Collins Gameli Hodoli
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Collins Gameli Hodoli has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Carl Malings
Morgan State University
3 shared publications - Daniel McMahon Westervelt
Lamont‐Doherty Earth Observatory Columbia University New York NY USA
2 shared publications - Frederic Coulon
Cranfield University
2 shared publications Iq Mead
MRC Centre for Environment and Health, Environmental Research Group
2 shared publicationsVictor Dzidefo Ablo
2 shared publicationsAchim Haug
AirGradient Ltd
1 shared publication
Latest Publications
- Open Access
- 26 March 2026
- Published by Elsevier in Atmospheric Environment: X
- Vol. 30
The potential of micro air sensors for democratizing air quality monitoring and mirroring air pollution at schools using citizen science
- 26 March 2026
- Published by Elsevier in Atmospheric Environment: X
- Vol. 30
Open AccessThe potential of micro air sensors for democratizing air quality monitoring and mirroring air pollution at schools using citizen science
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Sensors as a component of urban air quality management planning: a case study with AirGradient OpenAir PM monitors from Accra, Ghana.
Millions of premature deaths across Africa every year are attributed to air pollution. Of specific mention is exposure to fine particles, PM2.5. We present in this study a novel concept using the non-parametric wind regression approach and low-capital-cost (LCC) air sensor data to identify sources of PM2.5 pollution. This study is based on PM2.5 data collected at the University of Ghana (Afri-Set), Accra using the AirGradient OpenAir PM2.5 monitor from June 01 to September 15, 2023. Using the raw, calibrated, and regulatory grade data from the Teledyne API PM Mass Monitor T640, we found a good agreement between the identified sources of PM2.5. Additionally, we observed that high PM2.5 levels (21 µgm-3) were experienced during S, W, SW and SE winds. At low wind speeds (≤ 1 ms-1), PM2.5 pollution was high suggesting a possible local source. Although there were differences in concentrations comparing the raw and the reference grade data, our results showed that PM2.5 sources were similar. A diurnal pattern of the observed PM2.5 also shows a high similarity between the 3 sets of data. Peak levels (15-20 µgm-3) were observed at 07:00 to 14:00 hrs and 18:00 to 23:00 hrs associated with SW winds. Between 00:00 and 04:00 hrs, low levels (below 15 µgm-3) were observed and associated with W and SW winds. Southerly observations were below 15 µgm-3 with high levels (15-20 µgm-3) easterly between 04:00 and 08:00 hrs. This indicates that the raw data from the LCC PM air sensor is suitable for developing and tracking air pollution mitigation strategies, especially in environments with similar characteristics, with some caveats. We recommend a further investigation of the site tied to prevailing background activities to provide a vivid understanding of the potential contributing factors from the observed wind directions.Keywords: Air Pollution; Source Identification; Air Sensors; Ghana; PM2.5
- 20 January 2025
- Published by Copernicus GmbH
Open AccessSensors as a component of urban air quality management planning: a case study with AirGradient OpenAir PM monitors from Accra, Ghana.
Millions of premature deaths across Africa every year are attributed to air pollution. Of specific mention is exposure to fine particles, PM2.5. We present in this study a novel concept using the non-parametric wind regression approach and low-capital-cost (LCC) air sensor data to identify sources of PM2.5 pollution. This study is based on PM2.5 data collected at the University of Ghana (Afri-Set), Accra using the AirGradient OpenAir PM2.5 monitor from June 01 to September 15, 2023. Using the raw, calibrated, and regulatory grade data from the Teledyne API PM Mass Monitor T640, we found a good agreement between the identified sources of PM2.5. Additionally, we observed that high PM2.5 levels (21 µgm-3) were experienced during S, W, SW and SE winds. At low wind speeds (≤ 1 ms-1), PM2.5 pollution was high suggesting a possible local source. Although there were differences in concentrations comparing the raw and the reference grade data, our results showed that PM2.5 sources were similar. A diurnal pattern of the observed PM2.5 also shows a high similarity between the 3 sets of data. Peak levels (15-20 µgm-3) were observed at 07:00 to 14:00 hrs and 18:00 to 23:00 hrs associated with SW winds. Between 00:00 and 04:00 hrs, low levels (below 15 µgm-3) were observed and associated with W and SW winds. Southerly observations were below 15 µgm-3 with high levels (15-20 µgm-3) easterly between 04:00 and 08:00 hrs. This indicates that the raw data from the LCC PM air sensor is suitable for developing and tracking air pollution mitigation strategies, especially in environments with similar characteristics, with some caveats. We recommend a further investigation of the site tied to prevailing background activities to provide a vivid understanding of the potential contributing factors from the observed wind directions.Keywords: Air Pollution; Source Identification; Air Sensors; Ghana; PM2.5
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Application of air sensors to support clean cooking initiatives at education centres in low- and middle-income countries using Accra High School, Ghana as a case study.
