HKHyunggug Kim

Hyunggug Kim

*This is an algorithmically generated author record based on publicly available information.

Hyunggug Kim has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Accuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study

    by Taeyoung Lee, Younghoon Cho, Kwang Su Cha, Jinhwan Jung, Jungim Cho, Hyunggug Kim, Daewoo Kim, Joonki Hong, Dongheon Lee, Moonsik Keum, et al.

    Background: Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. Objective: This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. Methods: The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. Results: The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. Conclusions: Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.


  • Open Access

    Accuracy of 11 Wearable, Nearable, and Airable Consumer Sleep Trackers: Prospective Multicenter Validation Study (Preprint)

    by Taeyoung Lee, Younghoon Cho, Kwang Su Cha, Jinhwan Jung, Jungim Cho, Hyunggug Kim, Daewoo Kim, Joonki Hong, Dongheon Lee, Moonsik Keum, et al.

    BACKGROUND Consumer sleep trackers (CSTs) have gained significant popularity because they enable individuals to conveniently monitor and analyze their sleep. However, limited studies have comprehensively validated the performance of widely used CSTs. Our study therefore investigated popular CSTs based on various biosignals and algorithms by assessing the agreement with polysomnography. OBJECTIVE This study aimed to validate the accuracy of various types of CSTs through a comparison with in-lab polysomnography. Additionally, by including widely used CSTs and conducting a multicenter study with a large sample size, this study seeks to provide comprehensive insights into the performance and applicability of these CSTs for sleep monitoring in a hospital environment. METHODS The study analyzed 11 commercially available CSTs, including 5 wearables (Google Pixel Watch, Galaxy Watch 5, Fitbit Sense 2, Apple Watch 8, and Oura Ring 3), 3 nearables (Withings Sleep Tracking Mat, Google Nest Hub 2, and Amazon Halo Rise), and 3 airables (SleepRoutine, SleepScore, and Pillow). The 11 CSTs were divided into 2 groups, ensuring maximum inclusion while avoiding interference between the CSTs within each group. Each group (comprising 8 CSTs) was also compared via polysomnography. RESULTS The study enrolled 75 participants from a tertiary hospital and a primary sleep-specialized clinic in Korea. Across the 2 centers, we collected a total of 3890 hours of sleep sessions based on 11 CSTs, along with 543 hours of polysomnography recordings. Each CST sleep recording covered an average of 353 hours. We analyzed a total of 349,114 epochs from the 11 CSTs compared with polysomnography, where epoch-by-epoch agreement in sleep stage classification showed substantial performance variation. More specifically, the highest macro F1 score was 0.69, while the lowest macro F1 score was 0.26. Various sleep trackers exhibited diverse performances across sleep stages, with SleepRoutine excelling in the wake and rapid eye movement stages, and wearables like Google Pixel Watch and Fitbit Sense 2 showing superiority in the deep stage. There was a distinct trend in sleep measure estimation according to the type of device. Wearables showed high proportional bias in sleep efficiency, while nearables exhibited high proportional bias in sleep latency. Subgroup analyses of sleep trackers revealed variations in macro F1 scores based on factors, such as BMI, sleep efficiency, and apnea-hypopnea index, while the differences between male and female subgroups were minimal. CONCLUSIONS Our study showed that among the 11 CSTs examined, specific CSTs showed substantial agreement with polysomnography, indicating their potential application in sleep monitoring, while other CSTs were partially consistent with polysomnography. This study offers insights into the strengths of CSTs within the 3 different classes for individuals interested in wellness who wish to understand and proactively manage their own sleep.

  • Open Access

    Real-Time Detection of Sleep Apnea Based on Breathing Sounds and Prediction Reinforcement Using Home Noises: Algorithm Development and Validation

    by Vu Linh Le, Daewoo Kim, Eunsung Cho, Hyeryung Jang, Roben Delos Reyes, Hyunggug Kim, Dongheon Lee, In-Young Yoon, Joonki Hong, Jeong-Whun Kim

    Background: Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. Objective: The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. Methods: This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as “apnea,” “hypopnea,” or “no-event,” and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). Results: Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for “no-event,” 84% for “apnea,” and 51% for “hypopnea.” Most misclassifications were made for “hypopnea,” with 15% and 34% of “hypopnea” being wrongly predicted as “apnea” and “no-event,” respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. Conclusions: Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.


