Zhuhao Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhuhao Li has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Changgui Yang
College of Integrated Circuits, Zhejiang University, Hangzhou, China
6 shared publications - Yunshan Zhang
College of Integrated Circuits, Zhejiang University, Hangzhou, China
6 shared publications - Yuxuan Luo
College of Integrated Circuits, Zhejiang University, Hangzhou, China
6 shared publications - Bo Zhao
Zhejiang University
5 shared publications - Gang Pan
Zhejiang University, Hangzhou, China
5 shared publications - Huan Gao
Department of Biomedical Engineering, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, Pennsylvania, 15213-3815, UNITED STATES
4 shared publications
Latest Publications
- 19 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (1) , 226-237
Neural Dielet 2.0: A 128-Channel 2mm$\times$2mm Battery-Free Neural Dielet Merging Simultaneous Multi-Channel Transmission Through Multi-Carrier Orthogonal Backscatter
Miniaturization of wireless neural-recording systems enables minimally-invasive surgery and alleviates the rejection reactions for implanted brain-computer interface (BCI) applications. Simultaneous massive-channel recording capability is essential to investigate the behaviors and inter-connections in billions of neurons. In recent years, battery-free techniques based on wireless power transfer (WPT) and backscatter communication have reduced the sizes of neural-recording implants by battery eliminating and antenna sharing. However, the existing battery-free chips realize the multi-channel merging in the signal-acquisition circuits, which leads to large chip area, signal attenuation, insufficient channel number or low bandwidth, etc. In this work, we demonstrate a 2mm×2mm battery-free neural dielet, which merges 128 channels in the wireless part. The neural dielet is fabricated with 65nm CMOS process, and measured results show that: 1) The proposed multi-carrier orthogonal backscatter technique achieves a high data rate of 20.16Mb/s and an energy efficiency of 0.8pJ/bit. 2) A self-calibrated direct digital converter (SC-DDC) is proposed to fit the 128 channels in the 2mm×2mm die, and then the all-digital implementation achieves 0.02mm 2 area and 9.87 μ W power per channel.
- 19 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (1) , 226-237
Neural Dielet 2.0: A 128-Channel 2mm$\times$2mm Battery-Free Neural Dielet Merging Simultaneous Multi-Channel Transmission Through Multi-Carrier Orthogonal Backscatter
Miniaturization of wireless neural-recording systems enables minimally-invasive surgery and alleviates the rejection reactions for implanted brain-computer interface (BCI) applications. Simultaneous massive-channel recording capability is essential to investigate the behaviors and inter-connections in billions of neurons. In recent years, battery-free techniques based on wireless power transfer (WPT) and backscatter communication have reduced the sizes of neural-recording implants by battery eliminating and antenna sharing. However, the existing battery-free chips realize the multi-channel merging in the signal-acquisition circuits, which leads to large chip area, signal attenuation, insufficient channel number or low bandwidth, etc. In this work, we demonstrate a 2mm×2mm battery-free neural dielet, which merges 128 channels in the wireless part. The neural dielet is fabricated with 65nm CMOS process, and measured results show that: 1) The proposed multi-carrier orthogonal backscatter technique achieves a high data rate of 20.16Mb/s and an energy efficiency of 0.8pJ/bit. 2) A self-calibrated direct digital converter (SC-DDC) is proposed to fit the 128 channels in the 2mm×2mm die, and then the all-digital implementation achieves 0.02mm 2 area and 9.87 μ W power per channel.
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (1) , 39-50
A Self-Adaptive Dual-ILRO Clock-Recovery Technique for Two-Tone Battery-Free Crystal-Free Neural-Recording SoC
Wireless implantable devices are widely used in medical treatment, which should meet clinical constraints such as longevity, miniaturization, and reliable communication. Wireless power transfer (WPT) can eliminate the battery to reduce system size and prolong device life, while it's challenging to generate a reliable clock without a crystal. In this work, we propose a self-adaptive dual-injection-locked-ring-oscillator (dual-ILRO) clock-recovery technique based on two-tone WPT and integrate it into a battery-free neural-recording SoC. The 2 $\text{nd}$ -order inter-modulation (IM2) component of the two WPT tones is extracted as a low-frequency reference for battery-free SoC, and the proposed self-adaptive dual-ILRO technique extends the lock range to ensure an anti-interference PVT-robust clock generation. The neural-recording SoC includes a low-noise signal acquisition unit, a power management unit, and a backscatter circuit to perform neural signal recording, wireless power harvesting, and neural data transmission. Benefiting from the 6.4 $\mu$ W low power of the clock recovery circuit, the overall SoC power is cut down to 49.8 $\mu$ W. In addition, the proposed clock-recovery technique enables both signal acquisition and uplink communication to perform as well as that synchronized by an ideal clock, i.e., an effective number of 9.6 bits and a bit error rate (BER) less than 4.8 $\times\, 10^{-7}$ in chip measurement. The SoC takes a die area of 2.05 mm $^{2}$ , and an animal test is conducted in a Sprague-Dawley rat to validate the wireless neural-recording performance, compared to a crystal-synchronized commercial chip.
