Abdullah Faisal Al-Battal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Abdullah Faisal Al-Battal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Truong Q. Nguyen
Department of Electrical and Computer Engineering, University of California at San Diego, San Diego, CA, USA
3 shared publications - Ammar Alsheghri
Mechanical Engineering Department, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran 31261, Saudi Arabia
1 shared publication - Cheolhong An
Electrical and Computer Engineering Department, UC San Diego, La Jolla, CA, USA
1 shared publication Chien Phan
Diagnostic Imaging Department, University Medical Center at Ho Chi Minh City, Viet Nam
1 shared publication- Dacheng Tao
Nanyang Technological University
1 shared publication - Hadeel Saad Alghamdi
King Fahd University of Petroleum and Minerals
1 shared publication
Latest Publications
- 24 October 2026
- Published by Springer Nature
- p. 178-192
Systematic Evaluation of Data Augmentation Strategies for Ordinal BI-RADS Classification in Breast Ultrasound: A Benchmark on BUS-BRA
- 24 October 2026
- Published by Springer Nature
- p. 178-192
Systematic Evaluation of Data Augmentation Strategies for Ordinal BI-RADS Classification in Breast Ultrasound: A Benchmark on BUS-BRA
- 31 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 186, 109602
Enhancing lesion detection in liver and kidney CT scans via lesion mask selection from two models: A main model and a model focused on small lesions
- 31 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 186, 109602
Enhancing lesion detection in liver and kidney CT scans via lesion mask selection from two models: A main model and a model focused on small lesions
- Open Access
Localizing Scan Targets from Human Pose for Autonomous Lung Ultrasound Imaging
Ultrasound is progressing toward becoming an affordable and versatile solution to medical imaging. With the advent of COVID-19 global pandemic, there is a need to fully automate ultrasound imaging as it requires trained operators in close proximity to patients for a long period of time, therefore increasing risk of infection. In this work, we investigate the important yet seldom-studied problem of scan target localization, under the setting of lung ultrasound imaging. We propose a purely vision-based, data driven method that incorporates learning-based computer vision techniques. We combine a human pose estimation model with a specially designed regression model to predict the lung ultrasound scan targets, and deploy multiview stereo vision to enhance the consistency of 3D target localization. While related works mostly focus on phantom experiments, we collect data from 30 human subjects for testing. Our method attains an accuracy level of 16.00(9.79) mm for probe positioning and 4.44(3.75) degree for probe orientation, with a success rate above 80% under an error threshold of 25mm for all scan targets. Moreover, our approach can serve as a general solution to other types of ultrasound modalities. The code for implementation has been released.
Open AccessLocalizing Scan Targets from Human Pose for Autonomous Lung Ultrasound Imaging
Ultrasound is progressing toward becoming an affordable and versatile solution to medical imaging. With the advent of COVID-19 global pandemic, there is a need to fully automate ultrasound imaging as it requires trained operators in close proximity to patients for a long period of time, therefore increasing risk of infection. In this work, we investigate the important yet seldom-studied problem of scan target localization, under the setting of lung ultrasound imaging. We propose a purely vision-based, data driven method that incorporates learning-based computer vision techniques. We combine a human pose estimation model with a specially designed regression model to predict the lung ultrasound scan targets, and deploy multiview stereo vision to enhance the consistency of 3D target localization. While related works mostly focus on phantom experiments, we collect data from 30 human subjects for testing. Our method attains an accuracy level of 16.00(9.79) mm for probe positioning and 4.44(3.75) degree for probe orientation, with a success rate above 80% under an error threshold of 25mm for all scan targets. Moreover, our approach can serve as a general solution to other types of ultrasound modalities. The code for implementation has been released.
- 24 February 2023
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 107, 102205
Multi-path decoder U-Net: A weakly trained real-time segmentation network for object detection and localization in ultrasound scans
- 24 February 2023
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 107, 102205
Multi-path decoder U-Net: A weakly trained real-time segmentation network for object detection and localization in ultrasound scans
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 288-291
Data Augmentation Methods For Object Detection and Segmentation In Ultrasound Scans: An Empirical Comparative Study
In ultrasound imaging, sonographers are tasked with analyzing scans for diagnostic purposes; a challenging task, especially for novice sonographers. Deep Learning methods have shown great potential in their ability to infer semantics and key information from scans to assist with these tasks. However, deep learning methods require large training sets to accomplish tasks such as segmentation and object detection. Generating these large datasets is a significant challenge in the medical domain due to the high cost of acquisition and annotation. Therefore, data augmentation is used to increase the size of training datasets to create the needed variability for deep learning models to generalize. These augmentation methods try to mimic differences among scans that result from noise, tissue movement, acquisition settings, and others. In this paper, we analyze the effectiveness of general augmentation methods that perform color, rigid, and non-rigid geometric transformation, to empirically analyze and compare their ability to improve the performance of three segmentation architectures on three different ultrasound datasets. We observe that non-rigid geometric transformations produce the best performance improvement.
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 28, 288-291
Data Augmentation Methods For Object Detection and Segmentation In Ultrasound Scans: An Empirical Comparative Study
In ultrasound imaging, sonographers are tasked with analyzing scans for diagnostic purposes; a challenging task, especially for novice sonographers. Deep Learning methods have shown great potential in their ability to infer semantics and key information from scans to assist with these tasks. However, deep learning methods require large training sets to accomplish tasks such as segmentation and object detection. Generating these large datasets is a significant challenge in the medical domain due to the high cost of acquisition and annotation. Therefore, data augmentation is used to increase the size of training datasets to create the needed variability for deep learning models to generalize. These augmentation methods try to mimic differences among scans that result from noise, tissue movement, acquisition settings, and others. In this paper, we analyze the effectiveness of general augmentation methods that perform color, rigid, and non-rigid geometric transformation, to empirically analyze and compare their ability to improve the performance of three segmentation architectures on three different ultrasound datasets. We observe that non-rigid geometric transformations produce the best performance improvement.