Dubravko Žigman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dubravko Žigman has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Lonić
Department of Electrical Engineering, Zagreb University of Applied Sciences, Konavoska 2, 10000 Zagreb, Croatia
2 shared publications - Stjepan Tvorić
Department of Electrical Engineering, Zagreb University of Applied Sciences, Konavoska 2, 10000 Zagreb, Croatia
2 shared publications - Krešimir Osman
Department of Electrical Engineering, Zagreb University of Applied Sciences, Zagreb, Croatia
1 shared publication Marija Krznarić
Polytechnic of Zagreb, Zagreb, Croatia1
1 shared publicationSlaven Krajina
Polytechnic of Zagreb, Zagreb, Croatia1
1 shared publication- Tomislav Tomiša
Department of Energy and Power Systems, Faculty of Electrical Engineering and Computing, University of Zagreb, Unska 3, 10 000 Zagreb, Croatia
1 shared publication
Latest Publications
- Open Access
Comparative PSO Optimisation of Microgrid Management Models in Island Operation to Minimise Cost
The rapid progress in renewable energy sources and the increasing complexity of energy distribution networks have highlighted the need for efficient and intelligent energy management systems. This paper presents a comparative analysis of two optimisation algorithms, P and M70, used for the optimal control of the operation of microgrids in islanded mode. The main objective is to minimise production costs while ensuring a reliable energy supply. Algorithm P prioritises the use of photovoltaic (PV) and battery storage and operates the diesel generator at minimum capacity to reduce fuel consumption and maximise the use of renewable energy sources. Algorithm M70, on the other hand, uses a heuristic approach to adaptively manage energy resources in real time. In this study, the performance of both algorithms is evaluated through simulation in different operating scenarios. The results show that both algorithms significantly improve the efficiency of the microgrid, with the M70 algorithm showing better adaptability and cost efficiency in dynamic environments. This research contributes to ongoing efforts to develop robust and scalable energy management systems for future smart grids.
Open AccessComparative PSO Optimisation of Microgrid Management Models in Island Operation to Minimise Cost
The rapid progress in renewable energy sources and the increasing complexity of energy distribution networks have highlighted the need for efficient and intelligent energy management systems. This paper presents a comparative analysis of two optimisation algorithms, P and M70, used for the optimal control of the operation of microgrids in islanded mode. The main objective is to minimise production costs while ensuring a reliable energy supply. Algorithm P prioritises the use of photovoltaic (PV) and battery storage and operates the diesel generator at minimum capacity to reduce fuel consumption and maximise the use of renewable energy sources. Algorithm M70, on the other hand, uses a heuristic approach to adaptively manage energy resources in real time. In this study, the performance of both algorithms is evaluated through simulation in different operating scenarios. The results show that both algorithms significantly improve the efficiency of the microgrid, with the M70 algorithm showing better adaptability and cost efficiency in dynamic environments. This research contributes to ongoing efforts to develop robust and scalable energy management systems for future smart grids.
- Open Access
- 15 July 2024
- Published by MDPI AG in Preprints.org
Comparative PSO Optimization of Microgrid Management Models in Island Operation to Minimise Cost
The rapid progress in renewable energy sources and the increasing complexity of energy distribution networks have highlighted the need for efficient and intelligent energy management systems. This paper presents a comparative analysis of two optimisation algorithms, P and M70, used for the optimal control of the operation of microgrids in islanded mode. The main objective is to minimise production costs while ensuring a reliable energy supply. Algorithm P prioritises the use of photovoltaic (PV) and battery storage and operates the diesel generator at minimum capacity to reduce fuel consumption and maximise the use of renewable energy sources. Algorithm M70, on the other hand, uses a heuristic approach to adaptively manage energy resources in real time. In this study, the performance of both algorithms is evaluated through simulation in different operating scenarios. The results show that both algorithms significantly improve the efficiency of the microgrid, with the M70 algorithm showing better adaptability and cost efficiency in dynamic environments. This research contributes to ongoing efforts to develop robust and scalable energy management systems for future smart grids.