Miniaturised air sensors (otherwise known as “small sensors”, “low cost sensors” or “lower capital cost sensors”) have been used extensively for air quality campaigns globally primarily as pilot studies. To date, their usefulness for applications to generate robust evidence for social intervention programmes, especially in geographies with poor environmental and social policies (such as those encountered in many parts of the global south), is limited. This study focused on the application of air sensor data to produce evidence to support interventions such as clean cooking initiatives at education centres in low- and middle-income countries using Accra High School located in the city of Accra, Ghana as a case study. We deployed a calibrated Airnote PM2.5 air sensor at Accra High School from June 01st to July 23rd, 2023. We employed time series, calendar and diurnal variation analysis to present the reported data. We found that 24-hour PM2.5 pollution was 7 times higher than the World Health Organization Air Quality Guidelines. The calendar plots show that cooking staff, predominantly women, are routinely exposed to unhealthy, very unhealthy or hazardous levels of PM2.5, a species linked to the incidence of asthma, COPD, heart disease, cancers and increasingly poor birth outcomes and dementia. Peak levels (~140 µgm-3) were observed between 06:00 and 18:00 hrs and are linked to cooking activity with charcoal and fuelwood. Hourly PM2.5 concentration ~300 µgm-3 was also periodically observed. These preliminary results were presented to the member of Parliament, Hon Dr Zanetor Agymang-Rawlings in whose jurisdiction the study was collaboratively conducted. Per the recommendations, a clean cooking initiative was launched with the replacement of old cooking appliances. This study illustrates the usefulness and application of air sensors to support clean cooking initiatives in environments with poor energy sources for cooking and heating. This is a directly reproducible approach which is possible to implement across many areas of continental Africa. We recommend the implementation of continuous air quality measurements at and around cooking areas to understand the impacts of newer more efficient cooking appliances on local air quality. We also recommend the use of the data for air pollution and sustainability science education at the Accra High School or in similar settings with air sensor campaigns.
- 20 January 2025
- Published by Copernicus GmbH
Open AccessApplication of air sensors to support clean cooking initiatives at education centres in low- and middle-income countries using Accra High School, Ghana as a case study.
Miniaturised air sensors (otherwise known as “small sensors”, “low cost sensors” or “lower capital cost sensors”) have been used extensively for air quality campaigns globally primarily as pilot studies. To date, their usefulness for applications to generate robust evidence for social intervention programmes, especially in geographies with poor environmental and social policies (such as those encountered in many parts of the global south), is limited. This study focused on the application of air sensor data to produce evidence to support interventions such as clean cooking initiatives at education centres in low- and middle-income countries using Accra High School located in the city of Accra, Ghana as a case study. We deployed a calibrated Airnote PM2.5 air sensor at Accra High School from June 01st to July 23rd, 2023. We employed time series, calendar and diurnal variation analysis to present the reported data. We found that 24-hour PM2.5 pollution was 7 times higher than the World Health Organization Air Quality Guidelines. The calendar plots show that cooking staff, predominantly women, are routinely exposed to unhealthy, very unhealthy or hazardous levels of PM2.5, a species linked to the incidence of asthma, COPD, heart disease, cancers and increasingly poor birth outcomes and dementia. Peak levels (~140 µgm-3) were observed between 06:00 and 18:00 hrs and are linked to cooking activity with charcoal and fuelwood. Hourly PM2.5 concentration ~300 µgm-3 was also periodically observed. These preliminary results were presented to the member of Parliament, Hon Dr Zanetor Agymang-Rawlings in whose jurisdiction the study was collaboratively conducted. Per the recommendations, a clean cooking initiative was launched with the replacement of old cooking appliances. This study illustrates the usefulness and application of air sensors to support clean cooking initiatives in environments with poor energy sources for cooking and heating. This is a directly reproducible approach which is possible to implement across many areas of continental Africa. We recommend the implementation of continuous air quality measurements at and around cooking areas to understand the impacts of newer more efficient cooking appliances on local air quality. We also recommend the use of the data for air pollution and sustainability science education at the Accra High School or in similar settings with air sensor campaigns.
