Ahlem Ghabi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahlem Ghabi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Toufik Boushaki
ICARE-CNRS & University of Orléans , 1C Avenue de la Recherche Scientifique
4 shared publications Eric Robert
2 shared publicationsPablo Escot Bocanegra
2 shared publicationsA. Hidouri
Research Lab of Technology Energy and innovative Materials, Faculty of Sciences of Gafsa, University of Gafsa, Gafsa, Tunisia
1 shared publication- Brahim Sarh
ICARE-CNRS, 1C Avenue de la recherche scientifique
1 shared publication - Eric Robert
UMR 7344 GREMI, CNRS/Université d'Orléans 5 , Orléans
1 shared publication
Latest Publications
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Etude des flammes non-prémélangées de biogaz assistées par plasma
Le biogaz, essentiellement composé de méthane (CH₄) et de dioxyde de carbone (CO₂), est considéré comme une ressource prometteuse dans le domaine des énergies renouvelables grâce à sa production issue de la décomposition des matières organiques (biomasse, déchets…). Cependant, la présence de taux élevés de CO₂ dans le mélange de biogaz peut entraîner lors de sa combustion des instabilités menant parfois à l'extinction de la flamme, ce qui engendre des risques pour les systèmes énergétiques et limite l'efficacité énergétique globale. L'utilisation de décharges plasmas pour l'assistance et le contrôle de la combustion produit des effets bénéfiques sur la stabilité de la flamme et sur les caractéristiques de combustion. Cette étude a pour but d'évaluer l'impact d'un plasma impulsionnel pour améliorer la stabilité et contrôler les émissions polluantes de la combustion de biogaz. Des investigations sont menées pour caractériser les interactions entre les décharges impulsionnelles et les flammes, en fonction de paramètres liés à la combustion (taux de CO₂ dans le combustible, richesse globale, nombre de swirl) et d'autres liés au plasma (fréquence de répétition des impulsions, amplitude de la tension électrique appliquée aux électrodes du réacteur plasma) pour comprendre leurs influences sur les caractéristiques de la flamme. Trois configurations de système plasma (Arc glissant, Pointe-Tige-Pointe et Tige-Anneau) avec deux types de brûleurs (injection radiale et injection axiale du combustible) ont été étudiées. Différentes techniques et diagnostics optiques ont été mis en œuvre pour mener cette étude : La chimiluminescence sur OH* pour analyser la stabilité et la structure de la flamme ; la spectroscopie d'émission optique pour visualiser et déterminer les espèces créées par le plasma et la flamme ; la Vélocimétrie par Imagerie de Particules (PIV) pour l'étude dynamique de l'écoulement réactif ; l'analyse des gaz brûlés pour la caractérisation des émissions polluantes (NOₓ, CO). Les résultats obtenus ont permis de mettre en évidence les effets de l'utilisation des plasmas impulsionnels microsecondes sur la stabilité de la flamme, les émissions polluantes, les espèces impliquées au niveau du plasma ou/et de la flamme et le champ de vitesse de l'écoulement réactif.
