Diego A. Caban-Rivera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Diego A. Caban-Rivera has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Curtis L. Johnson
Department of Biomedical Engineering, University of Delaware
3 shared publications - Anna Y. Klintsova
Department of Psychological & Brain Sciences, University of Delaware, Newark, DE 19716, USA
1 shared publication - Carson Ingo
Department of Physical Therapy and Human Movement Sciences, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
1 shared publication Cassandra P. Bodner
Department of Psychological & Brain Sciences, University of Delaware, Newark, DE 19716, USA
1 shared publication- Dhrubo Jyoti
LCD Nanotech, Hanover, NH 03755, USA
1 shared publication Elijah E.W. Van Houten
Departement de Genie Mécanique, Universite de Sherbrooke, QC J1K 2R1, Canada
1 shared publication
Latest Publications
- 31 March 2026
- Published by Elsevier in Brain Research
- Vol. 1883, 150300
Mechanical properties of the developing brain in a model of fetal alcohol spectrum disorders and relationships to perineuronal net integrity
- 31 March 2026
- Published by Elsevier in Brain Research
- Vol. 1883, 150300
Mechanical properties of the developing brain in a model of fetal alcohol spectrum disorders and relationships to perineuronal net integrity
- Open Access
Multi-echo BOLD fMRI improves cerebrovascular reactivity estimates in stroke
Cerebrovascular reactivity (CVR), the ability of cerebral blood vessels to dilate or constrict in response to a vasoactive stimulus, is a clinically meaningful measure of cerebrovascular health. Head motion and other noise sources substantially impact CVR quality, particularly in clinical populations. In this study, we evaluated multi-echo fMRI techniques, including optimal combination of echoes (ME-OC) and multi-echo independent component analysis (ME-ICA), for improving CVR quality relative to single-echo fMRI in participants with stroke. In a breath-hold fMRI dataset, ME-OC significantly improved CVR quality metrics and reduced the percentage of negative CVR values in normal-appearing gray and white matter ( p p <0.05). These findings demonstrate that multi-echo fMRI can improve CVR estimation in clinical populations, particularly in low signal-to-noise datasets, enhancing the feasibility of CVR analyses in stroke studies and allowing for better visualization of stroke-related CVR deficits.
Open AccessMulti-echo BOLD fMRI improves cerebrovascular reactivity estimates in stroke
Cerebrovascular reactivity (CVR), the ability of cerebral blood vessels to dilate or constrict in response to a vasoactive stimulus, is a clinically meaningful measure of cerebrovascular health. Head motion and other noise sources substantially impact CVR quality, particularly in clinical populations. In this study, we evaluated multi-echo fMRI techniques, including optimal combination of echoes (ME-OC) and multi-echo independent component analysis (ME-ICA), for improving CVR quality relative to single-echo fMRI in participants with stroke. In a breath-hold fMRI dataset, ME-OC significantly improved CVR quality metrics and reduced the percentage of negative CVR values in normal-appearing gray and white matter ( p p <0.05). These findings demonstrate that multi-echo fMRI can improve CVR estimation in clinical populations, particularly in low signal-to-noise datasets, enhancing the feasibility of CVR analyses in stroke studies and allowing for better visualization of stroke-related CVR deficits.
- 1 March 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 141, 105744
Transversely-isotropic brain in vivo MR elastography with anisotropic damping
- 1 March 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 141, 105744
Transversely-isotropic brain in vivo MR elastography with anisotropic damping
- Open Access
- 27 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (5) , 055015
Reverberant magnetic resonance elastographic imaging using a single mechanical driver
Reverberant elastography provides fast and robust estimates of shear modulus; however, its reliance on multiple mechanical drivers hampers clinical utility. In this work, we hypothesize that for constrained organs such as the brain, reverberant elastography can produce accurate magnetic resonance elastograms with a single mechanical driver. To corroborate this hypothesis, we performed studies on healthy volunteers ( n = 3); and a constrained calibrated brain phantom containing spherical inclusions with diameters ranging from 4–18 mm. In both studies (i.e. phantom and clinical), imaging was performed at frequencies of 50 and 70 Hz. We used the accuracy and contrast-to-noise ratio performance metrics to evaluate reverberant elastograms relative to those computed using the established subzone inversion method. Errors incurred in reverberant elastograms varied from 1.3% to 16.6% when imaging at 50 Hz and 3.1% and 16.8% when imaging at 70 Hz. In contrast, errors incurred in subzone elastograms ranged from 1.9% to 13% at 50 Hz and 3.6% to 14.9% at 70 Hz. The contrast-to-noise ratio of reverberant elastograms ranged from 63.1 to 73 dB compared to 65 to 66.2 dB for subzone elastograms. The average global brain shear modulus estimated from reverberant and subzone elastograms was 2.36 ± 0.07 kPa and 2.38 ± 0.11 kPa, respectively, when imaging at 50 Hz and 2.70 ± 0.20 kPa and 2.89 ± 0.60 kPa respectively, when imaging at 70 Hz. The results of this investigation demonstrate that reverberant elastography can produce accurate, high-quality elastograms of the brain with a single mechanical driver.
- 27 February 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (5) , 055015
Open AccessReverberant magnetic resonance elastographic imaging using a single mechanical driver
Reverberant elastography provides fast and robust estimates of shear modulus; however, its reliance on multiple mechanical drivers hampers clinical utility. In this work, we hypothesize that for constrained organs such as the brain, reverberant elastography can produce accurate magnetic resonance elastograms with a single mechanical driver. To corroborate this hypothesis, we performed studies on healthy volunteers ( n = 3); and a constrained calibrated brain phantom containing spherical inclusions with diameters ranging from 4–18 mm. In both studies (i.e. phantom and clinical), imaging was performed at frequencies of 50 and 70 Hz. We used the accuracy and contrast-to-noise ratio performance metrics to evaluate reverberant elastograms relative to those computed using the established subzone inversion method. Errors incurred in reverberant elastograms varied from 1.3% to 16.6% when imaging at 50 Hz and 3.1% and 16.8% when imaging at 70 Hz. In contrast, errors incurred in subzone elastograms ranged from 1.9% to 13% at 50 Hz and 3.6% to 14.9% at 70 Hz. The contrast-to-noise ratio of reverberant elastograms ranged from 63.1 to 73 dB compared to 65 to 66.2 dB for subzone elastograms. The average global brain shear modulus estimated from reverberant and subzone elastograms was 2.36 ± 0.07 kPa and 2.38 ± 0.11 kPa, respectively, when imaging at 50 Hz and 2.70 ± 0.20 kPa and 2.89 ± 0.60 kPa respectively, when imaging at 70 Hz. The results of this investigation demonstrate that reverberant elastography can produce accurate, high-quality elastograms of the brain with a single mechanical driver.