  • Open Access

    Real-Time Detection of Sleep Apnea Based on Breathing Sounds and Prediction Reinforcement Using Home Noises: Algorithm Development and Validation (Preprint)

    by Vu Linh Le, Daewoo Kim, Eunsung Cho, Hyeryung Jang, Roben Delos Reyes, Hyunggug Kim, Dongheon Lee, In-Young Yoon, Joonki Hong, Jeong-Whun Kim

    BACKGROUND Multinight monitoring can be helpful for the diagnosis and management of obstructive sleep apnea (OSA). For this purpose, it is necessary to be able to detect OSA in real time in a noisy home environment. Sound-based OSA assessment holds great potential since it can be integrated with smartphones to provide full noncontact monitoring of OSA at home. OBJECTIVE The purpose of this study is to develop a predictive model that can detect OSA in real time, even in a home environment where various noises exist. METHODS This study included 1018 polysomnography (PSG) audio data sets, 297 smartphone audio data sets synced with PSG, and a home noise data set containing 22,500 noises to train the model to predict breathing events, such as apneas and hypopneas, based on breathing sounds that occur during sleep. The whole breathing sound of each night was divided into 30-second epochs and labeled as “apnea,” “hypopnea,” or “no-event,” and the home noises were used to make the model robust to a noisy home environment. The performance of the prediction model was assessed using epoch-by-epoch prediction accuracy and OSA severity classification based on the apnea-hypopnea index (AHI). RESULTS Epoch-by-epoch OSA event detection showed an accuracy of 86% and a macro F1-score of 0.75 for the 3-class OSA event detection task. The model had an accuracy of 92% for “no-event,” 84% for “apnea,” and 51% for “hypopnea.” Most misclassifications were made for “hypopnea,” with 15% and 34% of “hypopnea” being wrongly predicted as “apnea” and “no-event,” respectively. The sensitivity and specificity of the OSA severity classification (AHI≥15) were 0.85 and 0.84, respectively. CONCLUSIONS Our study presents a real-time epoch-by-epoch OSA detector that works in a variety of noisy home environments. Based on this, additional research is needed to verify the usefulness of various multinight monitoring and real-time diagnostic technologies in the home environment.

  • Open Access

    The impact of CT image parameters and skull heterogeneity modeling on the accuracy of transcranial focused ultrasound simulations

    by Hazael Montanaro, Cristina Pasquinelli, Hyunjoo J Lee, Hyunggug Kim, Hartwig R Siebner, Niels Kuster, Axel Thielscher, Esra Neufeld

    Objective . Low-intensity transcranial ultrasound stimulation (TUS) is a promising non-invasive brain stimulation (NIBS) technique. TUS can reach deeper areas and target smaller regions in the brain than other NIBS techniques, but its application in humans is hampered by the lack of a straightforward and reliable procedure to predict the induced ultrasound exposure. Here, we examined how skull modeling affects computer simulations of TUS. Approach . We characterized the ultrasonic beam after transmission through a sheep skull with a hydrophone and performed computed tomography (CT) image-based simulations of the experimental setup. To study the skull model’s impact, we varied: CT acquisition parameters (tube voltage, dose, filter sharpness), image interpolation, segmentation parameters, acoustic property maps (speed-of-sound, density, attenuation), and transducer-position mismatches. We compared the impact of modeling parameter changes on model predictions and on measurement agreement. Spatial-peak intensity and location, total power, and the Gamma metric (a measure for distribution differences) were used as quantitative criteria. Modeling-based sensitivity analysis was also performed for two human head models. Main results . Sheep skull attenuation assignment and transducer positioning had the most important impact on spatial peak intensity (overestimation up to 300%, respectively 30%), followed by filter sharpness and tube voltage (up to 20%), requiring calibration of the mapping functions. Positioning and skull-heterogeneity-structure strongly affected the intensity distribution (gamma tolerances exceeded in > 80%, respectively > 150%, of the focus-volume in water), necessitating image-based personalized modeling. Simulation results in human models consistently demonstrate a high sensitivity to the skull-heterogeneity model, attenuation tuning, and transducer shifts, the magnitude of which depends on the underlying skull structure complexity. Significance . Our study reveals the importance of properly modeling the skull-heterogeneity and its structure and of accurately reproducing the transducer position. The results raise red flags when translating modeling approaches among clinical sites without proper standardization and/or recalibration of the imaging and modeling parameters.


  • Open Access

    Miniaturized ultrasound systems for modulation of sleep of freely moving mice

    by Yehhyun Jo, Sang-Mok Lee, Seongyeon Kim, Hyunggug Kim, Hyunjoo Lee