- Open Access
- 6 November 2024
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (2) , 201-214
Urban Air Quality Management at Low Cost Using Micro Air Sensors: A Case Study from Accra, Ghana
Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to nonexistent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors, which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was colocated at the Physics Department, University of Ghana, with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of these data in identification of local sources and their behavior over time. For this study, 15 weeks of data at hourly resolution with approximately 2500 data pairs were generated and analyzed (June 1, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μg m-3 between the pre local calibration micro air sensor (i.e., out of the box) and the reference-grade instrument. Following currently accepted best practice methods (see, e.g., PAS4023) a domain specific (i.e., local) calibration factor was generated using a multilinear regression model, and when this factor is applied to the micro air sensor data, a reduction, i.e. improvement, in MAE to 1.43 μg m-3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots, to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of the box, domain calibrated, and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyperlocalized sources associated with urban areas, such as those found in major African cities.
- 6 November 2024
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (2) , 201-214
Open AccessUrban Air Quality Management at Low Cost Using Micro Air Sensors: A Case Study from Accra, Ghana
Urban air quality management is dependent on the availability of local air pollution data. In many major urban centers of Africa, there is limited to nonexistent information on air quality. This is gradually changing in part due to the increasing use of micro air sensors, which have the potential to enable the generation of ground-based air quality data at fine scales for understanding local emission trends. Regional literature on the application of high-resolution data for emission source identification in this region is limited. In this study a micro air sensor was colocated at the Physics Department, University of Ghana, with a reference grade instrument to evaluate its performance for estimating PM2.5 pollution accurately at fine scales and the value of these data in identification of local sources and their behavior over time. For this study, 15 weeks of data at hourly resolution with approximately 2500 data pairs were generated and analyzed (June 1, 2023, to September 15, 2023). For this time period a coefficient of determination (r 2) of 0.83 was generated with a mean absolute error (MAE) of 5.44 μg m-3 between the pre local calibration micro air sensor (i.e., out of the box) and the reference-grade instrument. Following currently accepted best practice methods (see, e.g., PAS4023) a domain specific (i.e., local) calibration factor was generated using a multilinear regression model, and when this factor is applied to the micro air sensor data, a reduction, i.e. improvement, in MAE to 1.43 μg m-3 was found. Daily variation was calculated, a receptor model was applied, and time series plots as a function of wind direction were generated, including PM2.5/PM10 ratio scatter and count plots, to explore the utility of this observational approach for local source identification. The 3 data sets were compared (out of the box, domain calibrated, and reference-grade) and it was found that although there were variations in the data reported, source areas highlighted based on these data were similar, with input from local sources such as traffic emissions and biomass burning. As the temporal resolution of observational data associated with these micro air sensors is higher than for reference grade instruments (primarily due to costs and logistics limitations), they have the potential to provide insight into the complex, often hyperlocalized sources associated with urban areas, such as those found in major African cities.