- 7 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 18 (1) , 39-50
A Self-Adaptive Dual-ILRO Clock-Recovery Technique for Two-Tone Battery-Free Crystal-Free Neural-Recording SoC
Wireless implantable devices are widely used in medical treatment, which should meet clinical constraints such as longevity, miniaturization, and reliable communication. Wireless power transfer (WPT) can eliminate the battery to reduce system size and prolong device life, while it's challenging to generate a reliable clock without a crystal. In this work, we propose a self-adaptive dual-injection-locked-ring-oscillator (dual-ILRO) clock-recovery technique based on two-tone WPT and integrate it into a battery-free neural-recording SoC. The 2 $\text{nd}$ -order inter-modulation (IM2) component of the two WPT tones is extracted as a low-frequency reference for battery-free SoC, and the proposed self-adaptive dual-ILRO technique extends the lock range to ensure an anti-interference PVT-robust clock generation. The neural-recording SoC includes a low-noise signal acquisition unit, a power management unit, and a backscatter circuit to perform neural signal recording, wireless power harvesting, and neural data transmission. Benefiting from the 6.4 $\mu$ W low power of the clock recovery circuit, the overall SoC power is cut down to 49.8 $\mu$ W. In addition, the proposed clock-recovery technique enables both signal acquisition and uplink communication to perform as well as that synchronized by an ideal clock, i.e., an effective number of 9.6 bits and a bit error rate (BER) less than 4.8 $\times\, 10^{-7}$ in chip measurement. The SoC takes a die area of 2.05 mm $^{2}$ , and an animal test is conducted in a Sprague-Dawley rat to validate the wireless neural-recording performance, compared to a crystal-synchronized commercial chip.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (11) , 3194-3206
An 8-Shaped Antenna-Based Battery-Free Neural-Recording System Featuring 3 cm Reading Range and 140 pJ/bit Energy Efficiency
Wireless neural recording is envisaged to be an effective way of monitoring neural behaviors in long term, which requires a miniature device deeply implanted in the brain tissue. Wireless power transfer (WPT) enables neural-recording devices to be battery-free, while it’s challenging to realize a centimeter-level telemetry range through a millimeter-scale implantable antenna. In conventional battery-free wireless techniques, backscatter radios show limited communication range, whereas dual-antenna active radios enlarge the system size. In this work, we proposed a battery-free wireless neural-recording system based on 8-shaped overlapped antennas and a beat impulse radio, taking an overall dimension of 4.7 $\times$ 4.7 mm. The system is implemented in a 65-nm CMOS process, and an animal experiment validates the system performance on a male Sprague-Dawley rat. The proposed system achieves a communication range of 3 cm in a battery-free fully wireless way, where the proposed beat impulse radio shows 140 pJ/bit energy efficiency.