- 8 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Etude des flammes non-prémélangées de biogaz assistées par plasma
Le biogaz, essentiellement composé de méthane (CH₄) et de dioxyde de carbone (CO₂), est considéré comme une ressource prometteuse dans le domaine des énergies renouvelables grâce à sa production issue de la décomposition des matières organiques (biomasse, déchets…). Cependant, la présence de taux élevés de CO₂ dans le mélange de biogaz peut entraîner lors de sa combustion des instabilités menant parfois à l'extinction de la flamme, ce qui engendre des risques pour les systèmes énergétiques et limite l'efficacité énergétique globale. L'utilisation de décharges plasmas pour l'assistance et le contrôle de la combustion produit des effets bénéfiques sur la stabilité de la flamme et sur les caractéristiques de combustion. Cette étude a pour but d'évaluer l'impact d'un plasma impulsionnel pour améliorer la stabilité et contrôler les émissions polluantes de la combustion de biogaz. Des investigations sont menées pour caractériser les interactions entre les décharges impulsionnelles et les flammes, en fonction de paramètres liés à la combustion (taux de CO₂ dans le combustible, richesse globale, nombre de swirl) et d'autres liés au plasma (fréquence de répétition des impulsions, amplitude de la tension électrique appliquée aux électrodes du réacteur plasma) pour comprendre leurs influences sur les caractéristiques de la flamme. Trois configurations de système plasma (Arc glissant, Pointe-Tige-Pointe et Tige-Anneau) avec deux types de brûleurs (injection radiale et injection axiale du combustible) ont été étudiées. Différentes techniques et diagnostics optiques ont été mis en œuvre pour mener cette étude : La chimiluminescence sur OH* pour analyser la stabilité et la structure de la flamme ; la spectroscopie d'émission optique pour visualiser et déterminer les espèces créées par le plasma et la flamme ; la Vélocimétrie par Imagerie de Particules (PIV) pour l'étude dynamique de l'écoulement réactif ; l'analyse des gaz brûlés pour la caractérisation des émissions polluantes (NOₓ, CO). Les résultats obtenus ont permis de mettre en évidence les effets de l'utilisation des plasmas impulsionnels microsecondes sur la stabilité de la flamme, les émissions polluantes, les espèces impliquées au niveau du plasma ou/et de la flamme et le champ de vitesse de l'écoulement réactif.
- 4 January 2024
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 146 (6) , 1-12
Experimental Investigation on Microsecond Pulsed Plasma Supported Biogas Combustion
This paper evaluates the effect of a microsecond pulsed plasma (MPP) on the stabilization and emission characteristics of non-premixed biogas/air flames with various CO2 contents. The MPP is generated by a unique DC-pulsed power generator providing high voltage (HV) pulses over a wide range of pulse repetition frequencies (PRFs). The burner configuration is made up of two concentric tubes in which a swirler is placed inside the annular part, ensuring the oxidizer's rotation. The central tube delivers the fuel through an injector placed close to the burner exit. Electrical diagnostics, including voltage, were performed. OH* chemiluminescence measurements were done to describe the structure and stability of the flame. Results showed that plasma generated by microsecond HV pulses can improve flame stability. In this regard, the distribution of key active species in the burner was studied via optical emission spectroscopy (OES). The results revealed that the pulsed plasma generates chemically active species such as excited N2*, CH*, OH* molecules, and H* and O* atoms, thereby improving flame stability. The dependence of the emitted species intensities on plasma parameters was investigated in detail. It is demonstrated that MPP can drastically enhance the dynamic flame stability of swirling non-premixed biogas flames, especially at lean operating conditions. In addition, NOx and CO emissions were studied over a wide range of pulse repetition frequencies. It is seen that the pulsed plasma increases NOx emission slightly and significantly reduces CO concentration in the flue gases.
- 4 January 2024
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 146 (6) , 1-12
Experimental Investigation on Microsecond Pulsed Plasma Supported Biogas Combustion
This paper evaluates the effect of a microsecond pulsed plasma (MPP) on the stabilization and emission characteristics of non-premixed biogas/air flames with various CO2 contents. The MPP is generated by a unique DC-pulsed power generator providing high voltage (HV) pulses over a wide range of pulse repetition frequencies (PRFs). The burner configuration is made up of two concentric tubes in which a swirler is placed inside the annular part, ensuring the oxidizer's rotation. The central tube delivers the fuel through an injector placed close to the burner exit. Electrical diagnostics, including voltage, were performed. OH* chemiluminescence measurements were done to describe the structure and stability of the flame. Results showed that plasma generated by microsecond HV pulses can improve flame stability. In this regard, the distribution of key active species in the burner was studied via optical emission spectroscopy (OES). The results revealed that the pulsed plasma generates chemically active species such as excited N2*, CH*, OH* molecules, and H* and O* atoms, thereby improving flame stability. The dependence of the emitted species intensities on plasma parameters was investigated in detail. It is demonstrated that MPP can drastically enhance the dynamic flame stability of swirling non-premixed biogas flames, especially at lean operating conditions. In addition, NOx and CO emissions were studied over a wide range of pulse repetition frequencies. It is seen that the pulsed plasma increases NOx emission slightly and significantly reduces CO concentration in the flue gases.