- Open Access
- 1 July 2024
- Published by Taylor & Francis in Cogent Economics & Finance
- Vol. 12 (1)
Profit as a predictor variable for environmental sustainability practices (ESPs) of manufacturing companies for achieving green manufacturing in contemporary Ghana
- 1 July 2024
- Published by Taylor & Francis in Cogent Economics & Finance
- Vol. 12 (1)
Open AccessProfit as a predictor variable for environmental sustainability practices (ESPs) of manufacturing companies for achieving green manufacturing in contemporary Ghana
- Open Access
- 15 May 2023
- Published by Copernicus GmbH
Enhancing the spatial and temporal resolution of air quality monitoring in low – and middle-income countries using low-cost sensors
Air pollution is one of the leading risk factors for poor health in Africa, resulting in millions of premature deaths and economic losses. Of particular interest is exposure to fine particulate matter (PM2.5) which is the driver for a majority of deaths across the continent. However, PM monitoring, and by extension, ground-level data on PM2.5 is very limited; this limits our understanding of the widespread societal and health impacts linked to PM pollution. The robustness of low-cost PM sensors and their ability to report in situ data in tropical environments via internet-based platforms as well as relative affordability has created the opportunity to employ low-cost sensors (LCS) for air quality monitoring but calibration methodologies and the usefulness of the high-temporal resolution data for source identification remain a challenge. Increasingly, local governments in African countries are also turning to low-cost sensors to monitor air quality. In this study, two Airnote PM monitors were colocated with reference-grade Teledyne PM mass monitor T640 for ~4 weeks at the University of Ghana, Accra to establish their performance using a simplified data correction methodology - multiple linear regression (MLR) model. A split ratio of 80% and 20% was used to train and test the populated Airnote PM2.5 data respectively based on measurements from Teledyne T640 with temperature and relative humidity values from the Airnote monitor. Sectoral and calendar analysis with wind component data were used to triangulate the sources of PM2.5. We observed a high consistency between the two Airnote monitors. Hourly and 24-hour average PM2.5 values ranged from 25 to 95 μg/m3, and 29 to 54 μg/m3 respectively, and in most cases, were significantly higher than the WHO Air Quality Guideline. MLR using Pearson’s correlation analysis improved the out-of-the-box quality of low-cost Airnote PM2.5 data; the R2 improved from 0.69 to 0.84 and the mean absolute error from 11.75 to 4.20 μg/m3 respectively. Also, the MLR correction model was found to improve the Airnote PM2.5 data quality for higher relative humidity (between 50 and 90%) but not lower. PM2.5 pollution was local and from N, NE and SW winds for the raw, corrected and Teledyne PM mass monitor T640 measurements. Together, these results indicate that with appropriate corrections, low-cost PM sensors can generate the much needed data for air pollution research and mitigation in areas with limited air quality monitoring and data.
- 15 May 2023
- Published by Copernicus GmbH
Open AccessEnhancing the spatial and temporal resolution of air quality monitoring in low – and middle-income countries using low-cost sensors
Air pollution is one of the leading risk factors for poor health in Africa, resulting in millions of premature deaths and economic losses. Of particular interest is exposure to fine particulate matter (PM2.5) which is the driver for a majority of deaths across the continent. However, PM monitoring, and by extension, ground-level data on PM2.5 is very limited; this limits our understanding of the widespread societal and health impacts linked to PM pollution. The robustness of low-cost PM sensors and their ability to report in situ data in tropical environments via internet-based platforms as well as relative affordability has created the opportunity to employ low-cost sensors (LCS) for air quality monitoring but calibration methodologies and the usefulness of the high-temporal resolution data for source identification remain a challenge. Increasingly, local governments in African countries are also turning to low-cost sensors to monitor air quality. In this study, two Airnote PM monitors were colocated with reference-grade Teledyne PM mass monitor T640 for ~4 weeks at the University of Ghana, Accra to establish their performance using a simplified data correction methodology - multiple linear regression (MLR) model. A split ratio of 80% and 20% was used to train and test the populated Airnote PM2.5 data respectively based on measurements from Teledyne T640 with temperature and relative humidity values from the Airnote monitor. Sectoral and calendar analysis with wind component data were used to triangulate the sources of PM2.5. We observed a high consistency between the two Airnote monitors. Hourly and 24-hour average PM2.5 values ranged from 25 to 95 μg/m3, and 29 to 54 μg/m3 respectively, and in most cases, were significantly higher than the WHO Air Quality Guideline. MLR using Pearson’s correlation analysis improved the out-of-the-box quality of low-cost Airnote PM2.5 data; the R2 improved from 0.69 to 0.84 and the mean absolute error from 11.75 to 4.20 μg/m3 respectively. Also, the MLR correction model was found to improve the Airnote PM2.5 data quality for higher relative humidity (between 50 and 90%) but not lower. PM2.5 pollution was local and from N, NE and SW winds for the raw, corrected and Teledyne PM mass monitor T640 measurements. Together, these results indicate that with appropriate corrections, low-cost PM sensors can generate the much needed data for air pollution research and mitigation in areas with limited air quality monitoring and data.