- 7 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (11) , 3194-3206
An 8-Shaped Antenna-Based Battery-Free Neural-Recording System Featuring 3 cm Reading Range and 140 pJ/bit Energy Efficiency
Wireless neural recording is envisaged to be an effective way of monitoring neural behaviors in long term, which requires a miniature device deeply implanted in the brain tissue. Wireless power transfer (WPT) enables neural-recording devices to be battery-free, while it’s challenging to realize a centimeter-level telemetry range through a millimeter-scale implantable antenna. In conventional battery-free wireless techniques, backscatter radios show limited communication range, whereas dual-antenna active radios enlarge the system size. In this work, we proposed a battery-free wireless neural-recording system based on 8-shaped overlapped antennas and a beat impulse radio, taking an overall dimension of 4.7 $\times$ 4.7 mm. The system is implemented in a 65-nm CMOS process, and an animal experiment validates the system performance on a male Sprague-Dawley rat. The proposed system achieves a communication range of 3 cm in a battery-free fully wireless way, where the proposed beat impulse radio shows 140 pJ/bit energy efficiency.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (7) , 2053-2063
A 1 mm ×1 mm CGM System on Die Achieving 1.65-nA/mM In Vivo Resolution and 0–40-mM/L Detection Range With ΔΣ Backscatter Technique
Diabetes has become a leading cause of death and disability all over the world. Continuous glucose monitoring (CGM) based on wireless power transfer (WPT) and backscatter communication enables wireless real-time telemetry to control glycemic levels in a long term. However, conventional backscatter techniques in CGM systems converted the sensing current into a bit stream or a frequency signal to switch the antenna, leading to two drawbacks: 1) Large power-harvesting antennas are required to complement the power loss in data converting and antenna switching and 2) Both the resolution and detection range are limited even with a high-performance glucose sensor. In this work, we propose a$\Delta \Sigma $ backscatter technique to demonstrate a system on die (SoD) within a$1\times1$ -mm on-chip antenna. Implemented in the 65-nm CMOS process, the proposed SoD achieves a telemetry error less than 0.25% with little impact on WPT, as well as a wide detection range of 0–40 mM/L. In vivo experimental results show that the CGM SoD realizes a resolution of 1.65 nA/mM.- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 58 (7) , 2053-2063
A 1 mm ×1 mm CGM System on Die Achieving 1.65-nA/mM In Vivo Resolution and 0–40-mM/L Detection Range With ΔΣ Backscatter Technique
Diabetes has become a leading cause of death and disability all over the world. Continuous glucose monitoring (CGM) based on wireless power transfer (WPT) and backscatter communication enables wireless real-time telemetry to control glycemic levels in a long term. However, conventional backscatter techniques in CGM systems converted the sensing current into a bit stream or a frequency signal to switch the antenna, leading to two drawbacks: 1) Large power-harvesting antennas are required to complement the power loss in data converting and antenna switching and 2) Both the resolution and detection range are limited even with a high-performance glucose sensor. In this work, we propose a$\Delta \Sigma $ backscatter technique to demonstrate a system on die (SoD) within a$1\times1$ -mm on-chip antenna. Implemented in the 65-nm CMOS process, the proposed SoD achieves a telemetry error less than 0.25% with little impact on WPT, as well as a wide detection range of 0–40 mM/L. In vivo experimental results show that the CGM SoD realizes a resolution of 1.65 nA/mM.- 29 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (1) , 54-66
Neural Dielet: A 0.4 mm$^{3}$ Battery-Less Crystal-Less Neural-Recording System on Die Achieving 1.6 cm Backscatter Range With 2 mm ×2 mm On-Chip Antenna
Miniaturization is essential in the design of wireless neural-recording systems. In recent years, the battery in neural-recording systems can be eliminated by wireless power transfer (WPT), while antenna and crystal become two main bottlenecks to minimize a battery-less neural implant. In conventional battery-less designs, the miniaturization of antenna led to a short communication range, and a crystal-less clock suffered from noise issue or power-hungry circuits. In this work, we demonstrate a 0.4mm $^{3}$ neural dielet, which is a battery-less crystal-less neural-recording system on die (SoD) within a 2mm×2mm on-chip coil antenna. The communication range through the ultra-small antenna is extended by a proposed dither-based 3 $^{rd}$ -order intermodulation (IM3) technique, which prevents the backscatter communication from WPT blocker. Meanwhile, a dither-based 2 $^{nd}$ -order intermodulation (IM2) wireless-lock technique is proposed to remove the crystal. Measured results show that the SoD consumes 53.2 $\mu$ W power and achieves a wireless communication range of 1.6cm at a bit-error rate (BER) of 8 $\times 10^{-6}$ , accompanied by simultaneous WPT for battery-less operation. In the animal experiment, the neural signal wirelessly recorded by our SoD in a battery-less way matches favorably with the wire-test results obtained by a commercial chip.