- 26 February 2023
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 195 (7) , 1461-1482
Numerical Study of Turbulent Swirling Diffusion Flame Under Lean and Rich Conditions Using Turbulence Realizable k-epsilon Model
This work investigates numerically a non-premixed swirling flame in a coaxial burner with a radial fuel injection under lean and rich conditions of mixtures. The swirler is placed in the annular part of the burner. The fuel is injected radially through eight holes symmetrically distributed on the periphery of the central tube. All simulations are carried out using the ANSYS-Fluent CFD code. The turbulence is captured using the Reynolds Averaged Navier-Stokes approach. Chemistry/turbulence interaction is resolved using the Eddy Dissipation Model. Simulations are performed with a global equivalence ratio ranging from 0.5 to 1.3. Model validation is achieved by comparing computed results to our experimental data of Stereoscopic Particle Image Velocimetry obtained in the case of the stoichiometric regime. Good agreement between numerical results and experimental measurements is assigned. The central recirculation zone and the swirling jet region due to the presence of the swirl are well predicted by the simulations. The effect of the global equivalence ratio on the profile of axial velocity, temperature distributions and pollutant emissions (CO and NOx) is numerically studied. From dynamic point of view, the equivalence ratio modifies the mean axial velocity of the swirling diffusion flame. The increase of equivalence ratio destabilizes the flame by increasing the liftoff height. NO production decreases by the increasing of the equivalence ratio.
- 26 February 2023
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 195 (7) , 1461-1482
Numerical Study of Turbulent Swirling Diffusion Flame Under Lean and Rich Conditions Using Turbulence Realizable k-epsilon Model
This work investigates numerically a non-premixed swirling flame in a coaxial burner with a radial fuel injection under lean and rich conditions of mixtures. The swirler is placed in the annular part of the burner. The fuel is injected radially through eight holes symmetrically distributed on the periphery of the central tube. All simulations are carried out using the ANSYS-Fluent CFD code. The turbulence is captured using the Reynolds Averaged Navier-Stokes approach. Chemistry/turbulence interaction is resolved using the Eddy Dissipation Model. Simulations are performed with a global equivalence ratio ranging from 0.5 to 1.3. Model validation is achieved by comparing computed results to our experimental data of Stereoscopic Particle Image Velocimetry obtained in the case of the stoichiometric regime. Good agreement between numerical results and experimental measurements is assigned. The central recirculation zone and the swirling jet region due to the presence of the swirl are well predicted by the simulations. The effect of the global equivalence ratio on the profile of axial velocity, temperature distributions and pollutant emissions (CO and NOx) is numerically studied. From dynamic point of view, the equivalence ratio modifies the mean axial velocity of the swirling diffusion flame. The increase of equivalence ratio destabilizes the flame by increasing the liftoff height. NO production decreases by the increasing of the equivalence ratio.
