based on dual-frequency probe pulses was developed. The method doubled the length-bandwidth product (LBP) of traditional DAS systems without significantly increasing the complexity of signal demodulation. A discharge signal extraction algorithm was also proposed based on the detection results of the dual-frequency pulses to exclude the effects of fading noises and vibrations. The improved COTDR system demonstrated the frequency band extension by detecting and recovering the 50 kHz sinusoidal vibration. The sensing distance was 1.1 km and the spatial resolution was 7.15 m. Afterwards, the multi-point weak spark discharge acoustic signals were correctly measured and localized, and the frequency components up to 71.36 kHz were detected. The proposed COTDR method provides a prospective solution of distributed partial discharge detection for power cables.
- 21 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Distributed Discharge Detection Based on Improved COTDR Method With Dual Frequency Pulses
Optical fiber distributed acoustic sensing (DAS) is a potential approach to realize on-line monitoring and rapid localization of power cable partial discharges. Distributed detection of discharges requires a DAS system with a wide frequency band and low noise level. For this purpose, an improved coherent optical time-domain reflectometry (COTDR) method based on dual-frequency probe pulses was developed. The method doubled the length-bandwidth product (LBP) of traditional DAS systems without significantly increasing the complexity of signal demodulation. A discharge signal extraction algorithm was also proposed based on the detection results of the dual-frequency pulses to exclude the effects of fading noises and vibrations. The improved COTDR system demonstrated the frequency band extension by detecting and recovering the 50 kHz sinusoidal vibration. The sensing distance was 1.1 km and the spatial resolution was 7.15 m. Afterwards, the multi-point weak spark discharge acoustic signals were correctly measured and localized, and the frequency components up to 71.36 kHz were detected. The proposed COTDR method provides a prospective solution of distributed partial discharge detection for power cables.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fire Ignition Mechanism and Extinguishing Method of Cable in High Voltage Switchgear
In recent years, several serious fire disasters have occurred in high-voltage switchgear. The fire ignition mechanism and extinguishing method is not obtained. Because it is difficult to carry out the cable combustion test in full-size high-voltage switchgear. In this paper, a full-size test platform was built, and the temperature distribution of a switchgear during the electrical induced fire ignition was recorded. Secondly, the simulation model of the switchgear was constructed and the law of fire spread was mastered. Then, the process of cable material decomposition and the effect of material decomposition on cable combustion were analyzed. Finally, the start threshold of a fire extinguishing device was determined based on the temperature field distribution in the test. The results provide a reference for the design of fire extinguishing devices in high voltage switchgear.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Fire Ignition Mechanism and Extinguishing Method of Cable in High Voltage Switchgear
In recent years, several serious fire disasters have occurred in high-voltage switchgear. The fire ignition mechanism and extinguishing method is not obtained. Because it is difficult to carry out the cable combustion test in full-size high-voltage switchgear. In this paper, a full-size test platform was built, and the temperature distribution of a switchgear during the electrical induced fire ignition was recorded. Secondly, the simulation model of the switchgear was constructed and the law of fire spread was mastered. Then, the process of cable material decomposition and the effect of material decomposition on cable combustion were analyzed. Finally, the start threshold of a fire extinguishing device was determined based on the temperature field distribution in the test. The results provide a reference for the design of fire extinguishing devices in high voltage switchgear.