SMStephen Morgan

Stephen Morgan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stephen Morgan has a total of 3 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Lower tidal volume ventilation post‐bilateral lung transplantation is associated with ventilator‐free days

    by Stephen Morgan, Anders Aneman, Nick Olsen, Priya Nair

    Background: There is limited evidence regarding the effect of invasive mechanical ventilation practice post‐bilateral lung transplantation. Invasive mechanical ventilation practice may be associated with prolonged ventilation, particularly when referenced to donor anthropometrics.Methods: This was a single‐centre retrospective cohort study that included consecutive adult bilateral lung transplant recipients between 2015 and 2021 who were ventilated for a minimum of 24 h post‐surgery. Lower and higher tidal volume sub‐groups were defined for mean and maximum values indexed to both donor and recipient predicted body weight over the first 72 h. The primary outcome was ventilator‐free days in the first 28 days, and this was analysed using the Wilcoxon rank sum test and a competing risks regression. We used a Cox proportional hazards model to examine the relationship of ventilator‐free days and tidal volume and 90‐day survival.Results: The cohort included 111 recipients, and the median ventilator‐free days for the entire cohort was 25 (21–26). Lower tidal volume indexed to donor predicted body weight after 48 and 72 h was associated with more ventilator‐free days (25 (23–26) vs. 24 (17–26), p = .04 and 24 (21–25) vs. 20 (14–24), p = .02) and increased cumulative incidence of successful extubation (sub‐distribution hazard ratio 1.54 (1.07–2.20), p = .02 and SHR 1.87 (1.07–3.27), p = .03). Ventilator‐free days and lower tidal volume were associated with increased 90‐day survival.Conclusions: Lower tidal volume ventilation indexed to donor predicted body weight is associated with more ventilator‐free days post‐bilateral lung transplantation.Editorial Comment: Postoperative ventilation with lower tidal volume indexed to the donor's predicted body weight was associated with more ventilator‐free days in patients undergoing bilateral lung transplantation. No difference was found between lower versus higher tidal volume ventilation for other patient‐important outcomes. The results highlight the need for larger prospective clinical trials.


  • Open Access

    Mechanical ventilation post‐bilateral lung transplantation: A scoping review

    by Stephen Morgan, Anders Aneman, Priya Nair

    Background: Evidence from lung protective ventilation (LPV) in the acute respiratory distress syndrome has commonly been applied to guide periprocedural ventilation in lung transplantation. However, this approach may not adequately consider the distinctive features of respiratory failure and allograft physiology in the lung transplant recipient.This scoping review was conducted to systematically map the research describing ventilation and relevant physiological parameters post‐bilateral lung transplantation with the aim to identify any associations with patient outcomes and gaps in the current knowledge base.Methods: To identify relevant publications, comprehensive literature searches of electronic bibliographic databases were conducted with the guidance of an experienced librarian in MEDLINE, EMBASE, SCOPUS and the Cochrane Library. The search strategies were peer‐reviewed using the PRESS (Peer Review of Electronic Search Strategies) checklist. The reference lists of all relevant review articles were surveyed.Publications were included in the review if they described relevant ventilation parameters in the immediate post‐operative period, published between 2000 and 2022 and involved human subjects undergoing bilateral lung transplantation. Publications were excluded if they included animal models, only single‐lung transplant recipients or only patients managed with extracorporeal membrane oxygenation.Results: A total of 1212 articles were screened, 27 were subject to full‐text review and 11 were included in the analysis. The quality of the included studies was assessed to be poor with no prospective multi‐centre randomised controlled trials. The frequency of reported retrospective LPV parameters was as follows: tidal volume (82%), tidal volume indexed to both donor and recipient body weight (27%) and plateau pressure (18%). Data suggest that undersized grafts are at risk of unrecognised higher tidal volume ventilation indexed to donor body weight. The most reported patient‐centred outcome was graft dysfunction severity in the first 72 h.Conclusion: This review has identified a significant knowledge gap that indicates uncertainty regarding the safest ventilation practice in lung transplant recipients. The risk may be greatest in patients with established high‐grade primary graft dysfunction and undersized allografts, and these factors may define a sub‐group that warrants further investigation.