Konstantin Nikolaus Beitl
Konstantin Nikolaus Beitl has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Erik Reimhult
Institute of Colloid and Biointerface Science, BOKU University, Vienna, Austria
3 shared publications - Guruprakash Subbiahdoss
Institute of Colloid and Biointerface Science, BOKU University, Muthgasse 11, Vienna A-1190, Austria
1 shared publication - Mudassar Mumtaz Virk
Institute of Biologically Inspired Materials, Department of Bionanosciences, BOKU-University of Natural Resources and Life Sciences, Vienna, Muthgasse 11, Stg.1, Stk.2, Vienna 1190, Austria
1 shared publication - Peter D. J. van Oostrum
Institute of Colloid and Biointerface Science (ICBS), Department of Bionanosciences (DBNS), BOKU University
1 shared publication Sandra Pérez-Jiménez
Institute of Colloid and Biointerface Science, Institute of Colloid and Biointerface Science
1 shared publication
Latest Publications
- Open Access
- 26 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (36) , 50432-50442
Alternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating
Implant-associated infections caused by bacterial biofilms remain a major clinical challenge, with high morbidity, often necessitating prolonged antibiotic therapy or implant revision surgery. To address the need for noninvasive alternatives, we investigated the use of alternating magnetic fields (AMFs) as a localized treatment modality for eradicating Staphylococcus aureus biofilms on titanium implant model surfaces. We demonstrate that AMF exposure effectively removes biofilms and kills bacteria at moderately elevated temperatures on the implant. Importantly, our results demonstrate that the antimicrobial efficacy of AMF treatment is primarily not due to heating. AMF vastly outperforms pure heating to the same temperatures for biofilm removal, despite inductive heating being the generally proposed mechanism for AMF antimicrobial action. Based on complementary imaging methods, we provide evidence that mechanical disruption, not a pure thermal effect, potentially driven by cavitation phenomena induced by transient, localized high temperature gradients, removes bacterial biofilms from titanium surfaces during AMF exposure. However, this mechanism also compromises the integrity of adjacent mammalian cells; confluent layers of SaOS-2 osteoblast-like cells exhibited actin cytoskeleton disintegration, membrane perforation, and a loss of viability even after brief AMF exposures. Our findings highlight a dual effect of AMF treatment: efficient biofilm removal is accompanied by collateral cytotoxicity, which requires further mechanistic research for clinically safe and effective AMF-based infection management strategies.
- 26 August 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (36) , 50432-50442
Open AccessAlternating Magnetic Fields Remove Biofilms but Damage Cells on Implant Models Also with Negligible Bulk Heating
Implant-associated infections caused by bacterial biofilms remain a major clinical challenge, with high morbidity, often necessitating prolonged antibiotic therapy or implant revision surgery. To address the need for noninvasive alternatives, we investigated the use of alternating magnetic fields (AMFs) as a localized treatment modality for eradicating Staphylococcus aureus biofilms on titanium implant model surfaces. We demonstrate that AMF exposure effectively removes biofilms and kills bacteria at moderately elevated temperatures on the implant. Importantly, our results demonstrate that the antimicrobial efficacy of AMF treatment is primarily not due to heating. AMF vastly outperforms pure heating to the same temperatures for biofilm removal, despite inductive heating being the generally proposed mechanism for AMF antimicrobial action. Based on complementary imaging methods, we provide evidence that mechanical disruption, not a pure thermal effect, potentially driven by cavitation phenomena induced by transient, localized high temperature gradients, removes bacterial biofilms from titanium surfaces during AMF exposure. However, this mechanism also compromises the integrity of adjacent mammalian cells; confluent layers of SaOS-2 osteoblast-like cells exhibited actin cytoskeleton disintegration, membrane perforation, and a loss of viability even after brief AMF exposures. Our findings highlight a dual effect of AMF treatment: efficient biofilm removal is accompanied by collateral cytotoxicity, which requires further mechanistic research for clinically safe and effective AMF-based infection management strategies.
