Shuaicong Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuaicong Hu has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Cuiwei Yang
Department of Biomedical Engineering, College of Biomedical Engineering, Fudan University, Shanghai, China
12 shared publications - Jian Liu
Department of Biomedical Engineering, College of Biomedical Engineering, Fudan University, Shanghai, China
10 shared publications - Yanan Wang
Department of Biomedical Engineering, College of Biomedical Engineering, Fudan University, Shanghai, China
8 shared publications Aiguo Wang
Xinghua City Peoples Hospital, Jiangsu, China
2 shared publications- Daomiao Wang
Center for Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, 200433, PR China
2 shared publications Kuanzheng Li
Xinghua City Peoples Hospital, Jiangsu, China
2 shared publications
Latest Publications
- 11 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (7) , 6279-6291
ECG-AuxNet: A Dual-Branch Spatial-Temporal Feature Fusion Framework With Auxiliary Learning for Enhanced Cardiac Disease Diagnosis
Objective: Multiple limitations exist in current automated ECG analysis, including insufficient feature integration across leads, limited interpretability, poor generalization, and inadequate handling of class imbalance. To address these challenges, we develop a novel dual-branch framework that comprehensively captures spatial-temporal features for cardiac disease diagnosis. Methods: ECG-AuxNet combines a Multi-scale Transformer Attention CNN for spatial feature extraction and a GRU network for temporal dependency modeling. A Dual-stage Cross-Attention Fusion module integrates features from both branches, while a Feature Space Reconstruction (FSR) auxiliary task is introduced as a manifold regularizer to enhance feature discrimination. The framework was evaluated on PTB-XL (15,709 ECGs) and validated in real-world clinical scenarios (SXMU-2k, 1,673 ECGs). Results: For class-imbalanced disease recognition (NORM, CD, MI, STTC), ECG-AuxNet attained 78.34% F1-score on PTB-XL and 82.63% F1-score on SXMU-2k, outperforming 9 baseline models. FSR significantly improved feature discrimination by 11.7%, enhancing class boundary clarity and classification accuracy. Grad-CAM analysis revealed attention patterns that precisely match cardiologists' diagnostic focus areas. Conclusion: ECG-AuxNet effectively integrates spatial-temporal features through auxiliary learning, achieving robust generalizability in cardiac disease diagnosis with interpretability aligned with clinical expertise.
- 11 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (7) , 6279-6291
ECG-AuxNet: A Dual-Branch Spatial-Temporal Feature Fusion Framework With Auxiliary Learning for Enhanced Cardiac Disease Diagnosis
Objective: Multiple limitations exist in current automated ECG analysis, including insufficient feature integration across leads, limited interpretability, poor generalization, and inadequate handling of class imbalance. To address these challenges, we develop a novel dual-branch framework that comprehensively captures spatial-temporal features for cardiac disease diagnosis. Methods: ECG-AuxNet combines a Multi-scale Transformer Attention CNN for spatial feature extraction and a GRU network for temporal dependency modeling. A Dual-stage Cross-Attention Fusion module integrates features from both branches, while a Feature Space Reconstruction (FSR) auxiliary task is introduced as a manifold regularizer to enhance feature discrimination. The framework was evaluated on PTB-XL (15,709 ECGs) and validated in real-world clinical scenarios (SXMU-2k, 1,673 ECGs). Results: For class-imbalanced disease recognition (NORM, CD, MI, STTC), ECG-AuxNet attained 78.34% F1-score on PTB-XL and 82.63% F1-score on SXMU-2k, outperforming 9 baseline models. FSR significantly improved feature discrimination by 11.7%, enhancing class boundary clarity and classification accuracy. Grad-CAM analysis revealed attention patterns that precisely match cardiologists' diagnostic focus areas. Conclusion: ECG-AuxNet effectively integrates spatial-temporal features through auxiliary learning, achieving robust generalizability in cardiac disease diagnosis with interpretability aligned with clinical expertise.