- 22 February 2023
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 195 (7) , 1599-1621
Laminar Burning Velocity, Adiabatic Flame Temperature, and Pollutants of Biogas/Air Mixture at Various CO2 Concentrations and Plasma Assist
Mixtures of CH4 and CO2, known as biogas, are considered as renewable gas with low heat energy, which makes it extremely difficult to use as fuel in conventional natural gas equipment. To better understand the behavior of biogas mixtures and their properties, numerical results of the impact of carbon dioxide on laminar burning velocity and flame temperature of methane (CH4)–carbon dioxide (CO2)–air combustion were done. One of the most promising methods to enhance combustion is the use of a plasma source to assist unstable flames. For this purpose, experimental results to investigate the effect of microsecond pulsed plasma on non-premixed biogas flames were conducted. In the first section, laminar burning velocities and adiabatic flame temperature have been numerically calculated by one-dimensional steady code using several chemical kinetic mechanisms. Numerical results were compared with several experimental results from the literature. The laminar burning velocity and the adiabatic temperature of biogas/air combustion were calculated with CO2 concentration ranging from 0% to 50% in the mixture. The equivalence ratio was varied from 0.4 to 1.4, the initial pressure was set at 1 bar, and the temperature was set to 300 K. The impact of CO2 addition on the CO and NOx emissions at equivalence ratios from lean to rich (0.4–1.4) was investigated. It was found that increasing CO2 in the biogas lowers NOx and increases CO. In the second section, the effects of microsecond pulsed plasma on non-premixed swirling biogas/air flames were experimentally investigated. The plasma-assisted combustion was carried out in a coaxial burner. It consists of two concentric tubes; the central tube delivers the biogas flow to the injector and the annular tube contains a swirler and supplies the airflow. To create plasma in the stabilization zone of the flame, a rod-ring microsecond plasma configuration was used. OH* chemiluminescence measurements are used to describe the structure and stability of the flame. Results showed that plasma generated by microsecond high-voltage (HV) pulses can improve flame stability. An analysis of the optical emission spectra (OES) showed that plasma generates chemically active species such as excited N2*, CH*, OH* molecules, and H* atoms, leading to improved flame stability. The dependence of their intensities on both the pulse repetition frequency (PRF) and the input electrical voltage was investigated. The gas analysis of the exhaust gas was carried out with and without plasma. The exhaust gas concentration measurements revealed that the rod-ring pulsed plasma reduces CO with a low impact on the NOx level.
- 22 February 2023
- Published by Taylor & Francis in Combustion Science and Technology
- Vol. 195 (7) , 1599-1621
Laminar Burning Velocity, Adiabatic Flame Temperature, and Pollutants of Biogas/Air Mixture at Various CO2 Concentrations and Plasma Assist
Mixtures of CH4 and CO2, known as biogas, are considered as renewable gas with low heat energy, which makes it extremely difficult to use as fuel in conventional natural gas equipment. To better understand the behavior of biogas mixtures and their properties, numerical results of the impact of carbon dioxide on laminar burning velocity and flame temperature of methane (CH4)–carbon dioxide (CO2)–air combustion were done. One of the most promising methods to enhance combustion is the use of a plasma source to assist unstable flames. For this purpose, experimental results to investigate the effect of microsecond pulsed plasma on non-premixed biogas flames were conducted. In the first section, laminar burning velocities and adiabatic flame temperature have been numerically calculated by one-dimensional steady code using several chemical kinetic mechanisms. Numerical results were compared with several experimental results from the literature. The laminar burning velocity and the adiabatic temperature of biogas/air combustion were calculated with CO2 concentration ranging from 0% to 50% in the mixture. The equivalence ratio was varied from 0.4 to 1.4, the initial pressure was set at 1 bar, and the temperature was set to 300 K. The impact of CO2 addition on the CO and NOx emissions at equivalence ratios from lean to rich (0.4–1.4) was investigated. It was found that increasing CO2 in the biogas lowers NOx and increases CO. In the second section, the effects of microsecond pulsed plasma on non-premixed swirling biogas/air flames were experimentally investigated. The plasma-assisted combustion was carried out in a coaxial burner. It consists of two concentric tubes; the central tube delivers the biogas flow to the injector and the annular tube contains a swirler and supplies the airflow. To create plasma in the stabilization zone of the flame, a rod-ring microsecond plasma configuration was used. OH* chemiluminescence measurements are used to describe the structure and stability of the flame. Results showed that plasma generated by microsecond high-voltage (HV) pulses can improve flame stability. An analysis of the optical emission spectra (OES) showed that plasma generates chemically active species such as excited N2*, CH*, OH* molecules, and H* atoms, leading to improved flame stability. The dependence of their intensities on both the pulse repetition frequency (PRF) and the input electrical voltage was investigated. The gas analysis of the exhaust gas was carried out with and without plasma. The exhaust gas concentration measurements revealed that the rod-ring pulsed plasma reduces CO with a low impact on the NOx level.