- Open Access
- 15 July 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (14) , 7734
Effect of Solvent Properties on the Critical Solution Temperature of Thermoresponsive Polymers
The ability of thermoresponsive polymers to respond to temperature with a reversible conformational change makes them promising ‘smart’ materials for solutions in medical and biotechnological applications. In this work, two such polymers and structural isomers were studied: poly(N-isopropyl acrylamide) (PNiPAm) and poly(2-isopropyl-2-oxazoline) (PiPOx). We compare the critical solution temperatures (CST) of these polymers in D2O and H2O in the presence of Hofmeister series salts, as results obtained under these different solvent conditions are often compared. D2O has a higher dipole moment and electronegativity than H2O, which could significantly alter the CST transition. We used two complementary methods to measure the CST, dynamic light scattering (DLS) and differential scanning calorimetry (DSC) and found that the CST decreased significantly in D2O compared to H2O. In the presence of highly concentrated kosmotropes, the CST of both polymers decreased in both solvents. The influence of the kosmotropic anions was smaller than the water isotope effect at low ionic strengths but considerably higher at physiological ionic strengths. However, the Hofmeister anion effect was quantitatively different in H2O than in D2O, with the largest relative differences observed for Cl−, where the CSTs in D2O decreased more than in H2O measured by DLS but less by DSC. PiPOx was more sensitive than PNiPAm to the presence of chaotropes. It exhibited much higher transition enthalpies and multistep transitions, especially in aqueous solutions. Our results highlight that measurements of thermoresponsive polymer properties in D2O cannot be compared directly or quantitatively to application conditions or even measurements performed in H2O.
- 15 July 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (14) , 7734
Open AccessEffect of Solvent Properties on the Critical Solution Temperature of Thermoresponsive Polymers
The ability of thermoresponsive polymers to respond to temperature with a reversible conformational change makes them promising ‘smart’ materials for solutions in medical and biotechnological applications. In this work, two such polymers and structural isomers were studied: poly(N-isopropyl acrylamide) (PNiPAm) and poly(2-isopropyl-2-oxazoline) (PiPOx). We compare the critical solution temperatures (CST) of these polymers in D2O and H2O in the presence of Hofmeister series salts, as results obtained under these different solvent conditions are often compared. D2O has a higher dipole moment and electronegativity than H2O, which could significantly alter the CST transition. We used two complementary methods to measure the CST, dynamic light scattering (DLS) and differential scanning calorimetry (DSC) and found that the CST decreased significantly in D2O compared to H2O. In the presence of highly concentrated kosmotropes, the CST of both polymers decreased in both solvents. The influence of the kosmotropic anions was smaller than the water isotope effect at low ionic strengths but considerably higher at physiological ionic strengths. However, the Hofmeister anion effect was quantitatively different in H2O than in D2O, with the largest relative differences observed for Cl−, where the CSTs in D2O decreased more than in H2O measured by DLS but less by DSC. PiPOx was more sensitive than PNiPAm to the presence of chaotropes. It exhibited much higher transition enthalpies and multistep transitions, especially in aqueous solutions. Our results highlight that measurements of thermoresponsive polymer properties in D2O cannot be compared directly or quantitatively to application conditions or even measurements performed in H2O.
- Open Access
- 9 May 2024
- Published by MDPI AG in Preprints.org
Effect of Solvent Properties on the Critical Solution Temperature of Thermoresponsive Polymers
The ability of thermoresponsive polymers to respond to temperature with a reversible conformational change makes them promising ‘smart’ materials for solutions in medical and biotechnological applications. In this work, two such polymers and structural isomers were studied: poly(N-isopropyl acrylamide) (PNiPAm) and poly(2-isopropyl-2-oxazoline) (PiPOx). We compare the critical solution temperatures (CST) of these polymers in D2O and H2O in the presence of Hofmeister series salts, as results obtained under these different solvent conditions are often compared. D2O has a higher dipole moment and electronegativity than H2O, which could significantly alter the CST transition. We used two complementary methods to measure the CST, dynamic light scattering (DLS) and differential scanning calorimetry (DSC), and found that the CST decreased significantly in D2O compared to H2O. In the presence of highly concentrated kosmotropes, the CST of both polymers decreased in both solvents. The influence of the kosmotropic anions was smaller than the water isotope effect at low ionic strengths but considerably higher at physiological ionic strengths. However, the Hofmeister anion effect was quantitatively different in H2O than in D2O, with the largest relative differences observed for Cl-, where the CSTs in D2O decreased more than in H2O measured by DLS but less by DSC. PiPOx was more sensitive than PNiPAm to the presence of chaotropes. It exhibited much higher transition enthalpies and multistep transitions, especially in aqueous solutions. Our results highlight that measurements of thermoresponsive polymer properties in D2O cannot be compared directly or quantitatively to application conditions or even measurements performed in H2O.