- 19 December 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 166
An ultra-efficient edge-based wearable system for real-time and remote blood pressure monitoring
- 19 December 2025
- Published by Elsevier in Engineering Applications of Artificial Intelligence
- Vol. 166
An ultra-efficient edge-based wearable system for real-time and remote blood pressure monitoring
- 8 December 2025
- Published by Elsevier in Information Fusion
- Vol. 129
Bridging the gap between computer vision and bioelectrical signal analysis
- 8 December 2025
- Published by Elsevier in Information Fusion
- Vol. 129
Bridging the gap between computer vision and bioelectrical signal analysis
- Open Access
- 14 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 7548
Transparent artificial intelligence-enabled interpretable and interactive sleep apnea assessment across flexible monitoring scenarios
Early detection of widespread undiagnosed sleep apnea is crucial for preventing its severe health complications. However, large-scale diagnosis faces inaccessible monitoring and trust barriers in automated analysis, particularly due to the absence of transparent artificial intelligence frameworks capable of monitoring adaptation. Here, we develop Apnea Interact Xplainer, a transparent system enabling sleep apnea diagnosis through flexible channel analysis across clinical and home settings. Analyzing 15,807 polysomnography recordings from seven independent multi-ethnic cohorts, our system achieves accuracies of 0.738-0.810 for four-level severity classification, with 99.8% accuracy within one severity grade and R-squared of 0.92-0.96 for apnea-hypopnea index prediction on external test cohorts. The system provides multi-level expert-logic interpretable visualization of respiratory patterns enabling transparent collaborative decision-making. Notably, it achieves a sensitivity of 0.970 for early sleep apnea detection using only oximetry signals, while providing nightly risk assessment and intelligent monitoring reports. This study establishes a paradigm shift in advancing early and cost-effective sleep apnea diagnosis through transparent artificial intelligence.
- 14 August 2025
- Published by Springer Nature in Nature Communications
- Vol. 16 (1) , 7548
Open AccessTransparent artificial intelligence-enabled interpretable and interactive sleep apnea assessment across flexible monitoring scenarios
Early detection of widespread undiagnosed sleep apnea is crucial for preventing its severe health complications. However, large-scale diagnosis faces inaccessible monitoring and trust barriers in automated analysis, particularly due to the absence of transparent artificial intelligence frameworks capable of monitoring adaptation. Here, we develop Apnea Interact Xplainer, a transparent system enabling sleep apnea diagnosis through flexible channel analysis across clinical and home settings. Analyzing 15,807 polysomnography recordings from seven independent multi-ethnic cohorts, our system achieves accuracies of 0.738-0.810 for four-level severity classification, with 99.8% accuracy within one severity grade and R-squared of 0.92-0.96 for apnea-hypopnea index prediction on external test cohorts. The system provides multi-level expert-logic interpretable visualization of respiratory patterns enabling transparent collaborative decision-making. Notably, it achieves a sensitivity of 0.970 for early sleep apnea detection using only oximetry signals, while providing nightly risk assessment and intelligent monitoring reports. This study establishes a paradigm shift in advancing early and cost-effective sleep apnea diagnosis through transparent artificial intelligence.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (17) , 35875-35889
A Dual-Focus Cloud–Edge Collaborative Framework in Multitask Hemodynamic Parameter Cross-Scale Analysis: The Equilibrium of Clinical Performance and Efficiency
The precise monitoring of hemodynamic parameters is crucial for cardiovascular health assessment and disease prevention. However, current noninvasive hemodynamic monitoring technologies fail to balance performance and efficiency. To overcome these challenges, this study introduces a dual-focus multitask fusion framework built on a sparse multigate mixture-of-experts network (SM2oE) and multiview photoplethysmography (PPG) for the accurate estimation of noninvasive hemodynamic parameters. This framework integrates a multiscale fusion architecture with a hybrid attention mechanism and incorporates an uncertainty regression loss function (UR-Loss) to enhance intertask information fusion and overall model performance. Through structured pruning and bidirectional knowledge distillation, the framework effectively reduces computational costs and ensures model efficiency. Cross-database evaluation demonstrates that the proposed method achieves blood pressure (BP) estimation performance falling within the numerical thresholds specified by IEEE, BHS, and AAMI guidelines. Under a lightweight strategy, the LSM2oE exhibits significant clinical application potential, with mean absolute errors for systolic BP, mean arterial pressure, diastolic BP, and heart rate being 4.02 mmHg, 2.99 mmHg, 3.00 mmHg, and 2.40 bpm, respectively. The parameter counts and FLOPs are 1.26 M and 0.15 Gmac, respectively, surpassing existing baseline models with only 4.0% of the parameter volume of the teacher model. Additionally, leveraging a cloud-edge collaboration framework, we achieved hemodynamic assessment across multiple Internet of Medical Things (IoMT) devices via a local area network and the RV1126 platform. The system demonstrates cross-scale analysis capability and real-time parameter estimation performance in IoMT environments, showcasing extensive application potential.