- 29 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (1) , 54-66
Neural Dielet: A 0.4 mm$^{3}$ Battery-Less Crystal-Less Neural-Recording System on Die Achieving 1.6 cm Backscatter Range With 2 mm ×2 mm On-Chip Antenna
Miniaturization is essential in the design of wireless neural-recording systems. In recent years, the battery in neural-recording systems can be eliminated by wireless power transfer (WPT), while antenna and crystal become two main bottlenecks to minimize a battery-less neural implant. In conventional battery-less designs, the miniaturization of antenna led to a short communication range, and a crystal-less clock suffered from noise issue or power-hungry circuits. In this work, we demonstrate a 0.4mm $^{3}$ neural dielet, which is a battery-less crystal-less neural-recording system on die (SoD) within a 2mm×2mm on-chip coil antenna. The communication range through the ultra-small antenna is extended by a proposed dither-based 3 $^{rd}$ -order intermodulation (IM3) technique, which prevents the backscatter communication from WPT blocker. Meanwhile, a dither-based 2 $^{nd}$ -order intermodulation (IM2) wireless-lock technique is proposed to remove the crystal. Measured results show that the SoD consumes 53.2 $\mu$ W power and achieves a wireless communication range of 1.6cm at a bit-error rate (BER) of 8 $\times 10^{-6}$ , accompanied by simultaneous WPT for battery-less operation. In the animal experiment, the neural signal wirelessly recorded by our SoD in a battery-less way matches favorably with the wire-test results obtained by a commercial chip.
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (1) , 105-115
A Wireless Headstage System Based on Neural-Recording Chip Featuring 315 nW Kickback-Reduction SAR ADC
Wireless neural-recording instruments eliminate the bulky cables in multi-channel signal transmission, while the system size should be reduced to mitigate the impact on freely-moving animals. As the battery usually dominates the system size, the neural-recording chip should be low power to minimize the battery in long-termly monitoring. In general, a neural-recording chip consists of an analog front end (AFE) and an 8bit $-$ 10bit analog-to-digital converter (ADC), while it's challenging to design an ADC with an 8 $-$ 10 effective number of bits (ENOB) and sub- $\mu$ W power consumption due to the kickback noise. In this work, we propose a kickback-reduction technique for a successive-approximation-register (SAR) ADC based on neural-recording chip. Fabricated in 65nm CMOS process, the proposed technique reduce the ADC power to 315nW, resulting in an 8-channel neural-recording chip with 249 $\mu$ W in total. Measured results show that the chip achieves an ADC ENOB of 9.73 bits, as well as an AFE gain of 43.3dB and input-referred noise (IRN) of 9.68 $\mu V_{rms}$ in a bandwidth of 0.9Hz $-$ 7.2kHz. Combined with a BLE chip and a PCB antenna, the chip is implemented into a 2.6g wireless headstage system (w/o battery), and an in-vivo demonstration is conducted on a male Sprague-Dawley rat with Parkinson's disease. The headstage system transfers the in-vivo neural signals to a commodity smartphone through BLE, and the miniature size induces little impact on freely-moving activities.
- 24 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (1) , 105-115
A Wireless Headstage System Based on Neural-Recording Chip Featuring 315 nW Kickback-Reduction SAR ADC
Wireless neural-recording instruments eliminate the bulky cables in multi-channel signal transmission, while the system size should be reduced to mitigate the impact on freely-moving animals. As the battery usually dominates the system size, the neural-recording chip should be low power to minimize the battery in long-termly monitoring. In general, a neural-recording chip consists of an analog front end (AFE) and an 8bit $-$ 10bit analog-to-digital converter (ADC), while it's challenging to design an ADC with an 8 $-$ 10 effective number of bits (ENOB) and sub- $\mu$ W power consumption due to the kickback noise. In this work, we propose a kickback-reduction technique for a successive-approximation-register (SAR) ADC based on neural-recording chip. Fabricated in 65nm CMOS process, the proposed technique reduce the ADC power to 315nW, resulting in an 8-channel neural-recording chip with 249 $\mu$ W in total. Measured results show that the chip achieves an ADC ENOB of 9.73 bits, as well as an AFE gain of 43.3dB and input-referred noise (IRN) of 9.68 $\mu V_{rms}$ in a bandwidth of 0.9Hz $-$ 7.2kHz. Combined with a BLE chip and a PCB antenna, the chip is implemented into a 2.6g wireless headstage system (w/o battery), and an in-vivo demonstration is conducted on a male Sprague-Dawley rat with Parkinson's disease. The headstage system transfers the in-vivo neural signals to a commodity smartphone through BLE, and the miniature size induces little impact on freely-moving activities.