- 9 May 2024
- Published by MDPI AG in Preprints.org
Open AccessEffect of Solvent Properties on the Critical Solution Temperature of Thermoresponsive Polymers
The ability of thermoresponsive polymers to respond to temperature with a reversible conformational change makes them promising ‘smart’ materials for solutions in medical and biotechnological applications. In this work, two such polymers and structural isomers were studied: poly(N-isopropyl acrylamide) (PNiPAm) and poly(2-isopropyl-2-oxazoline) (PiPOx). We compare the critical solution temperatures (CST) of these polymers in D2O and H2O in the presence of Hofmeister series salts, as results obtained under these different solvent conditions are often compared. D2O has a higher dipole moment and electronegativity than H2O, which could significantly alter the CST transition. We used two complementary methods to measure the CST, dynamic light scattering (DLS) and differential scanning calorimetry (DSC), and found that the CST decreased significantly in D2O compared to H2O. In the presence of highly concentrated kosmotropes, the CST of both polymers decreased in both solvents. The influence of the kosmotropic anions was smaller than the water isotope effect at low ionic strengths but considerably higher at physiological ionic strengths. However, the Hofmeister anion effect was quantitatively different in H2O than in D2O, with the largest relative differences observed for Cl-, where the CSTs in D2O decreased more than in H2O measured by DLS but less by DSC. PiPOx was more sensitive than PNiPAm to the presence of chaotropes. It exhibited much higher transition enthalpies and multistep transitions, especially in aqueous solutions. Our results highlight that measurements of thermoresponsive polymer properties in D2O cannot be compared directly or quantitatively to application conditions or even measurements performed in H2O.
- 6 March 2023
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 35 (17) , 174003
Synthesis of patchy particles using gaseous ligands
The collective self-assembly of colloidal particles can be influenced by the composition of the suspending medium, the bulk material of the particles themselves and, importantly, by their surface chemistry. This can be inhomogeneous or patchy to give an orientational dependence to the interaction potential between the particles. These additional constraints to the energy landscape then steer the self-assembly towards configurations of fundamental or applicational interest. We present a novel approach to modify the surface chemistry of colloidal particles to give them two polar patches, using gaseous ligands. In particular, we synthesize polar inverse patchy colloids, i.e., charged particles with two (fluorescent) patches of the opposite charge on their poles. We characterize the dependence of these charges on the pH of the suspending solution.
- 6 March 2023
- Published by IOP Publishing in Journal of Physics: Condensed Matter
- Vol. 35 (17) , 174003
Synthesis of patchy particles using gaseous ligands
The collective self-assembly of colloidal particles can be influenced by the composition of the suspending medium, the bulk material of the particles themselves and, importantly, by their surface chemistry. This can be inhomogeneous or patchy to give an orientational dependence to the interaction potential between the particles. These additional constraints to the energy landscape then steer the self-assembly towards configurations of fundamental or applicational interest. We present a novel approach to modify the surface chemistry of colloidal particles to give them two polar patches, using gaseous ligands. In particular, we synthesize polar inverse patchy colloids, i.e., charged particles with two (fluorescent) patches of the opposite charge on their poles. We characterize the dependence of these charges on the pH of the suspending solution.