- 13 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (17) , 35875-35889
A Dual-Focus Cloud–Edge Collaborative Framework in Multitask Hemodynamic Parameter Cross-Scale Analysis: The Equilibrium of Clinical Performance and Efficiency
The precise monitoring of hemodynamic parameters is crucial for cardiovascular health assessment and disease prevention. However, current noninvasive hemodynamic monitoring technologies fail to balance performance and efficiency. To overcome these challenges, this study introduces a dual-focus multitask fusion framework built on a sparse multigate mixture-of-experts network (SM2oE) and multiview photoplethysmography (PPG) for the accurate estimation of noninvasive hemodynamic parameters. This framework integrates a multiscale fusion architecture with a hybrid attention mechanism and incorporates an uncertainty regression loss function (UR-Loss) to enhance intertask information fusion and overall model performance. Through structured pruning and bidirectional knowledge distillation, the framework effectively reduces computational costs and ensures model efficiency. Cross-database evaluation demonstrates that the proposed method achieves blood pressure (BP) estimation performance falling within the numerical thresholds specified by IEEE, BHS, and AAMI guidelines. Under a lightweight strategy, the LSM2oE exhibits significant clinical application potential, with mean absolute errors for systolic BP, mean arterial pressure, diastolic BP, and heart rate being 4.02 mmHg, 2.99 mmHg, 3.00 mmHg, and 2.40 bpm, respectively. The parameter counts and FLOPs are 1.26 M and 0.15 Gmac, respectively, surpassing existing baseline models with only 4.0% of the parameter volume of the teacher model. Additionally, leveraging a cloud-edge collaboration framework, we achieved hemodynamic assessment across multiple Internet of Medical Things (IoMT) devices via a local area network and the RV1126 platform. The system demonstrates cross-scale analysis capability and real-time parameter estimation performance in IoMT environments, showcasing extensive application potential.
- 14 May 2025
- Published by Elsevier in Information Fusion
- Vol. 123
XSleepFusion: A dual-stage information bottleneck fusion framework for interpretable multimodal sleep analysis
- 14 May 2025
- Published by Elsevier in Information Fusion
- Vol. 123
XSleepFusion: A dual-stage information bottleneck fusion framework for interpretable multimodal sleep analysis
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (2) , 1078-1088
A Lightweight Hybrid Model Using Multiscale Markov Transition Field for Real-Time Quality Assessment of Photoplethysmography Signals
Objective: The proliferation of wearable devices has escalated the standards for photoplethysmography (PPG) signal quality. This study introduces a lightweight model to address the imperative need for precise, real-time evaluation of PPG signal quality, followed by its deployment and validation utilizing our integrated upper computer and hardware system. Methods: Multiscale Markov Transition Fields (MMTF) are employed to enrich the morphological information of the signals, serving as the input for our proposed hybrid model (HM). HM undergoes initial pre-training utilizing the MIMIC-III and UCI databases, followed by fine-tuning the Queensland dataset. Knowledge distillation (KD) then transfers the large-parameter model's knowledge to the lightweight hybrid model (LHM). LHM is subsequently deployed on the upper computer for real-time signal quality assessment. Results: HM achieves impressive accuracies of 99.1% and 96.0% for binary and ternary classification, surpassing current state-of-the-art methods. LHM, with only 0.2 M parameters (0.44% of HM), maintains high accuracy despite a 2.6% drop. It achieves an inference speed of 0.023 s per image, meeting real-time display requirements. Furthermore, LHM attains a 97.7% accuracy on a self-created database. HM outperforms current methods in PPG signal quality accuracy, demonstrating the effectiveness of our approach. Additionally, LHM substantially reduces parameter count while maintaining high accuracy, enhancing efficiency and practicality for real-time applications. Conclusion: The proposed methodology demonstrates the capability to achieve high-precision and real-time assessment of PPG signal quality, and its practical validation has been successfully conducted during deployment. Significance: This study contributes a convenient and accurate solution for the real-time evaluation of PPG signals, offering extensive application potential.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 28 (2) , 1078-1088
A Lightweight Hybrid Model Using Multiscale Markov Transition Field for Real-Time Quality Assessment of Photoplethysmography Signals
Objective: The proliferation of wearable devices has escalated the standards for photoplethysmography (PPG) signal quality. This study introduces a lightweight model to address the imperative need for precise, real-time evaluation of PPG signal quality, followed by its deployment and validation utilizing our integrated upper computer and hardware system. Methods: Multiscale Markov Transition Fields (MMTF) are employed to enrich the morphological information of the signals, serving as the input for our proposed hybrid model (HM). HM undergoes initial pre-training utilizing the MIMIC-III and UCI databases, followed by fine-tuning the Queensland dataset. Knowledge distillation (KD) then transfers the large-parameter model's knowledge to the lightweight hybrid model (LHM). LHM is subsequently deployed on the upper computer for real-time signal quality assessment. Results: HM achieves impressive accuracies of 99.1% and 96.0% for binary and ternary classification, surpassing current state-of-the-art methods. LHM, with only 0.2 M parameters (0.44% of HM), maintains high accuracy despite a 2.6% drop. It achieves an inference speed of 0.023 s per image, meeting real-time display requirements. Furthermore, LHM attains a 97.7% accuracy on a self-created database. HM outperforms current methods in PPG signal quality accuracy, demonstrating the effectiveness of our approach. Additionally, LHM substantially reduces parameter count while maintaining high accuracy, enhancing efficiency and practicality for real-time applications. Conclusion: The proposed methodology demonstrates the capability to achieve high-precision and real-time assessment of PPG signal quality, and its practical validation has been successfully conducted during deployment. Significance: This study contributes a convenient and accurate solution for the real-time evaluation of PPG signals, offering extensive application potential.