- 15 July 2024
- Published by MDPI AG in Preprints.org
Open AccessComparative PSO Optimization of Microgrid Management Models in Island Operation to Minimise Cost
The rapid progress in renewable energy sources and the increasing complexity of energy distribution networks have highlighted the need for efficient and intelligent energy management systems. This paper presents a comparative analysis of two optimisation algorithms, P and M70, used for the optimal control of the operation of microgrids in islanded mode. The main objective is to minimise production costs while ensuring a reliable energy supply. Algorithm P prioritises the use of photovoltaic (PV) and battery storage and operates the diesel generator at minimum capacity to reduce fuel consumption and maximise the use of renewable energy sources. Algorithm M70, on the other hand, uses a heuristic approach to adaptively manage energy resources in real time. In this study, the performance of both algorithms is evaluated through simulation in different operating scenarios. The results show that both algorithms significantly improve the efficiency of the microgrid, with the M70 algorithm showing better adaptability and cost efficiency in dynamic environments. This research contributes to ongoing efforts to develop robust and scalable energy management systems for future smart grids.
- Open Access
Methodology Presentation for the Configuration Optimization of Hybrid Electrical Energy Systems
The paper presents the methodology that should be used to optimize hybrid power system configurations, i.e., the chosen microgrid scenario. The methodology was developed with the aim of evaluating the different production capacities of a system and comparing them with alternative connections to the main grid. It has a step-by-step structure and includes part of the steps performed by simulations in a computer program. It provides us with not only a basic but also a representative idea of an actual microgrid configuration, which is further used as support in the system’s design. An algorithm has been developed to check the energy flows and correct the selling price. The program HOMER Pro is used as the program support in performing the hybrid optimization simulation. In the analysis, it was found that the maximum share of generation from renewable energy sources in relation to the power grid is 143%, while the share of renewable energy sources in the generated energy is 65.3%. Greenhouse gas emissions are reduced by 40.75% compared to energy generated only from the power grid. In the optimization process, four configurations of the microgrid model with 990 solutions were taken, all of which are feasible.
Open AccessMethodology Presentation for the Configuration Optimization of Hybrid Electrical Energy Systems
The paper presents the methodology that should be used to optimize hybrid power system configurations, i.e., the chosen microgrid scenario. The methodology was developed with the aim of evaluating the different production capacities of a system and comparing them with alternative connections to the main grid. It has a step-by-step structure and includes part of the steps performed by simulations in a computer program. It provides us with not only a basic but also a representative idea of an actual microgrid configuration, which is further used as support in the system’s design. An algorithm has been developed to check the energy flows and correct the selling price. The program HOMER Pro is used as the program support in performing the hybrid optimization simulation. In the analysis, it was found that the maximum share of generation from renewable energy sources in relation to the power grid is 143%, while the share of renewable energy sources in the generated energy is 65.3%. Greenhouse gas emissions are reduced by 40.75% compared to energy generated only from the power grid. In the optimization process, four configurations of the microgrid model with 990 solutions were taken, all of which are feasible.
- Open Access
- 1 December 2009
- Published by Walter de Gruyter GmbH in Archives of Industrial Hygiene and Toxicology
- Vol. 60 (4) , 503-508
Application of Real-Time Locating in Health Care
Application of Real-Time Locating in Health Care: This paper describes real-time locating technology and its possible use in health care. Real time locating may be applied in different segments of everyday life, including hospitals (medical equipment and devices, locating patients, and alarm in case of emergency), working environment (locating persons to control access to restricted areas or in case of fire to see if anyone has been trapped inside the building), sports, logistics, retail trade, and offices. Tagged hospital equipment is easy to trace inside hospital premises and the system makes it possible to track patients and staff, and to redistribute work in particular wards.
- 1 December 2009
- Published by Walter de Gruyter GmbH in Archives of Industrial Hygiene and Toxicology
- Vol. 60 (4) , 503-508
Open AccessApplication of Real-Time Locating in Health Care
Application of Real-Time Locating in Health Care: This paper describes real-time locating technology and its possible use in health care. Real time locating may be applied in different segments of everyday life, including hospitals (medical equipment and devices, locating patients, and alarm in case of emergency), working environment (locating persons to control access to restricted areas or in case of fire to see if anyone has been trapped inside the building), sports, logistics, retail trade, and offices. Tagged hospital equipment is easy to trace inside hospital premises and the system makes it possible to track patients and staff, and to redistribute work in particular wards.