- Open Access
- 27 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 349-354
CardiacSegFormer: Transformer for Semantic Segmentation of Cardiac Images
- 27 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 349-354
Open AccessCardiacSegFormer: Transformer for Semantic Segmentation of Cardiac Images
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-15
Personalized Transfer Learning for Single-Lead ECG-Based Sleep Apnea Detection: Exploring the Label Mapping Length and Transfer Strategy Using Hybrid Transformer Model
Objective: The automatic sleep apnea (SA) detection based on deep learning (DL) and single-lead electrocardiogram (ECG) has been extensively studied. We aim to explore the impact of different DL model structures and label mapping length (LML) on personalized transfer learning (TL), providing personalized TL applicability conditions based on proposed hybrid Transformer model. Methods: Two DL models, a pure convolutional neural network (CNN)-based model (PCM) and proposed hybrid Transformer-based model (HTM), are included in the study. Eight different LMLs are considered. Furthermore, various personalized TL strategies are introduced to thoroughly explore the impact. Finally, two-sided t-tests are utilized to evaluate the significance. Results: In the same database, the average accuracy and AUC for the personalized PCM are 0.8412 and 0.9002 respectively with p<0.001, while the hybrid Transformer-based personalized model achieves an average accuracy of 0.8537 and an average AUC of 0.9147 with p<0.001. Across databases, the accuracy and AUC of personalized HTM reach 0.8271 and 0.8724 respectively, and p<0.001. Conclusion: The increase of LML has a beneficial impact in general model (GM) and personalized model for different model structures. The HTM exhibits better performance in both GM and personalized TL compared to the PCM. Additionally, personalized TL achieves significant improvement when utilizing only positive samples within the same database. However, it is more advantageous to utilize only negative samples when performing cross-database personalized TL. Significance: This paper provides guidance for personalized TL in SA detection and provide a HTM-based personalized TL method.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-15
Personalized Transfer Learning for Single-Lead ECG-Based Sleep Apnea Detection: Exploring the Label Mapping Length and Transfer Strategy Using Hybrid Transformer Model
Objective: The automatic sleep apnea (SA) detection based on deep learning (DL) and single-lead electrocardiogram (ECG) has been extensively studied. We aim to explore the impact of different DL model structures and label mapping length (LML) on personalized transfer learning (TL), providing personalized TL applicability conditions based on proposed hybrid Transformer model. Methods: Two DL models, a pure convolutional neural network (CNN)-based model (PCM) and proposed hybrid Transformer-based model (HTM), are included in the study. Eight different LMLs are considered. Furthermore, various personalized TL strategies are introduced to thoroughly explore the impact. Finally, two-sided t-tests are utilized to evaluate the significance. Results: In the same database, the average accuracy and AUC for the personalized PCM are 0.8412 and 0.9002 respectively with p<0.001, while the hybrid Transformer-based personalized model achieves an average accuracy of 0.8537 and an average AUC of 0.9147 with p<0.001. Across databases, the accuracy and AUC of personalized HTM reach 0.8271 and 0.8724 respectively, and p<0.001. Conclusion: The increase of LML has a beneficial impact in general model (GM) and personalized model for different model structures. The HTM exhibits better performance in both GM and personalized TL compared to the PCM. Additionally, personalized TL achieves significant improvement when utilizing only positive samples within the same database. However, it is more advantageous to utilize only negative samples when performing cross-database personalized TL. Significance: This paper provides guidance for personalized TL in SA detection and provide a HTM-based personalized TL method.